Bourdon tube pressure gaugeTest gauge series, class (Price & availability on application)

Design per EN 837-1, including transport case and acceptance test certificate (individual listing of the calibration points) Nominal size in mm 250 Accuracy class 0.1 Scale ranges 0 ... 1.0 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: Gas > 25 bar: Oil Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.1 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
Design per EN 837-1, including transport case and acceptance test certificate (individual listing of the calibration points) Nominal size in mm 250 Accuracy class 0.1 Scale ranges 0 ... 1.0 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: Gas > 25 bar: Oil Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.1 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
More Information
Applications For gaseous and liquid media that are not highly viscous or crystallising | Precision measurement in laboratories | Highest-accuracy pressure measurement | Testing and calibration of industrial type pressure gauges
Description Design per EN 837-1, including transport case and acceptance test certificate (individual listing of the calibration points) Nominal size in mm 250 Accuracy class 0.1 Scale ranges 0 ... 1.0 to 0 ... 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges Adjustment medium ≤ 25 bar: Gas > 25 bar: Oil Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Permissible temperature Ambient: -20 … +60 °C Medium: +100 °C maximum Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.1 %/10 K of full scale value Ingress protection IP 54 per EN 60529 / lEC 529
Model No 342.11
Special Features Knife edge pointer and dial with mirror band scale for optimal accuracy of reading | Precise movement with wear parts of argentan | Particularly easy-to-read scale due to nominal size 250 | Scale ranges up to 0 … 1,600 bar