{"title":"Temperature Sensing Elements","description":"\u003cdiv class=\"service-sec pb-5\"\u003e\n\u003cp\u003e\nUse these temperature sensing elements to make your own temperature sensor assemblies. Choose from thermocouple, thin-film or wire-wound RTD, thermistor, or solid state sensor elements.\n\u003c\/p\u003e\n\u003c\/div\u003e","products":[{"product_id":"surface-mount-rtd-with-brass-housing","title":"Surface Mount RTD with Brass Housing","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   This flat platinum resistance detector represents the latest development by OMEGA in miniaturization of temperature sensing devices. It combines the precision temperature measuring capability of the platinum resistance detector with the small temperature sensing tip and rapid response time of the thermocouple. An immediate field of application for the TFD is in the area of surface temperature measurement.. Rapid response times are achieved with the TFD because it possesses a large surface-area to- volume ratio and the temperature-sensitive platinum layer is separated from the medium to be measured by a thin ceramic substrate of high thermal conductivity. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eNote on Assembling Omega \"TFD\" Series RTD Elements to Extension Wires:\u003c\/b\u003e These RTD elements are made with platinum coated nickel lead wires. Since platinum does not easily wet with most soft solders, we advise that they be spot welded or silver soldered to extension wires when required. \u003cbr\u003e\u003cbr\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817458114855,"sku":"TFD-RTD","price":89.8,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817458147623,"sku":"TFD-RTD","price":89.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tfd_rtd_l_pmzoiggr6vappe2l.jpg?v=1741318614"},{"product_id":"individually-available-thin-film-platinum-rtd-elements","title":"Individually Available Thin Film Platinum RTD Elements","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e OMEGA introduces the OMEGAFILM™ platinum RTD element—an element achieved by employing construction techniques similar to those used to manufacture miniature electronic integrated circuits. The result: a precision element available in sizes considerably smaller than the head of a match. All this in a rugged, accurate, ceramic encased package! Best of all, OMEGAFILM™ elements are calibrated to the worldwide accepted DIN 43760 curve (alpha=0.00385), allowing use with standard off-the-shelf instrumentation available from OMEGA and others, both in the United States and abroad.\u003cbr\u003e \u003cbr\u003e\u003cb\u003eAccuracy and Specifications\u003c\/b\u003e:\u003cbr\u003eOMEGAFILM™ platinum RTD’s are calibrated to the internationally accepted DIN 43760 curve (alpha=0.00385) and meet 0.1% DIN standard tolerance. When you use these tables, please note that the specific operating ranges for elements vary and are listed on their specifications pages.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplications\u003c\/b\u003e: Because of their small size and thin, flat packaging, OMEGAFILM™ sensors greatly extend the field of RTD applications. Series W RTD elements are thin film encased in a cylindrical ceramic package. Series W single cylindrical RTD elements (such as the W2103) lend themselves to encapsulation in short ⅛' O.D. protection tubes or shallow holes bored in a metal casing . Series W dual RTD elements ( such as the W2202) consist of 2 separate 2 wire thin film RTD elements in a cylindrical ceramic 4 wire package. Series F (such as F3101) are thin film 2 wire RTD elements on a flat ceramic base. These may be taped, cemented or embedded. To obtain accurate representative measurements, good thermal contact between the surface and the element is important. For temporary installations, a compatible temperature-rated heat- conductive compound, such as a heat sink grease can be used.\u003cbr\u003e\u003cbr\u003e \u003cdiv class=\"tableWrapPP\"\u003e\u003ctable border=\"1\" cellpadding=\"2\" cellspacing=\"0\" width=\"660\" bordercolor=\"black\"\u003e \u003ctbody\u003e\n\u003ctr align=\"center\" bgcolor=\"#FFBEA6\"\u003e \u003ctd\u003e\n\u003cb\u003eSeries\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e\n\u003cb\u003e15 mm Lead Length Dimensions in Millimeters\u003cbr\u003e(1 mm = 0.03937')\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e\n\u003cb\u003eModel No.\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e                   \u003cb\u003eNominal\u003cbr\u003eSingle or \u003c\/b\u003e     \u003cb\u003eResistance\u003cbr\u003eDual\u003c\/b\u003e            \u003cb\u003e(ohms)\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e\n\u003cb\u003eTemperature\u003cbr\u003eRange\u003c\/b\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd bgcolor=\"#FFBEA6\"\u003e\n\u003cb\u003eW\u003c\/b\u003e \u003c\/td\u003e \u003ctd align=\"center\" valign=\"middle\"\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eW2102\u003cbr\u003eW2112\u003cbr\u003eW2122\u003cbr\u003eW2132\u003cbr\u003eW2142\u003cbr\u003eW2152 \u003c\/td\u003e \u003ctd\u003e1    x    100 \u003cbr\u003e1    x    200 \u003cbr\u003e1    x    400 \u003cbr\u003e1    x    500 \u003cbr\u003e1    x    1000\u003cbr\u003e1    x    2000 \u003c\/td\u003e \u003ctd rowspan=\"4\"\u003e-50 to 600°C\u003cbr\u003e(-58 to 1112°F) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd bgcolor=\"#FFBEA6\"\u003e\n\u003cb\u003eW\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e \u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eW2202 \u003cbr\u003eW2212\u003cbr\u003eW2222\u003cbr\u003eW2232\u003cbr\u003eW2242 \u003c\/td\u003e \u003ctd\u003e2    x     100 \u003cbr\u003e2    x    200 \u003cbr\u003e2    x     400 \u003cbr\u003e2    x    500 \u003cbr\u003e2    x     1000 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd rowspan=\"2\" bgcolor=\"#FFBEA6\"\u003e\n\u003cb\u003eW\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eW2103 \u003c\/td\u003e \u003ctd\u003e1    x    100 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eW2204 \u003c\/td\u003e \u003ctd\u003e2    x    100 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd bgcolor=\"#FFBEA6\"\u003e\n\u003cb\u003eWS\u003c\/b\u003e \u003c\/td\u003e \u003ctd align=\"center\" valign=\"middle\"\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eWS81 \u003c\/td\u003e \u003ctd\u003e1    x    100 \u003c\/td\u003e \u003ctd\u003e-50 to 600°C\u003cbr\u003e(58 to 1112°F) \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e \u003cdiv class=\"tableWrapPP\"\u003e\u003ctable border=\"1\" cellpadding=\"2\" cellspacing=\"0\" width=\"660\" bordercolor=\"black\"\u003e \u003ctbody\u003e\n\u003ctr align=\"center\" bgcolor=\"#FFBEA6\"\u003e \u003ctd\u003e\n\u003cb\u003eSeries\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e\n\u003cb\u003e10 mm Lead Length Dimensions in Millimeters\u003cbr\u003e(1 mm = 0.03937')\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e\n\u003cb\u003eModel No.\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e                    \u003cb\u003eNominal\u003cbr\u003eSingle or\u003c\/b\u003e     \u003cb\u003eResistance\u003cbr\u003eDual\u003c\/b\u003e            \u003cb\u003e(ohms)\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e\n\u003cb\u003eTemperature\u003cbr\u003eRange\u003c\/b\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd bgcolor=\"#FFBEA6\"\u003e\n\u003cb\u003eF\u003c\/b\u003e \u003c\/td\u003e \u003ctd align=\"center\" valign=\"middle\"\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eF3101\u003cbr\u003e\u003cbr\u003eF3131\u003cbr\u003e\u003cbr\u003eF3141 \u003c\/td\u003e \u003ctd\u003e1      x     100 \u003cbr\u003e\u003cbr\u003e1     x      500 \u003cbr\u003e\u003cbr\u003e1     x     1000 \u003c\/td\u003e \u003ctd rowspan=\"5\"\u003eMax range:\u003cbr\u003e -50 to 500°C\u003cbr\u003e (-58 to 932°F)\u003cbr\u003e however,\u003cbr\u003e Class A\u003cbr\u003e tolerance\u003cbr\u003e applies to\u003cbr\u003e -30 to 300°C\u003cbr\u003e (-22 to 572°F) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd bgcolor=\"#FFBEA6\"\u003e \u003cb\u003eF\u003c\/b\u003e \u003c\/td\u003e \u003ctd align=\"center\" valign=\"middle\"\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eF3102\u003cbr\u003e\u003cbr\u003eF3132\u003c\/td\u003e \u003ctd\u003e1     x     100 \u003cbr\u003e\u003cbr\u003e1     x      500 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd bgcolor=\"#FFBEA6\"\u003e \u003cb\u003eF\u003c\/b\u003e \u003c\/td\u003e \u003ctd align=\"center\" valign=\"middle\"\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eF3142 (Class B only) \u003c\/td\u003e \u003ctd\u003e1     x     1000 \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd bgcolor=\"#FFBEA6\"\u003e\n\u003cb\u003eF\u003c\/b\u003e \u003c\/td\u003e \u003ctd align=\"center\" valign=\"middle\"\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eF3105 \u003cbr\u003e\u003cbr\u003eF3145 \u003c\/td\u003e \u003ctd\u003e1     x     100 \u003cbr\u003e\u003cbr\u003e1     x      1000  \u003c\/td\u003e \u003c\/tr\u003e \u003ctr align=\"center\"\u003e \u003ctd bgcolor=\"#FFBEA6\"\u003e\n\u003cb\u003eF\u003c\/b\u003e \u003c\/td\u003e \u003ctd align=\"center\" valign=\"middle\"\u003e\n\u003cimg border=\"0\"\u003e \u003c\/td\u003e \u003ctd\u003eF3107 \u003c\/td\u003e \u003ctd\u003e1     x     100 \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cb\u003eNote on Assembling Omega 'F' Series RTD Elements to Extension Wires:\u003c\/b\u003e These RTD elements are made with platinum coated nickel lead wires. Since platinum does not easily wet with most soft solders, we advise that they be spot welded or silver soldered to extension wires when required. \u003cbr\u003e \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817458442535,"sku":"F3105-3100-W2100-2200","price":64.97,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817458475303,"sku":"F3105-3100-W2100-2200","price":64.97,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/f3105_3100_w2100_2200_l_xvi8bqlditayxvct.jpg?v=1741318637"},{"product_id":"standard-accuracy-ceramic-wire-wound-platinum-rtd-elements","title":"Standard Accuracy Ceramic Wire Wound Platinum RTD Elements","description":"\u003cp\u003eThese Standard Accuracy Ceramic Wire-Wound Platinum RTD Elements provide dependable temperature sensing for industrial, research, or OEM applications. With a stable platinum element wound onto a ceramic core, they deliver consistent performance over a wide range of temperatures. Each element is built for longevity and accuracy, ensuring traceable measurements when calibrated. Local support and calibration services are available for your quality assurance needs.