{"title":"Temperature and Humidity Data Loggers","description":"\u003cdiv class=\"service-sec pb-5\"\u003e\n\u003cp\u003eTemperature and Humidity data loggers are widely used in a variety of industrial, commercial, and laboratory applications.  These devices are essential tools for ensuring the safety and accuracy of products and processes. They help to monitor and analyze environmental conditions, detect changes in temperature and humidity, and alert personnel when conditions become unsafe. They are also a key component in food production, as they help to monitor the temperature and humidity of food products to prevent spoilage and contamination.\nOmega Engineering offers a wide selection of high-quality and expertly engineered temperature and humidity data loggers – including handheld rechargeable models, chart recorders, and submersible high temperature and pressure loggers.  All of these models are designed for a variety of industries and application and offer accuracy, reliability, and ease-of-use.\n\u003c\/p\u003e\n\u003c\/div\u003e","products":[{"product_id":"six-channel-handheld-rechargeable-temperature-data-logger","title":"Six Channel Handheld Rechargeable Temperature Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\u003cspan class=\"descCopyPP\"\u003e The RDXL6SD-USB is a six-channel touch screen data logger that accepts four thermocouple and two RTD inputs. Each channel has individually configurable HI\/LO alarms. The intuitive touch screen interface allows each channel to be configured separately for input type, math, alarm, and display options. All six channels can be displayed and logged simultaneously or individually. Data can be logged as fast as once a second and is stored on the included 4 GB SD card in Excel compatible format. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInputs:\u003c\/b\u003e 4x thermocouple inputs for use with miniature thermocouple connectors, and 2 x spring clamp terminals for 2 or 3-wire RTDs, 28 to 16 AWG\u003cbr\u003e \u003cb\u003eInput Temperature Range:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eType J:\u003c\/b\u003e -200 to 1200°C\u003cbr\u003e     \u003cb\u003eType K:\u003c\/b\u003e -200 to 1372°C\u003cbr\u003e     \u003cb\u003eType T:\u003c\/b\u003e -200 to 400°C\u003cbr\u003e     \u003cb\u003eType R:\u003c\/b\u003e 0 to 1768°C\u003cbr\u003e     \u003cb\u003eType S:\u003c\/b\u003e 0 to 1768°C\u003cbr\u003e     \u003cb\u003eType N:\u003c\/b\u003e 0 to 1300°C\u003cbr\u003e     \u003cb\u003eType E:\u003c\/b\u003e -200 to 1000°C\u003cbr\u003e     \u003cb\u003eRTD:\u003c\/b\u003e -200 to 850°C\u003cbr\u003e \u003cb\u003eTemperature Accuracy:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eFor Thermocouples:\u003c\/b\u003e ±0.1% or 0.8°C\u003cbr\u003e     \u003cb\u003eFor RTD:\u003c\/b\u003e ±1.0% or 1.0°C\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.1° for temperatures below 1000°C or °F, 1° for temperatures above 1000°C or °F\u003cbr\u003e \u003cb\u003eDisplay:\u003c\/b\u003e 72 mm (2.83\") resistive touch TFT, 320 x 240 pixels, backlit\u003cbr\u003e \u003cb\u003eConfigurable Parameters:\u003c\/b\u003e Temperature units, alarms, signal processing, date and time, data logging, power options, graph channels\u003cbr\u003e \u003cb\u003eTemperature Units:\u003c\/b\u003e °F or °C\u003cbr\u003e \u003cb\u003eAlarm Configuration:\u003c\/b\u003e 12 x alarms (2 per channel) with adjustable level, individually configurable as HI or LO\u003cbr\u003e \u003cb\u003eSignal Processing:\u003c\/b\u003e Average, minimum, maximum, standard deviation, 2-channel temperature difference\u003cbr\u003e \u003cb\u003eDisplay Response Time:\u003c\/b\u003e 1 second\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e 0 to 50°C (32 to 122°F)\u003cbr\u003e \u003cb\u003ePower Supplies:\u003c\/b\u003e Built-in rechargeable battery, USB, or 5 Vdc adaptor (included)\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 32 hour logging with full display brightness; up to 96 hours while logging in power saving mode\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 200 g (7 oz) without thermocouples\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 136 W x 71 H x 32 D mm (5.35 x 2.8 x 1.25\")\u003cbr\u003e \u003cb\u003eData Logging Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eData Logging Interval:\u003c\/b\u003e 1 to 86,400 seconds (1 day)\u003cbr\u003e \u003cb\u003eMaximum SD Card Capacity:\u003c\/b\u003e 32 GB SD Card (4 GB included)\u003cbr\u003e \u003cb\u003eVariables Logged:\u003c\/b\u003e Measured temperature, cold junction temperature, alarm events\u003cbr\u003e \u003cb\u003eFile Format:\u003c\/b\u003e .csv (can be imported to Excel)\u003cbr\u003e \u003cb\u003eConfigurable Parameters:\u003c\/b\u003e Sample period, number of samples, scheduled start date and time \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817395560743,"sku":"RDXL6SD-USB-Series","price":1437.8,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817395593511,"sku":"RDXL6SD-USB-Series","price":1437.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/rdxl6sd-usb_l_ixbc0s0rmspfyh5y.jpg?v=1741315723"},{"product_id":"chart-recorder-for-temperature-and-humidity","title":"Chart Recorder for Temperature \u0026 Humidity","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cb\u003eView Temperature + Humidity With A Web Browser\u003c\/b\u003e \u003cbr\u003e The OMEGA™ \u003cb\u003eiTHX-SD\u003c\/b\u003e transmitter lets you monitor and record Temperature, Relative Humidity and Dew Point over an Ethernet network or the Internet with no special software except a Web Browser.\u003cbr\u003e \u003cbr\u003e The iTHX-SD serves Active Web Pages to display real-time readings, display charts of temperature and humidity, or log data in standard data formats for use in a spreadsheet or data acquisition program such as Excel or Visual Basic. The virtual chart viewed on the web page is a JAVA™ Applet that records a chart over the LAN or Internet in real-time. With the iTHX-SD, there is no need to invest time and money learning a proprietary software program to log or chart the data. \u003cbr\u003e  \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cbr\u003e \u003cb\u003eSD Flash Memory Card\u003c\/b\u003e \u003cbr\u003e The iTHX-SD comes complete with a removable SD Flash Memory card that can store up to years of readings taken at ten second intervals. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eRecords on SD Flash Cards\u003c\/b\u003e \u003cbr\u003e The data is recorded on widely available SD (Secure Digital) flash cards. The format is a simple text file that is easily imported to spread sheets and other programs. It can be read on a PC or MAC with a USB card reader. You can also download the data remotely over an Ethernet network or the Internet. \u003cbr\u003e \u003cbr\u003e \u003c\/font\u003e\u003c\/td\u003e \u003ctd align=\"left\" valign=\"top\"\u003e\u003cdiv class=\"mobileContentWrap\"\u003e\u003cdiv class=\"mobileContentWrap\"\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd align=\"left\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cb\u003eAlarm Relays\u003c\/b\u003e \u003cbr\u003e The iTHX-SD features two 1.5 Amp relays. With the easy Web-based setup page, the two relays can be programmed for any combination of temperature or humidity, and high or low set points. The relays can also be programmed to remain latched and require a manual reset if a limit is exceeded. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eBattery Backup\u003c\/b\u003e \u003cbr\u003e The iTHX-SD comes with a universal 100 to 240 Vac power adapter. A standard 9 Volt Alkaline battery (also included) allows the device to log data for up to 2 days without external ac power. A failure on the Ethernet network will not interrupt data recording. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eAdjustable Charts\u003c\/b\u003e \u003cbr\u003e Chart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity can be charted across the full span (-40 to 124°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C). When a second sensor is added, users can select a chart that records channel 1, channel 2, or the difference of the two channels. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eAward-Winning Technology\u003c\/b\u003e\u003cbr\u003e The iTHX-SD is simple to install and use, and features OMEGA's award-winning iServer technology that requires no special software except a Web Browser. The iTHX-SD connects to an Ethernet Network with a standard RJ45 connector and sends data in standard TCP\/IP packets. It is easily configured with a simple menu using a Web Browser and can be password protected. From within an Ethernet LAN or over the Internet, the user simply types its IP address or an easy to remember name such as \"Cleanroom5\" or \"ServerRoom\" in any Web Browser, and the iTHX-SD serves a Web Page with the current readings. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eEmail Alarms\u003c\/b\u003e\u003cbr\u003e All iTHX-SD models that are on a LAN that is connected to the Internet can trigger an alarm that can be sent by email to a user or a distribution list anywhere in the world, including text messages to cell phones and PDA's. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eLink to Web CAM or IP Camera\u003c\/b\u003e\u003cbr\u003e The Web page includes a link to a “Web Cam” or “IP camera” (not included). If you get a message about an alarm condition, you can quickly click on the link to view the actual scene over the Internet. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eDisplay and Chart Two Channels\u003c\/b\u003e \u003cbr\u003e The iTHX-SD transmitters come complete with a temperature and humidity probe for measurement of a single location. With the addition of a second probe, the iTHX-SD transmitter can measure and display temperature, humidity and dew point in a second location up to ten feet away. The transmitter can display and chart absolute measurements in both locations, or a differential measurement between the two locations. The second probe requires no change to the basic iTHX-SD transmitter hardware, it can be added at the time of purchase or in the future. Omega offers a choice of industrial probes in 2\" and 5\" lengths, and a wand style for ambient indoor applications. A simple DB-9 \"Y\" connector is available for adding a second probe. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eSensor and Calibration\u003c\/b\u003e \u003cbr\u003e It is not necessary to take the iTHX-SD out of service for routine calibration. The temperature \/ humidity sensors are interchangeable and can be replaced for about the same cost as a typical calibration. Omega offers replacement sensors with optional 3-point NIST traceable calibration certificates. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eTypical Applications\u003c\/b\u003e\u003cbr\u003e The iTHX-SD is great for monitoring temperature + humidity in applications such as: clean rooms, computer rooms, HVAC systems, pharmaceutical and food processing and storage, hospitals, laboratories, semiconductor fabs, electronic assembly, warehousing, museums, manufacturing, greenhouses, farm animal shelters, and many more. \u003cbr\u003e \u003cbr\u003e \u003c\/font\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cb\u003e\u003cfont color=\"#FF0000\"\u003eSPECIFICATIONS\u003c\/font\u003e\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eSENSOR SPECIFICATIONS\u003c\/b\u003e \u003cbr\u003e \u003cbr\u003e \u003cdiv class=\"mobileContentWrap\"\u003e\u003cdiv class=\"mobileContentWrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/accuracy.png?v=1741315732\" border=\"0\" alt=\"Accuracy\"\u003e\u003c\/div\u003e\u003c\/div\u003e \u003c\/font\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cb\u003eRELATIVE HUMIDITY (RH)\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eAccuracy\/Range at 25°C- Non-Condensing:\u003c\/b\u003e \u003cbr\u003e ±2.75% for 10 to 90% \u003cbr\u003e ±3% for 5 to 10% and 90 to 95% \u003cbr\u003e ±4% for 0 to 5% and 95 to 100% \u003cbr\u003e \u003cb\u003eNon-linearity:\u003c\/b\u003e ±3% \u003cbr\u003e \u003cb\u003eHysteresis:\u003c\/b\u003e ±1% RH \u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e 8 seconds, tau 63% \u003cbr\u003e \u003cb\u003eRepeatability:\u003c\/b\u003e ±0.1% \u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.1%, 12 bit \u003cbr\u003e \u003cbr\u003e \u003cb\u003eDEWPOINT\u003c\/b\u003e -90 to 125°C (-130 to 257°F) \u003cbr\u003e \u003cbr\u003e \u003cb\u003ePROBE DIMENSIONS\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eWand Probe iTHP-W-6:\u003c\/b\u003e \u003cbr\u003e 19.1mm Diameter x 198mm Long (0.75\" x 7.8\") \u003cbr\u003e Cable with DB9 connector: 152mm Long (6\") \u003cbr\u003e Cable operating temperature: 0 to 80°C (32 to 176°F) \u003c\/font\u003e\u003c\/td\u003e \u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cb\u003eTEMPERATURE(T)\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eAccuracy\/Range*:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eWand Probe:\u003c\/b\u003e \u003cbr\u003e ±0.5°C for 5 to 45°C (±1°F for 41° to 113°F); \u003cbr\u003eup to ±1°C for 0 to 5°C and 45 to 60°C \u003cbr\u003e(up to ±2°F for 32 to 41°F and 113 to 140°F) \u003cbr\u003e \u003cb\u003eIndustrial Probe:\u003c\/b\u003e \u003cbr\u003e ±0.5°C for 5 to 45°C (±1°F for 41 to 113°F); \u003cbr\u003eup to ±1.5°C for -40 to 5°C and 45 to 124°C \u003cbr\u003e(up to ±2.7°F for -40 to 41°F and 113 to 255°F) \u003cbr\u003e(see chart) \u003cbr\u003e \u003cb\u003e\u003ci\u003e*Note:\u003c\/i\u003e\u003c\/b\u003e\u003ci\u003e extended temperature range is for Industrial Probe only, the iServer's operating temp. is 0 to 60 °C.\u003c\/i\u003e \u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e 5 to 30 seconds, tau 63% \u003cbr\u003e \u003cb\u003eRepeatability:\u003c\/b\u003e ±0.1°C \u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.1°C, 14 bit \u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cb\u003eIndustrial Probe iTHP-2, iTHP-5:\u003c\/b\u003e \u003cbr\u003e 16mm Diameter x 51mm Long (0.63\" x 2\") or \u003cbr\u003e 16mm Diameter x 137mm Long (0.63\" x 5\") \u003cbr\u003e Cable with DB9 connector: 0.9m Long (3') or \u003cbr\u003e Cable with DB9 connector: 3m Long (10') \u003cbr\u003e Cable operating temperature: -40 to 125°C \u003cbr\u003e (-40 to 257°F) \u003c\/font\u003e\u003c\/td\u003e \u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cb\u003eOptional and Standard Caps for Probes\u003c\/b\u003e \u003cbr\u003e One porous polyethylene cap \u003cb\u003eIP-PCI\u003c\/b\u003e or \u003cb\u003eIP-PCW\u003c\/b\u003e (depending on your probe type) is included with each probe. An optional stainless steel cap \u003cb\u003eIP-SC\u003c\/b\u003e is available for industrial probes.\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cbr\u003e \u003cb\u003eiSERVER SPECIFICATIONS\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eInterfaces\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eEthernet (RJ45):\u003c\/b\u003e Fixed or autonegotiating 10\/100BASE-T, Auto MDI\/MDIX\u003cbr\u003e \u003cb\u003eSensor:\u003c\/b\u003e Digital 4-wire (DB-9) \u003cbr\u003e \u003cb\u003eSupported Protocols\u003c\/b\u003e \u003cbr\u003e TCP, UDP, SNMP, SMTP, NTP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet \u003cbr\u003e \u003cb\u003eLCD Display\u003c\/b\u003e \u003cbr\u003e 16 Digits 6mm (0.23\") \u003cbr\u003e \u003cb\u003eSD Flash Memory Card\u003c\/b\u003e \u003cbr\u003e 2GB card: 8 months of data storage at 1 second recording intervals or 7 years at 10 second intervals \u003cbr\u003e \u003cb\u003eRelay Outputs\u003c\/b\u003e \u003cbr\u003e Two Relays 1.5A @ 30 Vdc \u003cbr\u003e \u003cb\u003eManagement\u003c\/b\u003e \u003cbr\u003e Device configuration and monitoring through embedded WEB server \u003cbr\u003e \u003cb\u003eEmbedded WEB Server\u003c\/b\u003e \u003cbr\u003e Serves WEB pages containing real-time data and live updated charts within definable time intervals. \u003cbr\u003e \u003cbr\u003e \u003c\/font\u003e\u003c\/td\u003e \u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eiServer Unit:\u003c\/b\u003e 0 to 60°C (32 to 140°F) \u003cbr\u003e \u003cb\u003eac Power Adapter:\u003c\/b\u003e 0° to 40°C (32° to 104°F) \u003cbr\u003e \u003cb\u003eBack-up Battery:\u003c\/b\u003e -18 to 55°C (-0.4 to 131°F) \u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185 °F) \u003cbr\u003e \u003cbr\u003e \u003cb\u003ePACKAGING\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eMaterial:\u003c\/b\u003e Steel metal case with wall mount bracket \u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e Refer to iTHX-SD Mechanical Section \u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 0.389 kg (0.86 lbs.) \u003cbr\u003e \u003cbr\u003e \u003cb\u003eAGENCY APPROVALS:\u003c\/b\u003e CE FCC-B \u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cb\u003ePOWER\u003c\/b\u003e \u003cbr\u003e \u003cb\u003ePower Input:\u003c\/b\u003e 9 to 12 Vdc \u003cbr\u003e \u003cb\u003eConsumption:\u003c\/b\u003e 3.5 W \u003cbr\u003e \u003cb\u003eSafety Qualified ac Power Adapter (included)\u003c\/b\u003e \u003cbr\u003e \u003cb\u003e Nominal Output:\u003c\/b\u003e 9 Vdc @ 0.5 A \u003cbr\u003e \u003cb\u003e Input:\u003c\/b\u003e 100 to 240 Vac, 50\/60 Hz \u003cbr\u003e \u003cb\u003eBack-up Battery:\u003c\/b\u003e 9Vdc, Alkaline \u003c\/font\u003e\u003c\/td\u003e \u003ctd width=\"340px\" align=\"left\" valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cdiv class=\"mobileContentWrap\"\u003e\u003cdiv class=\"mobileContentWrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/univ_ac_sm_0812.jpg?v=1741315736\" border=\"0\" alt=\"Universal ac Power Adapter\"\u003e\u003c\/div\u003e\u003c\/div\u003e \u003cbr\u003e \u003cb\u003eUniversal ac Power Adapter\u003c\/b\u003e \u003cbr\u003e \u003cbr\u003e \u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\" align=\"left\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" align=\"center\" valign=\"top\"\u003e\n\u003ca name=\"cal\"\u003e\u003c\/a\u003e \u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\" color=\"red\"\u003e\u003cb\u003eREPLACEMENT PROBES \u0026amp; CALIBRATION CERTIFICATES\u003c\/b\u003e\u003c\/font\u003e \u003cbr\u003e \u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e\u003cb\u003eNo need to take your unit out of service to get re-calibrated, order a calibrated probe instead.\u003c\/b\u003e\u003c\/font\u003e\n\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\" valign=\"bottom\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cdiv class=\"mobileContentWrap\"\u003e\u003cdiv class=\"mobileContentWrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/3PROBEs_all_0912.png?v=1741315740\" border=\"0\" alt=\"Protective Caps\"\u003e\u003c\/div\u003e\u003c\/div\u003e \u003cbr\u003e \u003cbr\u003e \u003cb\u003eOptional Probe Caps shown, \u003cbr\u003efits industrial or wand probe\u003c\/b\u003e \u003c\/font\u003e\u003c\/td\u003e \u003ctd align=\"center\" valign=\"bottom\"\u003e\n\u003cdiv class=\"mobileContentWrap\"\u003e\u003cdiv class=\"mobileContentWrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/nistcert_0812.jpg?v=1741315745\" border=\"0\" alt=\"NIST Certificate\"\u003e\u003c\/div\u003e\u003c\/div\u003e \u003cbr\u003e \u003cbr\u003e \u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e\u003cb\u003eGet a NIST Traceable Calibration Certificate \u003cbr\u003ewith your Calibrated Replacement Probe.\u003c\/b\u003e\u003c\/font\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003cscript type=\"application\/ld+json\"\u003e     {\"@context\": \"https:\/\/schema.org\",\"@type\": \"FAQPage\",\"mainEntity\": [{\"@type\": \"Question\",\"name\": \"Previous Omega Model DPiTH Serial RS-232 let us read Humidity through *X01 and Temperature through *X02 queries. Does Telnet interface on ITHX-SD-5 model support same queries or equivalent to read Temp and\/or Hum directly through SCPI queries?\",\"acceptedAnswer\": {  \"@type\": \"Answer\",  \"text\": \"Thank you for your question. The command queries for the ITHX device are different. Please refer to section 4.91 of manual you can download from our website.\r\nhttps:\/\/www.omega.com\/en-us\/iiot-wireless\/ithx-sd-series\/p\/ITHX-SD\"}},{\"@type\": \"Question\",\"name\": \"I would like to know the administrator password for a device THX-SD 18240420\",\"acceptedAnswer\": {  \"@type\": \"Answer\",  \"text\": \"admin=00000000\r\nuser=12345678\"}},{\"@type\": \"Question\",\"name\": \"I have iTHX-SD-2, M21210492. With a humidity probe tip of iTHP-2-DB9. the probe is using an RS232 to connect the display reader.  Do you sell a probe with a longer cable?\",\"acceptedAnswer\": {  \"@type\": \"Answer\",  \"text\": \"Thank you for your question. Yes it is: https:\/\/www.omega.com\/en-us\/data-acquisition\/data-acquisition-modules\/p\/ITHP-5-DB9\"}},{\"@type\": \"Question\",\"name\": \"Where can I get latest firmware for the ithx-sd?\",\"acceptedAnswer\": {  \"@type\": \"Answer\",  \"text\": \"Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM\u0026rdquo;\"}},{\"@type\": \"Question\",\"name\": \"I have iTHX-SD-2, M21210492. With a humidity probe tip of iTHP-2-DB9. the probe is using an RS232 to connect the display reader. Can I add and RS232 to RS232 extension to extend it? Or do I need to buy a probe with a longer neck?\",\"acceptedAnswer\": {  \"@type\": \"Answer\",  \"text\": \"Thank you for your question. Yes you can extend the cable but the accuracy may be affected.\"}}]     }     \u003c\/script\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817396052263,"sku":"ITHX-SD-Series","price":1492.31,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817396085031,"sku":"ITHX-SD-Series","price":1492.31,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/ithx-sd_ovvlriz93tpvcoez.jpg?v=1741315764"},{"product_id":"portable-temperature-humidity-data-loggers-with-usb-interface","title":"Portable Temperature\/Humidity Data Loggers with USB Interface","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\"\u003e The OM-140 Series are low-cost, compact, battery powered temperature\/humidity data loggers capable of unattended logging (recording) of the ambient temperature and relative humidity (RH) of an environment for days, weeks or months. The OM-144 data logger can also measure and optionally log surface temperatures spot-checked by a technician using the unit’s integral infrared (IR) thermometer. In addition, these units can also calculate and display absolute humidity levels in units of grains per pound (GPP) or g\/kg. Also called mixing ratio, GPP is a more useful moisture metric than RH to water damage restorers. Using RH alone, a restorer might unknowingly introduce moist air—with a low RH but a high GPP—during a job’s drying phase.\u003cbr\u003e\u003cbr\u003e Data logging can be started or stopped by pushing a button on the unit, eliminating the need to bring a laptop to the job site. After a data log has been captured and stored, it can be uploaded as a .txt file to any PC running the Windows\u003csup\u003e®\u003c\/sup\u003e XP\/7 or 8 operating system after plugging the data logger into one of the computer’s USB ports. The data logger’s internal flash memory is large enough to store 16,300 pairs of temperature and RH readings or for the model OM-144 nearly 10,000 sets of RH, ambient temperature and surface temperature readings. Included with the product is a mini-disc with the drivers needed to interface the unit to the computer, as well as software that can display a data log file as a table or graph and\/or export it to Microsoft Excel. Exporting to Excel is recommended for sophisticated trending and analysis of humidity and temperature data and easy detection of unexpected excursions. \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817396281639,"sku":"OM-140-Series","price":206.5,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817396314407,"sku":"OM-140-Series","price":206.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-140-series_l_hqsqltpvfrdscenj.jpg?v=1741315787"},{"product_id":"four-channel-temperature-data-logger-with-graphing-display","title":"Four Channel Temperature Data Logger with Graphing Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\"\u003e The OM-DVT4 temperature data logger with display is an easy-touse, versatile device which can be used for a wide range of logging applications. The OM-DVT4 records and instantly displays trends for up to 4 temperatures using one internal and three external sensors. The large, clear display shows all channels simultaneously, as well as the temperature difference between channels. When you’re ready, download up to 87,000 data points to your PC for further analysis. \u003cbr\u003e\u003cbr\u003e Data logging has never been this visual! The OM-DVT4 is capable of sampling as fast as once per second or as slow as every 18 hours. A total of 87,040 temperature measurements can be stored in the data logger memory (21,760 measurements per channel). Visual over and under temperature alarm indicators are available for all four channels. \u003cbr\u003e\u003cbr\u003e Easy-to-use Windows software is included with the OM-DVT4. The software is a full-featured program that allows you to set up all data logger functions including sampling rate, logging duration, start mode, logging mode, and high and low temperature alarm values. Once data has been logged, the program then allows you to download data from the logger, plot the data and export the data to an ASCII text or Excel file format for further analysis. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e DATA LOGGER\u003cbr\u003e Internal Probe Temperature Range:\u003c\/b\u003e -10 to 65°C (15 to 150°F)\u003cbr\u003e \u003cb\u003eExternal Probe Temperature Range:\u003c\/b\u003e -40 to 70°C (-40 to 160°F)\u003cbr\u003e \u003cb\u003eTemperature Accuracy:\u003c\/b\u003e ±0.5°C (1°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.1°F or 0.1°C\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±100 ppm @ 75°F\u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e User single point offset calibration is available through software for all temperature channels. Calibration can be password protected.\u003cbr\u003e \u003cb\u003eSample Rate:\u003c\/b\u003e User selectable 1 second to 18 hour\u003cbr\u003e \u003cb\u003eSample Storage Capacity:\u003c\/b\u003e 21,760 points for 4 temperatures, 29,013 points for 3 temperatures,\u003cbr\u003e 43,520 points for 2 temperatures, 87,040 points for single temperature.\u003cbr\u003e \u003cb\u003eAlarms:\u003c\/b\u003e Visual over and under alarm indicator for all 4 channels\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e Three “AA” batteries (included)\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 1 year continuous use, 2 years average use. The logger automatically turns itself OFF after 1 hour, when not logging. Turn ON by pressing any button.\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -10 to 65°C (15 to 150°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -20 to 70°C (-5 to 160°F)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 7.7 H x 10.2 W x 3.8 cm D (3.05 x 4 x 1.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 200 g (7.0 oz)\u003cbr\u003e \u003cbr\u003e \u003cb\u003eEXTERNAL PROBES\u003cbr\u003e Number of Channels:\u003c\/b\u003e 3\u003cbr\u003e \u003cb\u003eProbe Cable Length:\u003c\/b\u003e 4.6 m (15'), PVC insulation\u003cbr\u003e \u003cb\u003eProbe Tip Material:\u003c\/b\u003e Nickel plated brass\u003cbr\u003e \u003cb\u003eProbe Tip Dimensions:\u003c\/b\u003e 5 cm (2\") L, 5 mm (0.2\") dia \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSOFTWARE\u003cbr\u003e PC Interface:\u003c\/b\u003e USB port; USB cable is included\u003cbr\u003e \u003cb\u003eSampling Interval:\u003c\/b\u003e User selectable from 1 second to 18 hours, in 1 sec increments\u003cbr\u003e \u003cb\u003eData Security:\u003c\/b\u003e Unique factory set logger ID. Recording session counter. Password protected calibration.\u003cbr\u003e \u003cb\u003eOperating System Compatibility:\u003c\/b\u003e Windows® XP SP2\/Vista\/7 and 8 (32-bit and 64-bit)\u003cbr\u003e \u003cb\u003eMinimum System Requirements:\u003c\/b\u003e 5 MB of free disk space, 800 x 600 screen resolution, \u003cbr\u003e1 free USB port.\u003cbr\u003e \u003cb\u003eRecording Start:\u003c\/b\u003e On button press, immediate after setup, or at a user specified date and time.\u003cbr\u003e \u003cb\u003eRecording Mode Stop:\u003c\/b\u003e On memory full, or continuous recording with memory rollover\u003cbr\u003e \u003cb\u003eReal Time Status:\u003c\/b\u003e Visual indication through the status LED. Software real time status.\u003cbr\u003e \u003cb\u003eUser Calibration:\u003c\/b\u003e Password protected calibration for each channel\u003cbr\u003e \u003cb\u003eUser Information:\u003c\/b\u003e Up to 30 characters\u003cbr\u003e \u003cb\u003eLogger Channels:\u003c\/b\u003e User selectable. Disabling channels increases the storage capacity \u003cbr\u003eof the other channels.\u003cbr\u003e \u003cb\u003eUnits:\u003c\/b\u003e US and Metric\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Exportable to text or Excel files \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817396511015,"sku":"OM-DVT4-Logger","price":866.74,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817396543783,"sku":"OM-DVT4-Logger","price":866.74,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-dvt4_l_a6omm8tpkksearkl.jpg?v=1741315812"},{"product_id":"4-channel-7-thermocouple-types-datalogger-usb-output","title":"4 Channel 7 Thermocouple Types Datalogger USB output","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"overflow-content\"\u003e\n\u003cp\u003eThe HH1385 is a digital 4 input thermometer and data logger that works with any K, J, E, T, R, S, N type thermocouple temperature sensors (Please refer to the specifications table below). This unit offers higher accuracy and better uniformity across various thermocouple types. This device measures\/stores over 16,800 temperature readings and allows up to 4 thermocouple connections that plug into a miniature female thermocouple receptacle at the base of the unit. The user can easily set up the initial data logging parameters including thermocouple type, logging Intervals, high\/low alarm settings, and desired temperature units (°C,°F or °K). The user may also download the stored data by plugging the meter straight into a PC’s USB port and running the easy-to-use Windows software.