Series MPC Pump Controller

Series MPC Pump Controller

Taxes included. Shipping calculated at checkout.

SKU :

SKU:SeriesMPC

Calibration needed?

Pump Controller One or Two Pump Control with Built-In Alternation, Over Temperature Protection and Seal Failure Monitoring

View full details

One or Two Pump Control with Built-In Alternation, Over Temperature Protection and Seal Failure Monitoring

The Mercoid® MPC Pump Controller provides versatile level control in a standard 1/4 DIN package. Designed for use with almost any style level transmitter the unit displays the present level and main set point value. Incorporated in the MPC is programmable level differential for on/off control of one or two pumps, valves, or other devices through two SPDT relays. Also featured are two additional programmable alarm contacts with front alarm light indication.

The MPC is flexible and incorporates a user-friendly programming menu. The front face meets NEMA 4X for outdoor panel mounting. So many features are combined into the MPC that it eliminates many components in a pump control system.

Product Applications

  • Water and wastewater
  • Sump and sludge pits, clarifiers, digesters
  • Chemical storage tanks
  • Oil tanks
  • Reservoirs
  • Selectable pump alternation when used with two pumps to minimize pump wear. With alternation “on” a seal failure or over temperature condition will force the non-failed pump to lead status and stop alternation.
  • When used with a submersible pump including a moisture sensor the MPC has alarm light indication of seal failure.
  • When used with a pump including a thermostat the MPC has alarm light indication of pump over temperature and removes the pump from service. The Pump can be brought back into service automatically or by manual reset when the pump has cooled down.
  • Alarms can be programmed for output indication of pump seal failure or over temperature.
  • Selectable time delay, for pump two, on power up to prevent both pumps from starting at the same time. If power is lost, upon regaining power a time delay of up to 60 seconds can be selected to prevent too large of a current draw.
  • Integral 24 VDC power supply for level transmitter.
  • Displays pump run time from a front panel button.
  • Test System function that simulates the process input to ensure the pumps are operating or to test programming.
  • User selectable security lock-out of programming and/or set points.
  • Process input retransmission as a current (4 to 20 mA) or voltage (2 to 10 VDC) analog signal (standard model MPC is set for current retransmission. For voltage retransmission add suffix “-RV”.
  • In the event of power loss, upon regaining power a time delay of up to 60 seconds can be selected to prevent excessively large current draw
  • Two additional programmable alarm contacts with front alarm light indication
  • Front panel face meets NEMA 4X for outdoor panel mounting
  • User-friendly programming menu