Combination Style Industrial pH Electrodes

The PHE-7151 combination electrodes are ruggedly constructed
$227.78
Insertion/Submersion Combination Electrodes
The PHE-7151 series combination electrodes are ruggedly constructed; the outer body is ABS with 3/4" MNPT threads at both ends. The maximum insertion length is 31.75 mm/1.25". Electrodes are annular PTFE liquid junction refillable and include 15 ft of cable with a BNC connector. For applications with temperatures up to 120°C (248°F), units are available in polyphenylene sulfide (PPS).***

These electrodes have a special plunger design allowing them to be mounted at any angle.

Part No. Length
mm/in
Dia.
mm/in
pH
Range
Temp.
°C
Refill
or Gel
R (megohms)
at 25°C/77°F
Description
PHE-7151-15 140/5.5 30/1.2 0 to 12 0 to 80 Refill 400 Refillable general purpose**
PHE-7351-15 140/5.5 30/1.2 0 to 12 0 to 80 Gel 400 Sealed general purpose
PHE-7152-15 140/5.5 30/1.2 0 to 14 0 to 80 Refill 1000 Refillable high pH applications**
ORE-7151-15 140/5.5 30/1.2 0 to 80 Refill General purpose refillable ORP**
** Refill Solution: PHFS-7151-4, 4 oz bottle; PHFS-7151-16, 16 oz bottle
***For polyphenylene sulfide body, add suffix “-PPS” to part number and $50 to price


In-Line Disposable Electrodes
OMEGA™ in-line combination electrodes mount on standard pipe tees for continuous pH or ORP monitoring. The electrode is constructed in a PVDF housing with 1/2" MNPT threading. Probe insertion length is 25 mm (1") and is able to withstand pressure up to 150 psi. Three-meter (10-ft.) cable length and BNC connector are standard. Dimensions: 127 x 25 mm (5 x 10")

A

CPVC In-Line Disposable pH Electrodes
Also available, the CPVC In-Line Disposable Electrode is ruggedly constructed to withstand up to 100 psi. Probe insertion length is 51 mm (2") with 3/4" diameter. A 3/4" MNPT fitting is standard and is supplied with 3 m (10 ft.) of cable and a BNC connector. Dimensions: 168 x 25 mm (6.6 x 10")

B

Part No. ph Range Temperature
Range °C/°F
Notes R Megohms
at 25°C/77°F
A PHE-5311-10 0 to 13 5 to 100/23 to 212 General purpose 50
A PHE-5312-10 0 to 14 0 to 100/32 to 212 High pH 200
A PHE-5411-10 0 to 13 5 to 100/23 to 212 Double junction 50
A PHE-5412-10 0 to 14 0 to 100/32 to 212 Double junction high pH 200
A ORE-5311-10 ORP 5 to 100/23 to 212 Platinum band
A ORE-5411-10 ORP 5 to 100/23 to 212 Platinum band double junction
A ORE-5419-10 ORP 5 to 100/23 to 212 Gold disc double junction
for cyanide applications
B PHE-5316-10 0 to 13 -5 to 80/23 to 176 Sealed Ag/AgCl 50
Automatic Temperature Compensation is not required with ORP (Redox) electrodes.