\u003c\/p\u003e \u003cbr\u003e \u003ch2 style=\"text-align: center;\"\u003eSpecification Table\u003c\/h2\u003e \u003cdiv class=\"overflow-content\"\u003e\n\u003ctable border=\"1\" style=\"width: 80%; border-color: black; margin-left: auto; margin-right: auto;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"border-color: black;\"\u003e\n\u003cth rowspan=\"6\" valign=\"center\" style=\"border-color: black; text-align: center; vertical-align: middle;\"\u003e \u003cp align=\"center\"\u003e Range\u003c\/p\u003e \u003c\/th\u003e \u003ctd style=\"text-align: center;\"\u003eK\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e-200°C to +1372°C (-328°F to +2501°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003eJ\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e-210°C to +1200°C (-346°F to +2192°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003eT\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e-250°C to +400°C (-418°F to +752°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003eE\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e-210°C to +1000°C (-346°F to +1832°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003eR\/S\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e-0°C to +1767°C (-32°F to +3212°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003eN\u003c\/td\u003e \u003ctd style=\"text-align: center;\"\u003e-150°C to +1300°C (-238°F to +2372°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003cth rowspan=\"2\" align=\"center\" style=\"background-color: #f8f8f8; text-align: center; vertical-align: middle;\"\u003e \u003cp align=\"center\"\u003e Resolution\u003c\/p\u003e \u003c\/th\u003e \u003ctd style=\"background-color: #f8f8f8; text-align: center;\"\u003e0.1\u003c\/td\u003e \u003ctd style=\"background-color: #f8f8f8; text-align: center;\"\u003eK \/ J \/ T \/ E \/ N \/ R \/ S ≤ 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003ctd style=\"background-color: #f8f8f8; text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"background-color: #f8f8f8; text-align: center;\"\u003eR \/ S and K \/ J \/ E \/ N ≥ 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003cth rowspan=\"2\" align=\"center\" style=\"text-align: center; vertical-align: middle;\"\u003e \u003cp align=\"center\"\u003e Accuracy\u003c\/p\u003e \u003c\/th\u003e \u003ctd colspan=\"4\" height=\"60\" align=\"center\"\u003eK\/J\/E\/T\/N type: ±(0.05% rdg + 0.7°C\/1°F) \u003cbr\u003e Below -100°C(-148°F) \u003cbr\u003e K,J,T,E: +0.15% reading \u003cbr\u003e N: +0.45% reading\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\u003ctd colspan=\"4\" align=\"center\"\u003eR\/S Type: ±(0.05% rdg + 3°C\/5.4°F)\u003c\/td\u003e\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003cth align=\"center\" style=\"background-color: #f8f8f8; text-align: center; vertical-align: middle;\"\u003e \u003cp align=\"center\"\u003e Temperature coefficient\u003c\/p\u003e \u003c\/th\u003e \u003ctd colspan=\"4\" style=\"background-color: #f8f8f8;\"\u003e0.05% of reading ±.07°C per °C outside the specified 18 to 28°C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003cth align=\"center\" style=\"text-align: center; vertical-align: middle;\"\u003e \u003cp align=\"center\"\u003e Temperature scale\u003c\/p\u003e \u003c\/th\u003e \u003ctd colspan=\"4\"\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003cth align=\"center\" style=\"background-color: #f8f8f8; text-align: center; vertical-align: middle;\"\u003e \u003cp align=\"center\"\u003e Operation Temperature and Humidity\u003c\/p\u003e \u003c\/th\u003e \u003ctd colspan=\"4\" style=\"background-color: #f8f8f8;\"\u003e0°C to 50°C (32°F to +122°F), \u0026lt;80%RH\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr style=\"border-color: black;\"\u003e\n\u003cth align=\"center\" style=\"text-align: center; vertical-align: middle;\"\u003e \u003cp align=\"center\"\u003e Storage Temperature and Humidity\u003c\/p\u003e \u003c\/th\u003e \u003ctd colspan=\"4\"\u003e0°C to 50°C, relative humidity under 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp style=\"text-align: center;\"\u003eAccuracy is specified for ambient temperatures between 18 to 28°C (64 to 82°F)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817396838695,"sku":"HH1384-Series","price":1066.76,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817396871463,"sku":"HH1384-Series","price":1066.76,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/hh1385_450_2u5iwwzlfoxejwam.jpg?v=1741315836"},{"product_id":"portable-temperature-and-humidity-data-logger-with-lcd-display","title":"Portable Temperature and Humidity Data Logger with LCD Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e \u003cspan style=\"float:right; margin:10px;\"\u003e \u003ciframe width=\"400\" height=\"280\" src=\"https:\/\/www.youtube.com\/embed\/gwEGoChZDPQ\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003cbr\u003e \u003ccenter\u003e\u003cb\u003eOM-HL-SH Operation Instruction\u003c\/b\u003e\u003c\/center\u003e \u003c\/span\u003e The OM-HL-SH Series of portable temperature and temperature\/humidity data loggers are easy-to use, versatile and price competitive devices which can be used for a wide range of logging applications including coolers, freezers, greenhouses, museums, laboratories, shipping containers, warehouses, environmental monitoring and food storage. \u003cbr\u003e\u003cbr\u003e With 100~200ms sensor response time, these data loggers are capable of sampling as fast as 1 second and logging between once every 2 seconds to 24 hours. Both Models OM-HL-SH-T and OM-HL-SH-TH can store a total of 43,000 temperature only or 43,000 temperature \u0026amp; 43,000 humidity measurements in memory. Excellent user experience and cost effective makes this OM-HL-SH series one of the best temperature\/humidity logging solutions in the market.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e NIST Traceable calibration model OM-HL-SH-TH-CAL is available to order as well as the external probe model OM-HL-SH-EX coming with standard 3 meter long IP65 temperature and humidity probe. See the following picture of EX model.\u003cbr\u003e\u003cbr\u003e  \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature Range:\u003c\/b\u003e\u003cbr\u003e OM-HL-SH-T: -20 to 70°C (-22 to 158°F)\u003cbr\u003e OM-HL-SH-TH: -20 to 70°C (-22 to 158°F)\u003cbr\u003e OM-HL-SH-EX: -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eTemperature Accuracy:\u003c\/b\u003e\u003cbr\u003e OM-HL-SH-T: ±0.5°C\u003cbr\u003e OM-HL-SH-TH: ±0.5°C\u003cbr\u003e OM-HL-SH-EX: ±0.5°C\u003cbr\u003e \u003cb\u003eRecord Volume:\u003c\/b\u003e 43,000 Temperature Points (OM-HL-SH-T) or 43,000 Temperature \u0026amp; 43,000 Humidity Points (OM-HL-SH-TH \u0026amp; OM-HL-SH-EX)\u003cbr\u003e \u003cb\u003eHumidity Range:\u003c\/b\u003e\u003cbr\u003e OM-HL-SH-TH: 0-95% RH\u003cbr\u003e OM-HL-SH-EX: 0-100% RH\u003cbr\u003e \u003cb\u003eHumidity Accuracy:\u003c\/b\u003e\u003cbr\u003e OM-HL-SH-TH: ±5% RH\u003cbr\u003e OM-HL-SH-EX: ±5% RH\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e Temperature: 0.1°C \/ Humidity: 0.1% RH\u003cbr\u003e \u003cb\u003ePower Supply:\u003c\/b\u003e 2 x AAA Batteries, 1.5V Battery\u003cbr\u003e \u003cb\u003eTypical Battery Life:\u003c\/b\u003e 1 year\u003cbr\u003e \u003cspan style=\"float:right; margin:10px;\"\u003e \u003ciframe width=\"400\" height=\"280\" src=\"https:\/\/www.youtube.com\/embed\/KqVA4QXjWQw\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003cbr\u003e \u003ccenter\u003e\u003cb\u003eOM-HL-SH Software Setup\u003c\/b\u003e\u003c\/center\u003e \u003c\/span\u003e \u003cb\u003eLogging Mode:\u003c\/b\u003e Stop on memory full; when data logger operation is start\/stopped by user intervention via button press, last memory location is retained\u003cbr\u003e \u003cb\u003eLogging Interval:\u003c\/b\u003e 2 Secs to 24 Hrs\u003cbr\u003e \u003cb\u003eSampling Interval:\u003c\/b\u003e 1 Sec to 240 Secs\u003cbr\u003e \u003cb\u003eSensor Response Time:\u003c\/b\u003e 100~200ms\u003cbr\u003e \u003cb\u003eDisplay:\u003c\/b\u003e LCD display\u003cbr\u003e \u003cb\u003eLCD Size:\u003c\/b\u003e 36 L x 16 W mm (1.41 x 0.6\")\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 92 L x 57 W x 20 Dia mm (3.6 x 2.2 x 0.78\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 150g (5.29 oz)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eLogpro Recorder Analysis Software\u003c\/b\u003e\u003cbr\u003e OM-HL Logpro Software is comprehensive temperature and humidity recorder data analysis software designed to log attribute settings, download logger data efficiently, graphically analyze data, and export the data to Excel\/PDF\/BMP, and other formats.\u003cbr\u003e\u003cbr\u003e The software interface is easy to use and efficient for ultimate data analysis. See the software instruction video for more details \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e \u003cb\u003eScreen Shot of OM-HL-SH-TH Data Logging Trend\u003c\/b\u003e\u003cbr\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/OM-HL-SH_DIA2.jpg?v=1741315844\" width=\"500\" height=\"250\"\u003e\u003cbr\u003e \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817397231911,"sku":"OM-HL-SH-Series","price":189.4,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817397264679,"sku":"OM-HL-SH-Series","price":189.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-hl-sh_l_hyumwndwkf1pyw3p.jpg?v=1741315861"},{"product_id":"multi-use-pdf-temperature-and-humidity-data-loggers","title":"Multi-Use PDF Temperature and Humidity Data Loggers","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e\n\u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-22, OM-23 and OM-24 are multiple use temperature and humidity data loggers that are ideal for a wide range of test and measurement, quality control, and environmental monitoring applications. They conveniently generate a PDF and Excel report on completion of data logging. The OM-22 measures ambient temperature using an internal thermistor temperature sensor. The OM-23 measures ambient temperature and also accepts an external thermistor temperature probe as input. Model OM-24 measures ambient temperature and relative humidity. These data loggers are completely user-programmable including language selection, sampling interval, start delay, alarm delay, temperature units, alarm range, alarm type, password and user name. No special software or driver is required for setup or download of data. The data logger appears as a mass storage device when connected to the PC. The user manual, a calibration certificate and data logger configuration utility are all stored in the data logger.\u003cbr\u003e\u003cbr\u003e To setup the data logger simply plug it into a USB port on your computer and run the on-board configuration utility. Once configuration is complete the data logger can be removed from the PC’s USB port. On completion of data logging re-connect the data logger to the computer and open the configuration utility. Choose the function convert to PDF or convert to Excel and select the desired location on your computer to store the reports. The PDF report contains the data summary, graph and tabular results. The Excel report contains all of the information in the PDF report except for the graph. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817397428519,"sku":"OM-22-Series","price":241.84,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817397461287,"sku":"OM-22-Series","price":241.84,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-22-23-24_l_utot0xdcbkxpme5a.jpg?v=1741315883"},{"product_id":"compact-portable-usb-temperature-and-humidity-data-loggers","title":"Compact Portable USB Temperature and Humidity Data Loggers","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\"\u003e \u003c!-- \u003cb\u003e\u003cspan style=\"color: blue;\" _mce_style=\"color: blue;\"\u003e Please check out Newest Released Temperature and Humidity Portable Data Loggers with LCD Display\u003ca href=\"https:\/\/www.omega.com\/en-us\/control-and-monitoring-devices\/data-loggers\/p\/OM-HL-SH-Series\" _mce_href=\"https:\/\/www.omega.com\/en-us\/control-and-monitoring-devices\/data-loggers\/p\/OM-HL-SH-Series\" class=\"blLink\"\u003e OM-HL-SH Series \u003c\/a\u003e or \u003ca href=\"https:\/\/www.omega.com\/pptst\/OM-HL-SP.html\" _mce_href=\"https:\/\/www.omega.com\/pptst\/OM-HL-SP.html\" class=\"blLink\"\u003e OM-HL-SP Series \u003c\/a\u003efor more advanced features with better price.\u003c\/span\u003e\u003c\/b\u003e\u003cbr \/\u003e\u003cbr \/\u003e --\u003e The OM-90 Series are portable, battery operated, temperature (OM-91) and temperature\/humidity (OM-92) data loggers. The OM-90 Series data loggers offer accurate and repeatable logging for temperature and relative humidity. Temperature is measured to an accuracy of ±0.3°C over the range of 5 to 60°C (41 to 140°F) and ±2.0°C over the full range of -30 to 80°C (-22 to 176°F). Relative humidity is measured to an accuracy of ±3.0% RH over the 20 to 80% RH range and ±5.0% RH over the 0 to 100% RH range. Both temperature and relative humidity are logged at a user configurable logging rate which is software selectable.\u003cbr\u003e\u003cbr\u003e These data loggers are ideal for transportation applications where it is necessary to document that the material in-transit has stayed within particular environmental limits. High\/low alarm limits can be set above or below which LED indicators will be activated so that the user can become aware that the desired transportation conditions have been exceeded.\u003cbr\u003e\u003cbr\u003e Each data logger can be assigned a 16 character name. This can be helpful in applications where multiple data loggers are used and there is a need to distinguish between them (for example based on location).\u003cbr\u003e\u003cbr\u003eThe data logger includes a very easy to use software application. The application is used for configuration of the logger, extraction of logger data, graphically viewing data, spread sheet analysis of data and saving data to file (typically in comma separated value CSV file format) for third party applications such as Microsoft Excel. The graphical user interface is completely intuitive in terms of configuring new devices and extracting data from a field device. When the user has multiple devices requiring the same setup then a logger setup from a saved configuration file can be preloaded into the application to help expedite the process and ensure all loggers get setup identically. The application does not require any driver installations to connect to the data logger. Just install the software, run it and then connect the data logger.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eRange:\u003c\/b\u003e -30 to 80°C (-22 to 176°F)\u003cbr\u003e     \u003cb\u003eResolution:\u003c\/b\u003e 0.01°C\u003cbr\u003e     \u003cb\u003eAccuracy:\u003c\/b\u003e ±0.3°C from 5 to 60°C (41 to 140°F)\u003cbr\u003e     \u003cb\u003eCalibration Accuracy @ 25°C ±20°C:\u003c\/b\u003e ±0.1°C\u003cbr\u003e \u003cb\u003eHumidity (OM-92 Only)\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eRange:\u003c\/b\u003e 0 to 95% RH\u003cbr\u003e     \u003cb\u003eResolution:\u003c\/b\u003e 0.01% RH\u003cbr\u003e     \u003cb\u003eAccuracy:\u003c\/b\u003e ±3% over 20 to 80% RH range; ±5% RH below 20% RH or above 80% RH\u003cbr\u003e     \u003cb\u003eCalibration Accuracy @ 25% RH:\u003c\/b\u003e ±1.8% RH @ 25% RH\u003cbr\u003e \u003cb\u003eMemory\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-91:\u003c\/b\u003e 65,520 temperature measurements\u003cbr\u003e     \u003cb\u003eOM-92:\u003c\/b\u003e 65,520 temperature and 65,520 humidity measurements\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e Immediate start on disconnect from PC, delayed start (scheduled date\/time) or pushbutton start\u003cbr\u003e \u003cb\u003eRecording Mode:\u003c\/b\u003e Stop on memory full; when data logger operation is start\/stopped by user intervention via button press, last memory location is retained\u003cbr\u003e \u003cb\u003eRecording Interval:\u003c\/b\u003e 1 sec, 10 sec, 30 sec, 1 min, 10 min, 30 min, 1 hr (software selectable)\u003cbr\u003e \u003cb\u003eSoftware Compatibility:\u003c\/b\u003e Windows XP\/Vista\/7, 8 \u0026amp; 10 (32-bit and 64-bit)\u003cbr\u003e \u003cb\u003eReal Time Logging:\u003c\/b\u003e Displays real time data when connected to a PC\u003cbr\u003e \u003cb\u003eReal Time Clock:\u003c\/b\u003e Time automatically synced to PC\u003cbr\u003e \u003cb\u003eBattery Backup:\u003c\/b\u003e Continues to keep time when off\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e 0.50 sec\/day (~3 min\/year)\u003cbr\u003e \u003cb\u003eAlarms:\u003c\/b\u003e High and Low alarms for temperature and humidity; dedicated alarm LED indicator\u003cbr\u003e \u003cb\u003eLED Indicators:\u003c\/b\u003e Alarm and status LEDs\u003cbr\u003e \u003cb\u003eDevice ID:\u003c\/b\u003e Each data logger can have a 16 character name assigned\u003cbr\u003e \u003cb\u003eConnections:\u003c\/b\u003e 0.9 m (3') USB Micro-B to PC cable (included)\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 3V lithium CR2450 battery included (user replaceable)\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e Over 4 year battery life while logging\u003cbr\u003e \u003cb\u003eBypass Mode:\u003c\/b\u003e Unit is powered from USB when connected to conserve the battery\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 53 H x 33 W x 15 mm D (1.38 x 2.36 x 0.6')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 25 g (0.9 oz) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817397657895,"sku":"OM-90-Series","price":279.83,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817397690663,"sku":"OM-90-Series","price":279.83,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-90_series_l_bkhmclruu7cd9oz9.jpg?v=1741315910"},{"product_id":"2-channel-handheld-7-thermocouple-types-datalogger-usb-output","title":"2 Channel Handheld  7 Thermocouple Types Datalogger USB output","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The HH147AU is a 2-channel thermometer with data logging capabilities and a capacity of 14,000 records. It offers an wide array of value added features including: accepting 7 different thermocouple types, large backlit LCD with 5-digits, dual displays (T1, T2 or T1-T2) with the maximum reading of 9999.9, relative (REL) measurement, selectable °C\/°F\/K units, stores 300 readings manually, max\/min\/avg\/time and data hold functions, auto power-off with disable function, and hi\/lo audible alarm functions. A USB PC serial interface and cable are also included for connectivity to a PC.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cem\u003eAccuracy is specified for ambient temperatures between 18 to 28°C (64 to 82°F).\u003c\/em\u003e\u003cbr\u003e \u003cb\u003eThermocouple Ranges:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eK Type:\u003c\/b\u003e -200 to 1372°C (-328 to 2501°F)\u003cbr\u003e     \u003cb\u003eJ Type:\u003c\/b\u003e -210 to 1200°C (-346 to 2192°F)\u003cbr\u003e     \u003cb\u003eT Type:\u003c\/b\u003e -250 to 400°C (-418 to 752°F)\u003cbr\u003e     \u003cb\u003eE Type:\u003c\/b\u003e -210 to 1000°C (-346 to 1832°F)\u003cbr\u003e     \u003cb\u003eR\/S Type:\u003c\/b\u003e 0 to 1767°C (32 to 3212°F)\u003cbr\u003e     \u003cb\u003eN Type:\u003c\/b\u003e -150 to 1300°C (-238 to 2372°F)\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eK \/ J \/ T \/ E \/ N Type:\u003c\/b\u003e 0.1°\u003cbr\u003e     \u003cb\u003eR\/S Type:\u003c\/b\u003e 1°\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eK \/ J \/ T \/ E \/ N Type:\u003c\/b\u003e ±(0.05% rdg, 0.7°C\/1.4°F) -250 to -100°C (-418 to -148°F) ±(0.05% rdg, 0.6°C\/1°F) -100 to 1372°C (-148 to 2501°F)\u003cbr\u003e     \u003cb\u003eR\/S Type:\u003c\/b\u003e ±(0.05% rdg, 2°C\/4°F) 0 to 1767°C (32 to 3212°F)\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e 0.01% 0.03°C of read value\/°C (0.06°F\/°F) outside 18 to 28°C (64 to 82°F) specified range [Under -100°C (-148°F): 0.04% of read value added to K, J, T, E, and 0.08% read value added to N]\u003cbr\u003e \u003cb\u003eTemperature Scale:\u003c\/b\u003e ITS-90\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e Approximately 100 hours\u003cbr\u003e \u003cb\u003eOperation and Storage Temperature and Humidity:\u003c\/b\u003e 0 to 50°C (32 to 122°F), \u0026lt; 80% RH\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 155 L x 56 W x 40 D mm (6.10 x 2.20 x 1.57')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e Approximately 170 g (0.37 lb)\u003cbr\u003e \u003cb\u003eUSB PC Serial Interface:\u003c\/b\u003e Windows\u003csup\u003e®\u003c\/sup\u003e XP\/7\/8\/10\u003cbr\u003e \u003cb\u003e\u003cem\u003e*\u003c\/em\u003e\u003c\/b\u003e\u003cem\u003e The above specifications do not include error of thermocouple\u003c\/em\u003e \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817398182183,"sku":"HH147AU-Series","price":916.17,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817398214951,"sku":"HH147AU-Series","price":916.17,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/hh147au_l_8dfslz7cgl4vzlpn.jpg?v=1741315931"},{"product_id":"portable-usb-temperature-and-humidity-data-loggers-with-display","title":"Portable USB Temperature and Humidity Data Loggers with Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\"\u003e \u003c!--\u003cb\u003e\u003cspan style=\"color: blue;\" _mce_style=\"color: blue;\"\u003e Please check out Newest Released Temperature and Humidity Portable Data Logger with LCD Display\u003ca href=\"https:\/\/www.omega.com\/en-us\/control-and-monitoring-devices\/data-loggers\/p\/OM-HL-SH-Series\" _mce_href=\"https:\/\/www.omega.com\/en-us\/control-and-monitoring-devices\/data-loggers\/p\/OM-HL-SH-Series\" class=\"blLink\"\u003e OM-HL-SH Series \u003c\/a\u003e for more advanced features with excellent user experience.\u003c\/span\u003e\u003c\/b\u003e\u003cbr \/\u003e\u003cbr \/\u003e --\u003e The OM-70 Series of portable temperature and temperature\/humidity data loggers are easy-to use, versatile devices which can be used for a wide range of logging applications including coolers, freezers, greenhouses, museums, laboratories, shipping containers, warehouses, environmental monitoring and food storage. \u003cbr\u003e\u003cbr\u003e These data loggers are capable of sampling as fast as once per second or as slow as every 18 hours. Models OM-71 and OM-72 can store a total of 43,344 temperature measurements in memory. Model OM-73 can store a total of 43,344 measurement points for temperature only or 21,672 points of temperature, humidity and dew point. The model OM-74 thermocouple data logger can store 32,638 temperature samples. Easy-to-use Windows software is included with each data logger. \u003cbr\u003e\u003cbr\u003e The software is a full-featured program that allows you to set up all data logger functions including sampling rate, logging duration, start mode, logging mode, and high and low temperature alarm values. Once data has been logged, the program then allows you to download data from the logger, plot the data and export the data to an ASCII text or Excel file format for further analysis. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSoftware Features Include:\u003c\/b\u003e\u003cbr\u003e • Data summary to read statistics and alarm information in a simplified report format.\u003cbr\u003e • Data listing for tabular view of detailed dates, times and values of recorded data.\u003cbr\u003e • Graph function displays data in clear graphical format.\u003cbr\u003e • Zoom magnifies data with powerful zoom and autoscale functions.\u003cbr\u003e • Autoscale function fits data to the screen or allows user to manually enter their own values.\u003cbr\u003e • Graphical Cursor displays exact data of any point in the graphical display.\u003cbr\u003e • Export data in text or Excel format.\u003cbr\u003e • Print graph or text data with print preview and setup options.\u003cbr\u003e • Logger configuration allows easy set up and launch of data loggers with immediate or delayed start, preferred sample rate, alarm setup, and custom ID.\u003cbr\u003e • Password protected calibration function automatically stores with parameters in device or restores factory defaults. A calibration Window is provided in the software to simplify the calibration procedure.\u003cbr\u003e • Status windows display unique ID of logger, battery voltage, memory used, sample rate, duration, alarm condition and logging status.\u003cbr\u003e • Menu Bar along the top of the screen provides one click access to software functions. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e OM-71, OM-72, OM-73\u003cbr\u003e Ambient Temperature Measurement Range \u003cbr\u003e (Models OM-71, OM-73):\u003c\/b\u003e -20 to 70°C (-4 to 160°F)\u003cbr\u003e \u003cb\u003eExternal Sensor Temperature Measurement Range\u003cbr\u003e (Model OM-72): \u003c\/b\u003e-40 to 70°C (-40 to 160°F)\u003cbr\u003e \u003cb\u003eStorage Temperature: \u003c\/b\u003e-40 to 77°C (-40 to 170°F)\u003cbr\u003e \u003cb\u003eTemperature Accuracy: \u003c\/b\u003e±0.5°C (±1°F), from -17 to 50°C (1 to 122°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution: \u003c\/b\u003e0.1°C (0.05°F)\u003cbr\u003e \u003cb\u003eRelative Humidity Range \u003cbr\u003e(Model OM-73):\u003c\/b\u003e 0 to 99% RH non-condensing\u003cbr\u003e \u003cb\u003eRelative Humidity Accuracy \u003cbr\u003e(Model OM-73):\u003c\/b\u003e ±2% RH from 10 to 90% RH @ 25°C (77°F)\u003cbr\u003e \u003cb\u003eRelative Humidity Resolution\u003cbr\u003e (Model OM-73):\u003c\/b\u003e 0.05% RH\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOM-74\u003cbr\u003e Display Temperature Resolution:\u003c\/b\u003e 0.1°C (0.2°F) up to 199.9 °C or °F,\u003cbr\u003e 1°C (1°F) above 200 °C or °F\u003cbr\u003e \u003cb\u003eLogged Temperature Resolution: \u003c\/b\u003e0.1°C (0.2°F)\u003cbr\u003e \u003cb\u003eThermocouple Impedance:\u003c\/b\u003e 50 ? max for specified accuracy\u003cbr\u003e \u003cb\u003eCold Junction Temperature Accuracy:\u003c\/b\u003e ± 0.3°C (±0.5°F)\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -18 to 55°C (0 to 131°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e-30 to 80°C (-20 to 175°F)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003cbr\u003e Sample Rate: \u003c\/b\u003e1 second to 18 hours user selectable\u003cbr\u003e \u003cb\u003eAlarm Settings: \u003c\/b\u003eOver\/under alarm with visual indication\u003cbr\u003e \u003cb\u003eLCD Display: \u003c\/b\u003eDisplays temperature, date, time, \u003cbr\u003ealarm condition recording status and battery condition\u003cbr\u003e \u003cb\u003eTime Accuracy: \u003c\/b\u003e±100 ppm @ 24°C (75°F)\u003cbr\u003e \u003cb\u003eMeasurement Capacity: OM-71, OM-72, OM-73: \u003c\/b\u003e \u003cbr\u003e Non-volatile memory; 43,344 samples\u003cbr\u003efor temperature only, or 21,672 samples for temperature,\u003cbr\u003e humidity and dew point (Model OM-73); \u003cb\u003eOM-74;\u003c\/b\u003e 32,638 temperature samples\u003cbr\u003e \u003cb\u003eRecording Control: \u003c\/b\u003eStart on button press, immediate after setup, \u003cbr\u003eor at a user specified date and time\u003cbr\u003e \u003cb\u003eRecording Mode: \u003c\/b\u003eStop on memory full, \u003cbr\u003eor continuous recording with memory rollover\u003cbr\u003e \u003cb\u003eMinimum System Requirements: \u003c\/b\u003e8MB of RAM, 2MB of disk space, \u003cbr\u003e800 x 600 resolution, 1 free USB port\u003cbr\u003e \u003cb\u003eSoftware Compatibility: \u003c\/b\u003eWindows XP\/Vista\/7 and 8 (32-bit and 64-bit)\u003cbr\u003e \u003cb\u003eInterface: \u003c\/b\u003eUSB 2.0\u003cbr\u003e \u003cb\u003ePower: OM-71, OM-72, OM-73:\u003c\/b\u003e 3 V CR2032 lithium battery (included);\u003cbr\u003e \u003cb\u003eOM-74;\u003c\/b\u003e 3 AAA batteries (alkaline or lithium)\u003cbr\u003e \u003cb\u003eBattery Life: \u003c\/b\u003e3 years (average)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eOM-71, OM-72, OM-73:\u003c\/b\u003e 6 H x 5.7 W x 1.3 cm D (2.36 x 2.24 x 0.51')\u003cbr\u003e \u003cb\u003eOM-74:\u003c\/b\u003e 5.7 H x 5.5 W x 3.0 cm D (2.25 x 2.15 x 1.2')\u003cbr\u003e \u003cb\u003eWeight: \u003cbr\u003e OM-71, OM-72, OM-73:\u003c\/b\u003e 91 g (3.2 oz)\u003cbr\u003e \u003cb\u003eOM-74:\u003c\/b\u003e 62 g (2.2 oz) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817398477095,"sku":"OM-70-Series","price":511.3,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817398509863,"sku":"OM-70-Series","price":511.3,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-70_series_l_rbrngahbffx7gbhx.jpg?v=1741315954"},{"product_id":"5-pack-temperature-data-logger-with-usb-interface","title":"5 Pack Temperature Data Logger with USB Interface","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-EL-USB-LITE is a low-cost temperature data logger that measures and stores up to 4080 temperature readings over a -10 to 50°C (14 to 122°F) measurement range. It has a fixed 30-minute sample rate and a battery life of 1 month with continuous use. Press the button and a red\/green LED indicates whether a preset alarm level has been breached. The data logger is configured and the stored data is downloaded by plugging the module into a PC's USB port and running the control software under Windows XP SP3\/Vista\/7 and 8. The downloaded data can be graphed, printed, and exported to other applications. A battery comes installed. To start logging, pull out the tab. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eBattery Replacement\u003c\/b\u003e\u003cbr\u003e The user should replace the battery every month, or before logging critical data. The OM-EL-USB-LITE does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and cannot restart until the battery has been replaced and the logged data has been downloaded to a PC. \u003cbr\u003e\u003cbr\u003e For maximum logging life, use only OM-EL-BATT-LITE replacement batteries. Before replacing the battery, remove the OM-EL-USB-LITE from the PC. \u003cbr\u003e\u003cbr\u003e \u003cb\u003e Note:\u003c\/b\u003e Leaving the OM-EL-USBLITE plugged into the USB port for longer than required will shorten battery life. \u003cbr\u003e\u003cbr\u003e \u003cb\u003e LED Flashing Modes\u003c\/b\u003e\u003cbr\u003e The OM-EL-USB-LITE has a bicolor LED status light. To save power, it operates for only a short time after the pushbutton is released. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range: \u003c\/b\u003e-10 to 50°C (14 to 122°F)\u003cbr\u003e \u003cb\u003eInternal Resolution: \u003c\/b\u003e1°C (2°F)\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e ±2.5°C (±4.5°F)\u003cbr\u003e \u003cb\u003eMemory: \u003c\/b\u003e4080 readings \u003cbr\u003e \u003cb\u003eLogging Interval:\u003c\/b\u003e 30 minute (fixed)\u003cbr\u003e \u003cb\u003eOperating Temperature Range: \u003c\/b\u003e-10 to 50°C (14 to 122°F)\u003cbr\u003e \u003cb\u003eAlarm Thresholds: \u003c\/b\u003e2 (user programmable)\u003cbr\u003e \u003cb\u003eStart Date\/Time: \u003c\/b\u003eSelectable in software\u003cbr\u003e \u003cb\u003eStatus Indicators (LEDs): \u003c\/b\u003eRed\/green alarm status indication via pushbutton\u003cbr\u003e \u003cb\u003eSoftware: \u003c\/b\u003eWindows XP SP3\/Vista\/7 and 8 (32- and 64-bit)\u003cbr\u003e \u003cb\u003ePower: \u003c\/b\u003e3 V coin cell battery (included)\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 1 month\u003cbr\u003e \u003cb\u003eWeight: \u003c\/b\u003e30 g (1 oz)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e\u003cbr\u003e 68 x 18 x 9.4 mm (2.7 x 0.7 x 0.4' ) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817398673703,"sku":"OM-EL-USB-LITE-5-Loggers","price":535.1,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817398706471,"sku":"OM-EL-USB-LITE-5-Loggers","price":535.1,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-el-usb-lite-5_l_m4wwjd4btj1ztyl3.jpg?v=1741315977"},{"product_id":"portable-data-loggers-with-usb-interface","title":"Portable Data loggers with USB Interface","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\u003cspan class=\"descCopyPP\"\u003e The OM-EL-USB Series of data loggers includes models for temperature, temperature\/relative humidity, voltage, and current measurement. The user can easily set up the data logger and download the stored data by plugging the module into a PC\"s USB port and running the easy-to-use Windows software. Software-selectable setup parameters include logging rate, start-time, high\/low alarm settings, and temperature units (°C or °F). Data can then be graphed, printed, and exported to other applications such as Excel. Each data logger is supplied complete with a long-life lithium battery. Built-in LED indicators show data logger status. OM-EL-USB Series data loggers are protected against moisture to IP67 standards when the protective cap is fitted.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e \u003cdiv class=\"tableWrapPP\"\u003e\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\" width=\"750\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cu\u003e\u003cb\u003e\u003cfont size=\"4\"\u003eOM-EL-USB-1\u003c\/font\u003e\u003c\/b\u003e\u003c\/u\u003e\u003cbr\u003e \u003cb\u003eTEMPERATURE DATA LOGGER\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange\u003c\/b\u003e: -35 to 80°C (-31 to 176°F)\u003cbr\u003e \u003cb\u003eResolution\u003c\/b\u003e: 0.5°C (1°F)\u003cbr\u003e \u003cb\u003eAccuracy\u003c\/b\u003e: ±1.0°C (±2.0°F)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMemory\u003c\/b\u003e: 16,000 temperature readings\u003cbr\u003e \u003cb\u003eLogging Interval\u003c\/b\u003e: 10 sec. to 12 h.\u003cbr\u003e \u003cb\u003eOperating Temperature Range\u003c\/b\u003e: -35 to 80°C (-31 to 176°F)\u003cbr\u003e \u003cb\u003eAlarm Thresholds\u003c\/b\u003e: High\/low alarm thresholds selectable in software\u003cbr\u003e \u003cb\u003eStart Date\/Time\u003c\/b\u003e: Selectable in software\u003cbr\u003e \u003cb\u003eStatus Indicators (LEDs)\u003c\/b\u003e: Red, green and orange\u003cbr\u003e \u003cb\u003eSoftware\u003c\/b\u003e: Windows 2000\/XP\/Vista\/7 (32- and 64-bit)\u003cbr\u003e \u003cb\u003ePower\u003c\/b\u003e: ½ AA 3.6 V lithium battery (included)\u003cbr\u003e \u003cb\u003eBattery Life\u003c\/b\u003e: 1 year (at 25°C and 1 minute logging interval)\u003cbr\u003e \u003cb\u003eWeight\u003c\/b\u003e: 43 g (1.5 oz)\u003cbr\u003e \u003cb\u003eDimensions\u003c\/b\u003e: See dimensional drawing\u003cbr\u003e\u003cbr\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/OM-EL-USB-1_Dimensions.gif?v=1741315989\" border=\"0\" alt=\"H: 94mm, W: 27mm\"\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e \u003ctd valign=\"top\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/OM-EL-USB-1_1.jpg?v=1741315993\" border=\"0\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e\u003cu\u003e\u003cfont size=\"4\"\u003eOM-EL-USB-2 AND OM-EL-USB-2-PLUS\u003c\/font\u003e\u003c\/u\u003e\u003cbr\u003e TEMPERATURE AND RELATIVE HUMIDITY DATA LOGGER\u003cbr\u003e (DEW POINT INDICATION VIA WINDOWS SOFTWARE)\u003cbr\u003e TEMPERATURE\u003cbr\u003e Range\u003c\/b\u003e: -35 to 80°C (-31 to 176°F)\u003cbr\u003e \u003cb\u003eResolution\u003c\/b\u003e: 0.5°C(1°F)\u003cbr\u003e \u003cb\u003eAccuracy: OM-EL-USB-2:\u003c\/b\u003e ±0.5°C (±1.0°F); \u003cbr\u003e\u003cb\u003eOM-EL-USB-2-PLUS:\u003c\/b\u003e ±0.3°C (±0.6°F)\u003cbr\u003e \u003cb\u003eHUMIDITY\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange\u003c\/b\u003e: 0 to 100% RH\u003cbr\u003e \u003cb\u003eResolution\u003c\/b\u003e: 0.5% RH\u003cbr\u003e \u003cb\u003eAccuracy\u003c\/b\u003e 20 to 80% RH; \u003cbr\u003e\u003cb\u003eOM-EL-USB-2: \u003c\/b\u003e±3.5% RH\u003cbr\u003e \u003cb\u003eOM-EL-USB-2-PLUS:\u003c\/b\u003e ±2.0% RH \u003cbr\u003e \u003cb\u003eDEW POINT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eAccuracy\u003c\/b\u003e (overall error in the calculated dew point for RH measurements from 40 to 100% RH @ 25°C): ±2°C (±4°F)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMemory\u003c\/b\u003e: 16,000 temperature and 16,000 relative humidity readings\u003cbr\u003e \u003cb\u003eLogging Interval\u003c\/b\u003e: 10 seconds to 12 hours\u003cbr\u003e \u003cb\u003eOperating Temperature Range\u003c\/b\u003e: -35 to 80°C (-31 to 176°F)\u003cbr\u003e \u003cb\u003eAlarm Thresholds\u003c\/b\u003e: High\/low alarm thresholds for % RH and temperature, selectable in software\u003cbr\u003e \u003cb\u003eStart Date\/Time\u003c\/b\u003e: Selectable in software\u003cbr\u003e \u003cb\u003eStatus Indicators (LEDs)\u003c\/b\u003e: Red and green\u003cbr\u003e \u003cb\u003eSoftware\u003c\/b\u003e: Windows 2000\/XP\/Vista\/7 (32- and 64-bit)\u003cbr\u003e \u003cb\u003ePower\u003c\/b\u003e: ½ AA 3.6 V lithium battery (included)\u003cbr\u003e \u003cb\u003eBattery Life\u003c\/b\u003e: 1 year typical (depends on sample rate, ambient temperaure and use of alarm LEDs)\u003cbr\u003e \u003cb\u003eWeight\u003c\/b\u003e: 57 g (2 oz)\u003cbr\u003e \u003cb\u003eDimensions\u003c\/b\u003e: See dimensional drawing\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e \u003ctd valign=\"top\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/OM-EL-USB-1_2.jpg?v=1741315997\" border=\"0\" alt=\"H: 103mm, W: 26.4mm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cu\u003e\u003cb\u003e\u003cfont size=\"4\"\u003eOM-EL-USB-3\u003c\/font\u003e\u003c\/b\u003e\u003c\/u\u003e\u003cbr\u003e \u003cb\u003eVOLTAGE DATA LOGGER\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange\u003c\/b\u003e: 0 to 30 Vdc\u003cbr\u003e \u003cb\u003eResolution\u003c\/b\u003e: 100 mV\u003cbr\u003e \u003cb\u003eAccuracy\u003c\/b\u003e: ±1%\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMemory\u003c\/b\u003e: 32,000 voltage readings\u003cbr\u003e \u003cb\u003eLogging Interval\u003c\/b\u003e: 1 seconds to 12 hours\u003cbr\u003e \u003cb\u003eOperating Temperature Range\u003c\/b\u003e: -25 to 80°C (-13 to 176°F)\u003cbr\u003e \u003cb\u003eAlarm Thresholds\u003c\/b\u003e: High\/low alarm thresholds selectable in software\u003cbr\u003e \u003cb\u003eStart Date\/Time\u003c\/b\u003e: Selectable in software\u003cbr\u003e \u003cb\u003eStatus Indicators (LEDs)\u003c\/b\u003e: Red and green\u003cbr\u003e \u003cb\u003ePower\u003c\/b\u003e: ½ AA 3.6 V lithium battery (included)\u003cbr\u003e \u003cb\u003eBattery Life\u003c\/b\u003e: 1 year typical (depends on sample rate, ambient temperature and use of alarm LEDs)\u003cbr\u003e \u003cb\u003eWeight\u003c\/b\u003e: 57 g (2 oz)\u003cbr\u003e \u003cb\u003eDimensions\u003c\/b\u003e: See dimensional drawing\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e \u003ctd valign=\"top\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/OM-EL-USB-1_3.jpg?v=1741316006\" border=\"0\" alt=\"H: 112mm, W: 26.4mm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cu\u003e\u003cb\u003e\u003cfont size=\"4\"\u003eOM-EL-USB-4\u003c\/font\u003e\u003c\/b\u003e\u003c\/u\u003e\u003cbr\u003e \u003cb\u003eCURRENT DATA LOGGER\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange\u003c\/b\u003e: 4 to 20 mA\u003cbr\u003e \u003cb\u003eResolution\u003c\/b\u003e: 0.1 mA\u003cbr\u003e \u003cb\u003eAccuracy\u003c\/b\u003e: ±1%\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMemory\u003c\/b\u003e: 32,000 current readings\u003cbr\u003e \u003cb\u003eLogging Interval\u003c\/b\u003e: 1 seconds to 12 hours\u003cbr\u003e \u003cb\u003eOperating Temperature Range\u003c\/b\u003e: -35 to 80°C (-31 to 176°F)\u003cbr\u003e \u003cb\u003eAlarm Thresholds\u003c\/b\u003e: High\/low alarm thresholds selectable in software\u003cbr\u003e \u003cb\u003eStart Date\/Time\u003c\/b\u003e: Selectable in software\u003cbr\u003e \u003cb\u003eStatus Indicators (LEDs)\u003c\/b\u003e: Red and green\u003cbr\u003e \u003cb\u003ePower\u003c\/b\u003e: ½ AA 3.6 V lithium battery (included)\u003cbr\u003e \u003cb\u003eBattery Life\u003c\/b\u003e: 1 year typical (depends on sample rate, ambient temperature and use of alarm LEDs)\u003cbr\u003e \u003cb\u003eWeight\u003c\/b\u003e: 57 g (2 oz)\u003cbr\u003e \u003cb\u003eDimensions\u003c\/b\u003e: See dimensional drawing\u003cbr\u003e\n\u003c\/td\u003e \u003ctd valign=\"top\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/OM-EL-USB-1_4.jpg?v=1741316010\" border=\"0\" alt=\"H: 112mm, W: 26.9mm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817399329063,"sku":"OM-EL-USB-1-Series","price":247.76,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817399361831,"sku":"OM-EL-USB-1-Series","price":247.76,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-el-usb-1_l_wunltkf28q4kon5u.jpg?v=1741316029"},{"product_id":"21cfr-compliant-usb-data-loggers-for-vaccine-and-cold-chain","title":"21CFR Compliant USB Data Loggers for Vaccine \u0026 Cold Chain","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"tab-container\"\u003e\n\t\t\t\t\t\u003cdiv class=\"tab-details\"\u003e\n\t\u003cp\u003eThe OM-EL-21CFR-Series loggers are ideal for applications that require secure storage of data for critical applications such as vaccine monitoring, food and beverage, and cold chain monitoring. These standalone dataloggers are capable of storing between 16,000 to 32,000 temperature or humidity readings depending on the models outlined below.\u003c\/p\u003e\n\u003cp class=\"half-col video-right\"\u003e \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/0y4I2MH6wQk\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e \u003c\/p\u003e\n\u003cp\u003eThe OM-EL-21CFR-Series offers models with internal temperature sensors as well as external probe attachments which allow for a wider temperature sensing range.\u003c\/p\u003e\n\u003cp\u003eThe OM-EL-21CFR-VAC is specifically designed for vaccine monitoring as it is included with a glycol buffer solution and termistor probe calibrated at 2°C and  8°C which are typical storage requirements for many vaccines.\n\u003c\/p\u003e\n\u003cp\u003eThe user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the free Omega 21CFR software. Data can then be graphed, printed and exported to other applications for detailed analysis. The encrypted data has full audit tracking to comply with the requirements of 21CFR Part 11.\u003c\/p\u003e\n\u003cp\u003eThe high contrast LCD can show a variety of temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored values for temperature.\u003c\/p\u003e\n\u003cp\u003eThe data logger is supplied with a lithium metal battery which typically gives 2 years’ logging life.\u003c\/p\u003e\n\u003cp\u003eOmega offers models that are pre-calibrated (-NIST) with calibration points outlined below. If you require custom calibration points, please give us a call and we can help you with a custom calibration solution.\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\" border=\"2\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 12%;\"\u003e \u003c\/td\u003e\n\u003cth style=\"width: 12%;\"\u003eOM-EL-21CFR-TC-LCD\u003c\/th\u003e\n\u003cth style=\"width: 12%;\"\u003eOM-EL-21CFR-1-LCD\u003c\/th\u003e\n\u003cth style=\"width: 12%;\"\u003eOM-EL-21CFR-2-LCD\u003c\/th\u003e\n\u003cth style=\"width: 12%;\"\u003eOM-EL-21CFR-TC\u003c\/th\u003e\n\u003cth style=\"width: 12%;\"\u003eOM-EL-21CFR-TP-LCD\u003c\/th\u003e\n\u003cth style=\"width: 13%;\"\u003eOM-EL-21CFR-TP-LCD-PLUS\u003c\/th\u003e\n\u003cth style=\"width: 13%;\"\u003eOM-EL-21CFR-VAC\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eMeasurement Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eTemperature, Humidity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003eTemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eProbe\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eThermocouple Probe\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eInternal\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eInternal\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eThermocouple Probe\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eThermistor Probe\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eThermistor Probe\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003eThermistor Probe Kit w\/ Glycol bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\" rowspan=\"2\"\u003e\n\u003cp\u003e \u003c\/p\u003eMeasurement Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e-100 to 200°C \u003cbr\u003e(-148 to 392°F) T-type (supplied)²\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e-35 to +80°C (-31 to +176°F)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e-35°C to 80°C (-31°F to 176°F)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e0 to 200°C (32 to 392°F) K type (supplied)³\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e-40 to +125°C (-40 to +257°F)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e-40 to +125°C (-40 to +257°F)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\" rowspan=\"2\"\u003e-40 to +125°C (-40 to +257°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003e0 to 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eReadings\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e32,510\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e16,379\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e16,382 temperature, 16,382 RH\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e32,510\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e32,510\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003e32,510\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003e32,510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eLogging Rate (User Selectable)\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e10 seconds to 12 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e10 seconds to 12 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e10 seconds to 12 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e1 second to 12 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e1 second to 12 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e1 second to 12 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e1 second to 12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\" rowspan=\"2\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e± 2.5°C typical\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e± 0.5°C typical (see graph in datasheet)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e±0.55°C (1.04°F) typical (5 to 60°C)**\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e± 2.5°C typical\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e±1°C (-40 to 100°C)**\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" rowspan=\"2\" align=\"center\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e±0.5°C (-40 to 100°C)**\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\" rowspan=\"2\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e±0.5C (-40 to 100°C)**\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003e±2.25 %RH typical (20 to 80%RH)**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eLCD Display\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eNIST Calibration Option Available?\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes*\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes*\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes*\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes*\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes*\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes*\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003eIncluded at +2C and +8C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eNIST Option Calibration Points\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e-80C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e5C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e25C at 50% RH\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e5C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e5C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e5C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eIP67 Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px;\"\u003eDatasheet Link\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/assets.omega.com\/spec\/OM-EL-21CFR-TC-LCD_Spec.pdf\"\u003eOM-EL-21CFR-TC-LCD\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e\u003ca href=\"https:\/\/assets.omega.com\/spec\/OM-EL-21CFR-1-LCD_spec.pdf\"\u003eOM-EL-21CFR-1-LCD\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e\u003ca href=\"https:\/\/assets.omega.com\/spec\/OM-EL-21CFR-2-LCD_spec.pdf\"\u003eOM-EL-21CFR-2-LCD\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e\u003ca href=\"https:\/\/assets.omega.com\/spec\/OM-EL-21CFR-TC_spec.pdf\"\u003eOM-EL-21CFR-TC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e\u003ca href=\"https:\/\/assets.omega.com\/spec\/OM-EL-21CFR-TP-LCD_spec.pdf\"\u003eOM-EL-21CFR-TP-LCD\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" align=\"center\"\u003e\u003ca href=\"https:\/\/assets.omega.com\/spec\/OM-EL-21CFR-TP-LCD-PLUS_spec.pdf\"\u003eOM-EL-21CFR-TP-LCD-PLUS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: center;\"\u003e\u003ca href=\"https:\/\/assets.omega.com\/spec\/OM-EL-21CFR-VAC_spec.pdf\"\u003eOM-EL-21CFR-VAC\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n*Must order -NIST Option. For example OM-EL-21CFR-1-LCD-NIST would include a NIST certificate calibrated at 5°C. Contact us if custom calibration points are required.\u003cbr\u003e **The overall error takes into account the sensor accuracy and the resolution of the logger. Please refer to datasheet.\u003cbr\u003e \u003csup\u003e2\u003c\/sup\u003e Also accepts any standard T-type thermocouple with SMP connector\u003cbr\u003e \u003csup\u003e3\u003c\/sup\u003e Also accepts any K, J, or T-type thermocouple with SMP connector\u003cp\u003e\n\t\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817399591207,"sku":"OM-EL-21CFR-Series","price":387.59,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817399623975,"sku":"OM-EL-21CFR-Series","price":387.59,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-el-21cfr-tc-lcd_450_fn3stgstmbn8j6xo.jpg?v=1741316052"},{"product_id":"multi-channel-oven-temperature-data-logger","title":"Multi-channel Oven Temperature Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cp\u003eOven temperature profiling can help ensure that a quality product is consistently produced. Profiling enables users to optimize their process, prove process control and make corrections to a process when required. The OM-CP-THERMOVAULTX Series is a thermally insulated, battery powered, oven temperature recorder able to withstand extreme temperatures. It can withstand oven temperatures of up to 662 °F for up to 25 minutes when properly sealed. Its stainless steel enclosure and thermal properties lend itself to be the ideal temperature recording device for applications such as powder coating cure ovens, wet coating cure ovens, batch ovens and conveyor ovens. The external thermocouple probes provide accurate temperature measurements, with fast response times.\u003c\/p\u003e \u003cp\u003eOur user-friendly software easily downloads the data to a computer, where the readings may be displayed in degrees Celsius, degrees Fahrenheit, Kelvin or Rankine. The software allows the user to view all data points or a range of data points and a summary of the data being viewed for calculations such as Mean Kinetic Temperature (MKT). If additional analysis of the data needs to be performed, the data can be easily exported to Excel® by simply clicking a button.\u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"2\" style=\"width: 30%;\" bordercolor=\"#D8D8D8\"\u003e\n\u003cthead\u003e \u003ctr\u003e\u003cth colspan=\"2\"\u003e \u003cp align=\"left\"\u003eINTERNAL CHANNELS\u003c\/p\u003e \u003c\/th\u003e\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eTemperature \u003cbr\u003eRange\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e-20 °C to +60 °C (-4 °F to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eTemperature \u003cbr\u003e Resolution\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e0.01 °C (0.018 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eCalibrated \u003cbr\u003eAccuracy\u003c\/td\u003e \u003ctd align=\"left\"\u003e±0.5 °C (0 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e \u003ctr\u003e\u003cth colspan=\"2\"\u003e \u003cp align=\"left\"\u003eREMOTE CHANNELS\u003c\/p\u003e \u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eRemote Channel \u003cbr\u003eThermocouple\u003cbr\u003e Types\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eJ, K, T, E, R, S, B, N\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eThermocouple\u003cbr\u003e Connection\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eFemale subminiature (SMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eCold Junction\u003cbr\u003eCompensation\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eAutomatic, based on internal channel\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e\n\u003c\/table\u003e \u003cbr\u003e \u003ctable border=\"2\" style=\"width: 40%;\" bordercolor=\"#D8D8D8\"\u003e\n\u003cthead\u003e \u003ctr\u003e\u003cth colspan=\"4\"\u003e \u003cp align=\"left\"\u003eREMOTE CHANNELS\u003c\/p\u003e\n\u003c\/th\u003e\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e \u003ctd align=\"left\"\u003eRange (°C)\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy*\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e \u003ctd align=\"left\"\u003e-210 to +760\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e \u003ctd align=\"left\"\u003e-270 to +1370\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e \u003ctd align=\"left\"\u003e-270 to +400\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e \u003ctd align=\"left\"\u003e-270 to +980\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e \u003ctd align=\"left\"\u003e-50 to +1760\u003c\/td\u003e\n\u003ctd\u003e0.5 °C\u003c\/td\u003e\n\u003ctd\u003e±2.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e \u003ctd align=\"left\"\u003e-50 to +1760\u003c\/td\u003e\n\u003ctd\u003e0.5 °C\u003c\/td\u003e\n\u003ctd\u003e±2.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e \u003ctd align=\"left\"\u003e+50 to +1820\u003c\/td\u003e\n\u003ctd\u003e0.5 °C\u003c\/td\u003e\n\u003ctd\u003e±2.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e \u003ctd align=\"left\"\u003e-270 to +1300\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e \u003cbr\u003e \u003cp\u003e*Thermocouple accuracy is specified with a 24 AWG.\u003c\/p\u003e \u003ctable border=\"2\" style=\"width: 30%;\" bordercolor=\"#D8D8D8\"\u003e\n\u003cthead\u003e \u003ctr\u003e\u003cth colspan=\"2\"\u003e \u003cp align=\"left\"\u003eMAXIMUM EXPOSURE TIME\u003c\/p\u003e \u003c\/th\u003e\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003e\u003cstrong\u003eAmbient  Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px;\"\u003e\u003cstrong\u003eMaximum Duration in Minutes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003e100 °C (212 °F)\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003e150 °C (302 °F\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003e200 °C (392 °F)\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003e250 °C (482 °F)\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003e260 °C (500 °F)\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003e300 °C (572 °F)\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003e350 °C (662 °F)\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e \u003cbr\u003e \u003ctable border=\"2\" style=\"width: 30%;\" bordercolor=\"#D8D8D8\"\u003e\n\u003cthead\u003e \u003ctr\u003e\u003cth colspan=\"2\"\u003e \u003cp align=\"left\"\u003eGENERAL\u003c\/p\u003e \u003c\/th\u003e\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eMemory (All channels enabled)\u003c\/td\u003e \u003ctd style=\"padding: 10px;\"\u003e\n\u003cstrong\u003e4-channel:\u003c\/strong\u003e 524,032 readings per channel \u003cbr\u003e\u003cstrong\u003e 8-channel:\u003c\/strong\u003e 262,016 readings per channel\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eStart Modes\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eSoftware programmable immediate start \u003cbr\u003e or delay start, up to 6 months in advance\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eLEDs\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e1 per channel and 2 status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eReading Rate\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e4 Hz up to 1 reading every 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eCalibration\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eDigital calibration through software\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eCalibration Date\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eAutomatically recorded within device\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eBattery Type\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e9 V lithium included, user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eBattery Life\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e18 months typical\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eData Format\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eDate and time stamped °C, °F, K, °R, mV, V\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eTime Accuracy\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e±1 minute\/month\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eComputer  Interface\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eUSB-A to micro USB cable (included); 460,800 baud\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eOperating System Compatibility\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eWindows XP SP3\/7\/8\/10\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eSoftware Compatibility\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eStandard Software version 4.2.17.0 or later \u003cbr\u003e Secure Software version 4.2.16.0 or later\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eOperating  Environment\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003eSee table for temperature 0 %RH to 95 %RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eInternal OM-CPQUADTCTEMP-A2\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e-20 °C to +60 °C 0 %RH to 95 %RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eOM-CPTHERMOVAULTX SYSTEM\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e-20 °C to +350 °C 0 %RH to 95 %RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eDimensions\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e12.3 in x 6.65 in x 2.45 in  (723 mm x 168 mm x 62 mm) [Includes handles, brackets and front enclosure latches] 9.1 in x 5.9 in x 2.45 in  (231 mm x 149 mm x 62 mm) [Enclosure case only. Excludes handles, brackets and latches]\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd width=\"30%;\" style=\"padding: 10px;\"\u003eWeight\u003c\/td\u003e \u003ctd align=\"left\" style=\"padding: 10px;\"\u003e4-channel: 8.85 lb (4.01 kg) \u003cbr\u003e\u003cstrong\u003e8-channel:\u003c\/strong\u003e 8.98 lb (4.07 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817399886119,"sku":"OM-CP-XTHERMOVAULT-Series","price":4457.54,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817399918887,"sku":"OM-CP-XTHERMOVAULT-Series","price":4457.54,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/oct-thermo-vault_450_vcfosaidl6jkqjte.jpg?v=1741316084"},{"product_id":"2-channel-handheld-type-k-and-j-thermocouple-datalogger-usb","title":"2 Channel Handheld Type K and J Thermocouple Datalogger  USB","description":"\u003cp\u003eThe 2-Channel Handheld Thermocouple Data Logger supports both Type K and Type J probes, making it a versatile tool for monitoring temperature variations across two points simultaneously. Its lightweight design and built-in LCD display allow for easy in-the-field operation, while integrated memory stores precise temperature profiles for later review. With USB connectivity, downloading logged data is seamless, whether you're tracking thermal cycles in machinery, HVAC systems, or research experiments. Thanks to robust construction, long battery life, and user-friendly interfaces, this data logger is the perfect companion for engineers, maintenance teams, and scientists who need reliable thermal tracking wherever they work.