{"title":"DIN Rail Signal Conditioners","description":"DIN Rail Signal Conditioners are essential for accurate data recording in a wide range of industrial, commercial, and laboratory applications.  Used to convert input signals from a variety of sources into a uniform output, these conditioners make it possible to measure signals from thermocouples, strain gages, RTDs, load cells, and more.","products":[{"product_id":"display-programming-front-communication-interface","title":"Display\/Programming Front Communication Interface","description":"\u003cp\u003eThe Display Programming Front-Communication Interface is a modular device designed to bridge user controls, system displays, and communication networks. It provides configurable front-panel display programming and enables seamless integration into broader industrial control systems. With communication ports that support major protocols, this interface module gives technicians and system integrators flexible tools to monitor, configure, and communicate process data from the front panel. Ideal for automation panels, instrumentation kiosks, and process control cabinets where clarity, reliability, and connectivity are key.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eFront-panel display with programmable parameters and user-friendly interface.\u003c\/p\u003e\n\n\u003cp\u003eCommunication ports supporting major industrial protocols for system integration.\u003c\/p\u003e\n\n\u003cp\u003eModular design for installation in control cabinets or panels.\u003c\/p\u003e\n\n\u003cp\u003eEnables display, adjustment and monitoring of process variables in one interface.\u003c\/p\u003e\n\n\u003cp\u003eDesigned for industrial use: rugged, reliable, and built for continuous operation.\u003c\/p\u003e\n\n\u003cp\u003eSimplifies system configuration and enhances operator visibility and control.\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818400227623,"sku":"DRSL-DISPLAY-Programmer","price":166.02,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818400260391,"sku":"DRSL-DISPLAY-Programmer","price":166.02,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-display_angle_450_hz75k0jkqs9siptm.jpg?v=1741345136"},{"product_id":"isolated-universal-signal-transmitter","title":"Isolated Universal Signal Transmitter","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cp\u003eOMEGA’s new isolated signal converter delivers high performance for integration in a wide range of industrial applications. The DR-I3P accepts universal inputs including mA and Vdc process signals (provides +15Vdc excitation voltage), usual temperature signals such as Pt100, Pt500, Pt1000, Ni100, Ni1000, NTC, thermocouples J, K, N, E, T, R and S, resistances and potentiometer signals, offering application flexibility for signal acquisition and industrial requirements.\u003c\/p\u003e \u003cp\u003eA single universal AC\/DC power supply allows this unit to be suited for global use.\u003c\/p\u003e \u003cp\u003eConfigurable output in 4\/20mA or 0\/10Vdc, high levels of isolation and DIN rail mount.\u003c\/p\u003e \u003cp\u003eAdditional features of the DR-I3P isolated signal converter include ready to use ‘out of the box’ unit, with no additional configuration tools needed, easy configuration by programming codes, and special ‘force’ functions for installation testing.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818400981287,"sku":"DR-I3P-Signal-Converter","price":432.24,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818401014055,"sku":"DR-I3P-Signal-Converter","price":432.24,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dr-i3p-single_450_udp6yh8mfug8yuxl.jpg?v=1741345158"},{"product_id":"din-rail-input-loop-powered-isolators-w-1-or-2-channel-models","title":"DIN Rail Input Loop Powered Isolators w\/ 1 or 2 Channel Models","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-LPI Series DIN rail input loop powered isolators provide a competitive choice in terms of both price and technology for galvanic isolation of current signals to SCADA systems or PLC equipment. These units provide isolation and 1:1 conversion of standard current signals and are powered by the analog input current signal loop.\u003cbr\u003e\u003cbr\u003e The DRSL-LPI series offers isolation between input and output, provides surge suppression and protects control systems from transients and noise. These units also eliminate ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. These isolators operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNUMBER OF CHANNELS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDRSL-LPI-1:\u003c\/b\u003e 1\u003cbr\u003e \u003cb\u003eDRSL-LPI-2:\u003c\/b\u003e 2\u003cbr\u003e \u003cb\u003eCURRENT INPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range (Input to Output):\u003c\/b\u003e 0 to 20.5 mA\u003cbr\u003e \u003cb\u003eSignal Conversion:\u003c\/b\u003e 1 to 1\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 23 mA (NAMUR NE43 compliant)\u003cbr\u003e \u003cb\u003eStart up Current:\u003c\/b\u003e 10 µA typical\u003cbr\u003e \u003cb\u003eInput Overload:\u003c\/b\u003e 50 mA max\u003cbr\u003e \u003cb\u003eInput to Output Voltage Drop:\u003c\/b\u003e 1.25V + (0.015 x Vout) where Vout = Iout x Routput, typical\u003cbr\u003e \u003cb\u003eInput Voltage Drop:\u003c\/b\u003e (Unit voltage drop) + Vout\u003cbr\u003e \u003cb\u003eCURRENT OUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOutput Load:\u003c\/b\u003e 600Ω max\u003cbr\u003e \u003cb\u003eOutput Load Stability:\u003c\/b\u003e \u0026lt;0.01% of span\/100 Ω (span = 0 to 20 mA)\u003cbr\u003e \u003cb\u003eVoltage Limit:\u003c\/b\u003e 17.5V\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 30 mW per channel\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eCut-Off Frequency (3 dB):\u003c\/b\u003e 100 Hz\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;5 ms\u003cbr\u003e \u003cb\u003eAbsolute Accuracy (at 