{"title":"Head Mount Signal Conditioners","description":" Head Mount Signal Conditioners are used in a variety of industrial, commercial, and laboratory applications.  They are designed to convert and condition electrical signals from a variety of sensors, such as thermocouples, RTDs, Ohms, Potentiometers, and mV signals.Omega Engineering offers a wide range of Head Mount Signal Conditioners, which can be easily configured and scaled to meet any kind of specification.  Our conditioners feature a variety of convenient features such as pushbutton configuration, LED displays, SSR output, and user trim. These sensors are small sized and offered in a variety of input and transmission options.","products":[{"product_id":"rtd-head-mount-temperature-transmitter-w-user-trim","title":"RTD Head Mount Temperature Transmitter w\/ User Trim","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The TX12 head mounted temperature transmitter connects to any standard pt100 resistance sensor and converts the linearized temperature to a 4 to 20 mA signal. The transmitter is a two wire device, and is fully configurable by the user, over a wide temperature range, with the aid of a simple push button. This new TX12 design incorporates additional configuration menus, allowing the user to push button trim the transmitter output at both zero and span, ideal for trimming out sensor errors. The transmitters advanced circuitry guaranties high stability over the wide operating ambient temperature ranges experienced by head mounted devices. One of the transmitters features is the program LED, which provides visual indication of sensor fault when in normal operation and is also used to guide the operator through the simple menus during configuration.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSensor Type:\u003c\/b\u003e Pt100 100 Ω @ 0°C 2 or 3 Wire\u003cbr\u003e \u003cb\u003eSensor Range:\u003c\/b\u003e -200 to 850°C (-328 to 1562°F)\u003cbr\u003e \u003cb\u003eSensor Connection:\u003c\/b\u003e Screw terminal\u003cbr\u003e \u003cb\u003eMinimum Span:\u003c\/b\u003e 25°C (77°F)\u003cbr\u003e \u003cb\u003eLinearisation:\u003c\/b\u003e BS EN 60751(IEC 751) standard\/JISC 1604\u003cbr\u003e \u003cb\u003eMeasurement Accuracy:\u003c\/b\u003e 0.1°C ±0.05% of reading\u003cbr\u003e \u003cb\u003eThermal Drift:\u003c\/b\u003e 25 ppm\/°C\u003cbr\u003e \u003cb\u003eExcitation Current:\u003c\/b\u003e \u0026lt;200 uA\u003cbr\u003e \u003cb\u003eLead Resistance Effect:\u003c\/b\u003e 0.002°C\/Ω\u003cbr\u003e \u003cb\u003eMaximum Lead Resistance:\u003c\/b\u003e 20 Ω per leg\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOutput\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOutput Type:\u003c\/b\u003e 2 wire, 4 to 20 mA current loop\u003cbr\u003e \u003cb\u003eOutput Range:\u003c\/b\u003e (4.0 to 20.0) mA\u003cbr\u003e \u003cb\u003eOutput Connection:\u003c\/b\u003e Screw terminal\u003cbr\u003e \u003cb\u003eMaximum Output:\u003c\/b\u003e 21.5 mA (in high burnout condition)\u003cbr\u003e \u003cb\u003eMinimum Output:\u003c\/b\u003e 3.8 mA (in low burnout condition)\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e (mA output \/2000) or 5 uA (whichever is the greater)\u003cbr\u003e \u003cb\u003eLoop Voltage Effect:\u003c\/b\u003e 0.2 uA\/V\u003cbr\u003e \u003cb\u003eThermal Drift:\u003c\/b\u003e 1 uA \/°C\u003cbr\u003e \u003cb\u003eMaximum Output Load:\u003c\/b\u003e [(Vsupply-10)\/20]K Ω\u003cbr\u003e \u003cb\u003e(Example:\u003c\/b\u003e 700 Ω @ 24V)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGeneral Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eUpdate Time:\u003c\/b\u003e 500 mS\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e 1 second\u003cbr\u003e \u003cb\u003eStart Up Time:\u003c\/b\u003e 4 seconds (I out \u0026lt; 4 mA during start up)\u003cbr\u003e \u003cb\u003eWarm-Up Time:\u003c\/b\u003e 1 minute to full accuracy\u003cbr\u003e \u003cb\u003ePower Supply:\u003c\/b\u003e 10 to 30 Vdc\u003cbr\u003e\u003cbr\u003e \u003cb\u003eEnvironmental\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eAmbient Operating Range:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eAmbient Storage Temperature:\u003c\/b\u003e -50 to 90°C (-58 to 194°F)\u003cbr\u003e \u003cb\u003eAmbient Humidity Range:\u003c\/b\u003e 10 to 90% RH non condensing\u003cbr\u003e\u003cbr\u003e \u003cb\u003ePhysical\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 43 diameter; 21 mm height (1.7; 0.8\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 31 g (0.068 lb) (encapsulated)\u003cbr\u003e \u003cb\u003eApprovals\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEMC - BS EN 61326 :\u003c\/b\u003e1998: Electrical equipment for measurement control and laboratory use\u003cbr\u003e \u003cb\u003eANNEX A:\u003c\/b\u003e Immunity test requirements for equipment intended for use in industrial locations\u003cbr\u003e \u003cb\u003eANNEX F:\u003c\/b\u003e Test configurations, operational conditions and performance criteria for transducers with integrated or remote signal conditioning\u003cbr\u003e \u003cb\u003eIEC 61000-4-2:\u003c\/b\u003e Electrostatic discharge\u003cbr\u003e \u003cb\u003eIEC 61000-4-3:\u003c\/b\u003e EM field\u003cbr\u003e \u003cb\u003eIEC 61000-4-4:\u003c\/b\u003e Transient burst (output)\u003cbr\u003e \u003cb\u003eIEC 61000-4-5:\u003c\/b\u003e Surge (output)\u003cbr\u003e \u003cb\u003eNote:\u003c\/b\u003e Sensor input wires to be less than 3 m to comply. \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818449379623,"sku":"TX12-Head-Mnt-Temp-Tx","price":342.62,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818449412391,"sku":"TX12-Head-Mnt-Temp-Tx","price":342.62,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx12_l_uo7yrgzy54larqdf.jpg?v=1741346152"},{"product_id":"miniature-head-mount-temperature-transmitters","title":"Miniature Head Mount Temperature Transmitters","description":"\u003cp\u003eThese miniature head-mount temperature transmitters are designed for precise temperature measurement and signal conversion in confined spaces. Their compact size allows for installation in tight or limited-access areas, while their robust construction ensures durability in industrial environments. The transmitters offer high accuracy and are compatible with various temperature sensors, providing flexibility for different applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eCompact size for installation in confined spaces\u003c\/p\u003e\n\n\u003cp\u003eHigh accuracy for precise temperature measurement\u003c\/p\u003e\n\n\u003cp\u003eRobust construction for durability in industrial environments\u003c\/p\u003e\n\n\u003cp\u003eCompatible with various temperature sensors\u003c\/p\u003e\n\n\u003cp\u003eSuitable for a wide range of applications\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818449936679,"sku":"TX93-94-95-Series-Tx","price":682.17,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818449969447,"sku":"TX93-94-95-Series-Tx","price":682.17,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx93_94_95_l_kaqjpaux6mby0tga.jpg?v=1741346174"},{"product_id":"thermocouple-input-temperature-transmitter-w-pushbutton-config","title":"Thermocouple Input Temperature Transmitter w\/ Pushbutton Config","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\n\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eThe TX13 in-head mounting thermocouple transmitter converts a thermocouple input over a configured range to a standard industrial (4 to 20 mA) transmission signal. A simple push button operation allows the user to select thermocouple type, burnout direction, select fixed ranges and trim 4 and 20 mA points. The in-head transmitter incorporates the latest digital technology to ensure accurate drift-free performance.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eThe default factory scaling is for a range of 0 to 1000°C and Type K thermocouple input, with up-scale burnout. \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\u003cdiv class=\"tableWrapPP\" style=\"width: auto; overflow: auto hidden; color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e\u003ctable border=\"0\" cellspacing=\"8\" width=\"100%\" style=\"font-size: 8pt; color: #000000;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003ctable border=\"1\" cellpadding=\"4\" style=\"font-size: 8pt; color: #000000; text-align: center;\"\u003e\n\u003ccaption\u003e\u003cb\u003eAccuracy @ 20°C\u003c\/b\u003e\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr style=\"color: white;\" bgcolor=\"#6697CC\"\u003e\n\u003cth\u003eSensor\u003c\/th\u003e\n\u003cth\u003eRange °C\u003c\/th\u003e\n\u003cth\u003eInput Accuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eK\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 1370\u003c\/td\u003e\n\u003ctd rowspan=\"5\"\u003e±(0.5°C + 0.1% of F.S.