Bourdon tube pressure (Price & availability on application)
SKU:
press-product12
Design
EN 837-1
Nominal size in mm
50, 63, 100
Accuracy class
NS 50, 63: 1.6
NS 100: 1.0
Scale ranges
NS 50: 0 ... 1 to 0 ... 400 bar
NS 63, 100: 0 ... 0.6 to 0 ... 1000 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
NS 50, 63:
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: Full scale value
NS 100:
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Permissible temperature
Ambient: -20 ... +60 °C
Medium: +60 °C maximum
Temperature effect
When the temperature of the measuring system deviates
from the reference temperature (+20 °C):
Max. ±0.4 %/10 K of the span
Ingress protection
IP 65 per EN 60529 / lEC 529
Design
EN 837-1
Nominal size in mm
50, 63, 100
Accuracy class
NS 50, 63: 1.6
NS 100: 1.0
Scale ranges
NS 50: 0 ... 1 to 0 ... 400 bar
NS 63, 100: 0 ... 0.6 to 0 ... 1000 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
NS 50, 63:
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: Full scale value
NS 100:
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Permissible temperature
Ambient: -20 ... +60 °C
Medium: +60 °C maximum
Temperature effect
When the temperature of the measuring system deviates
from the reference temperature (+20 °C):
Max. ±0.4 %/10 K of the span
Ingress protection
IP 65 per EN 60529 / lEC 529
Intended for adverse service conditions where pulsating or vibration exists |
Suitable for all gaseous and liquid media that will not obstruct the pressure system or attack copper alloy parts |
Hydraulics |
Compressors, shipbuilding
Description
Design
EN 837-1
Nominal size in mm
50, 63, 100
Accuracy class
NS 50, 63: 1.6
NS 100: 1.0
Scale ranges
NS 50: 0 ... 1 to 0 ... 400 bar
NS 63, 100: 0 ... 0.6 to 0 ... 1000 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
NS 50, 63:
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: Full scale value
NS 100:
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Permissible temperature
Ambient: -20 ... +60 °C
Medium: +60 °C maximum
Temperature effect
When the temperature of the measuring system deviates
from the reference temperature (+20 °C):
Max. ±0.4 %/10 K of the span
Ingress protection
IP 65 per EN 60529 / lEC 529
Model No
213.53, liquid filling, stainless steel case
Special Features
Vibration and shock resistant |
Especially sturdy design |
NS 63, 100 approved by German Lloyd and Gosstandart approval |
Scale ranges up to 0 ... 1,000 bar