25°C):\u003c\/b\u003e ≤±10 µA + 0.05% of max value of selected span\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e ≤±2 µA\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity NAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818401636647,"sku":"DRSL-LPI-Srs-Loop-Pwr-Iso","price":480.57,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818401669415,"sku":"DRSL-LPI-Srs-Loop-Pwr-Iso","price":480.57,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-lpi_series_l_akxcf1i9jnf9wwgg.jpg?v=1741345183"},{"product_id":"din-rail-conditioners-convert-bridge-inputs-to-ma-or-voltage","title":"DIN Rail Conditioners Convert Bridge Inputs to mA or Voltage","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe DMD4059 accepts an input from full Wheatstone strain bridge sensors, pressure transducers or load cells. It provides filtering, amplifies, and converts the millivolt input signal into the selected dc voltage or current output that is linear to the input. The 3-way 1200V isolation eliminates ground loops, common mode voltages and greatly reduces noise pick-up. Sense wire connections are available to give maximum accuracy. Input, output, excitation and zero offset are field configurable via external rotary and slide switches. Offsets of up to ±100% of span can be used to cancel sensor offsets or tare fixed loads. Features such as red and green LEDs vary in intensity to show input and output activity and an output test button helps with set-up and troubleshooting.\u003cbr\u003e\n \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eInput Range (unipolar):   Minimum:\u003c\/strong\u003e 0 to 5 mV range, 0.5 mV\/V sensitivity\u003cbr\u003e\n\u003cstrong\u003e   Maximum:\u003c\/strong\u003e 0 to 400 mV range, 40 mV\/V sensitivity\u003cbr\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 200 kΩ typical\u003cbr\u003e\n\u003cstrong\u003eExcitation Voltage: \u003c\/strong\u003eSwitch selectable 0 to 10 Vdc in 1V increments\u003cbr\u003e\n\u003cstrong\u003e    Maximum Output: \u003c\/strong\u003e10 Vdc @ 120 mA\u003cbr\u003e\n\u003cstrong\u003e    Fine Adjustment: \u003c\/strong\u003e±5% via multi-turn potentiometer\u003cbr\u003e\n\u003cstrong\u003e    Stability: \u003c\/strong\u003e±0.01% per °C\u003cbr\u003e\n\u003cstrong\u003eSense Lead Compensation:\u003c\/strong\u003e Better than ±0.01% per 1Ω change in leadwire resistance\u003cbr\u003e\n\u003cstrong\u003e   Maximum Lead Wire Resistance: \u003c\/strong\u003e10Ω with 350Ω @ 10 Vdc\u003cbr\u003e\n\u003cstrong\u003e   Zero Offset (Tare):\u003c\/strong\u003e ±100% of span in 15% increments\u003cbr\u003e\n\u003cstrong\u003eOutput Ranges:\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003e   Voltage (10 mA max):\u003c\/strong\u003e 0-1 to 0-10 Vdc\u003cbr\u003e\n\u003cstrong\u003e   Bipolar Voltage (10 mA max): \u003c\/strong\u003e±5 or ±10 Vdc\u003cbr\u003e\n\u003cstrong\u003e   Current:\u003c\/strong\u003e 0-2 mA to 0-25 mA\u003cbr\u003e\n\u003cstrong\u003e   Compliance, Drive @ 20 mA\u003c\/strong\u003e: 20V, 1000\u0026amp;937; drive; current output can be selectively wired for sink or source.\u003cbr\u003e\n\u003cstrong\u003eOutput Linearity, Ripple and Noise:\u003c\/strong\u003e Better than ±0.1% of span, \u0026lt;10 mV rms ripple and noise\u003cbr\u003e\n\u003cstrong\u003eOutput Zero and Span (Fine Adjustment):\u003c\/strong\u003e Multi-turn potentiometers to compensate for load and lead variations, ±15% of span adjustment range typical\u003cbr\u003e\n\u003cstrong\u003eFunction Test Button:\u003c\/strong\u003e Sets output to test level when pressed. Adjustable 0 to 100% of span via potentiometer. Factory default is approx 50% of span.\u003cbr\u003e\n\u003cstrong\u003eResponse Time: \u003c\/strong\u003e 70 ms typical\u003cbr\u003e\n\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e 100 db min\u003cbr\u003e\n\u003cstrong\u003eIsolation: \u003c\/strong\u003e1200 Vrms min, 3-way isolation, power to input, power to output and input to output\u003cbr\u003e\n\u003cstrong\u003eOperating Temp Range:\u003c\/strong\u003e -10 to 60 °C (14 to 140 °F)\u003cbr\u003e\n\u003cstrong\u003eThermal Stability:\u003c\/strong\u003e Better than ±0.02% of span per °C\u003cbr\u003e\n\u003cstrong\u003eStandard Power:\u003c\/strong\u003e 80 to 265 Vac, 50\/60 Hz or 85 to 300 Vdc\u003cbr\u003e\n\u003cstrong\u003eLow Voltage \"DC\" Option:\u003c\/strong\u003e 9 to 30 Vdc or 10 to 32 Vac\u003cbr\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 2 to 5 W depending upon number of load cells\u003cbr\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mounts to standard 35 mm DIN rail\u003cbr\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e IP40\u003cbr\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Four 4-terminal removable connectors 14 AWG max wire size\u003cbr\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 22.5 W x 117 H x 122 mm D (0.89 x 4.62 x 4.81\"), height includes connectors\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818401898791,"sku":"DMD4059-Series-Sig-Cond","price":1219.59,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818401931559,"sku":"DMD4059-Series-Sig-Cond","price":1219.59,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dmd4059_l_kimkjorx985nlttr.jpg?v=1741345207"},{"product_id":"din-rail-thermocouple-input-signal-conditioners-low-profile","title":"DIN Rail Thermocouple Input Signal Conditioners | Low Profile","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-TC Series thermocouple input DIN rail signal conditioners provide a competitive choice in terms of both price and technology for interfacing thermocouple inputs to SCADA systems or PLC equipment.\u003cbr\u003e\u003cbr\u003e The DRSL-TC and DRSL-TC-ISO can be used for signal conversion of standard Type J or K thermocouple inputs into unipolar analog signals.