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eJ\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-100 to 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eE\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eN\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-180 to 1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eT\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eR\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 1760\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e±(0.5°C + 0.1% of F.S.) over the range 800 to 1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eS\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 1760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003emV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 70mV\u003c\/td\u003e\n\u003ctd\u003e±0.02% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eIsolation:\u003c\/b\u003e Tested to 250 Vdc \u003cbr\u003e\u003cb\u003eSensor Burnout:\u003c\/b\u003e Either up or down scale output \u003cbr\u003e\u003cb\u003eCold Junction:\u003c\/b\u003e \u003cbr\u003e    \u003cb\u003eRange:\u003c\/b\u003e -40 to 85°C \u003cbr\u003e    \u003cb\u003eAccuracy:\u003c\/b\u003e ±0.5°C \u003cbr\u003e    \u003cb\u003eTracking:\u003c\/b\u003e ±0.05°C\/°C \u003cbr\u003e\u003cb\u003eStability:\u003c\/b\u003e \u003cbr\u003e    \u003cb\u003eOffset:\u003c\/b\u003e 0.1°C\/°C \u003cbr\u003e    \u003cb\u003eSpan:\u003c\/b\u003e 0.05°C\/°C \u003cbr\u003e  \u003cbr\u003e\u003cb\u003eOutput Type:\u003c\/b\u003e 2 wire, 4 to 20 mA sink \u003cbr\u003e\u003cb\u003eOutput Connection:\u003c\/b\u003e Screw terminal \u003cbr\u003e\u003cb\u003eMaximum Output:\u003c\/b\u003e 21.5 mA (in high burnout condition) \u003cbr\u003e\u003cb\u003eMinimum Output:\u003c\/b\u003e 3.8 mA (in low burnout condition) \u003cbr\u003e\u003cb\u003eAccuracy:\u003c\/b\u003e (mA out\/2000) or 5 uA (whichever is the greater) \u003cbr\u003e\u003cb\u003eLoop Voltage Effect:\u003c\/b\u003e 0.2 uA\/V \u003cbr\u003e\u003cb\u003eThermal Drift (from 20°C):\u003c\/b\u003e ±1 uA\/°C typical; ±1.5 uA max \u003cbr\u003e\u003cb\u003eMaximum Output Load:\u003c\/b\u003e [(Vsupply-10)\/20]KΩ (Example: 700Ω @ 24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eEnvironmental\u003c\/b\u003e \u003cbr\u003e\u003cb\u003eAmbient Operating Range:\u003c\/b\u003e -40 to 85°C \u003cbr\u003e\u003cb\u003eAmbient Storage Temperature:\u003c\/b\u003e -50 to 90°C \u003cbr\u003e\u003cb\u003eAmbient Humidity Range:\u003c\/b\u003e 10 to 90% RH non condensing \u003cbr\u003e\u003cb\u003ePhysical Dimensions:\u003c\/b\u003e 43 mm Dia; 21 mm H \u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 31 g (encapsulated)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eUpdate Time:\u003c\/b\u003e 500 mS \u003cbr\u003e\u003cb\u003eResponse Time:\u003c\/b\u003e 1 second to 90% of final value \u003cbr\u003e\u003cb\u003eStart Up Time:\u003c\/b\u003e Typically 5 seconds from power up \u003cbr\u003e\u003cb\u003eWarm-Up Time:\u003c\/b\u003e 1 minute to full accuracy \u003cbr\u003e\u003cb\u003ePower Supply:\u003c\/b\u003e 10 to 30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818450526503,"sku":"TX13-Smart-Temp-Tx","price":394.83,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818450559271,"sku":"TX13-Smart-Temp-Tx","price":394.83,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx13_l_tldymkht9upa0c6l.jpg?v=1741346199"},{"product_id":"loop-powered-thermistor-head-mount-transmitter-w-4-20ma-output","title":"Loop Powered Thermistor Head Mount Transmitter w\/ 4-20mA Output","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   The TX206TH is a cost effective “smart” in head transmitter that accepts thermistor temperature sensors and converts sensor output over a configured range to a standard industrial (4 to 20) mA transmission signal.\u003cbr\u003e\u003cbr\u003e A variety of thermistor types are available when using the configuration software: select thermistor type, temperature range, units and burnout direction, without requiring calibration equipment.\u003cbr\u003e\u003cbr\u003e PC configuration is performed quickly using our new USB port driven configurator by simply connecting two clips to the TX206TH loop terminals and following the software instructions. Calibration set-up may be saved as a file on the PC for later use.\u003cbr\u003e\u003cbr\u003e Alternatively, a single pushbutton and LED indicator allows the user to configure transmitter range against a manually set input condition. A red LED is included to help guide the user. The LED also operates as a sensor error indicator.\u003cbr\u003e\u003cbr\u003e Transmitters can be factory configured for any range specified at the time of order, removing the need for user configuration. Extra lead time is required. \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818450657575,"sku":"TX206TH-Thermistor-Tx","price":297.12,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818450690343,"sku":"TX206TH-Thermistor-Tx","price":297.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx206th_l_ges4hpndfwiwyok2.jpg?v=1741346221"},{"product_id":"2-wire-programmable-transmitter-with-universal-input","title":"2-Wire Programmable Transmitter with Universal Input","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e \u003cb\u003eApplication\u003c\/b\u003e\u003cbr\u003e • Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor.\u003cbr\u003e • Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors.\u003cbr\u003e • Amplification of a bipolar mV signal to a standard 4 to 20 mA current signal.\u003cbr\u003e \u003cb\u003eTechnical Characteristics\u003c\/b\u003e\u003cbr\u003e • Within a few seconds the user can program PR5331A to measure temperatures within all ranges defined by the norms.\u003cbr\u003e • The RTD and resistance inputs have cable compensation for 2\/3 and 4-wire connection.\u003cbr\u003e • A continuous check of vital stored data for safety reasons.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e \u003cb\u003eEnvironmental Conditions\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -40 to 85°C\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e\u0026lt; 95% RH (non-cond.)\u003cbr\u003e \u003cb\u003eProtection Degree (encl.\/terminal):\u003c\/b\u003e P68\/IP00\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMechanical Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e Ø 44 x 20.2 mm\u003cbr\u003e \u003cb\u003eWeight Approx:\u003c\/b\u003e 50 g\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 1 x 1.5 mm\u003csup\u003e2\u003c\/sup\u003e stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.4 Nm\u003cbr\u003e \u003cb\u003eVibration:\u003c\/b\u003e IEC 60068-2-6\u003cbr\u003e \u003cb\u003e2 to 25 Hz:\u003c\/b\u003e ±1.6 mm\u003cbr\u003e \u003cb\u003e25 to 100 Hz:\u003c\/b\u003e ±4 g\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCommon Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 7.2 to 35 Vdc\u003cbr\u003e \u003cb\u003eInternal Power Dissipation:\u003c\/b\u003e 25 mW to 0.8 W\u003cbr\u003e \u003cb\u003eIsolation Voltage\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eIsolation Voltage, Test\/Working:\u003c\/b\u003e 1.5 kVAC\/50 Vac\u003cbr\u003e \u003cb\u003eResponse Time\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eResponse Time (Programmable):\u003c\/b\u003e 1...60 s\u003cbr\u003e \u003cb\u003eVoltage Drop:\u003c\/b\u003e 7.2 Vdc\u003cbr\u003e \u003cb\u003eWarm-Up Time:\u003c\/b\u003e 5 min.\u003cbr\u003e \u003cb\u003eProgramming:\u003c\/b\u003e Loop Link\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e Min. 60 dB\u003cbr\u003e \u003cb\u003eEEprom Error Check:\u003c\/b\u003e\u0026lt; 3.5 s\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e Better than 0.05% of selected range\u003cbr\u003e \u003cb\u003eSignal Dynamics, Input:\u003c\/b\u003e 20 bit\u003cbr\u003e \u003cb\u003eSignal Dynamics, Output:\u003c\/b\u003e16 bit\u003cbr\u003e \u003cb\u003eEffect of Supply Voltage Change:\u003c\/b\u003e \u0026lt; 0.005% of span\/Vdc\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt; ±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity: NAMUR NE21, A Criterion, Burst:\u003c\/b\u003e \u0026lt; ±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eInput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCommon Input Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMax. Offset:\u003c\/b\u003e 50% of selected max. value\u003cbr\u003e \u003cb\u003eRTD input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRTD Type:\u003c\/b\u003ePt100, Ni100, lin. R\u003cbr\u003e \u003cb\u003eCable Resistance Per Wire:\u003c\/b\u003e5 Ω (max.)