- Description
Design
Small, compact version
WIKA trade pattern DT-GM 87 10 226
Nominal size in mm
80
Accuracy class
4.0: scale ranges 0 ... 16 mbar and 0 ... 25 mbar
2.5: scale ranges 0 ... 40 mbar to 0 ... 600 mbar
Scale ranges
0 ... 16 mbar to 0 ... 600 mbar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
Steady: full scale value
Fluctuating: full scale value
Overpressure safety
Either side max. 16 bar
Max. working pressure (static pressure)
16 bar
Operating temperature
Ambient: -15 ... +60 °C
Medium: +70 °C maximum
Temperature effect
When temperature of the measuring system deviates from reference temperature (+20 °C):
max. ±0.5 %/10 K of true scale value
Ingress protection
lP 66 per EN 60 529 / lEC 529