\u003cbr\u003e\u003cbr\u003e The DRSL-TC-ISO isolated model offers 3-way isolation between input, output and supply and provides surge suppression and protects control systems from transients and noise. Low power consumption facilitates DIN rail mounting without the need for any air gap. Easy configuration of more than 1000 factory calibrated measurement ranges is done via DIP-switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e J or K thermocouple\u003cbr\u003e \u003cb\u003eTemperature Range\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType J:\u003c\/b\u003e -100 to 1200°C (-148 to 2192°F)\u003cbr\u003e \u003cb\u003eType K:\u003c\/b\u003e -180 to 1372°C (-292 to 2501°F)\u003cbr\u003e \u003cb\u003eSensor and Cable Specifications:\u003c\/b\u003e 5 kΩ per wire\u003cbr\u003e \u003cb\u003eCold Junction Compensation (CJC):\u003c\/b\u003e Internal or external (selectable)\u003cbr\u003e \u003cb\u003eCJC Accuracy via External CJC (Pt100 RTD Sensor):\u003c\/b\u003e Better than ±0.15°C (DRSL-TC-ISO only)\u003cbr\u003e \u003cb\u003eCJC via Internally Mounted Sensor:\u003c\/b\u003e Better than ±2.5°C\u003cbr\u003e \u003cb\u003eOpen Thermocouple Detection:\u003c\/b\u003e Yes (DIP switch selectable upscale or downscale)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 and 4 to 20 mA\u003cbr\u003e \u003cb\u003eRange Limits (NAMUR NE43 Out of Range):\u003c\/b\u003e Below 3.8 mA or above 20.5 mA for 4 to 20 mA output; 0 mA or above 20.5 mA for 0 to 20 mA output\u003cbr\u003e \u003cb\u003eSensor Error Detection (Dip Switch Selectable for Enable or None):\u003c\/b\u003e Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output\u003cbr\u003e \u003cb\u003eIncorrect DIP-Switch Setting Identification:\u003c\/b\u003e 0 mA\u003cbr\u003e \u003cb\u003eOutput Error Level:\u003c\/b\u003e DIP switch selectable for upscale or downscale\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 21 mA\/600 Ω \/12.6V max\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/100 Ω\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 10V, 2 to 10V, 0 to 5V and 1 to 5V\u003cbr\u003e \u003cb\u003eRange Limits (Out of Range):\u003c\/b\u003e Range ±2.5%\u003cbr\u003e \u003cb\u003eIncorrect DIP Switch Setting Identification:\u003c\/b\u003e 0V\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e \u0026gt;10 kΩ min\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDRSL-TC:\u003c\/b\u003e 16.8 to 31.2 Vdc via connectors\u003cbr\u003e \u003cb\u003eDRSL-TC-ISO:\u003c\/b\u003e 16.8 to 31.2 Vdc via power rail or connectors\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 0.7 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.65 W max\u003cbr\u003e \u003cb\u003eIsolation (DRSL-TC-ISO Only):\u003c\/b\u003e Input\/output\/supply\u003cbr\u003e \u003cb\u003eIsolation Voltage, Test (DRSL-TC-ISO Only):\u003c\/b\u003e 2.5 kVac (reinforced)\u003cbr\u003e \u003cb\u003eIsolation Voltage, Working (DRSL-TC-ISO Only):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eStatus LED:\u003c\/b\u003e Green LED indicates operational status of the unit and input sensor\u003cbr\u003e \u003cb\u003eNormal Operation:\u003c\/b\u003e Flashes for 15 ms at 13 Hz rate\u003cbr\u003e \u003cb\u003eSensor Error:\u003c\/b\u003e Flashes for 15 ms at 1 Hz rate\u003cbr\u003e \u003cb\u003eIncorrect DIP Switch Setting:\u003c\/b\u003e Flashes for 500 ms at 1 Hz rate\u003cbr\u003e \u003cb\u003eHardware Failure:\u003c\/b\u003e LED off\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;30 ms\/300 ms (selectable, provides either fast response or signal dampening as needed)\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDRSL-TC:\u003c\/b\u003e Better than 1.0°C or ±0.1% of selected input range\u003cbr\u003e \u003cb\u003eDRSL-TC-ISO:\u003c\/b\u003e Better than 0.5°C or ±0.05% of selected input range\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e ≤±0.1°C\/°C or ≤±0.01%\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity NAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span (span = selected input range)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/ AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818402455847,"sku":"DRSL-TC-Srs-Sig-Cond","price":443.51,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818402488615,"sku":"DRSL-TC-Srs-Sig-Cond","price":443.51,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-tc_series_l_vxbg8liwkn2p1wik.jpg?v=1741345228"},{"product_id":"din-rail-rtd-input-signal-conditioner-low-profile","title":"DIN Rail RTD Input Signal Conditioner | Low Profile","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-RTD Series RTD input DIN rail signal conditioners provide a competitive choice in terms of both price and technology for interfacing RTD inputs to SCADA systems or PLC equipment. The DRSL-RTD and DRSL-RTD-ISO can be used for signal conversion of 2, 3 or 4-wire Pt100 RTD inputs into unipolar analog signals. The DRSL-RTD-ISO isolated model offers 3-way isolation between input, output and supply and provides surge suppression and protects control systems from transients and noise. Low power consumption facilitates DIN rail mounting without the need for any air gap. Easy configuration of more than 1000 factory calibrated measurement ranges is done via DIP-switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Type:\u003c\/b\u003e 2, 3, or 4-wire Pt100 RTD\u003cbr\u003e \u003cb\u003eTemperature Range:\u003c\/b\u003e -200 to 850°C (-328 to 1562°F)\u003cbr\u003e \u003cb\u003eSensor Current, RTD:\u003c\/b\u003e \u0026lt;150 µA\u003cbr\u003e \u003cb\u003eSensor Cable Specifications:\u003c\/b\u003e 50 Ω per wire or 50 nF\u003cbr\u003e \u003cb\u003eEffect of Sensor Cable Resistance (3 or 4-wire RTD):\u003c\/b\u003e \u0026lt;0.002 Ω\/Ω\u003cbr\u003e \u003cb\u003eBroken Sensor Detection:\u003c\/b\u003e \u0026gt;800 Ω\u003cbr\u003e \u003cb\u003eShorted Sensor Detection:\u003c\/b\u003e \u0026lt;18 Ω\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eRange Limits (NAMUR NE43 Out of Range):\u003c\/b\u003e Below 3.8 mA or above 20.5 mA