\u003cbr\u003e \u003cb\u003eSensor Current:\u003c\/b\u003e Nom. 0.2 mA\u003cbr\u003e \u003cb\u003eEffect of Sensor Cable Resistance (3\/4-wire):\u003c\/b\u003e\u0026lt; 0.002 Ω\/Ω\u003cbr\u003e \u003cb\u003eSensor Error Detection:\u003c\/b\u003eYes\u003cbr\u003e \u003cb\u003eLinear Resistance Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eLinear Resistance Min to Max:\u003c\/b\u003e0 to 5000 Ω\u003cbr\u003e \u003cb\u003eTC Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eThermocouple Type:\u003c\/b\u003e B, E, J, K, L, N, R, S, T, U, W3, W5, LR\u003cbr\u003e \u003cb\u003eCold Junction Compensation (CJC):\u003c\/b\u003e \u0026lt; ±1.0°C\u003cbr\u003e \u003cb\u003eSensor Error Detection:\u003c\/b\u003e Yes\u003cbr\u003e Sensor Error Current: When Detecting\/Else: Nom. 33 µA\/0 µA\u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e -12 to 800 mV\u003cbr\u003e \u003cb\u003eMin. Measurement Range (Span):\u003c\/b\u003e 5 mV\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e 10 MΩ\u003cbr\u003e \u003cb\u003eOutput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 4 to 20 mA\u003cbr\u003e \u003cb\u003eMin. Signal Range:\u003c\/b\u003e 16 mA\u003cbr\u003e \u003cb\u003eLoad (@ Current Output):\u003c\/b\u003e ≤ (Vsupply - 7.2)\/0.023 [Ω]\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤ 0.01% of span\/100 Ω\u003cbr\u003e \u003cb\u003eSensor Error Indication:\u003c\/b\u003e Programmable 3.5 to 23 mA\u003cbr\u003e \u003cb\u003eNAMUR NE43 Upscale\/Downscale:\u003c\/b\u003e 23 mA\/3.5 mA\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCommon Output Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eUpdating Time:\u003c\/b\u003e 440 ms\u003cbr\u003e \u003cb\u003eOf Span:\u003c\/b\u003e = of the presently selected range\u003cbr\u003e  \u003cb\u003eObserved Authority Requirements\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEMC:\u003c\/b\u003e 2014\/30\/EU\u003cbr\u003e \u003cb\u003eRoHS:\u003c\/b\u003e 2011\/65\/EU\u003cbr\u003e \u003cb\u003eEAC:\u003c\/b\u003e TR-CU 020\/2011\u003cbr\u003e\u003cbr\u003e \u003cb\u003eApprovals\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFM Certificate (TXUN-FM only):\u003c\/b\u003eFM17US0013X\u003cbr\u003e\u003cbr\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818450854183,"sku":"TXUN-ST-FM-Series-Tx","price":670.05,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818450886951,"sku":"TXUN-ST-FM-Series-Tx","price":670.05,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/txun-st-fm_m_7x36gqxzn19b4x0l.jpg?v=1741346244"},{"product_id":"head-mount-temperature-transmitters-with-rfid-communications","title":"Head Mount Temperature Transmitters with RFID Communications","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\"\u003e The TX401 and TX402 head mount temperature transmitters transform a temperature signal acquired from a Pt100, Pt1000 (TX401 only) or Ni100 RTD sensor or from a thermocouple (TX402 only) into a linearized 2-wire loop-powered 4 to 20 mA output. The characteristics of these converters ensure high precision on the reading scale with 16-bit conversion. The 4 to 20 mA output can be scaled based on the desired temperature input range.\u003cbr\u003e\u003cbr\u003e The programming procedure uses an RFID (NFC) mode with the dedicated TX400-RFID programmer that allows the user to make all calibrations and settings quickly and without the need to power and connect up the transmitter. Simply connect the TX400-RFID programmer to the USB port of your PC, start the RF Programmer configuration software and place the transmitter on top of the TX400-RFID programmer to establish communications.\u003cbr\u003e\u003cbr\u003e An additional programming tool is the Omega Brand Google App - \u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.omega.direct_link\" class=\"blLink\"\u003e \"Direct Link\" \u003c\/a\u003e relying on RFID\/NFC connectivity and allowing straightforward programming without wirings by Android devices.\u003cbr\u003e\u003cbr\u003e These temperature transmitters are also provided with a data logging function for the input signal. Transmitters have a non-volatile memory (circular buffer) for data-logging with user-selectable sampling time. The user selects the sampling time (1 to 3600 seconds) and then each time the 4 to 20 mA loop powers the device, the input value is stored to nonvolatile memory.\u003cbr\u003e\u003cbr\u003e Using the TX400-RFID programmer along with the RF Programmer configuration software (software is a free download from OMEGA) the user can:\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Completely configure the transmitter including scaling the 4 to 20 mA output to desired temperature input range\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Implement field calibration to compensate for gain and offset errors\u003cbr\u003e     \u003cb\u003e•\u003c\/b\u003e Download logged data to PC for visualization and printing\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRTD Input Types and Ranges:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eTX401, TX402:\u003c\/b\u003e Pt100 (a = 0.00385), 2, 3, or 4-wire connection: TX401: -200 to 800°C (-328 to 1472°F), TX402: -200 to 600°C (-328 to 1112°F)\u003cbr\u003e     \u003cb\u003eTX401 Only:\u003c\/b\u003e Pt1000 (a = 0.00385), 2-wire connection; -200 to 800°C (-328 to 1472°F)\u003cbr\u003e     \u003cb\u003eTX401, TX402:\u003c\/b\u003e Ni100 (a = 0.00618), 2, 3, or 4-wire connection: TX401: -50 to 170°C (-58 to 338°F), TX402: -60 to 180°C (-76 to 356°F)\u003cbr\u003e \u003cb\u003eThermocouple Input Types (TX402 Only):\u003c\/b\u003e J\/K\/T\/E\/R\/S\/B\/N\/mV\u003cbr\u003e \u003cb\u003eOutput Resolution:\u003c\/b\u003e 1 µA\u003cbr\u003e \u003cb\u003eOver-Range Output:\u003c\/b\u003e FS + 5°C\u003cbr\u003e \u003cb\u003eUnder-Range Output:\u003c\/b\u003e FS - 5°C\u003cbr\u003e \u003cb\u003eOutput Error (Failure):\u003c\/b\u003e Selectable: TX401: between 21.5 or 3.8 mA, TX402: between  21 or 3.8 mA\u003cbr\u003e \u003cb\u003eCurrent Output Protection:\u003c\/b\u003e 30 mA approx\u003cbr\u003e \u003cb\u003eRejection:\u003c\/b\u003e 50 to 60 Hz\u003cbr\u003e \u003cb\u003eMaximum Transmission Error:\u003c\/b\u003e 0.1% FS or 0.2°C whichever is greater\u003cbr\u003e \u003cb\u003eSampling Time:\u003c\/b\u003e 300 msec\u003cbr\u003e \u003cb\u003eResponse Time (10 to 90%):\u003c\/b\u003e 600 msec\u003cbr\u003e \u003cb\u003eNon-Volatile Memory (Circular Buffer) for Data Logging:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eTX401:\u003c\/b\u003e 3966 Data Points\u003cbr\u003e     \u003cb\u003eTX402:\u003c\/b\u003e 2546 Data Points\u003cbr\u003e \u003cb\u003eCable Resistance:\u003c\/b\u003e 20Ω max\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt;100 ppm\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 2-wire loop powered; operating range 6 to 32 Vdc\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eTX401:\u003c\/b\u003e Non-isolated\u003cbr\u003e     \u003cb\u003eTX402:\u003c\/b\u003e galvanic, 1 KVac input\/output\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 85°C (-40 to 185°F), 30 to 90% RH (non condensing)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eMounting:\u003c\/b\u003e DIN\/B head\u003cbr\u003e \u003cb\u003eEnclosure Material:\u003c\/b\u003e Nylon (PA66)\u003cbr\u003e \u003cb\u003eEnclosure Rating:\u003c\/b\u003e NEMA 1 (IP20) according to CE, EN 61000-6-4, EN 61000-6-2\u003cbr\u003e \u003cb\u003eProgramming:\u003c\/b\u003e Wireless with RFID technology (NFC)\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows® XP\/7\/8 (32-bit and 64-bit), Windows 10 (64-bit)\u003cbr\u003e \u003cb\u003eConnection:\u003c\/b\u003e Screw terminals\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 30 g (1.05 oz) approx\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 23 H x 45 mm dia (0.9 x 1.77\") \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818451149095,"sku":"TX400-Srs-RFID-Prog-Tx","price":212.75,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818451181863,"sku":"TX400-Srs-RFID-Prog-Tx","price":212.75,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx400-series_l_baey5uercg4wjklq.jpg?v=1741346267"},{"product_id":"programmable-head-mount-temperature-transmitter-for-thermocouples","title":"Programmable Head Mount Temperature Transmitter for Thermocouples","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\n\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eThe TX86 is a 2-wire Loop-Powered, Galvanic-Isolated, Programmable Universal Input Temperature Transmitter that is designed to be head-mounted, but can be standalone as well. It uses 16 bits A\/D and D\/A converters offering high accuracy with Linearized 4 to 20 mA or 20 to 4 mA outputs. Being a user-friendly rugged instrument, it displays the measured variable and has a SSR output. The TX86 has 3 push buttons on its front keyboard \u0026amp; a 4-digit 7-segment bright LED display module that indicates the values of the measured parameters during the Measuring Mode while also providing prompting and programming instructions during the setup and calibration mode routines. The 1000V AC galvanic isolation removes all ground loop effects. Three different engineering units (°C, °F and %), can be displayed and the chosen unit is highlighted by an associated LED lamp when in the measuring mode.