Differential Pressure (Price & availability on application)

SKU: press-product30
Design Two independent measuring systems, vee entry 60° Nominal size in mm 100, 160 Accuracy class 1.6 Scale ranges 0 ... 0.6 to 0 ... 60 bar Scale range must be selected in relation to the highest total pressure applied! In heating plants with circulating pumps, the overall pressure is usually defined as equal to the hydrostatic pressure plus the pump pressure. In order to ensure a good readability, the pressure differential to be indicated should be no less than 1/6 of the full scale range. When ordering please state both pressures: a) maximum pressure applied, b) differential pressure Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 33 per EN 60 529 / lEC 529
Design Two independent measuring systems, vee entry 60° Nominal size in mm 100, 160 Accuracy class 1.6 Scale ranges 0 ... 0.6 to 0 ... 60 bar Scale range must be selected in relation to the highest total pressure applied! In heating plants with circulating pumps, the overall pressure is usually defined as equal to the hydrostatic pressure plus the pump pressure. In order to ensure a good readability, the pressure differential to be indicated should be no less than 1/6 of the full scale range. When ordering please state both pressures: a) maximum pressure applied, b) differential pressure Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 33 per EN 60 529 / lEC 529
More Information
Applications Measurement of differential pressures or of two different pressures applied | For gaseous and liquid media that are not highly viscous or crystallising and will not attack copper alloy parts | Heating, ventilation and air conditioning
Description Design Two independent measuring systems, vee entry 60° Nominal size in mm 100, 160 Accuracy class 1.6 Scale ranges 0 ... 0.6 to 0 ... 60 bar Scale range must be selected in relation to the highest total pressure applied! In heating plants with circulating pumps, the overall pressure is usually defined as equal to the hydrostatic pressure plus the pump pressure. In order to ensure a good readability, the pressure differential to be indicated should be no less than 1/6 of the full scale range. When ordering please state both pressures: a) maximum pressure applied, b) differential pressure Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -20 ... +60 °C Medium: +60 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value Ingress protection IP 33 per EN 60 529 / lEC 529
Model No 711.11, with Bourdon Tube Element, Vee Entry
Special Features Differential pressure with moving dial | Cost-effective and reliable | Scale ranges from 0 ... 0.6 bar