for 4 to 20 mA output; 0 mA or above 20.5 mA for 0 to 20 mA output\u003cbr\u003e \u003cb\u003eSensor Error Detection (Dip Switch Selectable for Enable or None):\u003c\/b\u003e Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output\u003cbr\u003e \u003cb\u003eIncorrect DIP-Switch Setting Identification:\u003c\/b\u003e Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output\u003cbr\u003e \u003cb\u003eOutput Error Level:\u003c\/b\u003e DIP switch selectable for upscale or downscale\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 21 mA\/600Ω \/12.6V max\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/100Ω\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 10 V, 2 to 10 V, 0 to 5 V and 1 to 5 V\u003cbr\u003e \u003cb\u003eRange Limits (Out of Range):\u003c\/b\u003e Range ±2.5%\u003cbr\u003e \u003cb\u003eSensor Error Detection (Dip Switch Selectable for Enable or None):\u003c\/b\u003e 0V or selected range + 10%\u003cbr\u003e \u003cb\u003eIncorrect DIP-Switch Setting Identification:\u003c\/b\u003e 0V\u003cbr\u003e \u003cb\u003eOutput Error Level:\u003c\/b\u003e DIP switch selectable for upscale or downscale\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e \u0026gt;10 kΩ min\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDRSL-RTD:\u003c\/b\u003e 16.8 to 31.2 Vdc via connectors\u003cbr\u003e \u003cb\u003eDRSL-RTD-ISO:\u003c\/b\u003e 16.8 to 31.2 Vdc via power rail or connectors\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 0.7 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.65 W max\u003cbr\u003e \u003cb\u003eIsolation (DRSL-RTD-ISO Only):\u003c\/b\u003e Input\/output\/supply\u003cbr\u003e \u003cb\u003eIsolation Voltage, Test (DRSL-RTD-ISO Only):\u003c\/b\u003e 2.5 kVac (reinforced)\u003cbr\u003e \u003cb\u003eIsolation Voltage, Working (DRSL-RTD-ISO Only):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eStatus LED:\u003c\/b\u003e Green LED indicates operational status of the unit and input sensor\u003cbr\u003e \u003cb\u003eNormal Operation:\u003c\/b\u003e Flashes for 15 ms at 13 Hz rate\u003cbr\u003e \u003cb\u003eSensor Error:\u003c\/b\u003e Flashes for 15 ms at 1 Hz rate\u003cbr\u003e \u003cb\u003eIncorrect DIP Switch Setting:\u003c\/b\u003e flashes for 500 ms at 1 Hz rate\u003cbr\u003e \u003cb\u003eHardware Failure:\u003c\/b\u003e LED off\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;30 ms\/300 ms (selectable, provides either fast response or signal dampening as needed) \u003cbr\u003e \u003cb\u003eAccuracy\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDRSL-RTD:\u003c\/b\u003e Better than 0.2°C or ±0.1% of selected input range\u003cbr\u003e \u003cb\u003eDRSL-RTD-ISO:\u003c\/b\u003e Better than 0.1°C or ±0.05% of selected input range\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e ≤±0.02°C\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity NAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span (span = selected input range)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/ AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818402914599,"sku":"DRSL-RTD-Srs-Sig-Cond","price":437.31,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818402947367,"sku":"DRSL-RTD-Srs-Sig-Cond","price":437.31,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-rtd_series_l_wioeur92dkfafju2.jpg?v=1741345250"},{"product_id":"din-rail-universal-uni-bipolar-dc-signal-conditioner","title":"DIN Rail Universal Uni\/Bipolar DC Signal Conditioner","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e \u003cb\u003eApplication\u003c\/b\u003e\u003cbr\u003e     • Fast \u0026lt; 20 ms response time for measuring signals produced by torque, position, current \u0026amp; acceleration sensors.\u003cbr\u003e     • User configurable bipolar or unipolar I\/O means the DRST-DC is suitable for nearly any DC voltage or current       conversion.\u003cbr\u003e     • Freely programmable between ±300 VDC and ±100 mA. The excitation source allows measurement of a 2-wire or 3-wire transmitter, or a potentiometer.\u003cbr\u003e     • Converts narrow bipolar inputs to wide bipolar or unipolar outputs, e.g., ± 1 volt input = ± 10 volt or 4 to 20 mA       output.\u003cbr\u003e     • Configurable input limits control the output value for increased safety.\u003cbr\u003e     • ±20 VDC buffered voltage output for controlling devices like the PVG 32 valve (6 to 18 VDC).\u003cbr\u003e\u003cbr\u003e \u003cb\u003eTechnical Characteristics\u003c\/b\u003e\u003cbr\u003e     • The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.\u003cbr\u003e     • Possibility of output safety read back by selecting 4 to 20 mA output.\u003cbr\u003e     • The current output can drive up to 1000 Ω, with an adjustable response time of 0.0…60.0 seconds.\u003cbr\u003e     • Exceptional mA output load stability of \u0026lt; 0.001% of span\/100 Ω.\u003cbr\u003e     • Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.\u003cbr\u003e     • Meets the NAMUR NE43 recommendations, allowing the control system to easily detect a sensor error.\u003cbr\u003e     • Each unit is tested to a high 2.3 kVAC, 3-port galvanic isolation level.\u003cbr\u003e     • Excellent signal to noise ratio of \u0026gt; 60 dB.\u003cbr\u003e \u003cb\u003eMounting\/Installation\/Programming\u003c\/b\u003e\u003cbr\u003e     • Very low power consumption means units can be mounted side by side without an air gap – even at 60°C   (140ºF) ambient temperature.\u003cbr\u003e     • Configuration, monitoring, 2-point process calibration and more are accomplished using either the DRSL-Display       detachable display or the DRST-CM detachable digital communication enabler.\u003cbr\u003e     • All programming can be password-protected.\u003cbr\u003e\u003cbr\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/DRST-DC_20Dia.jpg?v=1741345262\" width=\"443\" height=\"750\"\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEnvironmental Conditions\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -20 to 60°C\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -20 to 85°C\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e \u0026lt; 95% RH (non-cond.)