- Description
Features
- Ideal for Precision Batching applications.
- Closing the lid resets the display total.
- Measures liquids to Specific Gravity 1.4
- Nutating disc P.D. measuring chamber.
- Small Impurities can pass through measuring chamber without jamming.
- Low hydraulic thrust minimises wear.
- Internal Lithium battery (10+ year battery life)
- Accuracy: ± 1.5% full scale flowrange
- Repeatability: ± 0.2%
- Maximum working pressure: 1160 kPa
- Maximum liquid temperature: 50 °C
- Connection: 20, 25 & 32 mm : threaded BSP(m) 40 mm : flanged BSP(f)
New Features
- Shows 6 digits total in Litres (L) or KiloLitres (KL) up to 3 decimal place and rate in Litres per minute (L/M) or Litres per second (L/S) with 1 decimal place. (specify which at time of ordering)
- User friendly 1 point re-calibration function –self calculation for a new k-factor.
- External re-calibrate via PC with RFID and EWM calibration software –No need to access buttons
- External Reset input for PLC/mechanical switch.
- Wake-Reset function –turns on the display before resetting the total.
- Default Display is LPM and total LITRES