Series TE Duct and Immersion Building Automation Temperature Sensor

Duct and Immersion Building Automation Temperature Sensor
Available up to 18" Probe Length, Thermistor or RTD Outputs

$0.00

Available up to 18" Probe Length, Thermistor or RTD Outputs

The SERIES TE Duct and Immersion Temperature Sensor can be used to monitor air or water temperature throughout a building management system or an air handler unit. Flanged duct sensors monitor the supply or return air and provide a thermistor or RTD output to the digital controller. Immersion sensors which are supplied with compression fittings are typically used to monitor the hot or chilled water lines throughout a building. Thermowells are recommended, but not required on the immersion sensors.

For variable air volume applications, the Series TE can be configured to have 8' plenum rated cable with flying leads. Standard units come with 4" leads with an integral terminal block to eliminate carrying extra wire nuts. For housing models, multiple knockouts provide easy conduit access to any side of the housing. The 1/4 turn lid comes with a chain to prevent it from being lost during installation.

For models with resistive thermistors or RTD outputs, please click here for temperature to resistance lookup tables.

Product Applications

  • Building automation
  • VAV temperature sensing
  • Chiller or boiler loops
  • AHU monitoring
More Information
Model Chart
EXAMPLE TE IBN A 04 4 4 12 Series TE-IBN-A0444-12 Immersion Probe, 10K type 3 thermistor, 4" probe length, 1/4" probe diameter, 4" flying leads, with 1/2" NPT connection.
SERIES TE             Duct and Immersion Building Automation Temperature Sensor
MOUNTING CONFIGURATION   DFN
DFG
DFW
IBN
IBG
IBW
          Duct Flange Probe Only   (not w/ Connection 12,14)
Duct Flange In Housing    (not w/ Connection 12,14)
Duct Flange NEMA 4X Housing (not w/ Connection 12,14) 
Immersion Probe Only
Immersion in Housing             (not w/ Connection 00)
Immersion NEMA 4X Housing  (not w/ Connection 00)
SENSOR TYPE     A
B
C
D
E
F
G
H
I
J
K
L
M
P
        10K Type III Thermistor
10K Type II Thermistor
3K Ohm Thermistor
PT100 Ohm RTD
PT1000 Ohm RTD
20K Thermistor
1.8K Thermistor
5K Thermistor
100K Thermistor
2.252 Thermistor
NI 1000 Ohm RTD
Balco NI 1000 Ohm RTD
PT100 Ohm RTD 1/10 DIN (3-wire)
PT1000 Ohm RTD 1/10 DIN (3-wire)
PROBE LENGTH       25
04
06
08
12
18
      2.5"
4"
6"
8"
12"
18"
PROBE DIAMETER         4     1/4"
TERMINATION           1
2
3
4
5
6
7
8
  4" Flying leads w/female connector Molex recept 
4" Flying leads w/male connector Mate-N-Loc plug
4" Flying leads spade terminals
4" Flying leads terminal block 
8' Plenum cable w/female connector Molex recept
8' Plenum cable w/male connector Mate-N-Loc plug
8' Plenum cable spade terminals
8' Plenum cable
FITTINGS             00
12
14
None (Integral)
1/2" NPT Compression Fitting
1/4" NPT Compression Fitting
Accuracy: Thermistor temperature sensor: ±0.22°C @ 25°C (±0.4°F @ 77°F); RTD temperature sensor DIN Class A: ±0.15°C @ 0°C (±0.28°F @ 32°F).
Temperature Limits: Operating: -40 to 302°F (-40 to 150°C).
Sensor Curves: See Resistance vs. Temperature Table.
Cable Rating: Plenum option includes UL listed plenum cable.
Housing Material: Meets UL, 94 V-O polycarbonate plastic.
Thermowell Material: TE-I: 304 SS.
Housing Rating: NEMA 4X (IP66) (DFW, IBW only).
Weight: 5.3 oz (150.3 g).
  • Easy to mount external tab housing and flange options for duct applications
  • 1/4 turn housing cover with chain to prevent dropping
  • Multiple conduit knockouts for easy installation positioning
  • 8´ plenum rated cable option
  • Terminal connector eliminates need for wire nuts