Inline Temperature Transmitter for PT100 RTDs

Water resistant with M12 connections for the sensor and signal, this transmitter includes a user programmable 4-20 milliamp output.
$148.67

Description

The M12TX temperature transmitter for pt100 RTD is easily ranged and programmable by a computer.The configuration kit required forprogramming is M12TX-CONFIG.This unique transmitter is idealfor areas with space limitationswhere traditional headconnections are too large to fit.The M12 thread design offers asecure industrial connection. Theintegrated connection allows thetransmitter to be mounted directlyon to the sensor.

Specifications
Body: Thermoplastic material
Connection:
    M12x1 Male: In accordance to VDE0627 (output connection)
    M12x1 Female: In accordance to VDE0627 (input connection Pt100)
Sensor: RTD Pt100 (alpha symbol 0.00385) 3-wire connection
Range: -50 to 500°C (-58 to 932°F)
Sensor Break Monitoring:
    Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action
    Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
OutputSignal: 4 to 20 mA
Factory Scaling: 4 to 20 mA Output = 0 to 150°C Default Setting
Permissible Load: 700 @ 24Vdc [RLo= (Vsupply-8,5)/0,020]
Response Time (90%): <50 ms
Isolation In-Out: Non-isolated
Power Supply: 8.5 to 32 Vdc (polarity protected)
Environment Conditions
Temperature: -40 to 80°C (-40 to 176°F) (for plastic body)
Relative Humidity: 0 to 100%
EMC: In accordance to EN 61326
Degree of Protection: IP65 and IP67 in accordance to IEC60529
Accuracy
Transmitter: Maximum of ±0,2°C or ±0.2% of span
Sensor: Class A in accordance to IEC751
Temperature Influence [Deviation from 20°C (68°F)]: Maximum of ±0.3°C/25°C (77°F) or ±0.3% of span/25°C (77°F)
Supply Voltage Influence: Negligible
Range Configurations: It is possible set the input temperature range (span) by the M12TX-CONFIG configuration kit (PC with OS Windows® required)
Zero Adjustments: Any value between -50 to 50°C (-58 to 122°F)
Minimum Span: 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
Sensor Error Compensation: Over 2 points (maximum 1% of span)
Factory Setting: 0 to 150°C (32 to 302°F)/sensor break >21 mA (upscale)


*The M12TX-PT100 is compatible with all sensors with a "-2" European wiring option.
For example: PR-26A-3-100-A-1/4-1200-M12-2, the -2 at the end of the part number specifies the wiring.
The PR-22 probes have standard european wiring.