The OM-CP-RHTEMP1000IS-A2 is an Intrinsically Safe humidity and temperature data logger. It carries hazardous location, intrinsically safe certification in accordance with the latest issue of FM3600, FM3610. This certification makes the device ideal for EtO Sterilization, environmental studies, and numerous other hostile environment applications.
The device can be started and stopped directly from your computer and its small, sleek size allows it to fit almost anywhere. The OM-CP-RHTEMP1000IS-A2 makes data retrieval quick and easy. Simply insert the device into the OM-CP-IFC400 or the OM-CP-IFC406 USB docking station (sold separately) and our user-friendly software does the rest The small size of the OM-CP-RHTEMP1000IS-A2, allows it to be placed in remote or hard to reach locations. The device now features a battery life indicator allowing users to easily identify low voltage and change batteries when required. This feature maximizes the use of your battery life and is a cost saving efficiency.
The OM-CP Data Logger Software is a powerful, analytic tool. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis.
TEMPERATURE
Temperature Sensor
Resistance Temperature Detector (RTD)
Temperature Range
-40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution
0.01 °C (0.018 °F)
Calibrated Accuracy
±0.5 °C (0 °C to ±50 °C) ±0.9 °F (32 °F to 122 °F)
HUMIDITY
Humidity Sensor
Capacitive Polymer
Humidity Range
0 %RH to 100 %RH (non-condensing)
Humidity Resolution
0.1 %RH
±3.0 %RH maximum
Specified Accuracy Range
25 %RH to 75 %RH +20 °C to +40 °C (68 °F to 104 °F) Hysteresis Error 1 % typical, 3 % Maximum
GENERAL
Memory
32,768 Readings
Start Modes
Software programmable immediate startor delay start, up to 24 months in advance
Real Time Recording
May be used with PC to monitor andrecord data in real time
Reading Rate
1 reading every second up to 1 reading every 24 hours
Calibration
Digital calibration through software
Calibration Date
Automatically recorded within device
Battery Type
Tadiran TL-2150 3.6V lithium battery included, user replaceable in a non-hazardous location
Battery Life
2 years typical at 15 minute reading rate
Data Format
Date and time stamped °C, °F, K, °R %RH, mg/mL, Dew Point
Time Accuracy
16 seconds / month -40 °C to 80 °C
ComputerInterface
OM-CP-IFC400 or OM-CP-IFC406
OperatingSystemCompatibility
Windows XP SP3/7/8/10
Software Compatibility
Standard Software version 4.2.19.1 or later Secure Software version 4.2.18.0 or later
Operating Environment
-40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 100 %RH (case properly sealed)
Dimensions
1.67 in x 0.97 in dia. (42.3 mm x 24.6 mm dia.)
Weight
2.4 oz (68 g)
Enclosure
316 Stainless Steel/Radel
Approvals
CEFM Class 3600, Rev. Jan 2018 FM Class 3610, Rev. Jan 2018 CAN/CSA-C22.2 No. 60079-0:15 CAN/CSA-C22.2 No. 60079-11:14