Bourdon tube pressure (Price & availability on application)

Nominal size in mm 63 and 80 Accuracy class pm ≤ 4 bar: ± 0.08 bar 4 bar < pm ≤ 10 bar: ± 0.16 bar pm > 10 bar: ± 0.25 bar (pm ... measured pressure) Error limits are met within a temperature range between 15 °C and 25 °C Scale ranges 0 ... 4 bar 0 ... 10 bar 0 ... 12 bar (only NS 80) Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -20 … +60 °C Medium: +40 °C maximum Storage: -40 … +70 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature range (-10 ... +40 °C): pm ≤ 4 bar: 0.1 % of 4 bar 4 bar < pm ≤ 10 bar: 0.05 % of 10 bar pm > 10 bar: 0.05 % of the full scale value (pm ... measured pressure) Ingress protection IP 44 per EN 60529 / lEC 529
Nominal size in mm 63 and 80 Accuracy class pm ≤ 4 bar: ± 0.08 bar 4 bar < pm ≤ 10 bar: ± 0.16 bar pm > 10 bar: ± 0.25 bar (pm ... measured pressure) Error limits are met within a temperature range between 15 °C and 25 °C Scale ranges 0 ... 4 bar 0 ... 10 bar 0 ... 12 bar (only NS 80) Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -20 … +60 °C Medium: +40 °C maximum Storage: -40 … +70 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature range (-10 ... +40 °C): pm ≤ 4 bar: 0.1 % of 4 bar 4 bar < pm ≤ 10 bar: 0.05 % of 10 bar pm > 10 bar: 0.05 % of the full scale value (pm ... measured pressure) Ingress protection IP 44 per EN 60529 / lEC 529
More Information
Applications For use in tyre inflation systems for monitoring the tyre pressure when inflating the tyres of motor vehicles | Filling stations, garages, service stations
Description Nominal size in mm 63 and 80 Accuracy class pm ≤ 4 bar: ± 0.08 bar 4 bar < pm ≤ 10 bar: ± 0.16 bar pm > 10 bar: ± 0.25 bar (pm ... measured pressure) Error limits are met within a temperature range between 15 °C and 25 °C Scale ranges 0 ... 4 bar 0 ... 10 bar 0 ... 12 bar (only NS 80) Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: full scale value Operating temperature Ambient: -20 … +60 °C Medium: +40 °C maximum Storage: -40 … +70 °C Temperature effect When the temperature of the measuring system deviates from the reference temperature range (-10 ... +40 °C): pm ≤ 4 bar: 0.1 % of 4 bar 4 bar < pm ≤ 10 bar: 0.05 % of 10 bar pm > 10 bar: 0.05 % of the full scale value (pm ... measured pressure) Ingress protection IP 44 per EN 60529 / lEC 529
Model No 111.14, for tyre pressure apparatus
Special Features Designs per EN 12645 | EEC type-approval certificate | Scale ranges 0 ... 4 bar, 0 ... 10 bar, 0 ... 12 bar