Bourdon tube pressure gaugeStainless steel, safety version, high overpressure (Price & availability on application)

SKU: press-product39
Design Safety pattern (Solidfront) referring to EN 837-1 Nominal size 100 and 160 mm Measuring ranges and overpressure ranges Measuring range in bar Overpressure range up to ... bar -1 ... 0 3 0 ... 0.6 2.5 0 ... 1 4 0 ... 1.6 6 0 ... 2.5 10 0 ... 4 16 0 ... 6 25 0 ... 10 40 0 ... 16 60 0 ... 25 80 0 ... 40 100 Accuracy class Measuring range: 1.0 The measuring range end is marked by a triangle Pressure limitation Steady: end value of measuring range Fluctuating: 0.9 x end value of measuring range Short time: Overpressure range Permissible temperature Ambient: -40 ... +60°C without liquid filling -20 ... +60 °C gauges with glycerine filling (Model 233.36 ) Medium: +200 °C maximum without liquid filling +100 °C maximum with liquid filling (Model 233.36 ) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 % / 10 K of full scale value Ingress protection IP 65 per EN 60529/IEC 529
Design Safety pattern (Solidfront) referring to EN 837-1 Nominal size 100 and 160 mm Measuring ranges and overpressure ranges Measuring range in bar Overpressure range up to ... bar -1 ... 0 3 0 ... 0.6 2.5 0 ... 1 4 0 ... 1.6 6 0 ... 2.5 10 0 ... 4 16 0 ... 6 25 0 ... 10 40 0 ... 16 60 0 ... 25 80 0 ... 40 100 Accuracy class Measuring range: 1.0 The measuring range end is marked by a triangle Pressure limitation Steady: end value of measuring range Fluctuating: 0.9 x end value of measuring range Short time: Overpressure range Permissible temperature Ambient: -40 ... +60°C without liquid filling -20 ... +60 °C gauges with glycerine filling (Model 233.36 ) Medium: +200 °C maximum without liquid filling +100 °C maximum with liquid filling (Model 233.36 ) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 % / 10 K of full scale value Ingress protection IP 65 per EN 60529/IEC 529
More Information
Applications Especially suited for occasional short-duration overpressures of up to 4 times scale range | Increased safety requirements | With liquid filled case for applications with high dynamic pressure pulsations or vibrations (Model 233.36) | For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive ambience | Process industries: chemical/petro-chemical, power stations, mining, on- and offshore, environmental technology, mechanical engineering and plant construction
Description Design Safety pattern (Solidfront) referring to EN 837-1 Nominal size 100 and 160 mm Measuring ranges and overpressure ranges Measuring range in bar Overpressure range up to ... bar -1 ... 0 3 0 ... 0.6 2.5 0 ... 1 4 0 ... 1.6 6 0 ... 2.5 10 0 ... 4 16 0 ... 6 25 0 ... 10 40 0 ... 16 60 0 ... 25 80 0 ... 40 100 Accuracy class Measuring range: 1.0 The measuring range end is marked by a triangle Pressure limitation Steady: end value of measuring range Fluctuating: 0.9 x end value of measuring range Short time: Overpressure range Permissible temperature Ambient: -40 ... +60°C without liquid filling -20 ... +60 °C gauges with glycerine filling (Model 233.36 ) Medium: +200 °C maximum without liquid filling +100 °C maximum with liquid filling (Model 233.36 ) Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 % / 10 K of full scale value Ingress protection IP 65 per EN 60529/IEC 529
Model No 232.36, 233.36
Special Features High overpressure safety, overpressure range is indicated completely on scale | Safety pressure gauge with solid baffle wall designed in compliance with operational safety requirements of EN 837-1 | All stainless steel construction