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003ePlatinum RTD with ceramic wire-wound construction\u003c\/p\u003e\n\n\u003cp\u003eExcellent long-term stability and repeatability\u003c\/p\u003e\n\n\u003cp\u003eWide temperature operating range\u003c\/p\u003e\n\n\u003cp\u003eStandard accuracy suitable for industrial and laboratory use\u003c\/p\u003e\n\n\u003cp\u003eCalibration-ready for traceable results\u003c\/p\u003e\n\n\u003cp\u003eLocal support for documentation and testing\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817458704679,"sku":"1PT100K-RTD-ELEMENTS","price":68.69,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817458737447,"sku":"1PT100K-RTD-ELEMENTS","price":68.69,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/1pt100k_rtd_elements_ks0gpy0uldoqebxc.jpg?v=1741318657"},{"product_id":"capsule-platinum-rtd-sensor","title":"Capsule Platinum RTD Sensor","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cp\u003eReady to use New platinum RTD capsules have insulated lead wires welded and anchored internally. No splicing to fragile elements is required. This construction assures reliable, rugged embedment, insertion, or probe assembly. Tip diameters from 0.086 to 0.125\"\". Standard sensors and encapsulation materials rated up to 540°C (1000°F). Choose the moisture resistant version for condensing conditions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStandard Lead Length\u003c\/strong\u003e: 1 m (40\")\u003cbr\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: TFE Leads: -200 to 260°C (-320 to 500°F)\u003cbr\u003e\u003cstrong\u003ePolyimide Leads\u003c\/strong\u003e: -200 to 350°C (-320 to 660°F) \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFiberglass Leads\u003c\/strong\u003e: -75 to 510°C (-100 to 950°F)\u003cbr\u003e\u003cstrong\u003eMoisture Resistant\u003c\/strong\u003e: -50 to 200°C (-60 to 390°F)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSensing Element\u003c\/strong\u003e: International grade thin film platinum, a = 0.00385 \u0026amp;Omega\/\u0026amp;Omega\/°C per IEC 60751\u003cbr\u003eIce Point Resistance: 100.00±0.06\u0026amp;Omega or 1000.0±0.6\u0026amp;Omega at 0°C\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eTime Constant (Water at 3'\/Second)\u003c\/strong\u003e:\u003cbr\u003e0.086 Diameter = 0.5 seconds\u003cbr\u003e0.098 Diameter = 0.6 seconds\u003cbr\u003e0.125 Diameter = 0.8 seconds\u003cbr\u003e0.187 Diameter = 1.5 seconds\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSelf-Heating: Greater than 15 mW\/°C\u003c\/strong\u003e \u003cbr\u003e\u003cstrong\u003eInterchangeability\/Accuracy\u003c\/strong\u003e: Class A (±0.15+.002*|t|°C [where|t|= absolute value of temperature in\u003cbr\u003e°C]) between -50 and 300°C, Class B above and below these temperatures Long Term Stability: Better than 0.05°C (0.02% of resistance) per 5 years, -50 to 300°C (-58 to 572°F), 0.25°C per year to 540°C (1004°F)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e: Greater than 50 Megohms at 50 Vdc at 25°C (77°F) Maximum Current: 100 \u0026amp;Omega = 5 mA, 1000 \u0026amp;Omega = 2 mA for limited self-heating also suitable as self-heated sensors, Recommended Current: 1 mA, maximum for temperature sensing,Case Materials: Alumina on 0.125 and 0.086 diameter, Polyimide [350°C(662°F)] on 0.098 diameter\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eLead Materials, Nickel-Coated Copper-Insulated\u003c\/strong\u003e: \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e28 AWG Fiberglass\u003c\/strong\u003e: Rated to 510°C (950°F)\u003cbr\u003e\u003cstrong\u003e28 AWG TFE\u003c\/strong\u003e: Rated to 260°C (500°F)\u003cbr\u003e\u003cstrong\u003e28 AWG Polyimide\u003c\/strong\u003e: Rated to 350°C (660°F)\u003c\/p\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817458901287,"sku":"PRTDCAP","price":509.09,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817458934055,"sku":"PRTDCAP","price":509.09,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/prtdcap_l_bb22u12rysg3q2bl.jpg?v=1741318676"},{"product_id":"glass-wire-wound-platinum-rtd-elements","title":"Glass Wire Wound Platinum RTD Elements","description":"\u003cp\u003eThe Glass Wire-Wound Platinum RTD Elements deliver lab-grade temperature precision with rugged durability. Each element is crafted with platinum wire wound onto a strong core, then encased in glass to protect from contaminants and reduce drift. This construction ensures excellent accuracy, repeatability, and thermal stability—making them ideal for lab instruments, reference standards, or critical industrial control systems. With lead-wire options and various resistance ratings available, these RTD elements easily integrate into high-precision instrumentation. Designers and technicians seeking dependable foundational sensors with long-term accuracy trust these elements to deliver premium performance.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003ePlatinum wire wound sensor for superior precision\u003c\/p\u003e\n\n\u003cp\u003eGlass encapsulation for stability and protection\u003c\/p\u003e\n\n\u003cp\u003eExcellent accuracy and repeatability\u003c\/p\u003e\n\n\u003cp\u003eIdeal for lab-grade instrumentation and reference use\u003c\/p\u003e\n\n\u003cp\u003eMultiple resistance and wiring configurations available\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817459196199,"sku":"1PT100G-RTD-ELEMENTS","price":161.03,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817459228967,"sku":"1PT100G-RTD-ELEMENTS","price":161.03,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/1pt100g_rtd_elements_jggiiastk0lqset3.jpg?v=1741318697"},{"product_id":"epoxy-coated-thermistor-elements","title":"Epoxy Coated Thermistor Elements","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003ch4\u003eConstruction\u003c\/h4\u003e\n\u003cp\u003eThermistors are manufactured from oxides of nickel, manganese, iron, cobalt, magnesium, titanium and other metals. All are available epoxy encapsulated and color coded, with two 3\" leads.Thermistors with 0.2°C interchangeability also are available encased in a 2\" long waterproof PFA tube; order by adding 100 to the part number. For example: 44005 is a standard 3000 ohm thermistor; 44105 is a PFA-encased thermistor with the same temperature\/resistance values. Stiff wire is placed in the tube so that, with slight finger pressure, it can be bent to any configuration. For PFA-encased thermistors, consult the factory.