- Description
- Download Brochures
Design
per EN 837-1, including transport case and acceptance test certificate (individual listing of the calibration points)
Nominal size in mm
250
Accuracy class
0.1
Scale ranges
0 ... 1.0 to 0 ... 1,600 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Adjustment medium
≤ 25 bar: Gas
> 25 bar: Oil
Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Permissible temperature
Ambient: -20 … +60 °C
Medium: +100 °C maximum
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
Max. ±0.1 %/10 K of full scale value
Ingress protection
IP 54 per EN 60529 / lEC 529
- Choosing a selection results in a full page refresh.
- Opens in a new window.