\u003cbr\u003e \u003cb\u003eProtection degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eMechanical Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions (H x W x D):\u003c\/b\u003e 109 x 23.5 x 104 mm\u003cbr\u003e \u003cb\u003eDimensions (H x W x D) with 4501\/4511:\u003c\/b\u003e 109 x 23.5 x 116\/131 mm\u003cbr\u003e \u003cb\u003eWeight Approx:\u003c\/b\u003e 250 g\u003cbr\u003e \u003cb\u003eWeight Incl. 4501\/4511 (approx.):\u003c\/b\u003e 285 g\/350 g \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715\/35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 to 2.08 mm\u003csup\u003e2\u003c\/sup\u003e AWG 26 to 14 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm\u003cbr\u003e \u003cb\u003eCommon Specifications\u003cbr\u003e Supply\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage, Universal:\u003c\/b\u003e 21.6 to 253 VAC, 50 to 60 Hz or 19.2 to 300 VDC\u003cbr\u003e \u003cb\u003eMax. Required Power:\u003c\/b\u003e = 2.5 W\u003cbr\u003e \u003cb\u003eInternal Power Dissipation:\u003c\/b\u003e = 2.0 W\u003cbr\u003e \u003cb\u003eIsolation Voltage\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTest Voltage:\u003c\/b\u003e 2.3 kVAC\u003cbr\u003e \u003cb\u003eWorking Voltage:\u003c\/b\u003e 250 VAC (reinforced)\/500n VAC (basic)\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e (0 to 90%, 100 to 10%) \u0026lt; 20 ms\u003cbr\u003e \u003cb\u003eAuxiliary Supplies\u003c\/b\u003e\u003cbr\u003e \u003cb\u003e2-wire Loop Supply:\u003c\/b\u003e \u0026gt; 16 V @ 20 mA\u003cbr\u003e \u003cb\u003e3-wire Loop Supply:\u003c\/b\u003e \u0026gt; 18 to \u0026lt; 28 V @ 23 to 0 mA\u003cbr\u003e \u003cb\u003eLoop Supply Limitation:\u003c\/b\u003e 27 to 35 mA avg., \u0026lt; 80 mA peak\u003cbr\u003e \u003cb\u003eReference Voltage:\u003c\/b\u003e 2.5 VDC ±0.5%\u003cbr\u003e \u003cb\u003eReference Voltage, Load:\u003c\/b\u003e 0 to 15 mA\u003cbr\u003e \u003cb\u003eCurrent Limit, Reference Voltage:\u003c\/b\u003e \u0026lt; 60 mA\u003cbr\u003e \u003cb\u003eProgramming:\u003c\/b\u003e Communication enabler 4511\/Programming front 4501\u003cbr\u003e \u003cb\u003eSignal Dynamics, Input:\u003c\/b\u003e 24 bit\u003cbr\u003e \u003cb\u003eSignal Dynamics, Output:\u003c\/b\u003e 18 bit\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt; 60 dB\u003cbr\u003e \u003cb\u003eBandwidth:\u003c\/b\u003e \u0026gt; 40 Hz\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e Better than 0.05% of selected range\u003cbr\u003e \u003cb\u003eEMC Immunity Iinfluence:\u003c\/b\u003e \u0026lt; ±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity:\u003c\/b\u003e NAMUR\u003cbr\u003e \u003cb\u003eNE21, A Criterion, Burst:\u003c\/b\u003e \u0026lt; ±1% of span \u003cb\u003eConducted Emission, class A:\u003c\/b\u003e 150 kHz to 10 MHz\u003cbr\u003e \u003cb\u003eInput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Input\u003cbr\u003e Signal Range\u003c\/b\u003e: ±100 mA\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 1, 0 to 5, 1 to 5, 0 to 20, 4 to 20, ±1, ±5, ±10, ±20, ±50, ±100 mA\u003cbr\u003e Custom Configurable Signal Range: ±100 mA\u003cbr\u003e \u003cb\u003eMin. Measurement Range (span):\u003c\/b\u003e 0.5 mA\u003cbr\u003e \u003cb\u003eInput Voltage Drop:\u003c\/b\u003e 0.6 V @ 20 mA nom.\u003cbr\u003e \u003cb\u003eVoltage Input\u003cbr\u003e Signal range:\u003c\/b\u003e ±300 VDC\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 0.1, 0 to 1, 0.2 to 1, 0 to 2.5, 0 to 5, 1 to 5, 0 to 10, 2 to 10, 0 to 100,\u003cbr\u003e 0 to 300, ±0.1, ±1, ±2.5, ±5, ±10, ±100, ±300 V\u003cbr\u003e \u003cb\u003eCustom Configurable Signal Range:\u003c\/b\u003e±300 V\u003cbr\u003e \u003cb\u003eMin. Measurement Range (span):\u003c\/b\u003e 25 mV\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e Nom. 3 MΩ (\u0026gt; 2.5 VDC)\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003eNom. \u0026gt; 10 MΩ (= 2.5 VDC)\u003cbr\u003e \u003cb\u003ePotentiometer Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003e3-wire Potentiometer Input:\u003c\/b\u003e 0 to 100%\u003cbr\u003e \u003cb\u003eReference Voltage:\u003c\/b\u003e 2.5 V\u003cbr\u003e \u003cb\u003eCalibration Resistance:\u003c\/b\u003e 5 kΩ\u003cbr\u003e \u003cb\u003eMin. Potentiometer Resistance:\u003c\/b\u003e 200 Ω\u003cbr\u003e \u003cb\u003eOutput Specifications\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 23 mA (unipolar)\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e -23 to 23 mA (bipolar)\u003cbr\u003e \u003cb\u003eCustom Config. Output Range:\u003c\/b\u003e ±20 mA\u003cbr\u003e \u003cb\u003eMin. Signal Range:\u003c\/b\u003e 4 mA\u003cbr\u003e \u003cb\u003eLoad (@ Current Output):\u003c\/b\u003e = 1000 Ω\/± 20 V @ ±20 mA\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e = 28 mA (unipolar)\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ± 28 mA (bipolar)\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e = 0.001% of span \/ 100 Ω\u003cbr\u003e \u003cb\u003eResponse Time, Programmable:\u003c\/b\u003e 0.0 to 60.0 s\u003cbr\u003e \u003cb\u003ePassive 2-wire mA Output\u003cbr\u003e Programmable Ranges:\u003c\/b\u003e 0 to 20 and 4 to 20 mA\u003cbr\u003e \u003cb\u003eExt. 2-Wire Loop Supply Range:\u003c\/b\u003e 3.5 to 28.8 VDC\u003cbr\u003e\u003cbr\u003e \u003cb\u003eVoltage Output\u003cbr\u003e Programmable Signal Ranges:\u003c\/b\u003e 0\/0.2 to 1; 0\/1 to 5 ; 0\/2 to 10 V\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e ±1, ±5 and ±10 V\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003eDirect or Inverted action\u003cbr\u003e \u003cb\u003eLoad (@ Voltage Output):\u003c\/b\u003e = 500 kΩ\u003cbr\u003e \u003cb\u003eResponse Time, Programmable:\u003c\/b\u003e 0.0 to 60.0 s\u003cbr\u003e \u003cb\u003eShunted Voltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e ± 1.2 V\/± 12 V\u003cbr\u003e \u003cb\u003eProgrammable Standard Ranges:\u003c\/b\u003e 0 to 1, 0 to 2.5, 0 to 5, 1 to 5, 0 to 10, 2 to 10 V ±1, ±2.5, ±5, ±10 V\u003cbr\u003e \u003cb\u003eMin. Span:\u003c\/b\u003e 0.8 V\u003cbr\u003e \u003cb\u003eCustom Config. Output Range:\u003c\/b\u003e ±10 V\u003cbr\u003e \u003cb\u003eLoad, Min:\u003c\/b\u003e \u0026gt; 500 kΩ \u003cb\u003eBuffered Voltage Output\u003cbr\u003e Signal range:\u003c\/b\u003e ± 23 V\u003cbr\u003e \u003cb\u003eProgrammable Standard Ranges:\u003c\/b\u003e 0 to 1, 0.2 to 1, 0 to 2.5, 0 to 5,1 to 5, 0 to 10, 2 to 10, 0 to 20, 4 to 20; ±1, ±2.5, ±5, ±10, ±20 V\u003cbr\u003e \u003cb\u003eMin. Span:\u003c\/b\u003e 0.8 V\u003cbr\u003e \u003cb\u003eCustom Config. Output Range:\u003c\/b\u003e ±20 V\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e \u0026lt; 50 mA\u003cbr\u003e \u003cb\u003eLoad, Min:\u003c\/b\u003e \u0026gt; 2 kΩ\u003cbr\u003e \u003cb\u003eObserved Authority Requirements\u003cbr\u003e LVD:\u003c\/b\u003e 2014\/35\/EU\u003cbr\u003e \u003cb\u003eEMC:\u003c\/b\u003e 2014\/30\/EU\u003cbr\u003e \u003cb\u003eRoHS:\u003c\/b\u003e 2011\/65\/EU\u003cbr\u003e \u003cb\u003eApprovals\u003cbr\u003e UL:\u003c\/b\u003e UL 508\/CC22.2 no. 14 \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818403209511,"sku":"DRST-DC-Univ-BP-Sig-Cond","price":614.8,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818403242279,"sku":"DRST-DC-Univ-BP-Sig-Cond","price":614.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drst-dc_l_e0ewppzr7nclrnzx.jpg?v=1741345279"},{"product_id":"din-rail-temperature-loop-powered-signal-conditioner","title":"DIN Rail Temperature Loop Powered Signal Conditioner","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-TEMP isolated DIN rail loop-powered temperature signal conditioner measures a standard type J or K thermocouple or a 2-, 3- or 4-wire Pt100 RTD temperature sensor and provides a passive analog current output signal.\u003cbr\u003e\u003cbr\u003eThe DRSL-TEMP offers 2-way isolation between input and output, provides surge suppression and protects control systems from transients and noise.\u003cbr\u003e\u003cbr\u003e The DRSL-TEMP provides a competitive choice in terms of both price and technology for interfacing thermocouple or RTD signals to SCADA systems or PLC equipment. This unit is powered by the host (output) current signal loop. Low power consumption facilitates DIN rail mounting without the need for any air gap. Easy configuration of more than 1000 factory calibrated measurement ranges is done via DIP-switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTHERMOCOUPLE INPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e J or K thermocouple\u003cbr\u003e \u003cb\u003eTemperature Range (DIP Swich Selectable)\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType J:\u003c\/b\u003e -100 to 1200°C (-148 to 2192°F)\u003cbr\u003e \u003cb\u003eType K:\u003c\/b\u003e -180 to 1372°C (-292 to 2501°F)\u003cbr\u003e \u003cb\u003eSensor and Cable Specifications:\u003c\/b\u003e 5 kΩ per wire\u003cbr\u003e \u003cb\u003eCold Junction Compensation (CJC):\u003c\/b\u003e Internal or external (selectable)\u003cbr\u003e \u003cb\u003eCJC Accuracy via External CJC (Pt100 RTD Sensor):\u003c\/b\u003e Better than ±0.15°C\u003cbr\u003e \u003cb\u003eCJC via Internally Mounted Sensor:\u003c\/b\u003e Better than ±2.5°C\u003cbr\u003e \u003cb\u003eOpen Thermocouple Detection:\u003c\/b\u003e Yes (DIP switch selectable upscale or downscale)\u003cbr\u003e \u003cb\u003ePt100 RTD INPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e 2, 3, or 4-wire Pt100 RTD\u003cbr\u003e \u003cb\u003eTemperature Range (DIP Switch Selectable):\u003c\/b\u003e -200 to 850°C (-328 to 1562°F)\u003cbr\u003e \u003cb\u003eSensor Current, RTD:\u003c\/b\u003e \u0026lt;150 µA\u003cbr\u003e \u003cb\u003eSensor Cable Specifications:\u003c\/b\u003e 50 Ω per wire\u003cbr\u003e \u003cb\u003eEffect of Sensor Cable Resistance (3 or 4-Wire RTD):\u003c\/b\u003e \u0026lt;0.002 Ω\/Ω\u003cbr\u003e \u003cb\u003eBroken Sensor Detection:\u003c\/b\u003e \u0026gt;800 Ω\u003cbr\u003e \u003cb\u003eShorted Sensor Detection:\u003c\/b\u003e \u0026lt;18 Ω\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eRange Limits (NAMUR NE43 Out of Range):\u003c\/b\u003e Below 3.8 mA or above 20.5 mA\u003cbr\u003e \u003cb\u003eSensor Error Detection (Dip Switch Selectable for Enable or None):\u003c\/b\u003e Below 3.5 mA or above 23 mA\u003cbr\u003e \u003cb\u003eIncorrect DIP-Switch Setting Identification:\u003c\/b\u003e Below 3.5 mA\u003cbr\u003e \u003cb\u003eOutput Error Level:\u003c\/b\u003e DIP switch selectable for upscale or downscale\u003cbr\u003e \u003cb\u003eLoad Resistance (Ω):\u003c\/b\u003e ≤(Vsupply - 5.5)\/0.023\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/100 Ω\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 5.5 to 35 Vdc\u003cbr\u003e \u003cb\u003eVoltage Drop:\u003c\/b\u003e 5.5 Vdc\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input\/output\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac (reinforced)\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;30 ms\/300 ms (selectable, provides either fast response or signal dampening as needed)\u003cbr\u003e \u003cb\u003eAccuracy\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eThermocouple Input:\u003c\/b\u003e Better than 0.5°C or ±0.05% of span (selected input range)\u003cbr\u003e \u003cb\u003eRTD Input:\u003c\/b\u003e Better than 0.1°C or ±0.05% of span (selected input range)\u003cbr\u003e \u003cb\u003eTemperature Coefficient\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eThermocouple Input:\u003c\/b\u003e ≤±0.1°C\/°C or ≤±0.01%\/°C\u003cbr\u003e \u003cb\u003eRTD Input:\u003c\/b\u003e ≤±0.02 °C\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u003cb\u003eExtended EMC Immunity\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span (span = selected input