\u003c\/p\u003e\n\u003ch4\u003eStability\u003c\/h4\u003e\n\u003cp\u003eFinished thermistors are chemically stable and not significantly affected by aging or exposure to strong fields of hard nuclear radiation. Time Constant -The time required for a thermistor to indicate 63% of a newly impressed temperature is called the time constant. For a thermistor suspended by its leads in a “well stirred” oil bath, it is 1 sec. max., or 2.5 sec. max. for PFA-encased thermistors, and in still air it is 10 sec. max., or 25 sec. max. for PFA units.\u003c\/p\u003e\n\u003ch4\u003eDissipation Constant\u003c\/h4\u003e\n\u003cp\u003eThe power in milliwatts required to raise a thermistor 1°C above the surrounding temperature is the dissipation constant. For all thermistors suspended by their leads in a “well stirred” oil bath, it is 8 mw\/ °C min., or 1 mw\/°C min. in still air. Operating Temperature -Maximum operating temperature is 150°C. Long-term stability studies show that extended operation or continued cycling above 90°C will cause thermistors with values less than 2252 ohms at 25°C to exceed tolerances eventually. Thermistors 44030, 44031, 44032 and 44033 are designed for operation below 75°C. They will operate safely up to 100°C, but extended use above 75°C may cause a change in resistance. Storage temperature for thermistors is from -80 to 120°C.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817459458343,"sku":"44000-THERMIS-ELEMENTS","price":78.47,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817459491111,"sku":"44000-THERMIS-ELEMENTS","price":78.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/44000_thermis_elements_1tqeey414o0lv8uk.jpg?v=1741318718"},{"product_id":"high-accuracy-ceramic-wire-wound-platinum-rtd-elements","title":"High Accuracy Ceramic Wire Wound Platinum RTD Elements","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\n\u003cp class=\"contentTitle\"\u003eThese \"KN\" Series wire wound platinum sensing elements are available in three tolerance classes:\u003c\/p\u003e\n\u003cspan class=\"descCopyPP\"\u003e \u003cb\u003e\u003cbr\u003e Class A, Temperature Range    -100 to 450°C,   Tolerance = ± 0.15+(.002 * t) °C\u003cbr\u003e Class 1\/3B, Temperature Range    -100 to 350°C,  Tolerance = ± 0.10+(.0017 * t) °C\u003cbr\u003e Class 1\/10B, Temperature Range    0 to 100°C,  Tolerance = ± 1\/10*( 0.30+(.005 * t)) °C\u003cbr\u003e with t = temperature in °C regardless of sign.\u003cbr\u003e \u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNote: These elements are capable of being exposed to temperatures between -196 and 600°C, however the  tolerances apply only within the temperature ranges shown for each class.\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e These elements are made with wire wound platinum coils, ceramic housings and palladium-gold alloy lead wires.   The small size of the sensor body allows for easy installation in protective tubes or custom housings.  Applications  include a variety of processes and equipment. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817459654951,"sku":"1PT100KN-2PT100KN","price":107.28,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817459687719,"sku":"1PT100KN-2PT100KN","price":107.28,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/1pt100kn_2pt100kn_jvdexxjt3cjdw5m0.jpg?v=1741318738"},{"product_id":"ruggedized-thin-film-rtd-elements","title":"Ruggedized Thin Film RTD elements","description":"\u003cp\u003eThe Ruggedized Thin Film RTD Elements are designed for accurate temperature measurement in harsh industrial environments. These elements feature a robust construction that resists mechanical stress, vibration, and thermal cycling. They offer precise and stable readings over a wide temperature range, making them suitable for applications in manufacturing, HVAC systems, and process control. Their compact size allows for integration into tight spaces without compromising performance.