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eSPECIFICATIONS\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e\u003c\/span\u003e\u003cdiv class=\"tableWrapPP\" style=\"width: auto; overflow: auto hidden; color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"5\" align=\"left\" style=\"font-size: 8pt; color: #000000; text-align: center; margin-right: 10px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"color: white;\" bgcolor=\"#6697CC\"\u003e\n\u003cth\u003eInput Sensors\u003c\/th\u003e\n\u003cth\u003eMeasured Range (°C)\u003c\/th\u003e\n\u003cth\u003eMinimum Span (°C)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e-100 to 1372\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e-100 to 750\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003e-100 to 400\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003e-100 to 750\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003e0 to 1700\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003e-100 to 1300\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003e0 to 1700\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e400 to 1800\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100PT\u003c\/td\u003e\n\u003ctd\u003e-200 to 850\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200PT\u003c\/td\u003e\n\u003ctd\u003e-200 to 500\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500PT\u003c\/td\u003e\n\u003ctd\u003e-200 to 200\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000PT\u003c\/td\u003e\n\u003ctd\u003e-200 to 200\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNi120\u003c\/td\u003e\n\u003ctd\u003e-80 to 260\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCu10\u003c\/td\u003e\n\u003ctd\u003e-100 to 260\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e0 to 2000Ω\u003c\/td\u003e\n\u003ctd\u003e50Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotentiometer\u003c\/td\u003e\n\u003ctd\u003e0 to 2000Ω\u003c\/td\u003e\n\u003ctd\u003e50Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (millivolts)\u003c\/td\u003e\n\u003ctd\u003e-5 to +60\u003c\/td\u003e\n\u003ctd\u003e2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eGeneral Performance:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e (@ 24 Vdc, 25°C ±2°C)\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eLoop Power:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 12 to 30 Vdc, LED indicator reverse polarity protected 60 Vdc\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eOutput:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 4\/20 mA calibrated; 3.8 to 20.5 mA linear\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eResolution:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 2uA\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eRTD Excitation Current:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 30\/150 uA ± 2%\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eInput Impedance:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 1 MΩ, nominal\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eMaximum Load:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 50 x (Vsupply – 12V) Ω\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eAccuracy:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e ± 0.2% of full scale input\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eLong-Term Stability:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e ± 0.15%\/ year\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eTemp. Coefficient:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e ± 0.01%\/°C (5 to 50°C)\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eDampening Constant:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e Programmable\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eConfiguration:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e Via 3 push-buttons on front\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eSolid State Relay Output:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 30 mA maximum\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eCold Junction Comp:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e ± 2°C max (5 to 50°C)\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003ePower Supply Effect:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e Less than 0.01%\/V\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eInput Protection:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 40 Vdc maximum\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eSensor Burnout:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e Upscale \u0026gt;21mA, downscale \u0026lt;3.8 mA\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eIsolation Rating:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 1000V RMS continuous\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eResponse Time:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 1 second with dampening off\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003ePower-on Response:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e Within 5 seconds\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eAmbient Temps:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e -20 to 70°C (-4 to 158°F) (storage and operation)\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eRelative Humidity:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 20 to 90%, non-condensing\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eDimensions:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 62 Dia x 42 mm H (2.5 x 1.7\")\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eMounting:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e Head-mounted\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eHousing:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e Plastic, polycarbonate\u003c\/span\u003e\u003cbr\u003e\u003cb style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003eWeight:\u003c\/b\u003e\u003cspan style=\"color: #5c5c5c; font-family: Verdana, Geneva, sans-serif; font-size: 13.3333px;\"\u003e 80 g (0.18 lb)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818451312935,"sku":"TX86-Transmitter","price":1719.83,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818451345703,"sku":"TX86-Transmitter","price":1719.83,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx86_l_j2hmkaz2edh7a4vi.jpg?v=1741346292"},{"product_id":"head-mount-thermocouple-transmitter-w-process-output","title":"Head Mount Thermocouple Transmitter w\/ Process Output","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\u003cspan class=\"descCopyPP\"\u003e \u003cb\u003e\u003cspan style=\"color: blue;\"\u003e Please check out our newer model 2-wire transmitter\u003ca href=\"https:\/\/www.omega.com\/en-us\/communication-and-connectivity\/signal-conditioners-and-transmitters\/signal-conditioners\/tx13-series\/p\/TX13\" class=\"blLink\"\u003e TX13 \u003c\/a\u003e Series with more advanced features at a lower price.\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e The Model TX31 is an analog, isolated 2-wire head-mounted temperature transmitter that converts thermocouple input to the voltage, which is generated by the thermocouple sensor, linear, and highly accurate 4 to 20 mA output current. \u003cbr\u003e\u003cbr\u003e The transmitter comes in a variety of applications such as process control, automation system, and energy source management. The TX31 is performed by means of a DIP-switch array for coarse range setting, and 2 multi-turn potentiometers (ZERO and SPAN) which are used for the final finetuning. \u003cbr\u003e\u003cbr\u003e The TX31 is housed in a metal enclosure with a plastic top cover, fitting into DIN B connection heads, providing excellent RFI immunity. The TX31 accepts low level signal from the thermocouple, filtered, amplified, and converter process current to reduce susceptibility transients and noise operations while allowing the same 2 wires to carry the transmitter power and output current signal simultaneously. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications (V\u003csub\u003eLOOP\u003c\/sub\u003e = 24 VDC, T\u003csub\u003eAMB\u003c\/sub\u003e =23±2°C, R\u003csub\u003eLOAD\u003c\/sub\u003e = 250 Ω)\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOutput:\u003c\/b\u003e 4 to 20 mA; Upscale \u0026lt; 26 mA, Downscale \u0026lt;3.8 mA\u003cbr\u003e \u003cb\u003eLoop Power:\u003c\/b\u003e 12 to 32 Vdc; Reverse polarity protected\u003cbr\u003e \u003cb\u003eInput Thermocouple:\u003c\/b\u003eTypes J, K, E, T, R, S, or B\u003cbr\u003e \u003cb\u003eSupply Voltage Effect:\u003c\/b\u003e ±0.01%\/V\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e ±0.02% \/°C (Tamb = 5 to 50°C )\u003cbr\u003e \u003cb\u003eRepeatability:\u003c\/b\u003e ±0.01% of voltage input span\u003cbr\u003e \u003cb\u003eLinearity Error:\u003c\/b\u003e ±0.1% of voltage input span (not temperature input)\u003cbr\u003e \u003cb\u003eGalvanic Isolation:\u003c\/b\u003e Input\/output 1000 Vrms, continuous\u003cbr\u003e \u003cb\u003eCold-Junction Compensation:\u003c\/b\u003e ±2°C max (T\u003csub\u003eamb\u003c\/sub\u003e = 5 to 50°C)\u003cbr\u003e \u003cb\u003eLoad Capability:\u003c\/b\u003e 50 x (loop power - 12) Fine Adjustment: 5% of zero \u0026amp; span\u003cbr\u003e \u003cb\u003eRFI effect (5W, 470 MHz):\u003c\/b\u003e \u0026lt; ±10% of span\u003cbr\u003e \u003cb\u003eResponse time (0 to 90%):\u003c\/b\u003e 200 ms\u003cbr\u003e \u003cb\u003eHousing Material:\u003c\/b\u003e Cast aluminum with epoxy coating and polycarbonate, UL94-V0 grade\u003cbr\u003e \u003cb\u003eConnection:\u003c\/b\u003e M3, nickel coated brass; 22 - 12 AWG\u003cbr\u003e \u003cb\u003eOperation Environment:\u003c\/b\u003e -20 to 70°C; 5 to 85 %, non-condensing\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 27 H x 45 mm Dia. (1.06 x 1.77\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 65 g (2.3 oz) \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818451509543,"sku":"TX31-Series-TC-Tx","price":914.03,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818451542311,"sku":"TX31-Series-TC-Tx","price":914.03,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx31_l_so1e7fszwi1i1mgb.jpg?v=1741346314"},{"product_id":"communication-tool-for-txun-series-and-drst-fr","title":"Communication Tool for TXUN Series and DRST-FR","description":"\u003cp\u003eThe Communication Tool for TXUN Series and DRST FR is a specialized device designed to facilitate communication and configuration of TXUN series transmitters and DRST FR controllers. This tool enables users to easily set parameters, calibrate devices, and troubleshoot issues, ensuring optimal performance and integration into control systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eDevice Configuration: Allows for easy parameter setting and calibration.\u003c\/p\u003e\n\n\u003cp\u003eTroubleshooting: Facilitates diagnostics and troubleshooting of connected devices.\u003c\/p\u003e\n\n\u003cp\u003eUser-Friendly Interface: Intuitive design for ease of use.\u003c\/p\u003e\n\n\u003cp\u003eCompatibility: Specifically designed for TXUN series transmitters and DRST FR controllers.\u003c\/p\u003e\n\n\u003cp\u003eEnhanced Performance: Ensures optimal operation and integration into control systems.\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818451706151,"sku":"TXUN-KIT-Config-Kit","price":831.56,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818451738919,"sku":"TXUN-KIT-Config-Kit","price":831.56,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/txun-kit_l_thgztwzozqte0rsj.jpg?v=1741346337"},{"product_id":"head-mount-temperature-transmitters-fm-approved","title":"Head Mount Temperature Transmitters | FM Approved","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\u003cspan class=\"descCopyPP\"\u003e \u003cb\u003e\u003cspan style=\"color: blue;\"\u003e Please check out our newer model 2-wire transmitter \u003ca href=\"https:\/\/www.omega.com\/en-us\/communication-and-connectivity\/signal-conditioners-and-transmitters\/signal-conditioners\/tx13-series\/p\/TX13\" class=\"blLink\"\u003e TX13 \u003c\/a\u003e Series (TC) and \u003ca href=\"https:\/\/www.omega.com\/en-us\/communication-and-connectivity\/signal-conditioners-and-transmitters\/signal-conditioners\/tx12-series\/p\/TX12\" class=\"blLink\"\u003e TX12 \u003c\/a\u003e Series (RTD) with more advanced features at a lower price.\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e The economical OMEGA™ TX91 and TX92 two-wire transmitters provide an output current of 4-20 mA proportional to the mV signal of a thermocouple or to a two- or three-wire RTD sensor input.\u003cbr\u003e\u003cbr\u003eThe TX91 or TX92 is very compact and can mount directly within OMEGA’s NB1 cast iron protection head. By having the transmitter near the sensor, the effects of electrical noise can be minimized and long runs of thermocouple wire can be eliminated.\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"5\" bordercolor=\"#000000\"\u003e\u003ctbody\u003e\n\u003ctr style=\"color: white;\" bgcolor=\"#3D986C\"\u003e\n\u003cth colspan=\"4\"\u003eTX91\u003c\/th\u003e \u003cth\u003eTX92\u003c\/th\u003e \u003cth rowspan=\"2\"\u003eRange °C (°F)\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr style=\"color: white;\" bgcolor=\"#3D986C\"\u003e\n\u003cth\u003eJ\u003c\/th\u003e \u003cth\u003eK\u003c\/th\u003e \u003cth\u003eT\u003c\/th\u003e \u003cth\u003eE\u003c\/th\u003e \u003cth\u003eRTD\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd colspan=\"4\" align=\"center\"\u003eN\/A\u003c\/td\u003e \u003ctd align=\"center\"\u003e1\u003c\/td\u003e \u003ctd align=\"center\"\u003e-40 to 49 (-40 to 120)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003eJ2\u003c\/td\u003e \u003ctd align=\"center\"\u003eK2\u003c\/td\u003e \u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003eT2\u003c\/td\u003e \u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003eE2\u003c\/td\u003e \u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003e2\u003c\/td\u003e \u003ctd align=\"center\"\u003e-18 to 93 (0 to 200)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003eJ3\u003c\/td\u003e \u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003eK3\u003c\/td\u003e \u003ctd align=\"center\"\u003eT3\u003c\/td\u003e \u003ctd align=\"center\"\u003eE3\u003c\/td\u003e \u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003e3\u003c\/td\u003e \u003ctd align=\"center\"\u003e-18 to 149 (0 to 300)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\"\u003eJ4\u003c\/td\u003e \u003ctd align=\"center\"\u003eK4\u003c\/td\u003e \u003ctd align=\"center\"\u003eT4\u003c\/td\u003e \u003ctd align=\"center\"\u003eE4\u003c\/td\u003e \u003ctd align=\"center\"\u003e4\u003c\/td\u003e \u003ctd align=\"center\"\u003e-18 to 260 (0 to 500)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\"\u003eJ5\u003c\/td\u003e \u003ctd align=\"center\"\u003eK5\u003c\/td\u003e \u003ctd rowspan=\"2\" align=\"center\"\u003eN\/A\u003c\/td\u003e \u003ctd align=\"center\"\u003eE5\u003c\/td\u003e \u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003e5\u003c\/td\u003e \u003ctd align=\"center\"\u003e-18 to 399 (0 to 750)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\"\u003eJ6\u003c\/td\u003e \u003ctd align=\"center\" bgcolor=\"#C2CCD9\"\u003eK6\u003c\/td\u003e \u003ctd align=\"center\"\u003eE6\u003c\/td\u003e \u003ctd align=\"center\"\u003e6\u003c\/td\u003e \u003ctd align=\"center\"\u003e-18 to 538 (0 to 1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOutput Range:\u003c\/b\u003e 4 to 20 mA DC Zero and Span Adjustment Range: ±25%\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e ±0.1% FS (includes effects of linearity, hysteresis and repeatability) referenced to the mV input\u003cbr\u003e \u003cb\u003eAmbient Temperature Range:\u003c\/b\u003e -32 to 85°C (-25 to 185°F)\u003cbr\u003e \u003cb\u003eStorage Temperature Range:\u003c\/b\u003e -65 to 90°C (-85 to 19°F)\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 11 to 44 Vdc; 24 Vdc recommended\u003cbr\u003e \u003cb\u003eMax Loop Resistance:\u003c\/b\u003e (V\u003csub\u003es\u003c\/sub\u003e - 11 V)\/0.020A\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 29 H x 45 mm D (1.125 x 1.75\") (height includes terminal strip)\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 50 g (1.5 oz) \u003cbr\u003e\u003cbr\u003e\u003cb\u003eExamples of pricing for popular models is referenced in the \"To Order\" box. Use the \"Part Number Builder\" below to get pricing for all available models.