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eDual input for Type K and Type J thermocouple probes\u003c\/p\u003e\n\n\u003cp\u003eBuilt-in display for real-time temperature logging\u003c\/p\u003e\n\n\u003cp\u003eInternal memory stores temperature data for later download\u003c\/p\u003e\n\n\u003cp\u003eUSB interface for quick data export\u003c\/p\u003e\n\n\u003cp\u003eCompact and durable for field or lab use\u003c\/p\u003e\n\n\u003cp\u003eIdeal for HVAC, machinery monitoring, and scientific applications\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817400115495,"sku":"HH300-303","price":422.64,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817400148263,"sku":"HH300-303","price":422.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/hh300_303_l_tkmojjorkm03fu3i.jpg?v=1741316097"},{"product_id":"portable-temperature-humidity-data-loggers-with-graphing-display","title":"Portable Temperature\/Humidity Data Loggers With Graphing Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-EL-GFX Series portable temperature\/ humidity data loggers measure and store up to 252,928 readings. Using the included Windows® control software users can quickly set up the data logger and view downloaded data by connecting the device to the computer’s USB port.\u003cbr\u003e\u003cbr\u003e The data logger features a high contrast graphic LCD display and three input buttons. This allows users to start, stop and restart the data logger using on-screen menus. The menu also provides real-time analysis of data either as a data summary (showing highest and lowest readings and alarm conditions) or as a graph that updates as new data is added. The maximum and minimum readings and also the time and date these are valid from can be displayed on the LCD display by using the info button. If desired, the user can then reset the maximum\/minimum readings shown. Each time the maximum\/minimum readings are reset while logging, an “event marker” is created in the data. When the data has been downloaded to the computer these events can be viewed on the graph (event markers), and they also appear in the data file associated with the corresponding log when the reset took place. This can be useful as an audit\/validation tool for certain applications where procedures mandate that a regular physical check of the logger\/statistics have taken place. Multiple data logging sessions can be stored on the device ready for upload to the computer at a later time.\u003cbr\u003e\u003cbr\u003e The data logger’s robust design provides IP67 waterproof protection (OM-EL-GFX-1, OM-EL-GFX-2 and OM-EL-GFX-2-PLUS only).\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOM-EL-GFX-1\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e -30 to 80°C (-22 to 176°F)\u003cbr\u003e \u003cb\u003eInternal Resolution:\u003c\/b\u003e 0.1°C (0.1°F)\u003cbr\u003e \u003cb\u003eAccuracy (Overall Error @ 25°C):\u003c\/b\u003e ±0.1°C (±0.2°F) typical; ±0.75°C (±1.5°F) maximum\u003cbr\u003e \u003cb\u003eLogging Interval:\u003c\/b\u003e 1 reading every 10 seconds to 1 every hour\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 6 months typical at 25°C (77°F) and 10 minute logging rate\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 99 g (3.5 oz)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 88 H x 48.5 W x 30.5 mm D (3.46 x 1.91 x 1.20')\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOM-EL-GFX-2, OM-EL-GFX-2-PLUS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eMeasurement Range:\u003c\/b\u003e -30 to 80°C (-22 to 176°F)\u003cbr\u003e     \u003cb\u003eRepeatability:\u003c\/b\u003e ±0.1°C (±0.2°F) typical\u003cbr\u003e     \u003cb\u003eInternal Resolution:\u003c\/b\u003e 0.1°C (0.1°F)\u003cbr\u003e     \u003cb\u003eAccuracy (Overall Error):\u003c\/b\u003e OM-EL-GFX-2; ±0.5°C (±1.0°F) typical; ±2.0°C (±4.0°F) maximum:\u003cbr\u003e OM-EL-GFX-2-PLUS; ±0.2°C (±0.4°F) typical; ±0.8°C (±1.6°F) maximum \u003cbr\u003e \u003cb\u003eHumidity\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 100% RH\u003cbr\u003e     \u003cb\u003eRepeatability:\u003c\/b\u003e ±0.5% RH\u003cbr\u003e     \u003cb\u003eLong Term Stability:\u003c\/b\u003e ±0.5% RH\/year\u003cbr\u003e     \u003cb\u003eInternal Resolution:\u003c\/b\u003e 0.1% RH\u003cbr\u003e     \u003cb\u003eAccuracy (20 to 80% RH):\u003c\/b\u003e OM-EL-GFX-2; ±3.0% RH typical; ±5.0% RH maximum:\u003cbr\u003e OM-EL-GFX-2-PLUS; ±1.8% RH typical; ±4.0% RH maximum\u003cbr\u003e \u003cb\u003eDew Point\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eAccuracy (Overall error in the calculated dew point, for RH measurement between 40 to 100% RH @ 25°C):\u003c\/b\u003e ±1.1°C (±2.0°F)\u003cbr\u003e \u003cb\u003eLogging Interval:\u003c\/b\u003e 1 reading every 10 seconds to 1 every hour\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 4 months typical at 25°C (77°F) and 10 minute logging rate\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 88 H x 48.5 W x 30.5 mm D (3.46 x 1.91 x 1.20')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 99 g (3.5 oz)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOM-EL-GFX-DTC (2 channels)\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOM-EL-GFX-TC (1 channel) \u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature Measurement Range:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eType K:\u003c\/b\u003e -200 to 1350°C (-328 to 2462°F)\u003cbr\u003e     \u003cb\u003eType J:\u003c\/b\u003e -200 to 1190°C (-328 to 2174°F)\u003cbr\u003e     \u003cb\u003eType T:\u003c\/b\u003e -200 to 390°C (-328 to 734°F)\u003cbr\u003e \u003cb\u003eInternal Resolution:\u003c\/b\u003e 0.1°C (0.1°F)\u003cbr\u003e \u003cb\u003eAccuracy (Overall Error @ 25°C):\u003c\/b\u003e ±0.5°C (±0.9°F) typical\u003cbr\u003e \u003cb\u003eOperating Temperature Range:\u003c\/b\u003e -10 to 40°C (-14 to 104°F)\u003cbr\u003e \u003cb\u003eLogging Interval:\u003c\/b\u003e 1 reading every 2 seconds to 1 every hour\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e\u003cbr\u003e      \u003cb\u003eOM-EL-GFX-DTC\u003c\/b\u003e: 4 months typical at 25°C (77°F) and 10 minute logging rate\u003cbr\u003e      \u003cb\u003eOM-EL-GFX-TC\u003c\/b\u003e: 1 year typical at 25°C (77°F) and 1 minute logging rate, LCD off\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 105 g (3.7 oz)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 102 H x 48.5 W x 30.5 mm D (4.06 x 1.91 x 1.20')\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOM-EL-GFX-DTP\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature Measurement Range (with Included Thermistor Probe):\u003c\/b\u003e -40 to 125°C (-40 to 257°F)\u003cbr\u003e \u003cb\u003eInternal Resolution:\u003c\/b\u003e 0.1°C (0.2°F)\u003cbr\u003e \u003cb\u003eAccuracy (Data Logger Error @ 25°C):\u003c\/b\u003e ±0.1°C (±0.2°F) typical (does not include thermistor probe error)\u003cbr\u003e \u003cb\u003eAccuracy (Thermistor Probe):\u003c\/b\u003e See chart on PDF\u003cbr\u003e \u003cb\u003eOperating Temperature Range:\u003c\/b\u003e -10 to 40°C (-14 to 104°F)\u003cbr\u003e \u003cb\u003eLogging Interval:\u003c\/b\u003e 1 reading every 2 seconds to 1 every hour\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 4 months typical at 25°C (77°F) and 10 minute logging rate\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eData Logger:\u003c\/b\u003e 101 H x 48.5 W x 30.5 mm D (3.98 x 1.91 x 1.20')\u003cbr\u003e     \u003cb\u003eThermistor Probe:\u003c\/b\u003e\u003cbr\u003e       \u003cb\u003eCable:\u003c\/b\u003e 1 m (3')\u003cbr\u003e       \u003cb\u003eProbe Tip:\u003c\/b\u003e Stainless steel, 25 L x 5 mm dia (1 x 0.18')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 105 g (3.7 oz)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCOMMON SPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 252,928 readings\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows XP\/VISTA\/7 and 8 (32 and 64-bit)\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 2 ½ “AA” 3.6V lithium batteries (included)\u003cbr\u003e \u003cb\u003eEnclosure:\u003c\/b\u003e IP67 with USB cover attached (excludes OM-EL-GFX-DTC, OM-EL-GFX-TC and OM-EL-GFX-DTP)\u003cbr\u003e \u003cb\u003eDisplay:\u003c\/b\u003e High contrast graphic backlit LCD \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817400639783,"sku":"OM-EL-GFX-Series","price":446.0,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817400672551,"sku":"OM-EL-GFX-Series","price":446.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-el-gfx_l_knpj92epvepg6899.jpg?v=1741316124"},{"product_id":"x-series-multi-channel-thermocouple-datalogger-w-lcd","title":"X-Series - Multi-channel Thermocouple Datalogger w\/ LCD","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cp\u003eThe OM-CP-QUADTCTEMP2000-A2 and OM-CP-OCTTCTEMP2000-A2 are four and eight channel thermocouple data loggers with an LCD screen. The device features on-screen minimum, maximum and average statistics, as well as a user configurable screen that allows for any combination of channels to be displayed. The device accepts J, K, T, E, R, S, B and N type thermocouples.\u003c\/p\u003e\n\u003cp\u003e The OM-CP-QUADTCTEMP2000-A2 and OM-CP-OCTTCTEMP2000-A2 are ideal for a variety of applications, whether it is remote temperature monitoring, or multiple points in a central location. Data from all channels is simultaneously logged and displayed on-screen for real-time monitoring. It can then be downloaded to a PC for further analysis.\u003c\/p\u003e\n\u003ctable border=\"2\" class=\"tb-border\" style=\"width: 70%;\" bordercolor=\"#dddddd\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth colspan=\"2\" style=\"background-color: #d8d8d8; width: 1px; border: 0.5px solid black;text-align:left\"\u003eINTERNAL CHANNELS  \u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003e Temperature Range\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-20 °C to +60 °C (-4 °F to +140 °F)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eTemperature Resolution\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.01 °C (0.018 °F)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003e Calibrated Accuracy\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±0.5 °C (0 °C to 50 °C)\u003cbr\u003e ±0.9 °F (32 °F to 131 °F) \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003cthead\u003e \u003ctr\u003e \u003cth colspan=\"2\" style=\"background-color: #d8d8d8; width: 1px; border: 0.5px solid black;text-align:left\"\u003eREMOTE CHANNELS\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eRemote Channel Thermocouple Types\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eJ, K, T, E, R, S, B, N\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eThermocouple Connection\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eFemale subminiature (SMP)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eCold Junction Compensation\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eAutomatic, based on internal channel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eMaximum Thermocouple Resistance\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e1000 Ω, \u0026lt;100 Ω recommended\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003cbr\u003e \u003ctable border=\"2\" class=\"tb-border\" style=\"width: 70%;\" bordercolor=\"#dddddd\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth colspan=\"4\" style=\"background-color: #d8d8d8; width: 1px; border: 0.5px solid black;text-align:left\"\u003eREMOTE CHANNELS\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eThermocouple\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eRange (°C) \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eResolution \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eAccuracy* \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eJ\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-210 to +760 \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.1 °C \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±0.5 °C \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eK \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-270 to +1370 \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.1 °C \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±0.5 °C \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eT\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-270 to +400 \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.1 °C \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±0.5 °C \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eE\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-270 to +980 \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.1 °C \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±0.5 °C \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eR\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-50 to +1760 \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.5 °C \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±2.0 °C \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eS\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-50 to +1760 \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.5 °C \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±2.0 °C \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eB\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e+50 to +1820 \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.5 °C \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±2.0 °C \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eN\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-270 to +1300 \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e0.1 °C \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±0.5 °C \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e*Thermocouple accuracy specified with 24 AWG diameter thermocouple wires.\u003c\/p\u003e \u003ctable border=\"2\" class=\"tb-border\" style=\"width: 70%;\" bordercolor=\"#dddddd\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth colspan=\"2\" style=\"background-color: #d8d8d8; width: 1px; border: 0.5px solid black;text-align:left\"\u003eGENERAL\u003c\/th\u003e\n\u003c\/tr\u003e  \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eMemory\u003cbr\u003e (All channels\u003cbr\u003e enabled)\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e4-channel: 524,032 readings per channel\u003cbr\u003e 8-channel: 262,016 readings per channel \u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eStart Modes \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eSoftware programmable immediate start\u003cbr\u003e or delay start, up to 6 months in advance \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eReal Time Recording \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eMay be used with PC to monitor and\u003cbr\u003e record data in real time \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eLEDs\u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e1 per channel and 2 status LEDs \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eReading Rate \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e4 Hz up to 1 reading every 24 hours \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eCalibration \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eDigital calibration through software \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eCalibration Date \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eAutomatically recorded within device\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eBattery Type \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e9 V lithium included, user replaceable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eBattery Life \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e18 months typical with display off. \u003cbr\u003e3 months typical with continuous display use.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eData Format \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eDate and time stamped °C, °F, K, °R, mV, V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eTime Accuracy \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e±1 minute\/month\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eComputer Interface \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eUSB-A to micro USB cable (included); \u003cbr\u003e460,800 baud\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eOperating\u003cbr\u003eSystem\u003cbr\u003eCompatibility \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eWindows XP SP3\/7\/8\/10\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eSoftware Compatibility \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eStandard Software version 4.2.21 or later\u003cbr\u003e Secure Software version 4.2.18 or later\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eOperating Environment \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e-20 °C to +60 °C (-4 °F to +140 °F),\u003cbr\u003e 0 %RH to 95 %RH non-condensing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eDimensions \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e4-channel: 7.25 in x 2.70 in x 1.22 in\u003cbr\u003e (184.15mm x 65.58 mm x 30.99 mm)\u003cbr\u003e 8-channel: 7.25 in x 2.70 in x 1.68 in\u003cbr\u003e (184.15mm x 65.58 mm x 42.672 mm)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eWeight \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003e4-channel: 15.3 oz (435 g)\u003cbr\u003e 8-channel: 20.1 oz (569 g)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eEnclosure \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eBlack anodized aluminum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"border: 1px solid black;\"\u003eApprovals \u003c\/td\u003e \u003ctd style=\"border: 1px solid black;\"\u003eCE\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817401229607,"sku":"OM-CP-XTCTemp2000-Srs","price":3042.32,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817401262375,"sku":"OM-CP-XTCTemp2000-Srs","price":3042.32,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-xtctemp2000-srs_450_ffxkxlqccefdfyke.jpg?v=1741316147"},{"product_id":"2-channel-2-thermocouple-types-wireless-and-usb-datalogger","title":"2 Channel 2 Thermocouple Types Wireless and USB Datalogger","description":"\u003cp\u003eThe 2-Channel, 2 Thermocouple Types Wireless \u0026amp; USB Datalogger is a versatile device designed for simultaneous temperature monitoring using two different thermocouple types. Its wireless and USB connectivity options allow for convenient data transfer and analysis. This datalogger is ideal for applications in research, manufacturing, and environmental monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eSupports two different thermocouple types for versatile temperature monitoring\u003c\/p\u003e\n\n\u003cp\u003eWireless and USB connectivity for convenient data transfer\u003c\/p\u003e\n\n\u003cp\u003eSuitable for research, manufacturing, and environmental monitoring\u003c\/p\u003e\n\n\u003cp\u003eCompact and portable design for easy deployment\u003c\/p\u003e\n\n\u003cp\u003eEasy-to-use software for data analysis\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817401524519,"sku":"HH802-803","price":499.92,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817401557287,"sku":"HH802-803","price":499.92,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/hh802_803_l_0fohkgqkfsxhzec9.jpg?v=1741316169"},{"product_id":"waterproof-thermocouple-data-logging-system-with-remote-probe","title":"Waterproof Thermocouple Data Logging System with Remote Probe","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-ETR101A-KIT comes assembled and includes a data logger, temperature sensor (thermocouple Type K), waterproof NEMA 4 (IP65) enclosure suitable for outdoor use, USB interface cable, and software. Setup is fast and easy. \u003cbr\u003e\u003cbr\u003e The OM-CP-ETR101A-KIT is suitable for a wide range of outdoor applications including profiling the exhaust gas temperature of tractor trailers, buses and trucks. Simply mount the enclosure containing the data logger to the vehicle and insert the included type K thermocouple probe into the vehicle exhaust pipe using a compression fitting. The data logger can then record a complete exhaust gas temperature profile that can be used in the selection of the correct diesel particulate filter (DPF) for the vehicle. \u003cbr\u003e\u003cbr\u003e Using the included software, the logger is programmed to record for a set period. Data is stored in the data logger, and is downloadable at any time via a pc or laptop computer. \u003cbr\u003e\u003cbr\u003e The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. Its small size allows it to fit almost anywhere. Data retrieval is simple. Plug it into an available USB port and the easy to use Windows® software does the rest. The software converts your PC into a real time strip chart recorder. Data can be printed in tabular format and can also be exported to a text or Microsoft Excel® file. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e INTERNAL CHANNEL\u003cbr\u003e Temperature Range:\u003c\/b\u003e -40 to 80°C (-40 to 176°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.1°C (0.18°F)\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±0.25°C (±0.45°F) \u003cbr\u003e\u003cbr\u003e \u003cb\u003eREMOTE CHANNEL\u003cbr\u003e Thermocouple Types: \u003c\/b\u003eK**\u003cbr\u003e \u003cb\u003eTemperature Range:\u003c\/b\u003e -270 to 1070°C (-454 to 1958°F)\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e ±2.0°C (24 AWG wire)\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.1°C\u003cbr\u003e \u003cb\u003eThermocouple Connection:\u003c\/b\u003e Female subminiature (SMP) connector \u003cbr\u003e \u003cb\u003eCold Junction Compensation: \u003c\/b\u003eAutomatic based on internal channel\u003cbr\u003e \u003cb\u003eMax Thermocouple Resistance: \u003c\/b\u003e100 Ω \u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e 1 reading every second to 1 every 24 hours\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 500,000 readings (software configurable memory wrap); \u003cbr\u003e250,000 readings in multiple start\/stop mode or trigger setting mode\u003cbr\u003e \u003cb\u003eWrap Around: \u003c\/b\u003eYes\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003e•\u003c\/b\u003e Immediate start\u003cbr\u003e \u003cb\u003e•\u003c\/b\u003e Delay start up to 18 months\u003cbr\u003e \u003cb\u003e•\u003c\/b\u003e Multiple pushbutton start\/stop\u003cbr\u003e \u003cb\u003eMultiple Start\/Stop Mode: \u003c\/b\u003eStart and stop the device multiple times\u003cbr\u003e without having to download data or communicate with a PC\u003cbr\u003e \u003cb\u003eMultiple Start\/Stop Mode Activation:\u003cbr\u003e   To Start the Device:\u003c\/b\u003e\u003cbr\u003e   Press and hold the pushbutton for 5 seconds, the green LED will flash during this time. \u003cbr\u003e   The device has started logging.\u003cbr\u003e   \u003cb\u003eTo Stop the Device:\u003c\/b\u003e\u003cbr\u003e   Press and hold the pushbutton for 5 seconds, the red LED will flash during this time. \u003cbr\u003e   The device has stopped logging.\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e The device may be used with PC to monitor and record data in real-time\u003cbr\u003e \u003cb\u003eAlarm: \u003c\/b\u003eProgrammable high and low limits; alarm is activated when temperature \u003cbr\u003ereaches or exceeds set limits\u003cbr\u003e   \u003cb\u003eAlarm Delay:\u003c\/b\u003e A cumulative alarm delay may be set in which the device will activate that alarm\u003cbr\u003e    (via LED) only when the device has recorded a user specified time duration of data\u003cbr\u003e \u003cb\u003eTrigger Settings: \u003c\/b\u003eHigh and low limits may be set for the thermocouple channel. Once data meets or exceeds sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number or readings to take after the device triggers.\u003cbr\u003e \u003cb\u003eLED Functionality:\u003cbr\u003e   Green LED Blinks: \u003c\/b\u003e10 second rate to indicate logging 15 second rate to indicate delay start mode\u003cbr\u003e   \u003cb\u003eRed LED Blinks:\u003c\/b\u003e 10 second rate to indicate low battery and\/or full memory 1 second rate to indicate   an alarm condition\u003cbr\u003e \u003cb\u003ePassword Protection: \u003c\/b\u003eAn optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e 3.6V lithium battery (included); user replaceable\u003cbr\u003e \u003cb\u003eBattery Life: \u003c\/b\u003e10 years typical at a 15 minute reading rate\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped °C, °F, K, °R; µV, mV, V\u003cbr\u003e \u003cb\u003eTime Accuracy: \u003c\/b\u003e±1 minute\/month (at 20ºC, stand alone data logging)\u003cbr\u003e \u003cb\u003eComputer Interface: \u003c\/b\u003eUSB (interface cable required); 115,200 baud\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e XP SP3\/Vista\/7 and 8 (32 and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment: \u003c\/b\u003e-20 to 80ºC (-4 to 176°F), 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eDimensions:\u003cbr\u003e   Data Logger:\u003c\/b\u003e 36 H x 56 W x 16 mm D (1.4 x 2.2 x 0.6')\u003cbr\u003e   \u003cb\u003eWaterbox:\u003c\/b\u003e 87 H x 73 W x 27 mm D (3.5 x 2.9 x 1.1')\u003cbr\u003e   \u003cb\u003eThermocouple Wire: \u003c\/b\u003e24 gauge, 762 mm (30')\u003cbr\u003e   \u003cb\u003eThermocouple Probe: \u003c\/b\u003e153 L x 3.2 mm dia. (6 x 1?8')\u003cbr\u003e \u003cb\u003eWeight:\u003cbr\u003e   Complete Kit:\u003c\/b\u003e 425 g (15 oz)\u003cbr\u003e   \u003cb\u003eWaterproof Enclosure, Data Logger and Thermocouple:\u003c\/b\u003e 283 g (10 oz) \u003cbr\u003e\u003cbr\u003e **Use of stanless steel braided thermocouple may allow water to wick in through the cable and cause damage to the data logger \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817401884967,"sku":"OM-CP-ETR101A-KIT-Series","price":889.16,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817401917735,"sku":"OM-CP-ETR101A-KIT-Series","price":889.16,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-etr101a-kit_l_lpwrj7ziu53vtllt.jpg?v=1741316192"},{"product_id":"single-channel-usb-thermocouple-data-logger-with-lcd-display","title":"Single Channel USB Thermocouple Data Logger with LCD Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e New OM-20A-T thermocouple data logger with LCD Display measures and stores over 85,000 temperature readings from either a Type K, Type J, Type S, or Type T\u0026amp;R thermocouple which plugs into a miniature female thermocouple receptacle at the base of the unit.\u003cbr\u003e\u003cbr\u003e This data logger's compact size make it an ideal choice for any portable application including monitoring temperature in factory, storage, testing process, etc. User needs to install USB driver and PC Software that run under Windows XP, Vista, 7, 8 or 10 (32 bit and 64 bit Versions), and use the software to setup sample rate, high\/low alarm limit and start\/stop method, and download data to PC, etc. And then view, analyze and print the data, or export other file formats (txt, xsl, csv, bmp, jpg).\u003cbr\u003e\u003cbr\u003e Especially, in professional applications, user can set access password, name the channel, enable\/disable channel, input calibration data for each channel, disable LED indication for saving power, and select sample mode (Instant, Average, Maximum and Minimum), etc.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eInput Type: \u003c\/strong\u003eSupport 5 Thermocouple Types K, J, S, T \u0026amp; R\u003cbr\u003e \u003cstrong\u003eAccuracy: \u003c\/strong\u003e±0.5% Reading ±1 Deg_C \u003cbr\u003e \u003cstrong\u003eResolution: \u003c\/strong\u003e0.1 Deg_C\u003cbr\u003e \u003cstrong\u003eTemperature Units: \u003c\/strong\u003e°C or °F \u003cbr\u003e \u003cstrong\u003eLogging Interval: \u003c\/strong\u003e2Secs-24Hrs, selectable in software\u003cbr\u003e \u003cstrong\u003eMemory Capacity: \u003c\/strong\u003e85,000 Points\u003cbr\u003e \u003cstrong\u003eThermocouple Connection: \u003c\/strong\u003eFemale sub-miniature thermocouple connector\u003cbr\u003e \u003cstrong\u003eLCD Display: \u003c\/strong\u003e4 Digits\u003cbr\u003e \u003cstrong\u003eBattery Type: \u003c\/strong\u003eLithium\u003cbr\u003e \u003cstrong\u003eBattery Life: \u003c\/strong\u003eUp to 2 years \u003cbr\u003e \u003cstrong\u003eOperating Temperature: \u003c\/strong\u003e -35 Deg_C to 80 Deg_C \u003cbr\u003e \u003cstrong\u003eSoftware: \u003c\/strong\u003eWindows XP, Vista, 7, 8 or 10 (32 bit and 64 bit Versions) \u003cbr\u003e \u003cstrong\u003eCase Material: \u003c\/strong\u003eIP40\u003cbr\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817402179879,"sku":"OM-20A-TC-Logger","price":220.91,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817402212647,"sku":"OM-20A-TC-Logger","price":220.91,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-20a-tc_l_ashplwvzsgc0eytg.jpg?v=1741316215"},{"product_id":"single-use-cold-chain-pdf-temperature-logger-for-audit-reports","title":"Single use Cold Chain PDF Temperature Logger for Audit Reports","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cp\u003e The OM-21 data logger is for use in cold chain applications to monitor the transportation of pharmaceuticals, food and other temperature sensitive products. The data logger is completely user-programmable including language selection, sampling interval, start delay, alarm delay, temperature units, alarm range, alarm type, password and user name. The unit’s compact, lightweight, waterproof and flat design allows it to fit inside any package. No special software or driver is required for set-up or download of data. On completion of data logging a PDF report is automatically generated containing data summary, graph and tabular results. The data logger appears as a mass storage device when connected to the PC. User manual, set-up utility and PDF report are all stored in the data logger.