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eRugged design withstands mechanical stress and vibration\u003c\/p\u003e\n\n\u003cp\u003eAccurate and stable temperature measurements over a wide range\u003c\/p\u003e\n\n\u003cp\u003eSuitable for harsh industrial and process control environments\u003c\/p\u003e\n\n\u003cp\u003eCompact size for easy integration into tight spaces\u003c\/p\u003e\n\n\u003cp\u003eLong-term reliability with minimal drift\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817459786023,"sku":"1PT100FR-RTD-ELEMENTS","price":55.28,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817459818791,"sku":"1PT100FR-RTD-ELEMENTS","price":55.28,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/1pt100fr_rtd_elements_bzr8obu2qeiswt2q.jpg?v=1741318757"},{"product_id":"solid-state-temperature-sensor-with-a-linear-current-output","title":"Solid State Temperature Sensor with a Linear Current Output","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The AD590 is a small IC temperature sensor that converts a temperature input into a proportional current output. \u003cbr\u003e\u003cbr\u003eThe advanced technology in the AD590 is especially suited for special temperature measurement and control applications between –55 and 150°C when solid state reliability, linearity and accuracy are required. The AD590 temperature sensor can be used to determine minimum, average, and differential temperatures, in addition to being used for thermocouple cold junction compensation and temperature control applications. The size and responsiveness of the AD590 IC Sensor makes it perfect for uses where size is a consideration, such as on PC boards or heat sinks. \u003cbr\u003e\u003cbr\u003eJust power up and measure absolute temperature (Kelvin). No linearization, amplification or cold junction compensation is required.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003cbr\u003e Absolute Maximum Ratings Forward Voltage (E+ to E–):\u003c\/b\u003e +44 V\u003cbr\u003e \u003cb\u003eReverse Voltage (E+ to E–):\u003c\/b\u003e –20 V Breakdown Voltage\u003cbr\u003e \u003cb\u003e(case to E+ or E–):\u003c\/b\u003e ±200 V\u003cbr\u003e \u003cb\u003eLead Temperature:\u003c\/b\u003e 300°C\u003cbr\u003e \u003cb\u003eVoltage Range:\u003c\/b\u003e +4 to +30 Vdc Nominal Current Output at 25°C\u003cbr\u003e \u003cb\u003e(298.2 K):\u003c\/b\u003e 298.2 µA Nominal Temperature Coefficient: 1 µA\/K\u003cbr\u003e \u003cb\u003e\u003cb\u003eCalibration Error:\u003c\/b\u003e J:\u003c\/b\u003e ±5.0°C\u003cbr\u003e \u003cb\u003emaximum (K:\u003c\/b\u003e ±2.5°C)\u003cbr\u003e \u003cb\u003eAbsolute Error:\u003c\/b\u003e w\/o external\u003cbr\u003e \u003cb\u003eCalibration Adjustment:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003e\u003cb\u003eJ:\u003c\/b\u003e ±10.0°C maximum (K:\u003c\/b\u003e ±5.5°C);\u003cbr\u003e \u003cb\u003eW\/25°C error set to zero J:\u003c\/b\u003e ±3.0°C\u003cbr\u003e \u003cb\u003emaximum (K:\u003c\/b\u003e ±2.0°C)\u003cbr\u003e \u003cb\u003eRepeatability:\u003c\/b\u003e ±0.1°C maximum\u003cbr\u003e \u003cb\u003eLong-Term Drift:\u003c\/b\u003e ±0.1°C\/month max. \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817460310311,"sku":"AD590","price":242.32,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817460343079,"sku":"AD590","price":242.32,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/ad590_l_o59lwqdeqh1yjg6b.jpg?v=1741318779"},{"product_id":"thin-film-platinum-rtd-elements","title":"Thin Film Platinum RTD Elements","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   The F2020 thin film RTD element is a 2.0mm x 2.0mm size. OMEGAFILM platinum thin film RTD elements are manufactured using materials and processes similar to those employed in the manufacture of integrated circuits. This results in a rugged, reliable sensing element that can be produced in a wide range of sizes, resistances, and accuracies to meet even the most demanding of applications.\u003cbr\u003e\u003cbr\u003e OMEGAFILM RTDs conform to the internationally accepted requirements of IEC60751, which defines the resistance vs. temperature characteristics of the sensors, their base resistance at 0°C (32°F), and their accuracy (see below). RTDs conforming to IEC751 have a temperature coefficient of resistance (also known as Alpha) of 0.00385Ohms\/Ohms\/°C between 0 and 100°C.\u003cbr\u003e\u003cbr\u003e As a result of conforming to an internationally recognized standard such as IEC751, OMEGAFILM RTD elements can be used as-is worldwide with a multitude of controllers and instruments designed to function within these requirements. Elements are referred to as pt100, pt500 or pt1000 Ohm configurations \u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"tableWrapPP\"\u003e\u003ctable border=\"0\" cellpadding=\"5\" align=\"right\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"5\"\u003e \u003ctbody\u003e\n\u003ctr bgcolor=\"#F4BBA7\"\u003e \u003cth\u003eClass\u003c\/th\u003e\n\u003cth\u003eTolerance (°C)\u003c\/th\u003e\n\u003cth\u003eTolerance of\u003cbr\u003eresistance at 0°C (Ω)\u003c\/th\u003e\n\u003cth\u003eTemperature\u003cbr\u003eRange\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"center\"\u003e1\/3B (AA)\u003c\/td\u003e \u003ctd align=\"center\"\u003e±(0.1 + 0.0017ItI)\u003c\/td\u003e \u003ctd align=\"center\"\u003e±0.04Ω\u003c\/td\u003e \u003ctd align=\"center\"\u003e0 to 150°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"center\"\u003eA\u003c\/td\u003e \u003ctd\u003e±(0.15 + 0.002ItI)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±0.06Ω\u003c\/td\u003e \u003ctd align=\"center\"\u003e-30 to 300°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"center\"\u003eB\u003c\/td\u003e \u003ctd align=\"center\"\u003e±(0.3 + 0.005ItI)\u003c\/td\u003e \u003ctd align=\"center\"\u003e±0.12Ω\u003c\/td\u003e \u003ctd align=\"center\"\u003e-50 to 500°C\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e OMEGAFILM RTDs are available in flat, round, and specialty shapes for maximum flexibility. They are also available in resistances at 0°C that include 100, 200, 500, and 1000 ohms, depending on the element style (the resistances available for each style will be shown on their individual pages). \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e \u003cb\u003eNote on Assembling Omega \"F\" Series RTD Elements to Extension Wires:\u003c\/b\u003e These RTD elements are made with platinum coated nickel lead wires. Since platinum does not easily wet with most soft solders, we advise that they be spot welded or silver soldered to extension wires when required.  