\u003c\/b\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818451837223,"sku":"TX91-92-Srs-Transmitters","price":1620.72,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818451869991,"sku":"TX91-92-Srs-Transmitters","price":1620.72,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx91_92_l_pbeg2kevlijl6rxs.jpg?v=1741346360"},{"product_id":"2-wire-transmitter-w-hart-protocol-enabled-2-analog-inputs","title":"2-Wire Transmitter w\/ Hart Protocol Enabled | 2 Analog Inputs","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e \u003cb\u003eApplication\u003c\/b\u003e\u003cbr\u003e • Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.\u003cbr\u003e • HART communication and 4 to 20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.\u003cbr\u003e • Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.\u003cbr\u003e • Amplification of bipolar mV signals to standard 4 to 20 mA current signals.\u003cbr\u003e • Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.\u003cbr\u003e \u003cb\u003eTechnical Characteristics\u003c\/b\u003e\u003cbr\u003e •  HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.\u003cbr\u003e • The HART 7 protocol offers:\u003cbr\u003e      • Long Tag numbers of up to 32 characters.\u003cbr\u003e      • Enhanced Burst Mode and Event notification with time stamping.\u003cbr\u003e      • Device variable and status mapping to any dynamic variable PV, SV, TV or QV.\u003cbr\u003e      • Process signal trend measurement with logs and summary data.\u003cbr\u003e      • Automatic event notification with time stamps.\u003cbr\u003e      • Command aggregation for higher communication efficiency.\u003cbr\u003e      • TXUN-HT is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.\u003cbr\u003e      • Continuous check of vital stored data. Meeting the NAMUR NE 21 recommendations, the TXUN-HT HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the TXUN-HT meets NAMUR NE43 and NE89 recommendations.\u003cbr\u003e \u003cb\u003eMounting\/Installation\u003c\/b\u003e\u003cbr\u003e • For DIN form B sensor head mounting.\u003cbr\u003e • Configuration via TXUN-KIT for standard set up or via HART programming unit for Hart Communication set up. See links in Notes.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEnvironmental Conditions\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e-40 to 85°C\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e \u0026lt; 95% RH (non-cond.)\u003cbr\u003e \u003cb\u003eProtection Degree (encl.\/terminal):\u003c\/b\u003e IP68\/IP00\u003cbr\u003e \u003cb\u003eMechanical Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e Ø 44 x 20.2 mm\u003cbr\u003e \u003cb\u003eWeight Approx:\u003c\/b\u003e 50 g\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 1 x 1.5 mm\u003csup\u003e2\u003c\/sup\u003e stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.4 Nm\u003cbr\u003e \u003cb\u003eVibration:\u003c\/b\u003eIEC 60068-2-6\u003cbr\u003e \u003cb\u003e2 to 25 Hz:\u003c\/b\u003e ±1.6 mm\u003cbr\u003e \u003cb\u003e25 to 100 Hz:\u003c\/b\u003e ±4 g\u003cbr\u003e \u003cb\u003eCommon Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 8.0 to 30 Vdc\u003cbr\u003e \u003cb\u003eIsolation Voltage\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eIsolation Voltage, Test\/Working:\u003c\/b\u003e 1.5 kVAC\/50 Vac\u003cbr\u003e \u003cb\u003eResponse Time\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eResponse Time (Programmable):\u003c\/b\u003e 1 to 60 s\u003cbr\u003e \u003cb\u003eVoltage Drop:\u003c\/b\u003e 8.0 Vdc\u003cbr\u003e \u003cb\u003eProgramming:\u003c\/b\u003e Loop Link and HART\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt; 60 dB\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e Better than 0.05% of selected range\u003cbr\u003e \u003cb\u003eSignal Dynamics, Input:,\u003c\/b\u003e 22 bit\u003cbr\u003e \u003cb\u003eSignal Dynamics, Output:\u003c\/b\u003e 16 bit\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt; ±0.1% of span\u003cbr\u003e \u003cb\u003eExtended EMC immunity: NAMUR NE21, A Criterion, Burst:\u003c\/b\u003e \u0026lt; ±1% of span\u003cbr\u003e \u003cb\u003eInput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCommon Input Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMax. Offset:\u003c\/b\u003e 50% of selected max. value\u003cbr\u003e \u003cb\u003eRTD Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRTD Type:\u003c\/b\u003e Pt50\/100\/200\/500\/1000 Ni50\/100\/120\/1000\u003cbr\u003e \u003cb\u003eCable Resistance per Wire:\u003c\/b\u003e 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)\u003cbr\u003e \u003cb\u003eSensor Current:\u003c\/b\u003e Nom. 0.2 mA\u003cbr\u003e \u003cb\u003eTC Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eThermocouple Type:\u003c\/b\u003e B, E, J, K, L, N, R, S, T, U, W3, W5, LR\u003cbr\u003e \u003cb\u003eCold junction compensation (CJC):\u003c\/b\u003e Constant, internal or external via a Pt100 or Ni100 sensor\u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e -800 to 800 mV\u003cbr\u003e \u003cb\u003eMin. Measurement Range (Span):\u003c\/b\u003e 2.5 mV\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e 10 MΩ\u003cbr\u003e \u003cb\u003eOutput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 4 to 20 mA\u003cbr\u003e \u003cb\u003eMin. Signal Range:\u003c\/b\u003e 16 mA\u003cbr\u003e \u003cb\u003eLoad (@ Current Output):\u003c\/b\u003e ≤ (Vsupply - 8)\/0.023 [Ω]\u003cbr\u003e \u003cb\u003eSensor Error Indication:\u003c\/b\u003e Programmable 3.5 to 23 mA\u003cbr\u003e \u003cb\u003eNAMUR NE43 Upscale\/Downscale:\u003c\/b\u003e 23 mA\/3.5 mA\u003cbr\u003e \u003cb\u003eCommon Output Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eUpdating Time:\u003c\/b\u003e 440 ms\u003cbr\u003e \u003cb\u003eHART Protocol Revisions:\u003c\/b\u003e HART 7 and HART 5\u003cbr\u003e \u003cb\u003eObserved Authority Requirements\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEMC:\u003c\/b\u003e 2014\/30\/EU\u003cbr\u003e \u003cb\u003eEAC:\u003c\/b\u003e TR-CU 020\/2011\u003cbr\u003e \u003cb\u003eApprovals\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eATEX 2014\/34\/EU:\u003c\/b\u003e KEMA 03ATEX1537\u003cbr\u003e \u003cb\u003eIECEx:\u003c\/b\u003e KEM 10.0083X\u003cbr\u003e \u003cb\u003eFM:\u003c\/b\u003e FM17US0013X\u003cbr\u003e \u003cb\u003eCSA:\u003c\/b\u003e 1125003\u003cbr\u003e \u003cb\u003eINMETRO:\u003c\/b\u003eNCC 12.0844 X\u003cbr\u003e \u003cb\u003eEAC Ex TR-CU 012\/2011:\u003c\/b\u003e RU C-DK.GB08.V.00410\u003cbr\u003e \u003cb\u003eDNV-GL Marine:\u003c\/b\u003e Stand. f. Certific. No. 2.4\u003cbr\u003e \u003cb\u003eSIL:\u003c\/b\u003e Hardware assessed for use in SIL applications \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818452066599,"sku":"TXUN-HT-Hart-Tx","price":1775.38,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818452099367,"sku":"TXUN-HT-Hart-Tx","price":1775.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/txun-ht_l_fbfnhfb5jzi7g2bu.jpg?v=1741346385"},{"product_id":"head-mount-r-and-s-type-tc-transmitter-w-4-20ma-output","title":"Head Mount R and S type TC Transmitter w\/ 4-20mA Output","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003cstrong\u003ePlease check out Newest Released 2-wire Transmitters with Standard, FM \u0026amp; Hart Models Available\u003ca class=\"blLink\" href=\"..\/p\/txun-st-fm-series-tx\"\u003e TXUN Series \u003c\/a\u003e for more advanced features and excellent usability.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eTX250 Series\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eThermocouple Input\u003c\/strong\u003e\u003cbr\u003e\nThe TX250 Series are non-isolated two-wire transmitter which convert the T\/C thermoelectric voltage into a standardized load-independent, 4 to 20 mA process current.\u003cbr\u003e\n\u003cbr\u003e\nThe TX250 Series are housed in metal enclosures and fit into NB1 connection heads. The transmitter’s enclosure provides excellent RFI immunity.\u003cbr\u003e\n\u003cbr\u003e\nThe transmitter calibration is set by six dip-switches located behind the top cover. There are three basic models which cover the various T\/C types. TX251 is for T\/C types K, T and J TX252 is for type E and TX253 is for type R and S.