range)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818403832103,"sku":"DRSL-TEMP-Sig-Cond","price":387.05,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818403864871,"sku":"DRSL-TEMP-Sig-Cond","price":387.05,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-temp_l_5kgbac3degskcgvp.jpg?v=1741345302"},{"product_id":"non-isolated-loop-powered-din-rail-rtd-input-conditioner","title":"Non Isolated Loop Powered DIN Rail RTD Input Conditioner","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-RTD-LP RTD input non-isolated DIN rail loop-powered signal conditioner measures a standard 2-, 3- or 4-wire Pt100 temperature sensor and provides a passive analog current output signal. The DRSL-RTD-LP provides a competitive choice in terms of both price and technology for interfacing RTD signals to SCADA systems or PLC equipment. This unit is powered by the host (output) current signal loop. Low power consumption facilitates DIN rail mounting without the need for any air gap. Easy configuration of more than 1000 factory calibrated measurement ranges is done via DIP-switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Type:\u003c\/b\u003e 2, 3, or 4-wire Pt100 RTD\u003cbr\u003e \u003cb\u003eTemperature Range:\u003c\/b\u003e -200 to 850°C (-328 to 1562°F)\u003cbr\u003e \u003cb\u003eSensor Current, RTD:\u003c\/b\u003e \u0026lt;150 µA\u003cbr\u003e \u003cb\u003eSensor Cable Specifications:\u003c\/b\u003e 50Ω per wire or 50 nF\u003cbr\u003e \u003cb\u003eEffect of Sensor Cable Resistance (3 or 4-Wire RTD):\u003c\/b\u003e \u0026lt;0.002Ω\/Ω\u003cbr\u003e \u003cb\u003eBroken Sensor Detection:\u003c\/b\u003e \u0026gt;800Ω\u003cbr\u003e \u003cb\u003eShorted Sensor Detection:\u003c\/b\u003e \u0026lt;18Ω\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eRange Limits (NAMUR NE43 Out of Range):\u003c\/b\u003e Below 3.8 mA or above 20.5 mA\u003cbr\u003e \u003cb\u003eSensor Error Detection (Dip Switch Selectable for Enable or None):\u003c\/b\u003e Below 3.5 mA or above 23 mA\u003cbr\u003e \u003cb\u003eIncorrect DIP-Switch Setting Identification:\u003c\/b\u003e Below 3.5 mA or above 23 mA\u003cbr\u003e \u003cb\u003eOutput Error Level:\u003c\/b\u003e DIP switch selectable for upscale or downscale\u003cbr\u003e \u003cb\u003eLoad Resistance (Ω):\u003c\/b\u003e ≤(Vsupply -3.3)\/ 0.023\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/100Ω\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 3.3 to 35 Vdc\u003cbr\u003e \u003cb\u003eVoltage Drop:\u003c\/b\u003e 3.3 Vdc\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 1 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.65 W max\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;30 ms\/300 ms (selectable, provides either fast response or signal dampening as needed).\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e Better than 0.2°C or ±0.1% of selected range\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e ≤±0.02°C\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span (span = selected input range)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818404225319,"sku":"DRSL-RTD-LP-Sig-Cond","price":282.95,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818404258087,"sku":"DRSL-RTD-LP-Sig-Cond","price":282.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-rtd-lp_l_mc6aisxbqkaaidvw.jpg?v=1741345324"},{"product_id":"din-rail-conditioner-series-with-process-input-high-accuracy","title":"DIN Rail Conditioner Series with Process Input, High accuracy","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-DC2 isolated DIN rail signal conditioner provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. The DRSL-DC2 can be used for signal conversion of standard process voltage or current signals. The unit offers isolation between input, output and supply, provides surge suppression and protects control systems from transients and noise.\u003cbr\u003e\u003cbr\u003e The DRSL-DC2 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. When the input is configured for 2-wire transmitter mode, the DRSL-DC2 provides the current loop supply voltage. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 20.5 mA\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 23 mA \u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eInput Voltage Drop:\u003c\/b\u003e \u0026lt;1.5V\u003cbr\u003e \u003cb\u003e2-Wire Transmitter Supply:\u003c\/b\u003e \u0026gt;17V\/20 mA\u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 10.25V\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 11.5V\/ 0 to 5.75V\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e ≥500 kΩ\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 20.5 mA (span)\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 23 mA\/600 Ω max\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/100 Ω\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ≤28 mA\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 10V\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 10, 2 to 10, 0 to 5 and 1 to 5V\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e \u0026gt;10 kΩ min\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage (via Power Rail or Connectors):\u003c\/b\u003e 16.8 to 31.2 Vdc\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 1.2 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.4 W typical\/0.65 W max\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input\/output\/supply\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eMTBF:\u003c\/b\u003e \u0026gt;231 years, according to IEC 61709 (SN29500)\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;7 ms\u003cbr\u003e \u003cb\u003eSpan:\u003c\/b\u003e Corresponds to the presently selected DIP switch output range\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e \u0026lt;±0.05% of span\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt;±0.01% of span\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm2\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818404323623,"sku":"DRSL-DC1-DC2-Srs-Sig-Cond","price":520.22,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818404356391,"sku":"DRSL-DC1-DC2-Srs-Sig-Cond","price":520.