Data Sheet (PDF)
Specifications INPUT SIGNALS Thermocouple: J, K, T, E, R, S, B, C, N RTD: 10 ½ Cu, 100 ½ Pt 385, 100 ½ Pt 392, 200 ½ Pt 385, 200 ½ Pt 392, 120 ½ Ni 385 DC Voltage: Linear, square root, logarithmic DC Current: 0/4 to 20 mA, 10 to 50 mA Dry Contact INPUT ACCURACY Thermocouple: ±1.5°C for J, K, T, E, N (Nicrosil-Nisil); ±3°C for R, S and C; ±4°C for B RTD: ±0.5°C or 0.2% DC Voltage: ±0.06% for ±150 mV, ±1.25 V, ±2.5 V; ±0.1% for ±12.5 V, ±25 V Current: ±0.15% with external 50½ 0.1% shunt Input Resolution: 0.0015% of full scale, 16 bit Input Impedance: >10 megaohms on 150 mV,1.25 V, 2.5 V, >100 K on 5, 12.5, 25 Volt ranges Max. Input: 50 Vdc Scan Rate: All points measured every 125 ms Isolation: 300 Vdc or peak Vac between channels Common Mode Noise Rejection: >100 dB, 50/60 Hz Normal Mode Noise Rejection: >50 dB, 50/60 Hz EMC Compliance: Meets or exceeds the requirements of EMC 89/336/EEC RECORDING Recording Rates: User programmable from 8 samples per second to 1 sample every 10 minutes Format: Windows compatible file system. Proprietary file structure Storage Capacity: 256 MB samples on 128 MB flash card Internal Memory: 1 MB RAM (non-volatile) DISPLAY Display Type Color: CCFL backlit Active Matrix TFT Liquid Crystal Display 142 mm (5.6') Resolution Color: 320 H x 234 V pixels Display Modes: Graphics (trending, vertical or horizontal), bar graphs (vertical or horizontal), digital meter, alphanumeric alarm and event data or combinations on a split screen. Review trend data. Search by time, date or signal value Display Update Rate: 1 second. Data update rate programmable from 1 to 60 seconds Virtual Chart Speed: Programmable: 10 mm/hr to 15,000 mm/hr (0.5 in/hr to 600 in/hr). Chart speed is independent of storage rate Virtual Chart Scales: 2 sets of 8 scales Display Windows: Time/date, graphics (bars, large digital, trends), disk status, system status, menu button bar, unit identification, alarms/events Buffer: Internal buffer enables real time browsing of historic chart data independent of recorded data. Configuration: Touchscreen control menu with button bar or simple programming on IBM compatible PC with optional software Software: Spreadsheet export utility software included. Graphical software optional. Windows XP/Vista/7/8/10. On CD. OPTIONS Alarm Contacts: 3 or 6 isolated Form C, 3 amp @ 250 Vac or 26 Vdc Remote Inputs: 3 isolated inputs user selectable as dry contact or 5 to 12 Vdc activated. Inputs share a common. Configurable for chart control, alarm, acknowledge/reset, event markers, totalizer reset or logic input Communications: ESD protected RS-232 with full hand shaking. Supports modem or isolated RS-485 network port. Serial Protocol - MODBUS RTU or MODBUS ASCII. Ethernet: 10BaseT POWER Power Requirements: 100 to 240 Vac, 50/60 Hz, or 125 to 300 Vdc, 35 VA max. Power Fail Protection: Programmed parameters stored in non-volatile memory. Clock battery backed. Retention time without power >12 months. ENVIRONMENTAL Operating Temperature: -10 to 50°C (14 to 122°F) Operating Humidity: 10% to 80% RH non-condensing Wash Down: IP65 front panel only Safety: Meets UL-311-1 and EN61010-1 Dimensions: 144 x 144 x 236 mm (5.669 x 5.669 x 9'); panel cutout: 138 x 138 mm (5.43 x 5.43') Weight: Approx. 3.2 kg (7 lb)