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817460834599,"sku":"F1500-F2000-F4000","price":1434.32,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817460867367,"sku":"F1500-F2000-F4000","price":1434.32,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/f1500_f2000_f4000_l_jyrbtz0ocqx01ws8.jpg?v=1741318820"},{"product_id":"platinum-rtd-capsules","title":"Platinum RTD Capsules","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e Ready to use platinum RTD capsules have insulated lead wires welded and anchored internally. No splicing to fragile elements is required. This construction assures reliable rugged embedment, insertion or probe assembly. Tip diameters from 0.086 to 0.125'. Standard sensors and encapsulation materials rated up to 540°C (1000°F). Choose the moisture resistant version for condensing conditions.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eStandard Lead Length:\u003c\/b\u003e 40 Inches \u003cbr\u003e \u003cb\u003eOperating Temperature Range:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eTFE Leads:\u003c\/b\u003e -200 to 260°C (-320 to 500°F)\u003cbr\u003e     \u003cb\u003ePolyimide Leads:\u003c\/b\u003e -200 to 350°C (-320 to 660°F)\u003cbr\u003e     \u003cb\u003eFiberglass Leads:\u003c\/b\u003e -75 to 510°C (-100 to 950°F)\u003cbr\u003e     \u003cb\u003eMoisture Resistant:\u003c\/b\u003e -50 to 200°C (-60 to 390°F)\u003cbr\u003e \u003cb\u003eSensing Element:\u003c\/b\u003e International grade thin film platinum, a = 0.00385 Ω\/Ω\/°C per IEC 60751\u003cbr\u003e \u003cb\u003eIce Point Resistance:\u003c\/b\u003e 100.00±0.06Ω or 1000.0±0.6Ω at 0°C\u003cbr\u003e \u003cb\u003eTime Constant (Water at 3'\/Second):\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003e0.086 Diameter\u003c\/b\u003e = 0.5 seconds\u003cbr\u003e     \u003cb\u003e0.098 Diameter\u003c\/b\u003e = 0.6 seconds\u003cbr\u003e     \u003cb\u003e0.125 Diameter\u003c\/b\u003e = 0.8 seconds\u003cbr\u003e     \u003cb\u003e0.187 Diameter\u003c\/b\u003e = 1.5 seconds\u003cbr\u003e \u003cb\u003eSelf-Heating:\u003c\/b\u003e Less than 15 mW\/°C\u003cbr\u003e \u003cb\u003eInterchangeability\/Accuracy:\u003c\/b\u003e Class A (±0.15+.002*|t|°C [where |t|= absolute value of temperature in °C]) between -50 and 300°C, Class B above and below these temperatures\u003cbr\u003e \u003cb\u003eLong Term Stability:\u003c\/b\u003e Better than 0.05°C (0.02% of resistance) per 5 years, -50 to 300°C (-58 to 572°F), 0.25°C per year to 540°C (1004°F)\u003cbr\u003e \u003cb\u003eInsulation Resistance:\u003c\/b\u003e Greater than 50 Megohms at 50 Vdc at 25°C (77°F)\u003cbr\u003e \u003cb\u003eMaximum Current:\u003c\/b\u003e 100 Ω = 5 mA, 1000 Ω = 2 mA for limited self-heating; also suitable as self-heated sensors\u003cbr\u003e \u003cb\u003eRecommended Current:\u003c\/b\u003e 1 mA maximum for temperature sensing\u003cbr\u003e \u003cb\u003eCase Materials:\u003c\/b\u003e Alumina on 0.125 and 0.086 diameter, Polyimide [350°C (662°F)] on 0.098 diameter\u003cbr\u003e \u003cb\u003eLead Materials, Nickel-Coated Copper-Insulated:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003e28 AWG Fiberglass:\u003c\/b\u003e Rated to 510°C (950°F)\u003cbr\u003e     \u003cb\u003e28 AWG TFE:\u003c\/b\u003e Rated to 260°C (500°F)\u003cbr\u003e     \u003cb\u003e28 AWG Polyimide:\u003c\/b\u003e Rated to 350°C (660°F) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817461063975,"sku":"RTDCAP","price":636.92,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817461096743,"sku":"RTDCAP","price":636.92,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/rtdcap_l_vlzwqrf8nldq04yo.jpg?v=1741318840"},{"product_id":"cryogenic-silicon-diode-temperature-sensor","title":"Cryogenic Silicon Diode Temperature Sensor","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The CY670 Series silicon diodes offer a more accurate reading of temperature ranges compared to previously marketed silicone diodes. Conforming to the curve CY670 standard voltage vs. temperature response curve, sensors within the CY670 Series are interchangeable, and for many applications they do not require individual calibration. CY670 Series sensors in the SD package are available in 5 tolerance bands–3 for general cryogenic use across the 1.4 to 500 K temperature range, and 1 that offers superior accuracy for applications from 30 K to room temperature. The CY670 Series sensors also come in a tolerance band (E), which is available only as a bare die. For applications requiring greater accuracy, CY670-SD diodes are available with calibration across the full 1.4 to 500 K temperature range.\u003cbr\u003e The CY670E bare die sensor provides the smallest physical size and fastest thermal response time of any silicon diode on the market today. This is an important advantage for applications where size and thermal response time are critical, including focal plane arrays and high temperature superconducting filters for cellular communication. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e \u003cbr\u003e\u003cb\u003eStandard Curve:\u003c\/b\u003e Curve CY670, see chart next page \u003cbr\u003e\u003cb\u003eRecommended Excitation:\u003c\/b\u003e 10 µA, ±0.1% \u003cbr\u003e\u003cb\u003eMax Reverse Voltage:\u003c\/b\u003e 60 V \u003cbr\u003e\u003cb\u003eMax Current Before Damage:\u003c\/b\u003e 1 mA, continuous or 100 mA, pulsed \u003cbr\u003e\u003cb\u003eDissipation at Recommended Excitation:\u003c\/b\u003e 16 µW @ 4.2 K; 10 µW @ 77 K; 5 µW @ 300 K \u003cbr\u003e\u003cb\u003eThermal Response Time:\u003c\/b\u003e SD Model: Typical \u0026lt;10 ms @ 4.2 K, 100 ms @ 77 K, 200 ms @ 305 K \u003cbr\u003e\u003cb\u003eBR Model:\u003c\/b\u003e 1 ms @ 4.2 K, 13 ms @ 77 K, 20 ms @ 305 K \u003cbr\u003e\u003cb\u003eUse in Radiation:\u003c\/b\u003e Recommended for use only in low level radiation \u003cdiv class=\"tableWrapPP\"\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"4\" align=\"right\"\u003e \u003ctbody\u003e\n\u003ctr bgcolor=\"#f6ce8f\"\u003e \u003cth\u003eRange of Use\u003c\/th\u003e \u003cth\u003eLimit Min\u003c\/th\u003e \u003cth\u003eLimit Max\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eCY670-SD\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e1.4 K\u003c\/td\u003e \u003ctd\u003e500 K\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eCY670E-BR\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e1.4 K\u003c\/td\u003e \u003ctd\u003e500 K\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cb\u003eUse in Magnetic Field:\u003c\/b\u003e Not recommended for use in magnetic field applications below 60 K; low magnetic field dependence when used in fields up to 5 tesla above 60 K \u003cbr\u003e\u003cb\u003eReproducibility(*):\u003c\/b\u003e ±10 mK @ 4.2 K \u003cbr\u003e\u003cfont size=\"1\"\u003e(*) Short-term reproducibility data is obtained by subjecting sensor to repeated thermal shocks from 305 to 4.2 K.\u003c\/font\u003e \u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"tableWrapPP\"\u003e\u003ctable border=\"0\" cellspacing=\"10\" cellpadding=\"0\"\u003e \u003ctbody\u003e\n\u003ctr\u003e \u003ctd\u003e\u003cb\u003e\u003clabel for=\"CalibratedAccuracy\"\u003eCalibrated Accuracy\u003c\/label\u003e\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003e\u003clabel for=\"\"\u003eTemperature Response Data Table (typical for CY670)\u003c\/label\u003e\u003c\/b\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"4\" id=\"CalibratedAccuracy\"\u003e \u003ctbody\u003e\n\u003ctr bgcolor=\"#f6ce8f\"\u003e \u003cth\u003eTemperature\u003c\/th\u003e \u003cth\u003eTypical\u003cbr\u003eAccuracy\u003c\/th\u003e \u003cth\u003eLong Term\u003cbr\u003eAccuracy (*)\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e1.4 K \u003c\/td\u003e \u003ctd\u003e±12 mK\u003c\/td\u003e \u003ctd\u003e—\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e4.2 K \u003c\/td\u003e \u003ctd\u003e±12 mK\u003c\/td\u003e \u003ctd\u003e10 mK\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e10 K \u003c\/td\u003e \u003ctd\u003e±12 mK\u003c\/td\u003e \u003ctd\u003e—\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e77 K \u003c\/td\u003e \u003ctd\u003e±22 mK\u003c\/td\u003e \u003ctd\u003e40 mK\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e300 K \u003c\/td\u003e \u003ctd\u003e±32 mK\u003c\/td\u003e \u003ctd\u003e25 mK\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e500 K \u003c\/td\u003e \u003ctd\u003e±50 mK\u003c\/td\u003e \u003ctd\u003e—\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/td\u003e \u003ctd valign=\"top\"\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"4\" id=\"Response\"\u003e \u003ctbody\u003e\n\u003ctr bgcolor=\"#f6ce8f\"\u003e \u003cth\u003eTemperature \u003c\/th\u003e \u003cth\u003eVolts\u003c\/th\u003e \u003cth\u003edV\/dT (mV\/K)\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e1.4 K \u003c\/td\u003e \u003ctd\u003e1.64\u003c\/td\u003e \u003ctd\u003e-12.5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e4.2 K \u003c\/td\u003e \u003ctd\u003e1.58\u003c\/td\u003e \u003ctd\u003e- 31.6\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e10 K \u003c\/td\u003e \u003ctd\u003e1.38\u003c\/td\u003e \u003ctd\u003e-26.8\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e77 K \u003c\/td\u003e \u003ctd\u003e1.03\u003c\/td\u003e \u003ctd\u003e-1.73\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e305 K \u003c\/td\u003e \u003ctd\u003e0.560 \u003c\/td\u003e \u003ctd\u003e-2.30\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003e\u003cb\u003e\u003clabel for=\"Tolerance\"\u003eTolerance Bands for the CY670 Series Diode Thermometer\u003c\/label\u003e\u003c\/b\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"4\" id=\"Tolerance\"\u003e \u003ctbody\u003e\n\u003ctr bgcolor=\"#f6ce8f\"\u003e \u003cth rowspan=\"2\"\u003eBand\u003c\/th\u003e \u003cth colspan=\"4\"\u003eTemperature Tolerance at Temperature Range\u003c\/th\u003e \u003c\/tr\u003e \u003ctr bgcolor=\"#f6ce8f\"\u003e \u003cth\u003e2 to 30 K \u003c\/th\u003e \u003cth\u003e30 to 100 K\u003c\/th\u003e \u003cth\u003e100 to 305 K\u003c\/th\u003e \u003cth\u003e305 to 500 K\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cb\u003eA (1)\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e±0.25 K\u003c\/td\u003e \u003ctd\u003e±0.25 K\u003c\/td\u003e \u003ctd\u003e±0.50 K\u003c\/td\u003e \u003ctd\u003e±0.50 K\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cb\u003eB (2)\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e±0.50 K\u003c\/td\u003e \u003ctd\u003e±0.50 K\u003c\/td\u003e \u003ctd\u003e±0.50 K\u003c\/td\u003e \u003ctd\u003e±0.33% of T\u003cbr\u003e(1.01 to 1.65 K)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cb\u003eC (3)\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e±1.0 K\u003c\/td\u003e \u003ctd\u003e±1.0 K\u003c\/td\u003e \u003ctd\u003e±1.0 K\u003c\/td\u003e \u003ctd\u003e±0.5% of T\u003cbr\u003e(1.53 to 2.50 K)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\n\u003cb\u003eD (4)\u003cbr\u003e(PRT Band)\u003c\/b\u003e \u003c\/td\u003e \u003ctd\u003e±1.5 K \u003c\/td\u003e \u003ctd\u003e±0.25 K\u003c\/td\u003e \u003ctd\u003e±0.30 K\u003c\/td\u003e \u003ctd\u003e±0.1% of T\u003cbr\u003e (0.305 to 0.500 K)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eE\u003cbr\u003e(Bare Chip Band)\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e±1.0\u003c\/td\u003e \u003ctd\u003e K ±0.25 K \u003c\/td\u003e \u003ctd\u003e±0.25% of T\u003cbr\u003e(0.25 to 0.76 K) \u003c\/td\u003e \u003ctd\u003e±0.25% of T\u003cbr\u003e(0.76 to 1.25 K)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817461391655,"sku":"CY670","price":2935.85,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817461424423,"sku":"CY670","price":2935.85,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/cy670_l_oiaycdpotlm1v2sn.jpg?v=1741318861"},{"product_id":"thin-film-platinum-rtd-element-5-packs","title":"Thin Film Platinum RTD Element 5-Packs","description":"\u003cp\u003eThis 5-pack of Thin Film Platinum RTD elements offers consistent, high-stability temperature sensing. The thin-film design provides fast thermal response and excellent reproducibility. Supplied in standard form, they are ideal for OEMs, labs, or calibration setups where multiple sensors are needed, or spare stock is required.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003ePlatinum thin-film RTD element—accurate and stable\u003c\/p\u003e\n\n\u003cp\u003ePack of 5 for replacements or multiple installations\u003c\/p\u003e\n\n\u003cp\u003eQuick thermal response due to thin-film form\u003c\/p\u003e\n\n\u003cp\u003eStandard sizes compatible with most sensor housings or probes\u003c\/p\u003e\n\n\u003cp\u003eReproducible output for consistency across elements\u003c\/p\u003e\n\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\n\u003cp\u003eCalibration labs needing spare RTD elements\u003c\/p\u003e\n\n\u003cp\u003eRepair or replacement of damaged sensors\u003c\/p\u003e\n\n\u003cp\u003eScientific or industrial set-ups where multiple measurement points are used\u003c\/p\u003e\n\n\u003cp\u003eOEM or manufacturing integration\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817461621031,"sku":"5RTD-F3100","price":172.64,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817461653799,"sku":"5RTD-F3100","price":172.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/5rtd-f3100_l_uyqojhtdxh2asbew.jpg?v=1741318884"},{"product_id":"100-pack-thin-film-platinum-rtd-elements","title":"100 Pack Thin Film Platinum RTD Elements","description":"\u003cp\u003eThis pack of 100 thin-film platinum RTD (Resistance Temperature Detector) elements delivers consistent and highly accurate temperature sensing. Ideal for integration into thermostats, industrial probes, or HVAC systems, these RTDs ensure reliable performance in precision control and automated measurement systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003ePack of 100 matched thin-film RTD elements\u003c\/p\u003e\n\n\u003cp\u003eHigh-accuracy resistance-temperature response\u003c\/p\u003e\n\n\u003cp\u003eIdeal for custom thermostat and sensor fabrication\u003c\/p\u003e\n\n\u003cp\u003eConsistent quality for precise measurements\u003c\/p\u003e\n\n\u003cp\u003eStock Up on Precision Sensing Components\n\u003cbr\u003eContact us to order these RTD elements, get pricing, or discuss bulk calibration options.\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817461981479,"sku":"F-Series","price":1608.53,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817462014247,"sku":"F-Series","price":1608.53,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/f_series_l_gdp5z6fwwxwkwgpo.jpg?v=1741318903"},{"product_id":"cryogenic-platinum-rtd-temperature-sensor","title":"Cryogenic Platinum RTD Temperature Sensor","description":"\u003cp\u003eThe Cryogenic Platinum RTD Temperature Sensor is designed for ultra-low temperature sensing, offering reliable and lab-grade accuracy for cryogenic applications. It features 100 Ohm elements suitable for temperatures from -259 to 600°C.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eSuitable for ultra-low temperature applications\u003c\/p\u003e\n\n\u003cp\u003e100 Ohm elements for precise measurements\u003c\/p\u003e\n\n\u003cp\u003eTemperature range from -259 to 600°C\u003c\/p\u003e\n\n\u003cp\u003eLab-grade accuracy\u003c\/p\u003e\n\n\u003cp\u003eCalibration services available\u003c\/p\u003e\n\n\u003ch3\u003eCall to Action:\u003c\/h3\u003e\u003cp\u003eAchieve precise temperature measurements in cryogenic environments with the Cryogenic Platinum RTD Temperature Sensor. Contact us today for more information.\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817462243623,"sku":"PT100-CY82-CYW4-CY100","price":940.22,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817462276391,"sku":"PT100-CY82-CYW4-CY100","price":940.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/pt100_cy82_cyw4_cy100_l_2zanqiaw7ae6ektu.jpg?v=1741318924"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/collections\/F1500_F2000_F4000_l.jpg?v=1741241261","url":"https:\/\/hkcalibrations.com.au\/collections\/temperature-sensing-elements.oembed?page=2","provider":"hkcalibrations","version":"1.0","type":"link"}