\u003cbr\u003e\n\u003cbr\u003e\nDip-switch arrays select the T\/C type, and set the \"Zero\" coarse level and the \"Span\" coarse range.\u003cbr\u003e\n\u003cbr\u003e\nZero and Span trimmers provide the fine tuning calibration.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eTX254 RTD Input\u003c\/strong\u003e\u003cbr\u003e\nThe TX254 is a non-isolated two-wire transmitter which converts the measuring signal of a 3 wire 100 ohm Pt RTD into a standardized load-independent, 4 to 20 mA current which is linearly proportional to the measured temperature.\u003cbr\u003e\n\u003cbr\u003e\nThe TX254 transmitter is provided with excellent lead resistance compensation and Pt-100 linearization conforming to BS1904 and DIN 43760 characteristics (a = 0.00385). The transmitter calibration is set by six dip-switches located behind the top cover.\u003cbr\u003e\n\u003cbr\u003e\nThree dip-switches set the lower measured coarse temperature and the other three dip-switches set the measured coarse temperature span.\u003cbr\u003e\n\u003cbr\u003e\nZero and Span trimmers provide the fine tuning calibration.\u003cbr\u003e\n \n\u003cdiv\u003e\n\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 4 to 20 mA, 28 mA limited\u003cbr\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 10 to 36 Vdc\u003cbr\u003e\n(24 Vdc recommended)\u003cbr\u003e\n\u003cstrong\u003eSupply Variation Effect:\u003c\/strong\u003e \u0026lt;0.001%\/1V change\u003cbr\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Better than 0.1% of span\u003cbr\u003e\n\u003cstrong\u003eLoad Resistance:\u003c\/strong\u003e Rmax () = (Vsupply - 10)\/.02\u003cbr\u003e\n\u003cstrong\u003eTemperature Stability:\u003c\/strong\u003e \u0026lt;0.01% of span\/1°C\u003cbr\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20 to 70°C (-4 to 158°F)\u003cbr\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% RH, non condensed\u003cbr\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Die-cast zinc alloy\u003cbr\u003e\n\u003cstrong\u003eMounting Holes:\u003c\/strong\u003e 5 mm ID suitable for 8-32 screw\u003cbr\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 44 Dia x 33 mm H (1.7 x 1.3\") including the terminal block.\u003cbr\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 50 g (1.5 oz)\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eTX250 Thermocouple Input Specifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eTX251:\u003c\/strong\u003e thermocouple type K, T, J\u003cbr\u003e\n\u003cstrong\u003eTX252:\u003c\/strong\u003e thermocouple type E\u003cbr\u003e\n\u003cstrong\u003eTX253:\u003c\/strong\u003e thermocouple type R, S\u003cbr\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Two \"Zero\" DIP switches, three \"Span\" DIP switches and two fine-tuning trimmers\u003cbr\u003e\n\u003cstrong\u003eCold Junction Error:\u003c\/strong\u003e ±0.9°C (1.6°F) typical (3°C [5.4°F] for R and S) for 0 to 60°C (32 to 140°F)\u003cbr\u003e\n\u003cstrong\u003eLinearity (refer to mV input):\u003c\/strong\u003e \u0026lt;0.08% of span\u003cbr\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Transmitters are linear to the mV input from the thermocouple, not to temperature.\u003cbr\u003e\n\u003cbr\u003e\n \u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eTX250 RTD Input Specifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e 3-wire Pt-100 according to BS 1904 and DIN 43760 characteristics\u003cbr\u003e\n\u003cstrong\u003eInput Span Range:\u003c\/strong\u003e 30 to 800°C\u003cbr\u003e\n\u003cstrong\u003eInput Zero Range:\u003c\/strong\u003e -50 to 200°C\u003cbr\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Three \"Zero\" DIP\u003cbr\u003e\nswitches, three \"Span\" DIP switches and two fine-tuning trimmers\u003cbr\u003e\n\u003cstrong\u003eSensor Lead Resistance:\u003c\/strong\u003e 50 maximum (two ways)\u003cbr\u003e\n\u003cstrong\u003eLead Compensation Error:\u003c\/strong\u003e \u0026lt;0.05°C\/10 lead resistance\u003cbr\u003e\n\u003cstrong\u003eSensor Excitation: \u003c\/strong\u003e\u0026lt;1 mA\u003cbr\u003e\n\u003cstrong\u003eLinearity: \u003c\/strong\u003eBetter than 0.08% of span\u003cbr\u003e\n \u003c\/div\u003e\n\n\u003cdiv\u003e \u003cstrong\u003eModel No\u003c\/strong\u003e.   \u003cstrong\u003eInput Type\u003c\/strong\u003e   \u003cstrong\u003eSpan Range*\u003c\/strong\u003e   \u003cstrong\u003eMinimum Span\u003c\/strong\u003e   \u003cstrong\u003eZero Offset Range\u003c\/strong\u003e  TX251 \u003cstrong\u003eJ\u003c\/strong\u003e -100 to 750°C 85°C -100 to 50°C -148 to 1380°F 155°F \u003cstrong\u003eK\u003c\/strong\u003e -100 to 1350°C 105°C -100 to 100°C -148 to 2440°F 190°F \u003cstrong\u003eT\u003c\/strong\u003e -100 to 400°C 100°C -100 to 100°C -148 to 750°F 180°F TX252 \u003cstrong\u003eE\u003c\/strong\u003e -100 to 1000°C 75°C -100 to 30°C -148 to 1832°F 135°F TX253 \u003cstrong\u003eR\u003c\/strong\u003e 0 to 1750°C 600°C 0 to 750°C 32 to 3180°F 1080°F \u003cstrong\u003eS\u003c\/strong\u003e 0 to 1750°C 600°C 0 to 750°C 32 to 3180°F 1080°F TX254 \u003cstrong\u003eRTD\u003cbr\u003e\n100 ohm Pt\u003c\/strong\u003e -50 to 750°C 30°C -50 to 300°C -58 to 1380°F 54°F\u003c\/div\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eTransmitter Scaling Recommended (TX-SCALED) unless you have a source to scale the transmitter!\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818452295975,"sku":"TX253-R--S-Type-TC-Tx","price":342.32,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818452328743,"sku":"TX253-R--S-Type-TC-Tx","price":342.32,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx250_l_pkbimqpxcuidfpey.jpg?v=1741346407"},{"product_id":"ultra-miniature-thermocouple-or-rtd-temperature-transmitters","title":"Ultra-Miniature Thermocouple or RTD Temperature Transmitters","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\u003cspan class=\"descCopyPP\"\u003e \u003cb\u003e\u003cspan style=\"color: red;\"\u003e TX93A and TX94A Series are discontinued. As an upgrade substitute, please check out the new \u003ca href=\"..\/p\/TXUN-ST-FM-Series-Tx\" target=\"_blank\"\u003eTXUN temperature transmitter\u003c\/a\u003e for details.\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e \u003ctable border=\"0\" width=\"690px\" align=\"center\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e OMEGA™ ultra-miniature temperature transmitters convert millivolt inputs from thermocouples or resistance from RTDs into 4 to 20 mA outputs. Transmitters are available in color-coded enclosures covering the four most popular thermocouple types (J, K, T, and E) as well as three-wire 100 Ω platinum RTDs. \u003cbr\u003e \u003cbr\u003e Featuring state-of-the-art integrated circuits and electronic design, these ultra-compact transmitters have a diameter of only 35.6 mm (1.40\") and are designed to fit inside many compact thermowell protection heads, such as the OMEGA™ NB2. Omega also provides complete thermocouple and RTD assemblies. \u003c\/font\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cbr\u003e TX93A and TX94A transmitters can eliminate long runs of costly field wiring in a variety of applications. A stable 4 to 20 mA output signal is produced proportional to the transmitter’s specific input type and calibrated temperature range (see Range Code table, right). Adjustability of ±25% for zero and span is provided to facilitate some rangeability. The transmitted signal eliminates noise pickup, voltage drops, and multiple cold junction errors, and it requires only a twisted pair of copper wires for loop connections. \u003cbr\u003e\u003cbr\u003e All models and ranges of these ultra-miniature transmitters are available with fully epoxy-potted electronics (specify “-P” option), which give ultimate protection in extreme environments. \u003c\/font\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818452558119,"sku":"TX93A-TX94A","price":259.7,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818452590887,"sku":"TX93A-TX94A","price":259.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx93a_tx94a_l_scteyilgedskb6ti.jpg?v=1741346429"},{"product_id":"miniature-low-cost-temperature-2-wire-transmitters","title":"Miniature Low-Cost Temperature 2-wire Transmitters","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\u003cspan class=\"descCopyPP\"\u003e \u003cb\u003e\u003cspan style=\"color: red;\"\u003e TX91A and TX92A Series are discontinued. As an upgrade substitute, please check out the new \u003ca href=\"..\/p\/TXUN-ST-FM-Series-Tx\" target=\"_blank\"\u003eTXUN temperature transmitter\u003c\/a\u003e for details.