\u003cbr\u003e\u003cbr\u003e\u003cb\u003e Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTEMPERATURE\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSensor:\u003c\/b\u003e Thermistor\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e -30 to 70°C (-22 to 158°F)\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e ±0.5°C\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.1°C (0.1°F)\u003cbr\u003e \u003cb\u003eUnits:\u003c\/b\u003e °C or °F\u003cbr\u003e \u003cb\u003eLogging Type:\u003c\/b\u003e Single use\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 8192 readings\u003cbr\u003e \u003cb\u003eSampling Interval:\u003c\/b\u003e 30 seconds, 5, 10, 30, 60, 90, 120 minutes\u003cbr\u003e \u003cb\u003eData Integrity:\u003c\/b\u003e File encrypted technology ensures data integrity\u003cbr\u003e \u003cb\u003ePassword:\u003c\/b\u003e Can be ON or OFF (default is OFF); password can be up to 16 alpha-numeric characters\u003cbr\u003e \u003cb\u003eCompatibility:\u003c\/b\u003e Windows XP\/Vista\/7 and 8\u003cbr\u003e \u003cb\u003eStart Delay:\u003c\/b\u003e 0, 5, 30, 45, 60, 90, 120 minutes\u003cbr\u003e \u003cb\u003eAlarms:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eSingle:\u003c\/b\u003e A LED alarm is triggered immediately when the measured value exceeds the alarm threshold\u003cbr\u003e     \u003cb\u003eCumulative:\u003c\/b\u003e A LED alarm is not triggered when the measured value exceeds the alarm threshold, but only once the overall average value during alarm delay duration exceeds the alarm threshold\u003cbr\u003e     \u003cb\u003eDisable:\u003c\/b\u003e No LED alarm function during the logging process\u003cbr\u003e \u003cb\u003eAlarm Range:\u003c\/b\u003e -20 to -10°C (-4 to 14°F), -10 to 0°C (14 to 32°F), 2 to 8°C (36 to 46°F) (low alarm below 2°C, high alarm above 8°C), 0 to 15°C (32 to 59°F), 0 to 25°C (32 to 77°F), 15 to 25°C (59 to 77°F) (other ranges possible)\u003cbr\u003e \u003cb\u003eAlarm Delay:\u003c\/b\u003e Preset alarm delay for single alarm type is always zero; the adjustable alarm delay time for cumulative alarm type is user-selectable at 5, 30, 45, 60, 90, or 120 minutes\u003cbr\u003e \u003cb\u003eLanguage:\u003c\/b\u003e English (default), German, French, Italian, Spanish\u003cbr\u003e \u003cb\u003eOperation:\u003c\/b\u003e 2 keys; start\/stop key and mark key (provides up to 8 bookmarks during the data logging period)\u003cbr\u003e \u003cb\u003eLED Indicators:\u003c\/b\u003e REC, low battery, high alarm, low alarm\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -30 to 70°C (-22 to 158°F)\u003cbr\u003e \u003cb\u003eOperating Humidity:\u003c\/b\u003e \u0026lt;80% RH\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eStorage Humidity:\u003c\/b\u003e \u0026lt;90% RH\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 3V lithium battery (CR2032) factory installed\u003cbr\u003e \u003cb\u003eShelf Life:\u003c\/b\u003e 12 months\u003cbr\u003e \u003cb\u003eProtection Class:\u003c\/b\u003e IP65 (when contained in the included plastic bag)\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 10 g (0.35 oz)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eUnpouched Size:\u003c\/b\u003e 73 L x 33 W x 2.5 mm D (2.87 x 1.30 x 0.10')\u003cbr\u003e     \u003cb\u003ePouched Size (data logger inside included plastic bag):\u003c\/b\u003e 105 L x 55 W x 2.5 mm D (4.13 x 2.17 x 0.10') \u003c\/p\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817402376487,"sku":"OM-21-Logger","price":677.06,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817402409255,"sku":"OM-21-Logger","price":677.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-21_l_xs5bqaqaey4gr5nk.jpg?v=1741316237"},{"product_id":"8-input-portable-thermometer-data-logger-with-sd-card","title":"8 Input Portable Thermometer\/Data Logger with SD card","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan\u003e \u003cb\u003e\u003cspan style=\"color: red;\"\u003e RDXL8 logger is in the end of its life cycle. As a possible substitute \u0026amp; upgrade, please check out Newest Released 8 Channel Thermocouple Data Logger \u003ca href=\"..\/p\/OM-HL-EH-TC\" target=\"_blank\"\u003e OM-HL-EH-TC Series \u003c\/a\u003e or 8 Channel Universal Data Logger \u003ca href=\"..\/p\/OM-CP-OCTPRO\" target=\"_blank\"\u003e OM-CP-OCTPRO Series \u003c\/a\u003e for more advanced features with better price.\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e The RDXL8 with its high resolution and fast analog to digital converter will meet the data logging requirements in most industrial applications. The ability to show measured values and to analyze them on its graphical display eliminates the need to download collected data to a computer for further analysis. The RDXL8 is the perfect choice for remote logging, and ideal for use as a mobile measuring device for the industrial environment. The RDXL8 series multipoint data logger is valuable in the industry because of their ability to perform integrated recording, profiling and archiving functions. They offer display versatility and flexible data storage. Using a 2G SD: RDXL8 can store upto 119,836,800 points of data for 8 channels at the same time \u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e RDXL8: Eight 1.5V “AA” alkaline batteries (included) RDXL8CD: One 11.1v lithium battery (included)\u003cbr\u003e \u003cb\u003eAC Adaptor:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eDC:\u003c\/b\u003e Regulated 12V\/300 mA output\u003cbr\u003e     \u003cb\u003eAC:\u003c\/b\u003e 110V or 220V input\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 100 mA (with backlight), 70 mA (without backlight) Cold Junction Compensation\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e ±0.5°C\/±0.9°F\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e 0.01% of FS\/°C\u003cbr\u003e \u003cb\u003eIsolated Input Protection Between Any Two Inputs:\u003c\/b\u003e 350 Vp -p\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 257 L x 155 W x 57 mm D (10.1 x 6.1 x 2.2')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 1160 g (40.9 oz) (with batteries)\u003cbr\u003e \u003cb\u003eOperation Environment:\u003c\/b\u003e 0 to 50°C, 85% RH\u003cbr\u003e \u003cb\u003eStorage Environment:\u003c\/b\u003e -20 to 60°C, 75% RH \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817402671399,"sku":"RDXL8-Series","price":5885.88,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817402704167,"sku":"RDXL8-Series","price":5885.88,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/rdxl8_l_dlyx0hyznibvww5b.jpg?v=1741316259"},{"product_id":"compact-usb-temperature-and-relative-humidity-data-logger","title":"Compact USB Temperature and Relative Humidity Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\tThe OM-62 temperature\/relative humidity data logger is an easy-to-use, versatile device which can be used for a wide range of logging applications. The OM-62 is capable of sampling as fast as once per second or as slow as every 18 hours. A total of 43,344 temperature measurements can be stored in the data logger memory if only temperature is measured, or 21,672 measurements for temperature and humidity. \u003cbr\u003e\u003cbr\u003e In addition to measuring temperature and relative humidly, the easy-to-use Windows software included with the OM-62 data logger calculates and displays the dew point temperature. The software is a full-featured program that allows you to set up all data logger functions including sampling rate, logging duration, start mode, logging mode, and high and low temperature and relative humidity alarm values.\u003cbr\u003e Once data has been logged, the program then allows you to download data from the logger, plot the data and export the data to an ASCII text or Excel file format for further analysis. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e Temperature Measurement Range:\u003c\/b\u003e\u003cbr\u003e -40 to 70°C (-40 to 160°F)\u003cbr\u003e \u003cb\u003eTemperature Sensor:\u003c\/b\u003e Internal digital sensor\u003cbr\u003e \u003cb\u003eRelative Humidity Range:\u003c\/b\u003e\u003cbr\u003e 0 to 99% RH, non-condensing\u003cbr\u003e \u003cb\u003eRelative Humidity Sensor:\u003c\/b\u003e\u003cbr\u003e Polymer capacitive\u003cbr\u003e \u003cb\u003eTemperature Accuracy:\u003c\/b\u003e\u003cbr\u003e ±0.5°C (±1°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e\u003cbr\u003e ±0.1°C (±0.1°F)\u003cbr\u003e \u003cb\u003eRelative Humidity Accuracy:\u003c\/b\u003e\u003cbr\u003e ±2% RH from 10 to 90% RH\u003cbr\u003e \u003cb\u003eRelative Humidity Resolution:\u003c\/b\u003e 0.01% RH\u003cbr\u003e \u003cb\u003eTemperature and Relative Humidity Alarms:\u003c\/b\u003e\u003cbr\u003e Programmable high and low alarm thresholds, \u003cbr\u003efor both temperature and humidity\u003cbr\u003e \u003cb\u003eSampling Rate: \u003c\/b\u003eUser selectable, 1 second to 18 hours, \u003cbr\u003ein 1 second increments\u003cbr\u003e \u003cb\u003eData Storage: \u003c\/b\u003e43,344 for temperature only;\u003cbr\u003e 21,672 for temperature and humidity\u003cbr\u003e \u003cb\u003eRecording Mode:\u003c\/b\u003e User selectable; stop on memory full\u003cbr\u003e or continuous recording with memory rollover\u003cbr\u003e \u003cb\u003eRecording Start:\u003c\/b\u003e Push button, computer controlled, \u003cbr\u003eor up to 6 week delayed start\u003cbr\u003e \u003cb\u003ePC Interface: \u003c\/b\u003eUSB Calibration: Single point offset calibration \u003cbr\u003e available through software for both temperature and humidity\u003cbr\u003e \u003cb\u003eTime Accuracy: \u003c\/b\u003e±100 ppm @ 75°F\u003cbr\u003e \u003cb\u003ePower: \u003c\/b\u003e3.0 V lithium battery (included)\u003cbr\u003e \u003cb\u003eBattery Life: \u003c\/b\u003e6 years typical\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 70°C (-40 to 160°F)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 76 x 40 x 15 mmD (3.0 x 1.6 x 0.6')\u003cbr\u003e \u003cb\u003eCompatibility:\u003c\/b\u003e Windows XP\/Vista\/7 and 8 (32-bit and 64-bit)\u003cbr\u003e \u003cb\u003eWeight: \u003c\/b\u003e28 g (1 oz)\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817402835239,"sku":"OM-62-Series","price":371.3,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817402868007,"sku":"OM-62-Series","price":371.3,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-62_l_55h2z3e99qhwnws8.jpg?v=1741316283"},{"product_id":"pen-size-temperature-and-humidity-usb-data-logger-with-display","title":"Pen Size Temperature and Humidity USB Data Logger with Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e \u003cspan style=\"float:right; margin:10px;\"\u003e \u003ciframe width=\"400\" height=\"280\" src=\"https:\/\/www.youtube.com\/embed\/ocD1ouG369Y\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003cbr\u003e \u003ccenter\u003e\u003cb\u003eOM-HL-SP Series Highlight\u003c\/b\u003e\u003c\/center\u003e \u003c\/span\u003e OM-HL-SP Series include temperature only and temperature \u0026amp; humidity data loggers with USB interface are specifically designed for applications like Food Processing, Bio-Medical, Cold-chain transportation and Wild Life Monitoring.\u003cbr\u003e\u003cbr\u003e The pen-sized design is IP67 rated, ensuring a high-grade waterproof and dust-proof resistance, plus the energy-saving battery can work up to 12 months before battery replacement is needed. \u003cb\u003eStarting from $60\u003c\/b\u003e, this OM-HL-SP Series offer excellent user experience to start and stop logging by Button, Delay or Specific Time. Simply plug-n-play to view, download and chart graphical data by using the free Logpro software.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature Range:\u003c\/b\u003e -30 to 70°C (-22 to 158°F)\u003cbr\u003e \u003cb\u003eTemperature Accuracy:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-HL-SP-T:\u003c\/b\u003e ±1.0°C\u003cbr\u003e     \u003cb\u003eOM-HL-SP-TH:\u003c\/b\u003e ±0.5°C\u003cbr\u003e \u003cb\u003eRecord Volume:\u003c\/b\u003e 43,000 Points\u003cbr\u003e \u003cspan style=\"float:right; margin:10px;\"\u003e \u003ciframe width=\"400\" height=\"280\" src=\"https:\/\/www.youtube.com\/embed\/e0QC0RV4Vuo\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003cbr\u003e \u003ccenter\u003e\u003cb\u003eOM-HL-SP Operation Instruction\u003c\/b\u003e\u003c\/center\u003e \u003c\/span\u003e \u003cb\u003eHumidity Range:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-HL-SP-T:\u003c\/b\u003e NA\u003cbr\u003e     \u003cb\u003eOM-HL-SP-TH:\u003c\/b\u003e 0-95% RH\u003cbr\u003e \u003cb\u003eHumidity Accuracy: \u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-HL-SP-T:\u003c\/b\u003e NA\u003cbr\u003e     \u003cb\u003eOM-HL-SP-TH:\u003c\/b\u003e ±5% RH\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e Temperature: 0.1°C \/ Humidity: 0.1% RH\u003cbr\u003e \u003cb\u003ePower Supply:\u003c\/b\u003e 1\/2AA, 3.6V Lithium battery - included\u003cbr\u003e \u003cb\u003eTypical Battery Life:\u003c\/b\u003e 1 year\u003cbr\u003e \u003cb\u003eIP Rating:\u003c\/b\u003e NEMA 6 (IP67)\u003cbr\u003e \u003cb\u003eFrequenty:\u003c\/b\u003e 2 Secs to 24 Hrs\u003cbr\u003e \u003cb\u003eDisplay:\u003c\/b\u003e LCD display\u003cbr\u003e \u003cb\u003eLCD Size:\u003c\/b\u003e 18 L x 13.5 W mm (0.7 x 0.53\")\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 125 L x 28 W x 22 Dia mm (4.92 x 1.1 x 0.86\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 60 g (2.1 oz)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eLogpro Recorder Analysis Software\u003c\/b\u003e\u003cbr\u003e Logpro software is comprehensive temperature and humidity recorder data analysis software designed to log attribute settings, download logger data efficiently, graphically analyze data, and export the data to Excel\/PDF\/BMP, and other formats by needs. \u003cbr\u003e\u003cbr\u003e The software interface is easy to use and efficient for ultimate data logging, monitoring, and analysis. Please see the Software Setup Video for more details. \u003cbr\u003e\u003cbr\u003e \u003cspan style=\"float:right; margin:10px;\"\u003e \u003ciframe width=\"400\" height=\"280\" src=\"https:\/\/www.youtube.com\/embed\/xtbzZHt0vXQ\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003cbr\u003e \u003ccenter\u003e\u003cb\u003eOM-HL-SP Software Setup\u003c\/b\u003e\u003c\/center\u003e \u003c\/span\u003e \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817403261223,"sku":"OM-HL-SP-Series","price":216.59,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817403293991,"sku":"OM-HL-SP-Series","price":216.59,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-hl-sp_l_r7q2kn2mvoviowvo.jpg?v=1741316307"},{"product_id":"high-temperature-data-logger-with-stainless-steel-flexible-probe","title":"High Temperature Data Logger with Stainless Steel Flexible Probe","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-HITEMP140-PT Series are submersible, temperature data loggers that can operate up to 140°C (284°F) and have an accuracy of ±0.1°C (0.18°F). These devices feature a 559 mm (22') flexible stainless steel probe for measuring extended temperatures up to 260°C (500°F). The probe is durable and can be spiraled, bent or angled in any direction, making it easy to log temperatures within bottles, vials or other hard to reach places. \u003cbr\u003e\u003cbr\u003e The OM-CP-HITEMP140-PT records date and time stamped readings, and has non-volatile solid state memory that will retain data even if the battery becomes discharged. Data retrieval is simple. Plug the device into an available USB port and our easy-to-use software does the rest. The software converts a PC into a real-time strip chart recorder. \u003cbr\u003e\u003cbr\u003e Using the software, starting, stopping and downloading the OM-CP-HITEMP140-PT is simple and easy. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R. The data can also be automatically exported to Excel® for further calculations. \u003cbr\u003e\u003cbr\u003e The OM-CP-HITEMP140-TSK is a kit that includes a OM-CP-HITEMP140-PT data logger housed in a thermal shield. The combined features of the ±0.1°C accuracy of the OM-CP-HITEMP140-PT and the properties of the durable thermal shield allow the device to be used for a wide range of validation applications. Using the software, the data logger is fast and easy to setup. Remove the thermal shield and place the OM-CP-HITEMP140-PT into the OM-CP-IFC400 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Select Start to program the settings and start the data logger. \u003cbr\u003e\u003cbr\u003e Place the thermal shield around the OM-CP-HITEMP140-PT and screw it back together. The device is ready to be deployed. The OM-CP-HITEMP140-TSK can be completely submerged and is built for applications that require extreme temperature monitoring. These two devices can be started and stopped directly from a computer and their compact design allows them to fit almost anywhere. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e OM-CP-HITEMP140-PT-TSK\u003cbr\u003e (Thermal Shield)\u003cbr\u003e Operating Environment:\u003c\/b\u003e\u003cbr\u003e -200 to 250ºC (-328 to 482ºF) (time limited) 0 to 100% RH\u003cbr\u003e \u003cb\u003eEnclosure Material:\u003c\/b\u003e PTFE\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 110 H x 51 mm dia. (4.3 x 2.0')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 274 g (9.7 oz) not including data logger \u003cbr\u003e\u003cbr\u003e \u003cb\u003eOM-CP-HITEMP140-PT\u003cbr\u003e (Without Thermal Shield)\u003cbr\u003e Temperature Sensor:\u003c\/b\u003e 100Ω Platinum RTD\u003cbr\u003e \u003cb\u003eProbe Measurement Range:\u003c\/b\u003e -200 to 260ºC (-328 to 500ºF)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.01ºC (0.02ºF)\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±0.1ºC (±0.18ºF); 20 to 140ºC (68 to 284ºF)\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e Software programmable immediate start or delay start \u003cbr\u003eup to eighteen months in advance.\u003cbr\u003e \u003cb\u003eStop Modes:\u003c\/b\u003e Manual through software timed (specific data and time)\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e May be used with PC to monitor and record data in real time\u003cbr\u003e \u003cb\u003ePassword Protection: \u003c\/b\u003eAn optional password may be programmed into the device \u003cbr\u003eto restrict access to configuration options, Data may be read out with the password,\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 32,700 readings\u003cbr\u003e \u003cb\u003eWrap Around:\u003c\/b\u003e Yes\u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e One second up to once every 24 hours\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e 3.6V hightemperature lithium battery (included); user replaceable\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 1 year typical [1 minute reading rate at 25ºC (77ºF)]\u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e Digital calibration through software\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Automatically recorded within device\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped ºC, ºF, K, ºR\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±1 minute\/month at 20 to 30ºC (68 to 86ºF)\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e OM-CP-IFC400 docking station required; 125,000 baud\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows® XP SP3\/Vista\/7 and 8 (32- and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 140ºC (-40 to 284°F), 0 to 100% RH\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 120 g (4.2 oz)\u003cbr\u003e \u003cb\u003eMaterial:\u003c\/b\u003e 316 Stainless Steel\u003cbr\u003e \u003cb\u003eDimensions:\u003cbr\u003e   Body:\u003c\/b\u003e 48 x 25 mm dia. (1.9 x 0.97')\u003cbr\u003e   \u003cb\u003eProbe Tip (OM-CP-HITEMP140-PT-1):\u003c\/b\u003e 3.2 OD x 42 mm L (0.125 x 1.5')\u003cbr\u003e   \u003cb\u003eProbe Tip (OM-CP-HITEMP140-PT-5):\u003c\/b\u003e 3.2 OD x 121 mm L (0.125 x 4.8') with 4.8 OD x 25 mm L handle (0.188 x 1')\u003cbr\u003e   \u003cb\u003eFlexible Probe Portion:\u003c\/b\u003e 559 x 1.6 mm OD dia.(22 x 0.062') \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817403654439,"sku":"OM-CP-HITEMP140-PT-Series","price":1344.84,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817403687207,"sku":"OM-CP-HITEMP140-PT-Series","price":1344.84,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-hitemp140-pt_l_46q4uckqdmtxspf9.jpg?v=1741316330"},{"product_id":"wireless-temperature-and-humidity-data-logger-with-display","title":"Wireless Temperature and Humidity Data Logger with Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-RFRHTEMP2000A is a wireless temperature and humidity data logger with digital display. The OM-CP-RFRHTEMP2000A is ideal for both industrial or laboratory applications including supply chain storage facilities, incubator monitoring and HVAC studies. Designed with external humidity and RTD based temperature sensors, the device provides a fast response time for both parameters. For customer convenience, functions include starting, stopping and downloading from the device wirelessly using the OM-CP-RFC1000-EXT wireless transceiver. This allows customers to quickly access data and spend less time maintaining the device. Data can be provided in real time back to a central PC, or the device may be downloaded at periodic intervals. The digital display provides the current reading for both the humidity and temperature channels with minimum, maximum and average statistics accessible for a quick snapshot of the logged data. The OM-CP-RFRHTEMP2000A features user programmable alarm settings for both temperature and humidity parameters. An audible buzzer and LED alarm indicator notifies users when the temperatureor humidity is above or below the threshold set in the alarm. Email and text alarms can also be configured and sent from within the software, allowing users to be notified almost anywhere. The OM-CP-RFRHTEMP2000A can be used as a single, wireless data logging system, or it can be expanded to a large scale system, which can include hundreds of data loggers measuring a number of areas (additional wireless data loggers and transceivers may be required). Data retrieval is simple. Plug the device into an available USB port and our easy-to-use software does the rest. The software converts a PC into a real-time strip chart recorder. The data logger software is a powerful, analytic tool. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation and more.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817403916583,"sku":"OM-CP-RFRHTEMP2000A-Logger","price":858.1,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817403949351,"sku":"OM-CP-RFRHTEMP2000A-Logger","price":858.1,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-rfrhtemp2000a_l_mhvcnggcxq55gyo9.jpg?v=1741316353"},{"product_id":"2-channel-rtd-thermometer-with-optional-datalogging-software","title":"2 Channel RTD Thermometer with Optional Datalogging Software","description":"\u003cp\u003eThe 2‑Channel RTD Thermometer is designed for precise temperature monitoring at two separate sites simultaneously. With RTD inputs, it ensures high accuracy and stability over time. The optional datalogging software allows recording, visualization, and export of temperature data for analysis, compliance, or maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eDual PT100 RTD inputs (3 or 4 wire)\u003c\/p\u003e\n\n\u003cp\u003eHigh accuracy with 0.1°C resolution\u003c\/p\u003e\n\n\u003cp\u003eOptional USB datalogging software for real‑time data recording\u003c\/p\u003e\n\n\u003cp\u003eWide temperature range\u003c\/p\u003e\n\n\u003cp\u003eRobust build for industrial environments\u003c\/p\u003e\n\n\u003cp\u003eDimensions: 160mm(H) x 83mm(W) x 38mm(D)\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817404178727,"sku":"HH804-805","price":469.21,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817404211495,"sku":"HH804-805","price":469.21,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/hh804_805_l_rppjrqr4ftfdvkkv.jpg?v=1741316375"},{"product_id":"2-channel-7-thermocouple-types-wireless-and-usb-datalogger","title":"2 Channel 7 Thermocouple Types Wireless and USB Datalogger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e  \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The HH806 represents the top ofthe line in the HH800 series ofhandheld thermometers. All of theHH806 versions feature exceptional0.05% basic accuracy and include atriple display as well as data loggingcapabilities. The HH806U andHH806W can both store up to 128samples on demand, at the press ofa button and up to 1,024 in datalogging mode, at a user specifiedlogging interval. The HH806AU andHH806AW expand the data loggingcapabilities further and allowstorage of up to 256 samples ondemand and up to 16,000 in datalogging mode. All versions of theHH806 feature three easy to readdisplays. Two 41\/2 digit displays areselectable for T1 or T2 and the third6 digit display can be used forT1-T2 or to show the current dateand time. Windows software isavailable for all models and includedwith the HH806AW. Software is compatible with Windows 10.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eMeasurement Range:\u003c\/b\u003e\u003cbr\u003e    \u003cb\u003eType K:\u003c\/b\u003e -200 to 1372°C (-328 to 2501°F)\u003cbr\u003e    \u003cb\u003eType J:\u003c\/b\u003e -210 to 1200°C (-346 to 2192°F)\u003cbr\u003e    \u003cb\u003eType T:\u003c\/b\u003e -200 to 400°C (-328 to 752°F)\u003cbr\u003e    \u003cb\u003eType E:\u003c\/b\u003e -220 to 1000°C (-364 to 1832°F)\u003cbr\u003e    \u003cb\u003eType R:\u003c\/b\u003e 0 to 1767°C (32 to 3212°F)\u003cbr\u003e    \u003cb\u003eType S:\u003c\/b\u003e 0 to 1767°C (32 to 3212°F)\u003cbr\u003e    \u003cb\u003eType N:\u003c\/b\u003e -50 to 1300°C (-58 to 2372°F)\u003cbr\u003e\u003cb\u003eAccuracy:\u003c\/b\u003e Stated accuracy at 23°C ±5°C, \u0026lt;75% RH\u003cbr\u003e\u003cb\u003eType K\/J\/T\/E:\u003c\/b\u003e ±(0.05% rdg + 0.3°C) -50 to 1372°C ±(0.05% rdg + 0.7°C) -50 to -210°C ±(0.05% rdg + 0.6°F) -58 to 2501°F ±(0.05% rdg + 1.4°F) -58 to -346°F\u003cbr\u003e\u003cb\u003eType N:\u003c\/b\u003e ±(0.05% rdg + 0.8°C) -50 to 0°C ±(0.05% rdg + 0.4°C) 0 to 1300°C ±(0.05% rdg + 1.6°F) -58 to 32°F ±(0.05% rdg + 0.8°F) 32 to 2372°F\u003cbr\u003e\u003cb\u003eType R\/S:\u003c\/b\u003e ±(0.05% rdg + 2 0°C to 1767°C ±(0.05% rdg + 4 32°F to 3212°F\u003cbr\u003e\u003cb\u003eOperating Environment:\u003c\/b\u003e 0 to 50°C (32 to 122°F) at \u0026lt;70% RH\u003cbr\u003e\u003cb\u003eStorage Temperature:\u003c\/b\u003e -20 to 60°C (-4 to 140°F), 0 to 80% RH with battery removed\u003cbr\u003e\u003cb\u003eBattery:\u003c\/b\u003e 4 x 1.5V \"AAA\" (included)\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e 160 H x 83 W x 38 mm D (6.3 x 3.3 x 1.5\")\u003cbr\u003e\u003cb\u003eWireless Features:\u003c\/b\u003e\u003cbr\u003e    \u003cb\u003eFrequency Range:\u003c\/b\u003e USA 900 MHz European 868.0 to 868.6 MHz\u003cbr\u003e    \u003cb\u003eCurrent Consumption:\u003c\/b\u003e 5 to 20 mA\u003cbr\u003e    \u003cb\u003eApproximate Range:\u003c\/b\u003e 25 m (75') \u003c\/span\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817404539175,"sku":"HH806","price":987.52,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817404571943,"sku":"HH806","price":987.52,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/hh806_l_mjtormzmghsdw8ym.jpg?v=1741316400"},{"product_id":"temperature-humidity-alarm-with-logging-capability","title":"Temperature Humidity Alarm with Logging Capability","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   The OM-THA2-U is a multi-function unit that monitors temperature, relative humidity and dew point. The OM-THA2-U records data and generates an alarm for any out-of-range conditions. It consists of a base unit with an easy-to-read display and a 4.6 m (15') remote sensor probe.\u003cbr\u003e\u003cbr\u003e The alarm function monitors temperature, relative humidity and dew point once every second. If any of the readings reach an alarm threshold, the unit generates an alarm by turning on a beeper and a dry relay contact. The relay can be connected to a telephone dialer, light or bell. The delayed alarm feature can reduce false alarms by ignoring short duration alarm conditions. The unit will also generate an alarm on probe failure.\u003cbr\u003e\u003cbr\u003e The logger function records the data into an internal non-volatile memory at a user specified interval. The recording is performed continuously after the unit is turned on. No computer set-up is necessary to start logging, and all logging settings can be viewed or changed through the front panel functions. When the internal memory becomes full the recording rolls over, overwriting the oldest recorded data. Review logged data on a computer using the included Windows software while continuously recording new data.\u003cbr\u003e\u003cbr\u003e All the operating settings of the OM-THA2-U can be changed from the front panel without the need for a computer. The two-line display provides an easy-to-read means of viewing or changing settings. \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817404834087,"sku":"OM-THA2-U-Alarm","price":1161.74,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817404866855,"sku":"OM-THA2-U-Alarm","price":1161.74,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-tha2-u_l_tgvgrfyoqd2e5wmb.jpg?v=1741316422"},{"product_id":"micro-relative-humidity-and-temperature-data-logger","title":"Micro Relative Humidity \u0026 Temperature Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-MICRORHTEMP is a miniature, battery-powered, stand-alone temperature and humidity data logger. This device combines the latest in low-power technology with Windows based software to provide a next-generation temperature and humidity recorder. The data logger records 16,383 humidity and 16,383 temperature measurements simultaneously. \u003cbr\u003e\u003cbr\u003e The OM-CP-MICRORHTEMP is a major leap in both size and performance. Its real-time clock enables all data to be time and date stamped. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. Its small size allows the device to fit almost anywhere. \u003cbr\u003e\u003cbr\u003e Data retrieval is simple. Plug it into an available COM port and the easy-to-use Windows software does the rest. The OM-CP-MICRORHTEMP requires minimal effort to configure and control. The software used to operate the OM-CP-MICRO-RHTEMP requires no programming skills and enables users to effortlessly select reading rate and device ID. Data collection can start moments after connecting the hardware. A simple plug-in connection is all that is required to connect the OM-CP-MICRORHTEMP to a PC. Data can be printed in graphical and tabular format or exported to a text or Microsoft Excel file. \u003cbr\u003e\u003cbr\u003e \u003cdiv class=\"tableWrapPP\"\u003e\u003ctable width=\"620\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e \u003ctbody\u003e\n\u003ctr\u003e \u003ctd valign=\"top\"\u003e \u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e \u003cb\u003eTemperature Sensor:\u003c\/b\u003e Semiconductor\u003cbr\u003e \u003cb\u003eTemperature Accuracy: \u003c\/b\u003e0.5°C\u003cbr\u003e \u003cb\u003eTemperature Resolution: \u003c\/b\u003e0.1°C\u003cbr\u003e \u003cb\u003eTemperature Range:\u003c\/b\u003e 0 to 50°C \u003cbr\u003e(32 to 122°F)\u003cbr\u003e \u003cb\u003eHumidity Sensor:\u003c\/b\u003e Semiconductor\u003cbr\u003e \u003cb\u003eHumidity Accuracy:\u003c\/b\u003e 3% RH\u003cbr\u003e \u003cb\u003eHumidity Resolution:\u003c\/b\u003e 0.95% RH\u003cbr\u003e \u003cb\u003eHumidity Range:\u003c\/b\u003e 0 to 95% RH \u003cbr\u003enon-condensing\u003cbr\u003e \u003cb\u003e Calibrated Accuracy:\u003c\/b\u003e ±3% RH \u003cbr\u003e (±2% RH typical @ 25°C)\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e 90% change in 60 seconds in slow moving air\u003cbr\u003e \u003cb\u003eAccuracy Range:\u003c\/b\u003e 10 to 80% RH, 10 to 40°C \u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e Digital calibration\u003cbr\u003e is available through software\u003cbr\u003e \u003cb\u003eRecording Interval:\u003c\/b\u003e 30\/minute to 1\/day \u003cbr\u003eselectable through software\u003cbr\u003e \u003cb\u003eStart Time:\u003c\/b\u003e Software programmable start time \u003cbr\u003eand date (up to six months in advance)\u003cbr\u003e \u003cb\u003eAlarm:\u003c\/b\u003e programmable high and low limits\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e Device may be used with PC to monitor and record data in real time\u003cbr\u003e \u003cb\u003eActivity Indicator:\u003c\/b\u003e Green LED blinks \u003cbr\u003eevery 15 seconds to indicate\u003cbr\u003e device has been started\u003cbr\u003e \u003c\/td\u003e \u003ctd width=\"20\"\u003e  \u003c\/td\u003e \u003ctd valign=\"top\"\u003e\n\u003cbr\u003e\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 2 miniature 3 V lithium batteries \u003cbr\u003e (loggers with serial #’s lower than M30000) or two 1.55 V silver oxide coin cells (loggers\u003cbr\u003e with serial #’s M30000 and higher) included \u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 1 year typical \u003cbr\u003e (15-minute reading rate, 25°C \u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e +1 minute per month at 20°C\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped, \u003cbr\u003e °C, °F, °K, °R, %RH, dew point, vapor concentration\u003cbr\u003e \u003cb\u003eTemperature Alarm:\u003c\/b\u003e Programmable temperature alarm with high and low limits selectable in software; \u003cbr\u003ewhen logged data reaches or exceeds either limit,\u003cbr\u003e the red LED blinks every three seconds\u003cbr\u003e \u003cb\u003eWeight: \u003c\/b\u003e30 g (1 oz.)\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e PC serial or USB \u003cbr\u003e (interface cable required, 38,400 baud\u003cbr\u003e \u003cb\u003eSoftware: \u003c\/b\u003eXP SP3\/Vista and 7 (32 and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e 0 to 50°C \u003cbr\u003e (32 to 122°F) 5 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 15 mm dia x 38 mmL \u003cbr\u003e (0.60' x 1.5')\u003cbr\u003e \u003cb\u003eMaterial:\u003c\/b\u003e Stainless steel\u003cbr\u003e \u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817405030695,"sku":"OM-CP-MICRORHTEMP-Logger","price":803.1,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817405063463,"sku":"OM-CP-MICRORHTEMP-Logger","price":803.1,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-microrhtemp_l_l7akudlixzoy107s.jpg?v=1741316445"},{"product_id":"pressure-humidity-and-temperature-data-logger","title":"Pressure, Humidity and Temperature Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-PRHTEMP101A is a low cost, state-of-theart pressure, relative humidity and temperature data logger, specifically designed to be compact and portable for use in a variety of applications such as museum and archive preservation, shipping and transportation, warehouse monitoring, HVAC, clean rooms, clinical laboratories and altitude validation and studies.\u003cbr\u003e\u003cbr\u003e The OM-CP-PRHTEMP101A offers a 10-year battery life, 1 second reading rate, multiple start\/stop functions, ultra-high speed download capability, optional memory wrap, battery life indicator, optional password protection, programmable high-low alarms and more.\u003cbr\u003e\u003cbr\u003e Using the software, starting, stopping and downloading from the OM-CP-PRHTEMP101A is simple and easy. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, °R, K, for the temperature channel, %RH, mg\/mL and dew point for the humidity channel, and mbar, PSI, inHg, mmHg, atm, Torr, Pa, m, kPa, MPa for the pressure channel.\u003cbr\u003e\u003cbr\u003e The OM-CP-PRHTEMP101A is a major leap forward in both size and performance, Its real-time clock ensures that all data is time and date stamped. The storage medium is non-volatile memory, providing maximum data security even if the battery becomes discharged.\u003cbr\u003e\u003cbr\u003e Data retrieval is simple. Simply connect the data logger to an available USB port and the easy to use Windows software does the rest. The software converts your PC into a real-time strip chart recorder. Data can be printed in tabular format and can also be exported to a text or Microsoft Excel file for further calculations.\u003cbr\u003e\u003cbr\u003e The OM-CP-PRHTEMP101A was designed with our customers in mind. There are free firmware upgrades for the life of the product so that data loggers already deployed in the field can grow with new technological developments. Units do not need to be returned to the factory for upgrades, this can be done automatically from any PC.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003ePressure\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSensor:\u003c\/b\u003e Piezoresistive\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 250 to 1300 mbar\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.02 mbar\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e 10 mbar\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHumidity\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSensor:\u003c\/b\u003e Capacitive Polymer\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 0 to 95% RH\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.1 %RH\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e 3% RH\u003cbr\u003e\u003cbr\u003e \u003cb\u003eTemperature\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSensor:\u003c\/b\u003e Precision RTD element\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e -40 to 80°C (-40 to 176°F)\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.01°C (0.018°F)\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±0.5°C (0.9°F)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e 1 reading every second up to 1 reading every 24 hours.\u003cbr\u003e \u003cb\u003eMemory\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eReadings Per Channel:\u003c\/b\u003e 688,128\u003cbr\u003e \u003cb\u003eReadings (Manual or Trigger Mode):\u003c\/b\u003e 412,876\u003cbr\u003e \u003cb\u003eMemory Wrap Around:\u003c\/b\u003e Yes (software selectable)\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e\u003cbr\u003e     • Immediate start\u003cbr\u003e     • Delay start up to 18 months\u003cbr\u003e     • Multiple pushbutton start\/stop\u003cbr\u003e \u003cb\u003eStop Modes:\u003c\/b\u003e\u003cbr\u003e     • Manual through software\u003cbr\u003e     • Timed (specific date and time)\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e The device may be used with a PC to monitor and record data in real time.\u003cbr\u003e \u003cb\u003eAlarm:\u003c\/b\u003e Programmable high and low limits; alarm is activated when recording environment reaches or exceeds set limits (pressure channel only).\u003cbr\u003e \u003cb\u003eLED Functionality\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eGreen LED blinks:\u003c\/b\u003e\u003cbr\u003e     • 10 second rate to indicate logging\u003cbr\u003e     • 15 second rate to indicate delay start mode\/Standby (Waiting to start)\u003cbr\u003e \u003cb\u003eRed LED blinks:\u003c\/b\u003e\u003cbr\u003e     • 10 second rate to indicate low battery and\/or full memory\u003cbr\u003e     • 1 second to indicate alarm condition met\u003cbr\u003e \u003cb\u003ePassword Protection:\u003c\/b\u003e An optional password may be programmed into the device to restrict access to configuration options. Data may be read without the password.\u003cbr\u003e \u003cb\u003eEngineering Units:\u003c\/b\u003e Native measurement units can be changed to display measurement units of another type.\u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e Digital calibration through software\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Automatically recorded within device\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e 3.6V lithium battery included; user replaceable\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 10 years typical at a 15 minute reading rate\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped °C, °F, °R, K, %RH, mg\/mL, Dew Point, mbar, PSI, inHg, mmHg, atm, Torr, Pa, kPa, m, MPa units specified through software.\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±1 minute\/month @ 25°C\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e USB (interface cable required); 115,200 baud\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows XP SP3\/Vista\/7 and 8 (32-bit and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 80°C (-40 to 176°F), 0 to 95 %RH non-condensing, 0.002 to 100 psia\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 36 L x 56 W x 16 mm D (1.4 x 2.2 x 0.6')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 24 g (0.8 oz)\u003cbr\u003e \u003cb\u003eMaterials:\u003c\/b\u003e ABS Plastic \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817405260071,"sku":"OM-CP-PRHTEMP101A-Logger","price":666.38,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817405292839,"sku":"OM-CP-PRHTEMP101A-Logger","price":666.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-prhtemp101a_l_dv0sw7culrrusfir.jpg?v=1741316468"},{"product_id":"thermistor-probe-temperature-data-logger-with-lcd-display","title":"Thermistor Probe Temperature Data Logger with LCD Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-EL-USB-TP-LCD standalone data logger measures and stores up to 32,510 temperature readings from the supplied thermistor probe which is attached via the socket at the base of the unit. The user can easily set-up the logging rate and start-time, and download the stored data by plugging the data logger into a PC’s USB port and running the included Windows software. Data can then be graphed, printed and exported to other applications.\u003cbr\u003e\u003cbr\u003e The data logger features an LCD display and pushbutton which allows the user to cycle through the most recent, highest and lowest stored temperature readings. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 6 months. The OM-EL-USB-TP-LCD is suitable for a wide variety of applications including high and low temperature monitoring, transportation, food processing, building and site monitoring and HVAC.\u003cbr\u003e\u003cbr\u003e Windows software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows XP, Vista, 7 and 8. The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows for the following parameters to be configured: logger name, temperature units (°C, °F), logging rate (1 sec, 10 sec, 30 sec, 1 min, 5 min, 30 min, 1 hr, 6 hr, 12 hr), high and low alarms, start mode (immediate, delayed and push-to-start logging), display mode (display off, on for 30 seconds after button press, or permanently on) and data rollover (allows unlimited logging periods by overwriting the oldest data when the memory is full).\u003cbr\u003e\u003cbr\u003e \u003cb\u003eThermistor Probe\u003c\/b\u003e\u003cbr\u003e The probe supplied with the OM-EL-USB-TP-LCD uses a precision thermistor to sense the temperature. The probe length may be extended by the use of a suitable extension cable (use twisted pair with high quality 3.5 mm jack socket\/plugs for best results).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProbe Temperature Measurement Range:\u003c\/b\u003e -40 to 125°C (-40 to 257°F)\u003cbr\u003e \u003cb\u003eResolution (Internal and Displayed):\u003c\/b\u003e 0.5°C (1.0°F)\u003cbr\u003e \u003cb\u003eAccuracy (Data Logger Error @ 25°C):\u003c\/b\u003e ±0.1°C (±0.2°F) typical (does not include thermistor probe error)\u003cbr\u003e \u003cb\u003eAccuracy (Thermistor Probe):\u003c\/b\u003e See thermistor probe accuracy charts on PDF\u003cbr\u003e \u003cb\u003eOperating Temperature Range (Data Logger):\u003c\/b\u003e -10 to 40°C (-14 to 104°F)\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 32,510 readings\u003cbr\u003e \u003cb\u003eMemory Wrap Around (Rollover):\u003c\/b\u003e Yes (software selectable)\u003cbr\u003e \u003cb\u003eLogging Interval:\u003c\/b\u003e 1 sec, 10 sec, 30 sec, 1 min, 5 min, 30 min, 1 hr, 6 hr, 12 hr\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows XP\/Vista\/7 and 8 (32- and 64-bit)\u003cbr\u003e \u003cb\u003eAlarm Thresholds:\u003c\/b\u003e High\/low alarm thresholds for temperature (software selectable)\u003cbr\u003e \u003cb\u003eStart Mode:\u003c\/b\u003e Immediate, delayed and push-to-start logging (software selectable)\u003cbr\u003e \u003cb\u003eStatus Indicators (LEDs):\u003c\/b\u003e Red and green LEDs. The first LED flashes red to indicate that the OM-EL-USB-TP-LCD is in an alarm condition (logged temperature has exceeded a high or low alarm level). The second LED flashes green to indicate that the OM-EL-USB-TP-LCD is logging normally and is not in an alarm condition.\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 1\/2 “AA”, 3.6V lithium battery (included)\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 6 months typical at 25°C (77°F) (depends on sample rate, ambient temperature and LCD use)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eData Logger:\u003c\/b\u003e See dimensional drawing on PDF\u003cbr\u003e \u003cb\u003eStandard Thermistor Probe\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eCable:\u003c\/b\u003e 1 m (3')\u003cbr\u003e     \u003cb\u003eProbe Tip:\u003c\/b\u003e Stainless steel, 25 L x 5 mm dia (1 x 3\/16')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 45 g (1.6 oz) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817405489447,"sku":"OM-EL-USB-TP-LCD-Series","price":336.53,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817405522215,"sku":"OM-EL-USB-TP-LCD-Series","price":336.53,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-el-usb-tp-lcd_l_bs4pgp1vmumj0jrr.jpg?v=1741316492"},{"product_id":"thermocouple-temperature-data-logger-with-lcd-display","title":"Thermocouple Temperature Data Logger with LCD Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-TCTEMP2000 is a battery powered thermocouple temperature data logger with an LCD display. This data logger has an internal temperature sensor and one external input for J, K, T, E, R, S, B, and N type thermocouples. The 8-button keypad and large LCD provide convenient access to current data and recorder setup. Additionally, memory and battery levels, external power status, and sampling and recording status are shown on the LCD. \u003cbr\u003e\u003cbr\u003e Available on-screen data includes: statistics (min, max, average) recording status (start, stop and recording rate) display options (units, text size) and calibration information (date calibrated, date for recalibration). Statistics can be cleared at any time during logging. With 131,071 readings, the OM-CP-TCTEMP2000 has one of the largest memory capacities of any similar data recorder on the market. The non-volatile memory will retain recorded data, even if AC and battery power are lost. The OM-CP-TCTEMP2000 runs on a 9 V battery with a typical battery life of 1 year at a 1 min reading rate with the display off. With continuous LCD and no backlight usage, the average battery life is 30 days. For power savings, both the LCD and backlight have configurable auto-off options. \u003cbr\u003e\u003cbr\u003e Those wanting to keep the LCD display and backlight continuously active need only to connect the unit to an AC power supply, keeping the 9 V battery connected as a back-up. NIST traceable calibration is available for users needing to meet regulatory requirements. Creating permanent records, performing data calculations, and the graphing of data is quick and easy: Simply connect the interface cable to an availableUSB or serial port and, with a few clicks of the mouse, data is downloaded and ready for review or export to Excel.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817405718823,"sku":"OM-CP-TCTEMP2000-Logger","price":1479.11,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817405751591,"sku":"OM-CP-TCTEMP2000-Logger","price":1479.11,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-tctemp2000_l_temaxmohxadgepz9.jpg?v=1741316515"},{"product_id":"single-use-usb-temperature-data-loggers-for-audit-reports","title":"Single Use USB Temperature Data Loggers for Audit Reports.","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The New OM-21A PDF data loggers are ideal for monitoring the temperature in transport, storage, and testing process. Easy to do the recording by pressing a button to start and stop. True Plug and Play Experience by plugging into a USB slot on any computer to get the PDF report directly without any software and driver installation requirement. This data logger is used mainly to monitor and verify temperature sensitive goods, equipment or areas.\u003cbr\u003e\u003cbr\u003e Applications: Cold Chain, Refrigeration, Transportation, Warehouse, HVAC, Food and Pharmaceutical.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecification\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eUse Type:\u003c\/b\u003e Single-use\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e ±0.5ºC\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.1ºC\u003cbr\u003e \u003cb\u003eMeasuring Range:\u003c\/b\u003e -30 to 70ºC\u003cbr\u003e \u003cb\u003eData Storage Capacity:\u003c\/b\u003e 8640 Data Points\u003cbr\u003e \u003cb\u003eSample Interval:\u003c\/b\u003e OM-21A-R1-10PK Default as 10 mins OM-21A-P-10PK User Configurable between 10 sec to 18 hours\u003cbr\u003e \u003cb\u003eRun Days:\u003c\/b\u003e 1 to 360 days\u003cbr\u003e \u003cb\u003eHigh and Low Alarm:\u003c\/b\u003e OM-21A-R1-10PK Default as Low Limit 2ºC  \u0026amp; High Limit 8ºC OM-21A-P-10PK User Configurable\u003cbr\u003e \u003cb\u003eAlarm Delay:\u003c\/b\u003e OM-21A-R1-10PK Default as 10 mins OM-21A-P-10PK User configurable between 0 to 960 min\u003cbr\u003e \u003cb\u003eAlarm Type:\u003c\/b\u003e Single type\u003cbr\u003e \u003cb\u003eStart Delay:\u003c\/b\u003e OM-21A-R1-10PK Default as 0 mins OM-21A-P-10PK User configurable between 0 to 254 min\u003cbr\u003e \u003cb\u003eStart Mode:\u003c\/b\u003e By button\u003cbr\u003e \u003cb\u003eStop Mode:\u003c\/b\u003e By button Memory full When Plug into USB\u003cbr\u003e \u003cb\u003eOperation Environment:\u003c\/b\u003e -30 to 70ºC\u003cbr\u003e \u003cb\u003eStorage Environment:\u003c\/b\u003e -30 to 70ºC\u003cbr\u003e \u003cb\u003eSize\/Weight\/Case Material:\u003c\/b\u003e 62 mm x 27 mm x 4 mm\/10g\u003cbr\u003e \u003cb\u003eProtection Class:\u003c\/b\u003e IP67 with Protection Bag\u003cbr\u003e \u003cb\u003eStandards\/Certificates:\u003c\/b\u003e CE, ROHS, EN12830\u003cbr\u003e \u003cb\u003eCommunication Interface:\u003c\/b\u003e Build-in USB 2.0\u003cbr\u003e \u003cb\u003ePower Supply:\u003c\/b\u003e Battery CR2032\u003cbr\u003e  \u003cb\u003eShelf Life:\u003c\/b\u003e 2 Year\u003cbr\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817405980967,"sku":"OM-21A-Series","price":508.88,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817406013735,"sku":"OM-21A-Series","price":508.88,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-21a_1200_0agdfwkuoxziobaf.jpg?v=1741316538"},{"product_id":"submersible-high-temperature-and-pressure-data-logger","title":"Submersible High Temperature and Pressure Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-PRTEMP140 is a high temperature and pressure data logger all in one, created specifically for use in autoclave validation, mapping studies and pressurized processes. Featuring the familiar body style of the OM-CP-HITEMP140 Series of data loggers and made of rugged stainless steel, this dual purpose device is less than 64 mm (2.5') in length, allowing it to fit discretely inside small spaces.\u003cbr\u003e\u003cbr\u003e The OM-CP-PRTEMP140 data logger downloads temperature and pressure data simultaneously and displays the combined results in a single graph, simplifying data collection and analysis and eliminating unnecessary steps for the user. This data logger is able to measure and record temperatures from -20 to 140°C (-4 to 284°F), and pressure from 0 bar to 5 bar, accommodating a wide range of applications even in the harshest conditions. The memory capacity on the OM-CP-PRTEMP140 stores up to 32,700 time and date stamped readings and will retain data even if the battery becomes discharged.\u003cbr\u003e\u003cbr\u003e The OM-CP-PRTEMP140 utilizes the latest software, making the entire process from starting the device to analyzing data, efficient and easy for the user. Downloaded data can be viewed in various formats including graphic and tabular and can also be exported to Excel® for further analysis and calculations.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003ePressure\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSensor:\u003c\/b\u003e Strain gauge\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 0 to 5 bar\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.0001 bar\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±0.03 bar (20 to 140°C)\u003cbr\u003e \u003cb\u003eTemperature\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSensor:\u003c\/b\u003e Resistance temperature detector (RTD)\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e -20 to 140°C (-4 to 284°F)\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.01°C\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±0.1°C (20 to 140°C)\u003cbr\u003e \u003cb\u003eGeneral\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Immediate start\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Delay start up to 18 months in advance\u003cbr\u003e \u003cb\u003eStop Modes:\u003c\/b\u003e Manual or timed (specific date and time)\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e May be used with PC to monitor and record data in real time\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 32,767 readings\u003cbr\u003e \u003cb\u003ePassword Protection:\u003c\/b\u003e An optional password may be programmed into the device to restrict access to configuration options. Data may be read without the password\u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e 1 reading every second up to 1 reading every 24 hours\u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e Digital calibration through software\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Automatically recorded within device\u003cbr\u003e \u003cb\u003eMemory Wrap:\u003c\/b\u003e Yes\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e °C, °F, °R, K, bar, mbar, PSI, inHg, mmHg, atm, Torr, Pa, kPa, MPa\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 2 years typical (1 minute reading rate)\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e 3.6V high-temperature lithium battery included; user replaceable\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±1 min\/month @ 25°C\u003cbr\u003e \u003cb\u003eExtended Operation:\u003c\/b\u003e ±20 mins\/month at 140°C\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows® XP SP3\/Vista\/7 and 8 (32- and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -20 to 140°C (-4 to 284°F), 0 to 100% RH, 0.002 to 100 PSIA\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-CP-PRTEMP140-LVL (Flush Top):\u003c\/b\u003e 50.2 L x 24.6 mm dia (1.98 x 0.97')\u003cbr\u003e     \u003cb\u003eOM-CP-PRTEMP140-NPT (NPT Top):\u003c\/b\u003e 58.2 L x 24.6 mm dia (2.3 x 0.97')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-CP-PRTEMP140-LVL (Flush Top):\u003c\/b\u003e 90 g (3.2 oz)\u003cbr\u003e     \u003cb\u003eOM-CP-PRTEMP140-NPT (NPT Top):\u003c\/b\u003e 100 g (3.5 oz)\u003cbr\u003e \u003cb\u003eMaterial:\u003c\/b\u003e 316 stainless steel\u003cbr\u003e \u003cb\u003eIP Rating:\u003c\/b\u003e IP68 \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817406210343,"sku":"OM-CP-PRTEMP140-Series","price":3441.98,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817406243111,"sku":"OM-CP-PRTEMP140-Series","price":3441.98,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-prtemp140_l_jspjpdva58hc7lrc.jpg?v=1741316561"},{"product_id":"2-channel-7-thermocouple-types-datalogger-water-splash-proof","title":"2 Channel 7 Thermocouple Types Datalogger Water\/Splash Proof","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\n\u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\"\u003e The OMEGA™ HH500RA is a low cost, feature-packed, portable, digital thermometer that measures K, J, R, S, T, E and N thermocouples. The unit has datalogging capacity in the save mode of 128 samples with real-time data and in the datalogging mode of 16 sets, with a maximum data capacity of 1024 records. Easy to use set-up instructions allow the user to measure a broad range of T\/Cs, MAX\/MIN, AVG, REL, Hold Function, T1\/T2.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e \u003cbr\u003e\u003cb\u003eTemperature Range:\u003c\/b\u003e \u003cbr\u003e    \u003cb\u003eK Type:\u003c\/b\u003e (0.1°, 1° for above 2000°F) -200 to 1372°C (-328 to 2501°F) \u003cbr\u003e    \u003cb\u003eJ Type:\u003c\/b\u003e (0.1°, 1° for above 2000°F) -210 to 1200°C (-346 to 2192°F) \u003cbr\u003e    \u003cb\u003eT Type:\u003c\/b\u003e (0.1°) -200 to 400°C (-328 to 752°F) \u003cbr\u003e    \u003cb\u003eE Type:\u003c\/b\u003e (0.1°) -210 to 1000°C (-346 to 1832°F) \u003cbr\u003e    \u003cb\u003eR Type:\u003c\/b\u003e (1°) 0 to 1767°C (32 to 3212°F) \u003cbr\u003e    \u003cb\u003eS Type:\u003c\/b\u003e (1°) 0 to 1767°C (32 to 3212°F) \u003cbr\u003e    \u003cb\u003eN Type:\u003c\/b\u003e (0.1°, 1° for above 2000°F) -50 to 1300°C (-58 to 2372°F) \u003cbr\u003e\u003cfont size=\"1\"\u003eAccording to temperature standard ITS-90\u003c\/font\u003e \u003cbr\u003e\u003cb\u003eAccuracy:\u003c\/b\u003e \u003cbr\u003e    \u003cb\u003eK\/J\/T\/E Type:\u003c\/b\u003e \u003cbr\u003e    ±(0.05% rdg + 0.3°C) on -50 to 1370°C \u003cbr\u003e    ±(0.05% rdg + 0.7°C) on -50 to -210°C \u003cbr\u003e    ±(0.05% rdg + 0.6°F) on -58 to 2501°F \u003cbr\u003e    ±(0.05% rdg + 1.4°F) on -58 to -346°F \u003cbr\u003e    \u003cb\u003eN Type:\u003c\/b\u003e \u003cbr\u003e    ±(0.05% rdg + 0.8°C) on -50 to 0°C \u003cbr\u003e    ±(0.05% rdg + 0.4°C) on 0 to 1300°C \u003cbr\u003e    ±(0.05% rdg + 1.6°F) on -58 to 32°F \u003cbr\u003e    ±(0.05% rdg + 0.8°F) on 32 to 2372°F \u003cbr\u003e    \u003cb\u003eR\/S Type:\u003c\/b\u003e \u003cbr\u003e    ±(0.05% rdg + 2°C) on 0 to 1767°C \u003cbr\u003e    ±(0.05% rdg + 4°F) on 32 to 3212°F \u003cbr\u003e\u003cb\u003eResolution:\u003c\/b\u003e 0.1°C\/1°C (0.1°F\/1°F) \u003cbr\u003e\u003cb\u003ePower:\u003c\/b\u003e 9 V battery (included) \u003cbr\u003e\u003cb\u003eDatalogger Capacity:\u003c\/b\u003e \u003cbr\u003e    \u003cb\u003eSave Data:\u003c\/b\u003e 128 samples with time stamp \u003cbr\u003e    \u003cb\u003eDatalogger:\u003c\/b\u003e 1024 data capacity(interval 1 sec to 23:59:59) \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817406406951,"sku":"HH506A-HH506RA","price":485.0,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817406439719,"sku":"HH506A-HH506RA","price":485.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/hh506a_hh506ra_l_zopuqktqxdf6rzsv.jpg?v=1741316585"},{"product_id":"rechargeable-temperature-data-logger-with-usb-interface","title":"Rechargeable Temperature Data Logger with USB Interface","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-EL-USB-1-RCG data logger measures and stores up to 32,510 temperature readings over a \u003cbr\u003e-20 to 60°C (-4 to 140°F) temperature range. The 316 SS case with polycarbonate window assembly is corrosion, impact and water resistant to NEMA 4X (IP67) standards. The unit is powered by a lithium-ion rechargeable battery which allows logging for up to 1 month. The user can easily set-up the data logger and download the stored data by plugging the module straight into a PC’s USB port and running the easy-to-use Windows software. Software selectable set-up parameters include logging rate (1 sec, \u003cbr\u003e10 sec, 1 min, 5 min, 30 min, 1 hr, 6 hr, 12 hr), start-date\/time, and desired temperature units (ºC or ºF). Data can then be graphed, printed and exported to other applications such as Excel. Correct functioning of the unit is indicated by flashing red and green LEDs. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e Temperature Measurement Range:\u003c\/b\u003e -20 to 60ºC (-4 to 140ºF)\u003cbr\u003e \u003cb\u003eResolution:\u003c\/b\u003e 0.1ºC (0.2ºF)\u003cbr\u003e \u003cb\u003eAccuracy: \u003c\/b\u003e±1.0ºC (±2.0ºF) typical\u003cbr\u003e \u003cb\u003eTemperature Units:\u003c\/b\u003e ºC (ºF) selectable in software\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 32,510 readings\u003cbr\u003e \u003cb\u003eLogging Interval: \u003c\/b\u003e1 sec, 10 sec, 1 min, 5 min, 30 min, 1 hr, 6 hr, 12 hr \u003cbr\u003e(selectable in software)\u003cbr\u003e \u003cb\u003eStart Date\/Time: \u003c\/b\u003eSelectable in software\u003cbr\u003e \u003cb\u003eAlarm Thresholds: \u003c\/b\u003eHigh\/low temperature alarm thresholds selectable in software\u003cbr\u003e \u003cb\u003eStatus Indicators (LEDs):\u003c\/b\u003e Red and green\u003cbr\u003e \u003cb\u003eOperating Temperature Range:\u003c\/b\u003e -20 to 60ºC (-4 to 140ºF)\u003cbr\u003e \u003cb\u003eCharging Temperature Range:\u003c\/b\u003e 10 to 30ºC (50 to 86ºF)\u003cbr\u003e \u003cb\u003eRecharging Time:\u003c\/b\u003e 5 hours max (the data logger must be connected to an active USB port \u003cbr\u003eto recharge the battery)\u003cbr\u003e \u003cb\u003eBattery Life (Rechargeable Lithium-Ion):\u003c\/b\u003e 1 week min (at -20ºC, 1 sec logging interval); \u003cbr\u003e4 weeks max (at 20ºC, 1 min logging interval)\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows 2000\/XP\/Vista\/7 and 8 (32-bit and 64-bit)\u003cbr\u003e \u003cb\u003ePower: \u003c\/b\u003eRechargeable lithium-ion battery (280 mAh)\u003cbr\u003e \u003cb\u003eWeight: \u003c\/b\u003e40 g (1.4 oz)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 92.7 L x 19.8 mm D (3.65 x 0.78') \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817406603559,"sku":"OM-EL-USB-1-RCG-Logger","price":406.43,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817406636327,"sku":"OM-EL-USB-1-RCG-Logger","price":406.43,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-el-usb-1-rcg_l_u6ogh53iglwbc3cx.jpg?v=1741316606"},{"product_id":"1-and-2-channel-bluetooth-with-free-app-thermocouple-datalogger","title":"1 \u0026 2 Channel Bluetooth with Free App Thermocouple Datalogger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e Omega’s first cloud capable digital thermometers HH931T and HH932T offer the easiest data logging functionality available, allowing users to record and store up to 1000 time-stamped measurements accurately. You can store unlimited points when connected via the Bluetooth application. This seamless connectivity allows the user to collect, transmit, and store accurate temperature data for analysis or compliance reporting without any additional or third-party software.\u003cbr\u003e\u003cbr\u003e Real-time statistical data increases user productivity, process efficiency, and product quality. Displayed on-demand, MIN, MAX, AVG, RNG and STDEV (standard deviation) provide critical process information and diagnostics that allows the user to analyze manufacturing processes on the fly and make immediate adjustments for maximum efficiency and quality\u003cbr\u003e\u003cbr\u003e The HH931T single channel and HH932T dual channel meters are compatible with Type K, J, T, E, B, N, R \u0026amp; S thermocouple probes to provide a wide range of temperature measurements from 600 to 1820ºC (1112 to 3308ºF), and they boast a 1000-hour battery life (batteries included). Both meters provide dependable and uninterrupted portable measurement capability without expensive batteries, AC adapters, or chargers.\u003cbr\u003e\u003cbr\u003e The HH931T and HH932T are well suited for a wide variety of industries such as pharmaceutical, food, automotive, aluminum, environmental, chemical, and HVAC. The creative ergonomic design makes these instruments easy-to-hold, read, and clean. Designed for one-handed operation, these tools are comfortable to carry and use for extended periods of time.\u003cbr\u003e\u003cbr\u003e Omega backs these durable instruments with a standard 3-year warranty and a 2-year calibration guarantee to ensure that your instrument is ready to use when you need it.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eBasic Accuracy:\u003c\/b\u003e ±(0.04% |rdg| +0.3°C)\u003cbr\u003e \u003cb\u003eConnector Type:\u003c\/b\u003e Mini-TC Probe Zero Function: Resolution 0.1°C\/°F\/K\u003cbr\u003e \u003cb\u003eDisplay:\u003c\/b\u003e 4 digit auto-resolution (0.1\/1) with backlight and function annunciators\u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e 3\/sec. for readings and TREND indicators\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e 3 “AA” (IEC LR6, ANSI 15) Alkaline\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 1000 hours\u003cbr\u003e \u003cb\u003eStatistics:\u003c\/b\u003e Min, Max, Avg, Rng, T1-T2 (HH932T Only) and Std Dev\u003cbr\u003e \u003cb\u003eClock:\u003c\/b\u003e Real or elapsed time based on mode\u003cbr\u003e \u003cb\u003eOperating Environment\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature:\u003c\/b\u003e -20 to 55°C (-4 to 131°F)\u003cbr\u003e \u003cb\u003eHumidity:\u003c\/b\u003e 5 to 95%, 10 to 30°C (5 to 95%, 50 to 86°F)\u003cbr\u003e \u003cb\u003eAltitude:\u003c\/b\u003e0 to 15,092 ft. (0 to 4600 m)\u003cbr\u003e \u003cb\u003eVibration:\u003c\/b\u003e Random 10 to 500 Hz, 0.03 g2\/Hz\u003cbr\u003e \u003cb\u003eShock:\u003c\/b\u003e 30g Half Sine Drop: 4 drops from 1 m (3.3') to concrete\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 193 H x 84 W x 28 D mm (7.6 x 3.3 x 1.1')\u003cbr\u003e \u003cb\u003eWeight\u003c\/b\u003e 362.9 g (12.8 oz)\u003cbr\u003e \u003cb\u003eCommunication:\u003c\/b\u003e Bluetooth low energy technology\/version 4.0, 10 m (32.8') range\u003cbr\u003e \u003cb\u003eInternal Data Storage:\u003c\/b\u003e Last 1000 measurements with time stamp\u003cbr\u003e \u003cb\u003eStorage Modes:\u003c\/b\u003e Automatic and manual\u003cbr\u003e \u003cb\u003eRemote Operation:\u003c\/b\u003e Android™, Apple\u003csup\u003e®\u003c\/sup\u003e mobile device applications\u003cbr\u003e \u003cb\u003eInternet Data Collection:\u003c\/b\u003e Via mobile device app and https:\/\/hhthermocloud.omega.com\/\u003cbr\u003e \u003cb\u003eCloud\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eData Storage Rate:\u003c\/b\u003e User programmable, 1s minimum interval\u003cbr\u003e \u003cb\u003eWarranty:\u003c\/b\u003e 3 year parts and workmanship\u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e 2 year guarantee \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817407455527,"sku":"HH931T-HH932T","price":1386.47,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817407488295,"sku":"HH931T-HH932T","price":1386.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/hh931t-hh932t_l_l8b7rtezvke2khpq.jpg?v=1741316630"},{"product_id":"intrinsically-safe-temperature-data-logger","title":"Intrinsically Safe Temperature Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cp\u003eThe OM-CP-TEMP1000IS-A2 is an Intrinsically Safe temperature data logger. It carries hazardous location, intrinsically safe certification in accordance with the latest issue of FM3600, FM3610. This certification makes the device ideal for EtO Sterilization, environmental studies, and numerous other hostile environment applications.\u003c\/p\u003e \u003cp\u003eThe device can be started and stopped directly from your computer and its small, sleek size allows it to fit almost anywhere. The OM-CP-TEMP1000IS-A2 makes data retrieval quick and easy. Simply insert the device into the OM-CP-IFC400 or the OM-CP-IFC406 USB docking station (sold separately) and our user-friendly software does the rest. The small size of the OM-CP-TEMP1000IS-A2, allows it to be placed in remote or hard to reach locations. The device features a battery life indicator allowing users to easily identify low voltage and change batteries when required. This feature maximizes the use of your battery life and is a cost saving efficiency.\u003c\/p\u003e \u003cp\u003eThe OM-CP Data Logger Software is a powerful, analytic tool. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis.\u003c\/p\u003e \u003ch2\u003e Specifications \u003c\/h2\u003e \u003ctable border=\"2\" style=\"width: 35%\" bordercolor=\"#D8D8D8\"\u003e\n\u003cthead\u003e \u003ctr\u003e \u003cth colspan=\"4\"\u003e \u003cp align=\"left\" style=\"margin-left:10px\"\u003eTEMPERATURE\u003c\/p\u003e \u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eTemperature\u003cbr\u003e Sensor\u003c\/p\u003e\u003c\/td\u003e  \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eResistance Temperature Detector (RTD)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eTemperature \u003cbr\u003e Range\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e-40 °C to +80 °C (-40 °F to +176 °F)\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eTemperature \u003cbr\u003e Resolution\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e0.01 °C (0.018 °F)\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eCalibrated Accuracy\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e±0.5 °C (0 °C to ±50 °C)\u003cbr\u003e ±0.9 °F (32 °F to 122 °F)\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e \u003ctable border=\"2\" style=\"width: 35%\" bordercolor=\"#D8D8D8\"\u003e\n\u003cthead\u003e \u003ctr\u003e \u003cth colspan=\"4\"\u003e \u003cp align=\"left\" style=\"margin-left:10px\"\u003eGENERAL\u003c\/p\u003e \u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eMemory\u003c\/p\u003e\u003c\/td\u003e  \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e65,536 Readings\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eStart Modes\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eSoftware programmable immediate start\u003cbr\u003eor delay start, up to 24 months in advance\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eReal Time\u003cbr\u003e Recording\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eMay be used with PC to monitor and\u003cbr\u003erecord data in real time\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eReading Rate\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e4 Hz up to 1 reading every 24 hours\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eCalibration\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eDigital calibration through software\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eCalibration Date\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eAutomatically recorded within device\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eBattery Type\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eTadiran TL-2150 3.6V lithium battery \u003cbr\u003e included, user replaceable in a non-hazardous location\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eBattery Life\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e2 years typical at 15 minute reading rate\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eData Format\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eDate and time stamped °C, °F, K, °R\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eTime Accuracy\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e16 seconds \/ month -40 °C to 80 °C\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eComputer\u003cbr\u003eInterface\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eOM-CP-IFC400 or OM-CP-IFC406\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eOperating\u003cbr\u003eSystem\u003cbr\u003eCompatibility\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eWindows XP SP3\/7\/8\/10\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eSoftware\u003cbr\u003e Compatibility\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eStandard Software version 4.2.19.1 or later\u003cbr\u003e Secure Software version 4.2.18.0 or later\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eOperating\u003cbr\u003e Environment\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e-40 °C to +80 °C (-40 °F to +176 °F),\u003cbr\u003e  0 %RH to 100 %RH (case properly sealed)\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eDimensions\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e1 inch probe: 2.66 in x 0.97 in dia \u003cbr\u003e (67.6 mm x 24.6 mm dia.)\u003cbr\u003e 2 inch probe: 3.94 in x 0.97 in dia \u003cbr\u003e (100.1 mm x 24.6 mm dia.)\u003cbr\u003e 5.25 inch probe: 7.19 in x 0.97 in dia \u003cbr\u003e (182.6 mm x 24.6 mm dia.)\u003cbr\u003e 7 inch probe: 8.94 in x 0.97 in dia \u003cbr\u003e (227.1 mm x 24.6 mm dia.)\u003cbr\u003e\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eWeight\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e1 inch probe: 2.1 oz (60 g)\u003cbr\u003e 2 inch probe: 2.4 oz (68 g)\u003cbr\u003e 5.25 inch probe: 2.7 oz (76 g)\u003cbr\u003e 7 inch probe: 2.8 oz (78 g)\u003cbr\u003e\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eEnclosure\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003e316 Stainless Steel\/Radel\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eIP Rating\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eNot Rated \u003cbr\u003e Caution: Do not submerge this product to \u003cbr\u003e retain IS rating \u003cbr\u003e\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cp style=\"margin-left:10px\"\u003eApprovals\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e\u003cp style=\"margin-left:10px\"\u003eCE\u003cbr\u003eFM Class 3600, Rev. Jan 2018 \u003cbr\u003e FM Class 3610, Rev. Jan 2018 \u003cbr\u003e CAN\/CSA-C22.2 No. 60079-0:15\u003cbr\u003e CAN\/CSA-C22.2 No. 60079-11:14\u003c\/p\u003e\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817408307495,"sku":"OM-CP-TEMP1000IS-Lgr","price":534.08,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817408340263,"sku":"OM-CP-TEMP1000IS-Lgr","price":534.08,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-temp1000is-a2_450_s27lhvhxvlynbwa1.jpg?v=1741316653"},{"product_id":"handheld-programmer-and-data-collector-for-om-el-usb-series-loggers","title":"Handheld Programmer \u0026 Data Collector for OM-EL-USB Series Loggers","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-EL-DATAPAD allows users of compatible OM-EL-USB Series data loggers to configure their units and download data and view logging results on-the spot rather than removing the logger from the environment being measured and taking it to their PC. This allows continual logging with shorter breaks in data collection, less travel for the user, on-site data collection in graph, legend and summary format and the ability for users to reconfigure loggers in “the field”. The logger is connected to the OM-EL-DATAPAD via a standard USB port at the top of the viewer. Once connected, the user is guided through a simple touchscreen menu with options to set-up logger, stop logger and download and view data. \u003cbr\u003e\u003cbr\u003e On-screen instructions follow the same structure as the OM-EL-WIN-USB software for PC currently provided with each data logger. Data from up to 100 loggers can be viewed on the OM-EL-DATAPAD, with data from a further 400 units stored on the unit at any one time. Data can be transferred to a PC using a micro USB cable supplied with the unit. Once uploaded, data is saved in comma separated variable (csv) format, making it suitable for import into spreadsheet packages such as Microsoft Excel or graphed on a PC using the OM-EL-WIN-USB software. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e Battery: \u003c\/b\u003eLithium polymer, rechargeable via micro-USB connection (included)\u003cbr\u003e \u003cb\u003eLCD:\u003c\/b\u003e 240 x 320, 2.8' TFT with touch-screen\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e Internal flash\u003cbr\u003e \u003cb\u003eData Recording Capacity: \u003c\/b\u003e\u0026gt;8.5 million readings typical\u003cbr\u003e \u003cb\u003eOperating Time (On Single Charge):\u003c\/b\u003e 8 hours typical \u003cbr\u003e (5 hours continuous use)\u003cbr\u003e \u003cb\u003eOperating Temperature: \u003c\/b\u003e 0 to 50°C (32 to 122°F)\u003cbr\u003e \u003cb\u003eOperation: \u003c\/b\u003e Single front-panel push-button used for power-switch.\u003cbr\u003e Single press = ON, press and hold for 3 sec = OFF\u003cbr\u003e \u003cb\u003eData Logger Connection:\u003c\/b\u003e 1x USB Type A socket (top of unit)\u003cbr\u003e for connection of data loggers.\u003cbr\u003e \u003cb\u003ePC Connection:\u003c\/b\u003e 1x micro-USB (bottom of unit) for connection \u003cbr\u003eof unit to PC via 1 m (3.3') USB cable (included).\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 107 H x 68 W x 19 mm D (4.2 x 2.7 x 0.7')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 110 g (3.9 oz) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817408733479,"sku":"OM-EL-DATAPAD-Programmer","price":1024.47,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817408766247,"sku":"OM-EL-DATAPAD-Programmer","price":1024.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-el-datapad_l_llybhpubhbsnyltz.jpg?v=1741316678"},{"product_id":"pocket-size-temperature-humidity-and-dewpoint-data-logger","title":"Pocket Size Temperature\/Humidity and Dewpoint Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\n\u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\"\u003e \u003c!--\u003cb\u003e\u003cspan style=\"color:blue;\" _mce_style=\"color: blue;\"\u003e Please check out Newest Released Temperature and Humidity Portable Data Logger with LCD Display\u003ca href=\"https:\/\/www.omega.com\/pptst\/OM-HL-SH.html\" _mce_href=\"https:\/\/www.omega.com\/pptst\/OM-HL-SH.html\" class=\"blLink\"\u003e OM-HL-SH Series \u003c\/a\u003e for more advanced features with better price.\u003c\/b\u003e\u003cbr\/\u003e\u003cbr\/\u003e --\u003e The reliable and accurate RH32 Series Temperature\/Relative Humidity Meters measure and display both temperature from -10 to 50°C (14 to 122°F) and humidity from 0-100% RH. It has the datalogging capability to store up to 8000 readings of both temperature and humidity into memory. The data can be stored either manually or automatically from once a minute to once an hour over a specified time period entered in calendar time (month\/day\/hours\/mins).\u003cbr\u003e\u003cbr\u003e Three types of sensors are available. A built-in sensor, a small separate sensor and a probe type sensors. The model comes with one type of sensor when purchased, but all sensors can plug into the units and are easily interchangeable without special calibration.\u003cbr\u003e\u003cbr\u003e RS232C communication interface is available along with optional software for analysis of measured data. The software allows for easy transfer of data to a computer either in real time or of data stored in memory. A trend graph can be displayed on the computer screen. The data can also be exported to a spreadsheet.\u003cbr\u003e\u003cbr\u003e The RS485 communication allows up to 30 units to be connected to a computer for real time temperature\/humidity measurement applications.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e\u003cbr\u003e   \u003cb\u003eSensor\u003c\/b\u003e: Capacitance type\u003cbr\u003e   \u003cb\u003eMeasuring Range:\u003c\/b\u003e 0 to 100% RH\u003cbr\u003e   \u003cb\u003eAccuracy Rating: \u003c\/b\u003e2% RH (0 to 90% RH and 25°C [76°F]), ±3% RH (90 to 95% RH and 25°C [76°F])\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e ±0.1% RH\/°C (5 to 80°C [41 to 176°F])\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e Within 15 seconds (90% response, 25°C constant, under 0.1 m\/s ventilation)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eTemperature\u003c\/b\u003e\u003cbr\u003e   \u003cb\u003eSensor:\u003c\/b\u003e Semiconductor type temperature sensor\u003cbr\u003e   \u003cb\u003eMeasuring Range:\u003c\/b\u003e RH32B: -10 to 50°C (14 to 122°F), RH32S \u0026amp; RH32P: -40 to 80°C (-40 to 176°F)\u003cbr\u003e   \u003cb\u003eAccuracy: \u003c\/b\u003e±0.5°C from 0 to 50°C, ±1°C below 0°C or above 50°C\u003cbr\u003e \u003cb\u003eSensor Interchangeability:\u003c\/b\u003e Interchangeable by plug-in. For probe type and separate type, interchangeable including cable\u003cbr\u003e\u003cbr\u003e \u003cb\u003ePower Supply:\u003c\/b\u003e 2 AA batteries included or 100 to 240 Vac with optional AC adaptor\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDisplay\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Data: \u003c\/b\u003eMonth, day, hour, minute. Temperature reading (°C or °F).\u003cbr\u003e Relative humidity or dew-point temperature reading (°C or °F) \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817409061159,"sku":"RH32-Series","price":1131.58,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817409093927,"sku":"RH32-Series","price":1131.58,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/rh32_l_j2biwvs8yrwmy4es.jpg?v=1741316699"},{"product_id":"wireless-thermocouple-temperature-data-logger-with-display","title":"Wireless Thermocouple Temperature Data Logger with Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-RFTCTEMP2000A is a wireless thermocouple based data logger with digital display. The device measures ambient temperatures, as well as remote temperature via a thermocouple (sold separately), making it ideal for monitoring perishable goods, vaccine storage, chemicals and more. Starting, stopping and downloading from the device are all performed wirelessly using the OM-CP-RFC1000-EXT wireless transceiver, allowing the customer to spend less time maintaining the data logger. Data can be provided in real time back to a central PC, or the device may be downloaded at period intervals. The convenient digital display provides the current reading for both channels. Minimum, maximum and average statistics are also provided for a convenient snap shot of the logged data. For instant, out of range notification, an audible buzzer as well as LED alarm indicator notifies users when the temperature is above or below the user specified alarm. Through the software, email and text message alarms can also be sent. The OM-CP-RFTCTEMP2000A also features programmable trigger settings for applications in which temperature logging is critical only above or below a certain temperature. This information may be programmed into the device, and the data logger will only begin to log data to memory, once the temperature limit has been exceeded. The OM-CP-RFTCTEMP2000A can be used as a single, wireless data logging system, yet can be expanded to a large scale system, which can include hundreds of data loggers measuring a number of areas (additional wireless loggers and transceivers may be required). Data retrieval is simple. Plug the device into an available USB port and our easy-to-use software does the rest. The software converts a PC into a real-time strip chart recorder. The data logger software is a powerful, analytic tool. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817409945895,"sku":"OM-CP-RFTCTEMP2000A-Logger","price":831.26,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817409978663,"sku":"OM-CP-RFTCTEMP2000A-Logger","price":831.26,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-rftctemp2000a_l_mqrlnignib1a1qpx.jpg?v=1741316724"},{"product_id":"high-temperature-data-logger-with-flexible-probe","title":"High Temperature Data Logger With Flexible Probe","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-HITEMP140-FP is a durable, user friendly high temperature data logger featuring a long, flexible RTD probe with a narrow diameter, making it ideal for use in steam sterilization and lyophilization processes. Commonly used for mapping, validation and monitoring of high temperature surfaces and environments, this stainless steel data logger is available in two models, the OM-CP-HITEMP140-FP-36 and the OM-CP-HITEMP140-FP-72, which feature either a 91.4 cm (36') or 183 cm (72') flexible probe length. The flexible probe is coated with PFA insulation and can withstand temperatures up to 260°C (500°F) with an accuracy of ±0.1°C (±0.18°F). The OM-CP-HITEMP140-FP is also available with an optional thermal shield enclosure to extend the operating range of the data logger to -200 to 250°C (-328 to 482°F). The OM-CP-HITEMP140-FP-TSK (Thermal Shield Kit) comes with either a vented or flush top enclosure to accommodate a multitude of applications.\u003cbr\u003e\u003cbr\u003e The OM-CP-HITEMP140-FP probe design is narrow and lightweight making it ideal for placement within small vials, tubing, test tube and other small diameter or delicate applications. Because of the flexible probe, the risks of breakage (both vial and probe) generally associated with stainless steel probe data loggers are diminished and the location and placement of the probe is easy to manipulate. The device records and stores up to 32,700 time stamped readings and is equipped with non-volatile solid state memory which retains data even if the battery becomes discharged.\u003cbr\u003e\u003cbr\u003e The OM-CP-MULTIMOUNT-Z is a versatile mount or stand for use with the OM-CP-HITEMP140 series of data loggers. It can be used to stabilize a logger inside an autoclave, or screwed to a flat surface to create an anchored base. Made of 316 stainless steel, the OM-CP-MULTIMOUNT-Z is able to withstand temperatures up to 150°C (302°F) making it ideal for use in autoclave sterilization processes. \u003cbr\u003e\u003cbr\u003e The OM-CP-HITEMP140-FP utilizes the latest software. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOM-CP-HITEMP140-FP (Data Logger Without Thermal Shield)\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTEMPERATURE\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature Sensor:\u003c\/b\u003e Flexible 100 Ω platinum RTD\u003cbr\u003e \u003cb\u003eProbe Measurement Range:\u003c\/b\u003e -60 to 260°C (-76 to 500°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.01°C (0.02°F)\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±0.1°C (±0.18°F)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eData Logger Response Time (Hours: Minutes: Seconds: Fractions of a Second):\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eIn Air:\u003c\/b\u003e\u003cbr\u003e t60 - 00:00:30:00 (30 sec to reach 60% of step change)\u003cbr\u003e t90 - 00:00:70:00 (70 sec to reach 90% of step change)\u003cbr\u003e     \u003cb\u003eIn Water:\u003c\/b\u003e\u003cbr\u003e t60 - 00:00:03:50 (3.5 sec to reach 60% of step change)\u003cbr\u003e t90 - 00:00:06:50 (6.5 sec to reach 90% of step change)\u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e 4 readings per second up to 1 reading every 24 hours\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 32,767 readings\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Software programmable immediate start\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Delay start up to 18 months in advance\u003cbr\u003e \u003cb\u003eStop Modes:\u003c\/b\u003e Manual or Timed (specific date and time)\u003cbr\u003e \u003cb\u003eTrigger Settings:\u003c\/b\u003e High and low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers.\u003cbr\u003e \u003cb\u003eReadings in Trigger Settings Mode:\u003c\/b\u003e 10,922 readings\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e May be used with PC to monitor and record data in real time\u003cbr\u003e \u003cb\u003ePassword Protection:\u003c\/b\u003e An optional password may be programmed into the device to restrict access to configuration options. Data may be read without the password.\u003cbr\u003e \u003cb\u003eMemory Wrap Around:\u003c\/b\u003e Yes\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e 3.6V high-temperature lithium battery included; user replaceable\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 1 year typical [1 minute reading rate at 25°C (77°F)]\u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e Digital calibration through software\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Automatically recorded within device\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped °C, °F, °R, K\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±1 minute\/month at 25°C (77°F)\u003cbr\u003e \u003cb\u003eExtended Operation:\u003c\/b\u003e ±20 minutes\/month at 140°C (284°F)\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows XP SP3\/Vista\/7 and 8 (32- and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 140°C (-40 to 284°F), 0 to 100% RH\u003cbr\u003e \u003cb\u003eIP Rating:\u003c\/b\u003e IP68\u003cbr\u003e \u003cb\u003eDimensions (Body):\u003c\/b\u003e 75 H x 24.6 mm D (2.95 x 0.97')\u003cbr\u003e \u003cb\u003eDimensions (Probe):\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOM-CP-HITEMP140-FP-36:\u003c\/b\u003e 91.4 cm L x 2.5 mm dia (36 x 0.1')\u003cbr\u003e \u003cb\u003eOM-CP-HITEMP140-FP-72:\u003c\/b\u003e 183 cm L x 2.5 mm dia (72 x 0.1')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 85 g (3 oz)\u003cbr\u003e \u003cb\u003eMaterials:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eBody:\u003c\/b\u003e 316 SS\u003cbr\u003e     \u003cb\u003eProbe:\u003c\/b\u003e PFA insulated cable\u003cbr\u003e \u003cb\u003eOM-CP-MULTIMOUNT-Z\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMaterial:\u003c\/b\u003e 316 SS\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 44.5 H x 38 L x 38 mm W (1.75 x 1.5 x 1.5') \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817410371879,"sku":"OM-CP-HITEMP140-FP-Series","price":1336.89,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817410404647,"sku":"OM-CP-HITEMP140-FP-Series","price":1336.89,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-hitemp140-fp_l_zall0wwyoxdg0quw.jpg?v=1741316747"},{"product_id":"miniature-submersible-temperature-data-logger","title":"Miniature Submersible Temperature Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-MICROTEMP is a miniature, submersible, self-contained temperature data logger that can record up to 32,767 measurements. Only 66 mm (2.6') tall and 18 mm (0.7') in diameter, it can fit in the smallest spaces—even down the neck of a beverage bottle! This industrial-grade instrument can operate in temperatures from -40 to 80ºC (-40 to 176ºF) and is accurate to ±0.5ºC (0.9ºF). Its stainless steel casing is designed for use with most common fluids and gases. Applications include pharmaceuticals, biomedical research, food processing, and transport. \u003cbr\u003e\u003cbr\u003e With the Windows-based software, the user can view temperature readings in Celsius, Fahrenheit, Kelvin, and Rankine. The software can also calculate pasteurization units and mean kinetic temperature. Data can be printed in graphic or tabular format, or exported to a text or Microsoft Excel file. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e Temperature Sensor:\u003c\/b\u003e Internal semiconductor\u003cbr\u003e \u003cb\u003eTemperature Range:\u003c\/b\u003e -40 to 80°C (-40 to 176°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.1°C (0.2°F)\u003cbr\u003e \u003cb\u003eTemperature Accuracy:\u003c\/b\u003e ±0.5°C\u003cbr\u003e (0.9°F) 0 to 50°C (32 to 122°F)\u003cbr\u003e \u003cb\u003eAlarm: \u003c\/b\u003eProgrammable high and low limits; \u003cbr\u003ealarm is activated when temperature reaches or exceeds set limits\u003cbr\u003e \u003cb\u003eLED Indicators: \u003c\/b\u003eGreen LED blinks to indicate device has been started, \u003cbr\u003ered LED blinks if an alarm condition exists, \u003cbr\u003e(LEDs are inside the end cap of the data logger)\u003cbr\u003e \u003cb\u003eCalibration: \u003c\/b\u003eDigital calibration through software\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Automatically recorded within device\u003cbr\u003e \u003cb\u003eReal-Time Recording: \u003c\/b\u003eCan be used with PC to monitor and record data in real time\u003cbr\u003e \u003cb\u003eMemory: \u003c\/b\u003e32,767 readings per channel; software-configurable memory wrap\u003cbr\u003e \u003cb\u003eReading Interval: \u003c\/b\u003e1 reading every 2 seconds to 1 every 12 hours\u003cbr\u003e \u003cb\u003eStart Time:\u003c\/b\u003e Software programmable start time and date (up to 6 months in advance)\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped, °C, °F, K, °R\u003cbr\u003e \u003cb\u003ePower: \u003c\/b\u003e3.6 V lithium battery (included)\u003cbr\u003e \u003cb\u003eBattery Life: \u003c\/b\u003e1 year typical (15-minute reading rate, 25°C)\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±1 min\/month @ 20°C (68°F)\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e PC serial or USB (interface cable required); 38,400 baud\u003cbr\u003e \u003cb\u003eSoftware: \u003c\/b\u003eXP SP3\/Vista and 7 (32 and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 80°C (-40 to 176°F);\u003cbr\u003e 0 to 100% RH, non-condensing\u003cbr\u003e \u003cb\u003eSubmersion Depth:\u003c\/b\u003e Up to 46 m (150')\u003cbr\u003e \u003cb\u003eDimensions: \u003c\/b\u003e66 L x 18 mm Dia.\u003cbr\u003e (2.6 x 0.7')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 50 g (1.8 oz)\u003cbr\u003e \u003cb\u003eMaterial: \u003c\/b\u003e316L SS (food grade) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817411387687,"sku":"OM-CP-MICROTEMP-Logger","price":538.37,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817411420455,"sku":"OM-CP-MICROTEMP-Logger","price":538.37,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-microtemp_l_p708akljhxr6f9fv.jpg?v=1741316772"},{"product_id":"temperature-humidity-data-loggers-with-2-external-inputs","title":"Temperature\/Humidity Data Loggers with 2 External Inputs","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OMYL-RH25 is a temperature\/humidity data logger that also accepts two external temperature or temperature\/humidity inputs. This data logger is available with standard memory of 100,000 readings (OMYL-RH25) or expanded memory of 4 million readings (OMYL-RH25-4M). The following inputs can be configured:\u003cbr\u003e\u003cbr\u003e • Internal temperature and humidity sensors\u003cbr\u003e • External temperature (Pt100\/Pt1000 RTD, Type U thermistor)\u003cbr\u003e • External temperature\/humidity (for combined external temperature\/humidity probes)\u003cbr\u003e\u003cbr\u003e The storage medium is non-volatile flash memory so no data is lost if the battery becomes discharged. Data logger setup as well as data retrieval is accomplished using the included standard OMYL-SOFT software. Downloaded data is stored in the OMYL-SOFT software as a text file for viewing in third party software packages or Microsoft Excel. The OMYL-SOFT standard software does not include any graphing functionality. Graphing and analyzing downloaded data files requires the OMYL-SOFT-PLUS version of the software (sold separately).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInternal Temperature\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eTemperature Range:\u003c\/b\u003e -30 to 70°C (-22 to 158°F) with standard lithium battery; -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery\u003cbr\u003e     \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.01°C (0.02°F)\u003cbr\u003e     \u003cb\u003eAccuracy:\u003c\/b\u003e See chart on PDF\u003cbr\u003e \u003cb\u003eExternal Temperature Input\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eSensor:\u003c\/b\u003e Pt100 or Pt1000 RTD, U thermistor (2000Ω @ 25°C)\u003cbr\u003e     \u003cb\u003eRange:\u003c\/b\u003e -70 to 250°C (-94 to 482°F)\u003cbr\u003e     \u003cb\u003eResolution:\u003c\/b\u003e 0.01°C (0.02°F)\u003cbr\u003e     \u003cb\u003eAccuracy:\u003c\/b\u003e See chart on PDF\u003cbr\u003e \u003cb\u003eInternal\/External Humidity\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eHumidity Range:\u003c\/b\u003e 0 to 100% RH\u003cbr\u003e     \u003cb\u003eHumidity Resolution:\u003c\/b\u003e 0.01% RH\u003cbr\u003e     \u003cb\u003eAccuracy:\u003c\/b\u003e See chart on PDF\u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e 1 second to 24 hours; 2 Hz, 4 Hz in fast mode\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e Immediate start, delayed start\u003cbr\u003e \u003cb\u003eMemory Capacity\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOMYL-RH25:\u003c\/b\u003e 100,000 readings\u003cbr\u003e     \u003cb\u003eOMYL-RH25-4M:\u003c\/b\u003e 4 million readings\u003cbr\u003e \u003cb\u003eMemory Wrap Around:\u003c\/b\u003e Yes (software configurable)\u003cbr\u003e \u003cb\u003eBattery:\u003c\/b\u003e 3V lithium battery [standard temperature range battery (included), optional high temperature range battery]; user replaceable\u003cbr\u003e \u003cb\u003eBattery Life (Standard Temperature Range Battery):\u003c\/b\u003e 4 years at 1 minute reading rate, 230 days at 10 second reading rate, 25 days at 1 second reading rate\u003cbr\u003e \u003cb\u003eLED Functionality:\u003c\/b\u003e Integrated status LED indicates data logging status, low battery or alarm condition\u003cbr\u003e \u003cb\u003eAlarms:\u003c\/b\u003e Software programmable high\/low thresholds\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e USB (interface cable included)\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e XP SP3\/Vista\/7 and 8 (32- and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -30 to 70°C (-22 to 158°F) with standard lithium battery; -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 30 H x 50 mm dia (1.18 x 1.97')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (2.5 oz)\u003cbr\u003e \u003cb\u003eEnclosure:\u003c\/b\u003e Robust, shock-proof POM, IP65 \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817411780903,"sku":"OMYL-RH25-Series","price":1192.71,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817411813671,"sku":"OMYL-RH25-Series","price":1192.71,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/omyl-rh25_l_7mj1t2rroewiuthq.jpg?v=1741316794"},{"product_id":"8-channel-benchtop-cryogenic-digital-thermometer-datalogger","title":"8 Channel Benchtop Cryogenic Digital Thermometer Datalogger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   The model CYD211 Temperature Monitor provides the accuracy, resolution, and interface features of a benchtop temperature monitor in an easy to use, compact instrument. With appropriate sensors, the CYD211 measures temperature from 1.4 to 800 K and in difficult sensing conditions, including high vacuum and magnetic fields. Standard features on the CYD211 include alarms, relays, user-configurable analog voltage or current output, and a serial interface. The CYD211 is an ideal choice for liquefied gas storage\/monitoring, cryopump control, cryo-cooler, and materials science applications, and for applications that require greater accuracy than thermocouples allow.\u003cbr\u003e The CYD218 has all the features of the CTD211 plus 8 inputs for silicon diodes or PT RTD's, 16 Hi\/Lo Alarms, latching or non-latching relays, Data Logging with 1500 point memory and printer output.  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817412534567,"sku":"CYD211-CYD218E-CYD218S","price":15401.87,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817412567335,"sku":"CYD211-CYD218E-CYD218S","price":15401.87,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/cyd211-cyd218e-cyd218s-l_v9xoucl8eho7pcog.jpg?v=1741316815"},{"product_id":"high-temperature-data-loggers-dual-remote-temperature-probes","title":"High Temperature Data Loggers, Dual Remote Temperature Probes","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-HITEMP140X2-FP Series of dual channel high temperature data loggers feature a stainless steel data logger body and are available with either two 183 cm (72') flexible probes (OM-CP-HITEMP140X2-FP-72) or with one flexible probe and a stainless steel bendable probe combination (OM-CP-HITEMP140X2-FP-72-PT-1 and OM-CP-HITEMP140X2-FP-72-PT-5).\u003cbr\u003e\u003cbr\u003e The dual probes of the OM-CP-HITEMP140X2-FP Series allow for simultaneous temperature monitoring and provide flexibility in applications such as oven mapping, surface temperature monitoring, autoclave validation and sterilization processes.\u003cbr\u003e\u003cbr\u003e The OM-CP-HITEMP140X2-FP-72 model offers two 183 cm (72') long, lightweight, flexible RTD probes coated with PFA insulation. The FP probe design allows the probe to be easily maneuvered and is ideal for temperature monitoring inside test tubes, small vials, and other delicate applications. The narrow thermistor probe tip is compatible for use with the OM-CP-MICRODISC probe attachment allowing for precise surface temperature monitoring of shelving and more.\u003cbr\u003e\u003cbr\u003e The OM-CP-HITEMP140X2-FP-72-PT-1 and OM-CP-HITEMP140X2-FP-72-PT-5 models feature a 61 cm (24') stainless steel bendable probe with the option of either a 2.5 cm (1') or 12.7 cm (5') probe tip (sheath). The stainless steel probe can be bent, angled, and coiled in any direction and formed into position as needed. The sharp probe tip allows for easy insertion and has an extended measurement range of -200 to 350°C (-328 to 662°F).\u003cbr\u003e\u003cbr\u003e The body of the OM-CP-HITEMP140X2-FP data loggers are capable of operating in temperatures from -40 to 140°C (-40 to 284°F). All models have the capacity to store up to 32,700 time and date stamped readings and feature non-volatile solid state memory that will retain data even if the battery becomes discharged.\u003cbr\u003e\u003cbr\u003e The OM-CP-HITEMP140X2-FP utilizes the latest software. The device can be started, stopped, and data can be downloaded quickly and easily. Once in the software, the data can be reviewed in graphic, tabular, or summary form as well as exported to Excel® for further analysis and calculations.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTEMPERATURE\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature Sensor:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-CP-HITEMP140X2-FP:\u003c\/b\u003e Flexible RTD probe\u003cbr\u003e     \u003cb\u003eOM-CP-HITEMP140X2-FP-PT:\u003c\/b\u003e Flexible RTD Probe and bendable RTD probe\u003cbr\u003e \u003cb\u003eProbe Measurement Range:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eFlexible Probe:\u003c\/b\u003e -60 to 260°C (-76 to 500°F)\u003cbr\u003e     \u003cb\u003eBendable Probe:\u003c\/b\u003e -200 to 350°C (-328 to 662°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.01°C (0.02°F)\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±0.1°C (±0.18°F)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e 1 reading every second up to 1 reading every 24 hours\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 32,767 readings\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Software programmable immediate start\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Delay start up to 18 months in advance\u003cbr\u003e \u003cb\u003eStop Modes:\u003c\/b\u003e Manual or Timed (specific date and time)\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e May be used with PC to monitor and record data in real time\u003cbr\u003e \u003cb\u003ePassword Protection:\u003c\/b\u003e An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password\u003cbr\u003e \u003cb\u003eReadings in Trigger Settings Mode:\u003c\/b\u003e 16,383 readings\u003cbr\u003e \u003cb\u003eTrigger Settings:\u003c\/b\u003e High and Low limits may be set. Once data meets or exceed set limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers. (Triggering on channel 1 only)\u003cbr\u003e \u003cb\u003eMemory Wrap Around:\u003c\/b\u003e Yes (software selectable)\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e 3.6V high-temperature lithium battery included; user replaceable\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 1 year typical [1 minute reading rate at 25°C (77°F)]\u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e Digital calibration through software\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Automatically recorded within device\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped °C, °F, °R, K\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e 1 minute\/month @ 25°C (77°F)\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows XP SP3\/Vista\/7 and 8 (32- and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 140°C (-40 to 284°F), 0 to 100% RH, 0.002 to 100 psia\u003cbr\u003e \u003cb\u003eIP Rating:\u003c\/b\u003e IP68\u003cbr\u003e \u003cb\u003eDimensions (Body):\u003c\/b\u003e 48 H x 24.6 mm dia (1.89 x 0.97')\u003cbr\u003e \u003cb\u003eDimensions (Probe):\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-CP-HITEMP140X2-FP-72:\u003c\/b\u003e\u003cbr\u003e       \u003cb\u003eFlexible Probe:\u003c\/b\u003e 1829 L x 2.5 mm dia (72 x 0.1')\u003cbr\u003e     \u003cb\u003eOM-CP-HITEMP140X2-FP-72-PT-1 with 2.5 cm (1')\u003c\/b\u003e\u003cbr\u003e       \u003cb\u003eBendable Probe:\u003c\/b\u003e\u003cbr\u003e       \u003cb\u003eProbe Tip:\u003c\/b\u003e 42 L x 3.2 mm dia (1.7 x 0.125')\u003cbr\u003e       \u003cb\u003eBendable Portion:\u003c\/b\u003e 559 L x 1.6 mm dia (22 x 0.062')\u003cbr\u003e     \u003cb\u003eOM-CP-HITEMP140X2-FP-72-PT-5 with 12.7 cm (5')\u003c\/b\u003e\u003cbr\u003e       \u003cb\u003eBendable Probe:\u003c\/b\u003e\u003cbr\u003e       \u003cb\u003eProbe Tip:\u003c\/b\u003e 121 L x 3.2 mm dia (4.8 x 0.125') with 25 L x 4.8 mm dia (1 x 0.188') handle\u003cbr\u003e       \u003cb\u003eBendable Portion:\u003c\/b\u003e 559 L x 1.6 mm dia (22 x 0.062')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eOM-CP-HITEMP140X2-FP-72:\u003c\/b\u003e 115 g (4.1 oz)\u003cbr\u003e     \u003cb\u003eOM-CP-HITEMP140X2-FP-72-PT:\u003c\/b\u003e 110 g (3.9 oz)\u003cbr\u003e \u003cb\u003eMaterials:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eBody:\u003c\/b\u003e 316 stainless steel, PEEK\u003cbr\u003e     \u003cb\u003eBendable Probe:\u003c\/b\u003e 316 stainless steel\u003cbr\u003e     \u003cb\u003eFlexible Probe:\u003c\/b\u003e PFA insulated cable\u003cbr\u003e \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817412731175,"sku":"OM-CP-HITEMP140X2-FP-Series","price":2395.86,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817412763943,"sku":"OM-CP-HITEMP140X2-FP-Series","price":2395.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-hitemp140x2-fp_l_kwxwrhtckzhsq2se.jpg?v=1741316838"},{"product_id":"ultra-low-temperature-data-logger","title":"Ultra Low Temperature Data Logger","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\"\u003e The OM-CP-CRYO-TEMP ultra low temperature data logger records temperatures as low as -86°C (-122ºF). The OM-CP-CRYO-TEMP can be used in a broad line of applications such as monitoring blood plasma, vaccines, pharmaceutical, frozen foods and shipping containers.This stand-alone device does not require any additional probes. The enclosure is designed with a handle for easy attachment and is IP65 splash resistant. \u003cbr\u003e\u003cbr\u003e It utilizes a USB docking station (sold separately), to communicate with a personal computer or laptop. The OM-CP-CRYO-TEMP provides date and time stamped temperature readings. Our easy-to-use Windows software does the rest. The user can view the data in graphical or tabular form. High and low alarm limits and high and low warning limits can be programmed through the software.\u003cbr\u003e\u003cbr\u003e The user can set the alarm limits in the range required for the goods to be maintained. The warning limits can be set to alert the user when the temperature is nearing a high or low alarm limit, so that proper action can be taken to ensure the integrity of the goods.\u003cbr\u003e\u003cbr\u003e The OM-CP-CRYO-TEMP is equipped with three LED’s. The green LED will blink every 15 seconds while the recorder is logging data. The yellow LED will blink every 3 seconds when the temperature has breached the warning limits. The red LED will blink every 3 seconds when the temperature alarm limits have been exceeded.\u003cbr\u003e\u003cbr\u003e The OM-CP-CRYO-TEMP is the ideal temperature monitoring solution for any application involving ultra low temperature recording. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature Sensor:\u003c\/b\u003e NTC Thermistor\u003cbr\u003e \u003cb\u003eTemperature Measurement Range:\u003c\/b\u003e -86 to 35°C (-122 to 95°F) recommended, \u003cbr\u003emay be used up to 55°C (131°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.1°C\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±1.0°C\u003cbr\u003e \u003cb\u003eReadings: \u003c\/b\u003e32,767\u003cbr\u003e \u003cb\u003eRecording Interval:\u003c\/b\u003e 5 seconds to 30 minutes, selectable in software\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e Immediate start, delay start or manual start with magnetic switch\u003cbr\u003e \u003cb\u003eProgrammable Start Delay: \u003c\/b\u003eUp to 30 days from PC launch or manual start\u003cbr\u003e \u003cb\u003eTemperature Alarm:\u003c\/b\u003e Software programmable high and low alarm limits, \u003cbr\u003ehigh and low warning limits; each setpoint may be individually enabled or disabled\u003cbr\u003e \u003cb\u003eAlarm Delay:\u003c\/b\u003e Software programmable time delay for warning\/alarm limits; \u003cbr\u003elogger will not indicate out of range status until the temperature \u003cbr\u003ehas been out of range for a set period of time\u003cbr\u003e \u003cb\u003eStatus Indicators:\u003c\/b\u003e \u003cbr\u003e \u003cb\u003eGreen:\u003c\/b\u003e Blinks to indicate safe conditions during logging\u003cbr\u003e \u003cb\u003eYellow:\u003c\/b\u003e Blinks to indicate warn limits have been exceeded\u003cbr\u003e \u003cb\u003eRed:\u003c\/b\u003e Blinks to indicate alarm criteria (limits\/delay) have been exceeded\u003cbr\u003e \u003cb\u003ePassword Protection:\u003c\/b\u003e An optional password may be programmed\u003cbr\u003e into the device to restrict access to configuration options;\u003cbr\u003e data may be read out without the password\u003cbr\u003e \u003cb\u003eCalibration: \u003c\/b\u003eDigital calibration is available to the user through software\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Automatically recorded within device\u003cbr\u003e \u003cb\u003ePower: \u003c\/b\u003e3.6 V lithium battery included)\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e \u003cbr\u003e \u003cb\u003e2 Years: \u003c\/b\u003eTypical @ 25°C, 1 min reading intervals\u003cbr\u003e \u003cb\u003e1 Year:\u003c\/b\u003e Typical @ -80°C, 1 min reading intervals\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±2 minutes\/month max at 20 to 30°C; \u003cbr\u003e±5 minutes\/month max at -80°C\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped °C, °F, K, °R\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e USB docking station to PC; 38,400 baud\u003cbr\u003e \u003cb\u003eSoftware: \u003c\/b\u003eXP SP3\/Vista\/7 and 8 (32 and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -86 to 35°C (-122 to 95°F)\u003cbr\u003e may be used up to 55°C (131°F); 0 to 100% RH\u003cbr\u003e \u003cb\u003eDimensions: \u003c\/b\u003e83 H x 54 W x 11 mm D (3.3 x 2.1 x 0.4') \u003cbr\u003e \u003cb\u003eIngress Protection\/IP Rating: \u003c\/b\u003eIP65 (splash resistant, not submersible)\u003cbr\u003e \u003cb\u003eEnclosure:\u003c\/b\u003e ABS plastic, white, polycarbonate labeling\u003cbr\u003e \u003cb\u003eWeight: \u003c\/b\u003e40 g (1.4 oz) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817413058855,"sku":"OM-CP-CRYO-TEMP-Logger","price":590.99,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817413091623,"sku":"OM-CP-CRYO-TEMP-Logger","price":590.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-cryo-temp_l_zahijyzlwbh9t7dx.jpg?v=1741316864"},{"product_id":"high-temperature-data-logger-with-integral-m12-connector","title":"High Temperature Data Logger With Integral M12 Connector","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-HITEMP140-M12 is a rugged and versatile high temperature data logger featuring an M12 probe connector. Compatible with a wide variety of M12 RTD probe styles, this data logger is capable of measuring up to 850°C (1562°F) (probe dependent). With the ability to change probes as needed, this device satisfies a multitude of application needs with one powerful data logger versus the need for multiple loggers.\u003cbr\u003e\u003cbr\u003e The OM-CP-HITEMP140 data logger has a water tight body enclosure made of food grade stainless steel. It can be placed in environments with temperatures as high as 140°C (284°F) making it suitable for a wide range of applications including autoclave verification, food preparation and processing, environmental studies, well monitoring, washer disinfectors and pasteurization. The OM-CP-HITEMP140-M12 records and stores up to 43,690 time stamped readings and is equipped with non-volatile solid state memory which retains data even if the battery becomes discharged.\u003cbr\u003e\u003cbr\u003e Using the OM-CP-HITEMP140-M12 software, starting, stopping and downloading the OM-CP-HITEMP140-M12 is simple and easy. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R. The data can also be automatically exported to Excel® for further calculations.\u003cbr\u003e\u003cbr\u003e The OM-CP-MULTIMOUNT-Z is a versatile mount or stand for use with the OM-CP-HITEMP140 series of data loggers. It can be used to stabilize a logger inside an autoclave, or screwed to a flat surface to create an anchored base. The OM-CP-MULTIMOUNT-Z is made of stainless steel and is able to withstand temperatures up to 150°C (302°F) making it ideal for use in autoclave sterilization processes.\u003cbr\u003e\u003cbr\u003e The OM-CP-ALUCASE-14 and OM-CP-ALUCASE-18 are high quality, multi-purpose briefcases, designed for the protection, transport and storage of data loggers, equipment and accessories. These durable aluminum cases include pick and pluck foam inserts, allowing the user to customize a snug fit and secure any combination of products. The briefcase frame is strong yet surprisingly light weight with a comfortable ergonomically upholstered handle. Two sizes are available: a compact 36 cm (14') width (OM-CP-ALUCASE-14) and large 47 cm (18') width (OM-CP-ALUCASE-18), both featuring an egg crate foam lined lid and keyed locks.\u003cbr\u003e\u003cbr\u003e The OM-CP-IFC406 is a multiplexer data logger interface for compatible OM-CP Series data loggers. The OM-CP-IFC406 allows up to six data loggers to be connected into one interface. Up to three OM-CP-IFC406 units may be daisy-chained together to communicate with a total of 18 data loggers through one USB port. To connect multiple OM-CP-IFC406 multiplexer interfaces together, simply join the units side by side, making sure the spring pin contacts are connected and magnetically joined.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTemperature Sensor:\u003c\/b\u003e Pt100 RTD probe with M12 connector (probe sold separately)\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 18 to 400 Ω; -200 to 850°C (-328 to 1562°F) (probe dependent)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.0001 Ω; 0.01°C (0.018°F) (probe dependent)\u003cbr\u003e \u003cb\u003eCalibrated Accuracy:\u003c\/b\u003e ±0.015 Ω; ±0.05°C (±0.09°F) (probe dependent)\u003cbr\u003e \u003cb\u003eCalibrated Accuracy Range:\u003c\/b\u003e 18 to 200 Ω; -200 to 265°C (-328 to 509°F)\u003cbr\u003e \u003cb\u003eConnector Type:\u003c\/b\u003e M12 female, 4-pin\u003cbr\u003e \u003cb\u003eReading Rate:\u003c\/b\u003e 4 readings per second up to 1 reading every 24 hours\u003cbr\u003e \u003cb\u003eMemory:\u003c\/b\u003e 43,690 readings\u003cbr\u003e \u003cb\u003eStart Modes:\u003c\/b\u003e\u003cbr\u003e     • Software programmable immediate start\u003cbr\u003e     • Delay start up to 18 months in advance\u003cbr\u003e \u003cb\u003eStop Modes:\u003c\/b\u003e Manual or timed (specific date and time)\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e May be used with PC to monitor and record data in real time\u003cbr\u003e \u003cb\u003ePassword Protection:\u003c\/b\u003e An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password\u003cbr\u003e \u003cb\u003eTrigger Settings:\u003c\/b\u003e High and low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers\u003cbr\u003e \u003cb\u003eReadings in Trigger Settings Mode:\u003c\/b\u003e 18,724 readings\u003cbr\u003e \u003cb\u003eMemory Wrap Around:\u003c\/b\u003e Yes\u003cbr\u003e \u003cb\u003eBattery Type:\u003c\/b\u003e 3.6V high-temperature lithium battery included; user replaceable\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 2 years typical [1 minute reading rate at 25°C (77°F)]\u003cbr\u003e \u003cb\u003eCalibration:\u003c\/b\u003e Digital calibration through software\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Automatically recorded within device\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped °C, °F, °R, K\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±1 minute\/month at 25°C (77°F)\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e OM-CP-IFC400 or OM-CP-IFC406 USB docking station required; 125,000 baud\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 140°C (-40 to 284°F), 0 to 100% RH non-condensing, 0.002 to 60 psia\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e XP SP3\/Vista\/7 and 8 (32-bit and 64-bit)\u003cbr\u003e \u003cb\u003eIP Rating:\u003c\/b\u003e IP40-logger alone (with no probe connected); the logger will inherit IP rating of the attached probe (up to, and including IP68\/IP69K)\u003cbr\u003e \u003cb\u003eDimensions (Body):\u003c\/b\u003e 54.5 H x 24.6 mm dia (2.15 x 0.97')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 85 g (3.0 oz)\u003cbr\u003e \u003cb\u003eMaterials (Body):\u003c\/b\u003e 316 Stainless Steel \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817413353767,"sku":"OM-CP-HITEMP140-M12-Logger","price":2093.61,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817413386535,"sku":"OM-CP-HITEMP140-M12-Logger","price":2093.61,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-hitemp140-m12_l_xpy55t35l9zd3y2u.jpg?v=1741316886"},{"product_id":"rugged-submersible-thermocouple-recorder","title":"Rugged, Submersible Thermocouple Recorder","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The OM-CP-TCTEMP1000 is a rugged, waterproof, battery powered, thermocouple based temperature recorder. This is a stand-alone, compact, portable, easy to use device that will measure and record up to 16,383 measurements per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. Its real time clock ensures that all the data is time and date stamped. The device can be started and stopped directly from your computer and its small size allows it to fit almost anywhere. \u003cbr\u003e\u003cbr\u003e The OM-CP-TCTEMP1000 makes data retrieval quick and easy even from harsh environments. Simply plug it into an available COM port and our user-friendly software does the rest. The Windows software converts your PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can also be exported to a text or Microsoft Excel file. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e Internal Channel\u003cbr\u003e Temperature Range:\u003c\/b\u003e -40 to 80°C (-40 to 176°F)\u003cbr\u003e \u003cb\u003eTemperature Resolution:\u003c\/b\u003e 0.1°C\u003cbr\u003e \u003cb\u003eTemperature Accuracy:\u003c\/b\u003e ±0.5°C (0 to 50°C)\u003cbr\u003e \u003cb\u003eRemote Channel Thermocouple Types: \u003c\/b\u003e\u003cbr\u003eJ, K, T, E, R, S, B, N (36' Type K T\/C supplied with unit), other\u003cbr\u003e T\/C’s available, contact the Data Aquisition Department\u003cbr\u003e \u003cb\u003eThermocouple Connection:\u003c\/b\u003e Female subminiature (SMP)\u003cbr\u003e \u003cb\u003eCold Junction Compensation:\u003c\/b\u003e Automatic based on internal channel\u003cbr\u003e \u003cb\u003eStart Time:\u003c\/b\u003e Software programamble start time and date,\u003cbr\u003e up to six months in advance\u003cbr\u003e \u003cb\u003eReal Time Recording:\u003c\/b\u003e May be used with PC to\u003cbr\u003e monitor and record data in real time\u003cbr\u003e \u003cb\u003eMemory: \u003c\/b\u003e16,383 readings per channel\u003cbr\u003e \u003cb\u003eReading Interval:\u003c\/b\u003e 1 reading every\u003cbr\u003e 2 seconds to 1 every 12 hours\u003cbr\u003e \u003cb\u003eCalibration Date:\u003c\/b\u003e Digital calibration through software\u003cbr\u003e \u003cb\u003eData Format:\u003c\/b\u003e Date and time stamped, °C, °F, K, °R, mV\u003cbr\u003e \u003cb\u003eTime Accuracy:\u003c\/b\u003e ±1 minute\/month at 20°C, RS-232 port not in use\u003cbr\u003e \u003cb\u003eComputer Interface:\u003c\/b\u003e PC serial or USB (interface cable required) 2400 baud\u003cbr\u003e \u003cb\u003ePower: \u003c\/b\u003e3.6 V lithium battery (included)\u003cbr\u003e \u003cb\u003eBattery Life:\u003c\/b\u003e 1 year typical (1 minute reading rate @ 25°C)\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e XP SP3\/Vista 7 and 8 (32-bit and 64-bit)\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 80°C (-40 to 176°F)\u003cbr\u003e 0 to 100% RH non-condensing\u003cbr\u003e \u003cb\u003eSubmersible: \u003c\/b\u003eUp to 45 m (150')\u003cbr\u003e \u003cb\u003eDimensions: \u003c\/b\u003e31 mm dia x 188 mm L (1.2 x 7.4')\u003cbr\u003e \u003cb\u003eWeight: \u003c\/b\u003e380 g (13 oz) \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49817413779751,"sku":"OM-CP-TCTEMP1000-Logger","price":816.1,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49817413812519,"sku":"OM-CP-TCTEMP1000-Logger","price":816.1,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/om-cp-tctemp1000_l_gwdx9vxkbv7wdn4n.jpg?v=1741316910"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/collections\/RDXL6SD_l.jpg?v=1741241115","url":"https:\/\/hkcalibrations.com.au\/collections\/temperature-and-humidity-data-loggers.oembed?page=6","provider":"hkcalibrations","version":"1.0","type":"link"}