Capsule pressure gauge,test gauge series, class 0.1 and (Price & availability on application)

SKU: press-product29
Design Following EN 837-3, with measuring cell underneath the case, class 0.1 instruments with transport case and acceptance test certificate (individual listing of the calibration points) Nominal size in mm 250 Accuracy class 0.1 and 0.25 Scale ranges Class 0.1: 0 ... 25 to 0 ... 400 mbar Class 0.25: 0 ... 6 to 0 ... 400 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium Gas Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum Temperature effect The indicated class accuracy applies to a room temperature of +20 °C. Temperature-related zero offsets can be corrected by means of the zero adjustment. Ingress protection IP 54 per EN 60529 / lEC 529
Design Following EN 837-3, with measuring cell underneath the case, class 0.1 instruments with transport case and acceptance test certificate (individual listing of the calibration points) Nominal size in mm 250 Accuracy class 0.1 and 0.25 Scale ranges Class 0.1: 0 ... 25 to 0 ... 400 mbar Class 0.25: 0 ... 6 to 0 ... 400 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium Gas Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum Temperature effect The indicated class accuracy applies to a room temperature of +20 °C. Temperature-related zero offsets can be corrected by means of the zero adjustment. Ingress protection IP 54 per EN 60529 / lEC 529
More Information
Applications For gaseous, dry, clean and non-aggressive media | Precision measurement in laboratories | Highest-accuracy pressure measurement | Testing and calibration of industrial type pressure gauges
Description Design Following EN 837-3, with measuring cell underneath the case, class 0.1 instruments with transport case and acceptance test certificate (individual listing of the calibration points) Nominal size in mm 250 Accuracy class 0.1 and 0.25 Scale ranges Class 0.1: 0 ... 25 to 0 ... 400 mbar Class 0.25: 0 ... 6 to 0 ... 400 mbar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium Gas Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum Temperature effect The indicated class accuracy applies to a room temperature of +20 °C. Temperature-related zero offsets can be corrected by means of the zero adjustment. Ingress protection IP 54 per EN 60529 / lEC 529
Model No 612.11
Special Features Knife edge pointer and dial with mirror band scale for optimal accuracy of reading | Precise movement with wear parts of argentan | Particularly easy-to-read scale due to nominal size 250 | Front access to the zero adjustment | Scale ranges from 0 … 6 mbar