\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e \u003ctable border=\"0\" width=\"690px\" align=\"center\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e The non-isolated TX90A Series transmitters convert thermocouple or RTD signals into a 4 to 20 mA dc signal output that is directly referenced to the mV input of a thermocouple or resistance of a 100 Ohm platinum RTD.\u003cbr\u003e \u003cbr\u003e \u003ctable border=\"0\" width=\"490px\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.omega.com\/prodinfo\/thermocouples.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/intro_tc_125x125_36535d61-0a0e-4b82-a25c-5bc72dcfa1a4.jpg?v=1741330798\" border=\"0\" alt=\"Introduction to Thermocouples\"\u003e\u003c\/a\u003e\u003c\/td\u003e \u003ctd valign=\"middle\"\u003e\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e For thermocouple transmitters, the 4 to 20mA output is not linearized. T\/C transmitters are available for type K, J, T, and E with color coding for each T\/C type. The transmitters for RTD’s are available with the 4 to 20mA output directly proportional to the input resistance or with the 4 to 20mA output linearized to tempearature.\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/font\u003e\u003c\/td\u003e \u003ctd valign=\"top\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/TX91A_92A.jpg?v=1741346437\" border=\"0\" alt=\"TX91A_92A\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\u003ctable border=\"0\" width=\"690px\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\n\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003ci\u003e\u003cb\u003eNote:\u003c\/b\u003e RTD’s are slightly non-linear with the resistance diverging from actual temperature by approximately 1% at the mid point of full scale. (For linearized RTD transmitters, specify “RTD-L”. Non-linearized transmitters are the more popular choice).\u003c\/i\u003e \u003cbr\u003e\u003cbr\u003e The TX90A transmitters mount directly within OMEGA’s standard protection heads for connection to your sensor. OMEGA also provides complete thermocouple and RTD assemblies.\u003c\/font\u003e \u003cbr\u003e \u003cbr\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003e\n\u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOutput Range:\u003c\/b\u003e 4 to 20 mA dc\u003cbr\u003e \u003cb\u003eZero and Span Adjustment Range:\u003c\/b\u003e ±25% for °F and ±10% for °C\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e ±0.1% of FS (includes effects of linearity, hysteresis and repeatability) referenced to the mV input\u003cbr\u003e \u003cb\u003eOperating Temperature Range:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eStorage Temperature Range:\u003c\/b\u003e -46 to 121°C (-50 to 250°F)\u003cbr\u003e \u003cb\u003eMax Loop Resistance:\u003c\/b\u003e (Vs – 8) \/ 0.020A\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 8-50 Vdc, 24V nominal\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 44.5 D x 31.75 mm H (1.75 x 1.25\"); height includes terminal strip\u003cbr\u003e\u003cbr\u003e \u003cb\u003eRange Codes\u003c\/b\u003e\u003c\/font\u003e \u003cfont face=\"Verdana, Arial, Helvetica, sans-serif\" size=\"2\"\u003e \u003c\/font\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" width=\"660\" bordercolor=\"black\"\u003e\u003ctbody\u003e\n\u003ctr align=\"center\" bgcolor=\"Gainsboro\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cb\u003eTX91A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cb\u003eTX92A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\" bgcolor=\"Gainsboro\"\u003e\n\u003ctd\u003e\u003cb\u003eJ\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eK\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eT\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eE\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRTD\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRTD-L\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1-L\u003c\/td\u003e\n\u003ctd\u003e-40 to 60°C (-40 to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ2\u003c\/td\u003e\n\u003ctd\u003eK2\u003c\/td\u003e\n\u003ctd\u003eT2\u003c\/td\u003e\n\u003ctd\u003eE2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2-L\u003c\/td\u003e\n\u003ctd\u003e-18 to 93°C (0 to 200°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ3\u003c\/td\u003e\n\u003ctd\u003eK3\u003c\/td\u003e\n\u003ctd\u003eT3\u003c\/td\u003e\n\u003ctd\u003eE3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3-L\u003c\/td\u003e\n\u003ctd\u003e-18 to 149°C (0 to 300°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ4\u003c\/td\u003e\n\u003ctd\u003eK4\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003ctd\u003eE4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4-L\u003c\/td\u003e\n\u003ctd\u003e-18 to 260°C (0 to 500°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ5\u003c\/td\u003e\n\u003ctd\u003eK5\u003c\/td\u003e\n\u003ctd\u003eT5\u003c\/td\u003e\n\u003ctd\u003eE5\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e5-L\u003c\/td\u003e\n\u003ctd\u003e-18 to 399°C (0 to 750°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ6\u003c\/td\u003e\n\u003ctd\u003eK6\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eE6\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e6-L\u003c\/td\u003e\n\u003ctd\u003e-18 to 538°C (0 to 1000°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ7\u003c\/td\u003e\n\u003ctd\u003eK7\u003c\/td\u003e\n\u003ctd\u003eT7\u003c\/td\u003e\n\u003ctd\u003eE7\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e7-L\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C (32 to 212°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ8\u003c\/td\u003e\n\u003ctd\u003eK8\u003c\/td\u003e\n\u003ctd\u003eT8\u003c\/td\u003e\n\u003ctd\u003eE8\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e8-L\u003c\/td\u003e\n\u003ctd\u003e0 to 150°C (32 to 302°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ9\u003c\/td\u003e\n\u003ctd\u003eK9\u003c\/td\u003e\n\u003ctd\u003eT9\u003c\/td\u003e\n\u003ctd\u003eE9\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e9-L\u003c\/td\u003e\n\u003ctd\u003e0 to 250°C (32 to 482°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ10\u003c\/td\u003e\n\u003ctd\u003eK10\u003c\/td\u003e\n\u003ctd\u003eT10\u003c\/td\u003e\n\u003ctd\u003eE10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10-L\u003c\/td\u003e\n\u003ctd\u003e0 to 400°C (32 to 752°F)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr align=\"center\"\u003e\n\u003ctd\u003eJ11\u003c\/td\u003e\n\u003ctd\u003eK11\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eE11\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e0 to 500°C (32 to 932°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cb\u003eFactory Scaling (-FS) is available for an additional charge. Please contact our engineering team for custom scaling.\u003c\/b\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818453442855,"sku":"TX91A-92A-Srs-Tx","price":311.2,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818453475623,"sku":"TX91A-92A-Srs-Tx","price":311.2,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx91a_92a_l_irptiepiic1cec9t.jpg?v=1741346454"},{"product_id":"field-rangeable-mini-2-wire-transmitters-w-model-specific-input","title":"Field Rangeable Mini 2-wire Transmitters w\/ Model Specific Input","description":"\u003cp\u003eMini 2-wire transmitters convert sensor inputs such as RTDs or thermocouples into standard 4–20 mA signals. Field-rangeable settings allow easy span and zero adjustment on-site, ensuring flexible deployment. Compact and robust, these transmitters are ideal for industrial process control, reducing wiring distance and improving signal integrity.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eField-adjustable span and zero settings\u003c\/p\u003e\n\n\u003cp\u003eConverts sensor input to standard 4–20 mA output\u003c\/p\u003e\n\n\u003cp\u003eCompact, rugged design\u003c\/p\u003e\n\n\u003cp\u003eReduces wiring effects and improves accuracy\u003c\/p\u003e\n\n\u003cp\u003eIdeal for retrofits and new installations\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818453803303,"sku":"TX900-Srs-Transmitters","price":845.93,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818453836071,"sku":"TX900-Srs-Transmitters","price":845.93,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/tx900_l_kp5yecpomd9zjr0k.jpg?v=1741346479"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/collections\/TXUN-ST-FM_m.jpg?v=1741243813","url":"https:\/\/hkcalibrations.com.au\/collections\/head-mount-signal-conditioners.oembed?page=2","provider":"hkcalibrations","version":"1.0","type":"link"}