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-dc2_l_zhegfri4n5jusro5.jpg?v=1741345346"},{"product_id":"din-rail-universal-smart-transmitter-w-led-display","title":"DIN Rail Universal Smart Transmitter w\/ LED Display","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\n\u003cp class=\"contentTitle\"\u003e \u003c\/p\u003e \u003cspan class=\"descCopyPP\"\u003e \u003c!--\u003cb\u003e\u003cspan style=\"color:blue;\" _mce_style=\"color: blue;\"\u003e Please check out our Newest Released Universal Programmable Signal Transmitter \u003ca href=\"https:\/\/www.omega.com\/pptst\/DRST-UN.html\" _mce_href=\"https:\/\/www.omega.com\/pptst\/DRST-UN.html\" class=\"blLink\"\u003e DRST-UN \u003c\/a\u003e Standard Model and \u003ca href=\"https:\/\/www.omega.com\/pptst\/DRST-UR.html\" _mce_href=\"https:\/\/www.omega.com\/pptst\/DRST-UR.html\" class=\"blLink\"\u003e DRST-UR \u003c\/a\u003e Relay Outputs Model for more advanced features with better price.\u003c\/b\u003e\u003cbr\/\u003e\u003cbr\/\u003e --\u003e The TXDIN101 is a computerized, PC programmable, galvanically isolated two-wire smart transmitter. The unit converts 13 types of thermocouple sensors; 12 types of RTD sensors, configured as 2-, 3- and 4-wires; potentiometer, resistor and millivolt inputs, single or differential—into process current loop. Integral 3% digits LED display forms a transmitter—monitor unit which is visiable in dark installations. The light intensity varies as a function of the current loop, which serves as the light energy source 24-bit A\/D converter and two microprocessors are the heart of the outstanding performance. The transmitter can be set and wired to perform differential measurement conversions of temperature sensors as well as mV sources. The output current is temperature linearized and can be set to be 4 to 20\/20 to 4mA—or any range within these limits. The current is limited to 3.9 and 22 mA.The TXDIN101 samples and updates the output current in a rate of 2 to 4 samples per second depends on the sensor type. The transmitter is fully configurable in dry-configuration mode by which the connection to PC is performed with no external power source. The configuration parameters are stored in a nonvolatile memory. Exceptional digital accuracy of typically ±0.1°C is provided for most sensors regardless of the calibrated span. Internal Pt-100 temperature sensor provides precise cold junction compensation throughout the entire ambient range. Detection of sensor breakage or disconnection of input leads, forces the output to a predefined up\/down scale value. The unit continuously monitors the sensor and automatically returns to normal operation mode when the sensor is recovered. The TXDIN101 is housed in a plastic enclosure mounted on a standard DIN rail. Special red filter is provided for optimal view.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHousing Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMaterial:\u003c\/b\u003e Plastic polycarbonate\u003cbr\u003e \u003cb\u003eScrew Connection:\u003c\/b\u003e 6 terminals\u003cbr\u003e \u003cb\u003eMounting:\u003c\/b\u003e Standard DIN rail\u003cbr\u003e \u003cb\u003eOperating Position:\u003c\/b\u003e Any\u003cbr\u003e \u003cb\u003eProtection Level:\u003c\/b\u003e IP20; UL-94-V0 flame retardant\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 85 g (0.18 lb)\u003cbr\u003e\u003cb\u003eProgramming\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSoftware Package:\u003c\/b\u003e CONCAL for COM and USB ports\u003cbr\u003e \u003cb\u003eModem Cord CONUSB:\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eLength:\u003c\/b\u003e 1.5m with USB connector for USB connection\u003cbr\u003e \u003cb\u003eConfigured Parameters:\u003c\/b\u003e Tag information, sensor type, Input range, selection of connection type, output offset, output curve correction, damping factor, burnout type, output current mode, sensor calibration \u003cbr\u003e\u003cbr\u003e\u003cdiv class=\"tableWrapPP\"\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"6\" style=\"text-align: center;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"color: white;\" bgcolor=\"#5A9FA3\"\u003e\u003cth colspan=\"6\" style=\"text-align: center;\"\u003eThermocouple and Millivolts\u003c\/th\u003e\u003c\/tr\u003e \u003ctr style=\"color: white;\" bgcolor=\"#5A9FA3\"\u003e\n\u003cth style=\"text-align: center;\"\u003e Type \u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e Input Range °C \u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e Input Range °F \u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e Minimum Span °C (°F) \u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003e Digital Accuracy \u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eD\/A Accuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e \u003cfont color=\"#a7acae\"\u003eB\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e100 to 1820\u003c\/td\u003e\n\u003ctd\u003e212 to 3308\u003c\/td\u003e\n\u003ctd\u003e200 (360)\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003ctd rowspan=\"15\" style=\"text-align: center;\"\u003e±0.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#93588e\"\u003eE\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e-200 to 1000\u003c\/td\u003e\n\u003ctd\u003e-328 to 1832\u003c\/td\u003e\n\u003ctd\u003e50 (90)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#000000\"\u003eJ\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e-200 to 1200\u003c\/td\u003e\n\u003ctd\u003e-328 to 2192\u003c\/td\u003e\n\u003ctd\u003e50 (90)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#f7ee37\"\u003eK\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e-200 to 1370\u003c\/td\u003e\n\u003ctd\u003e-328 to 2498\u003c\/td\u003e\n\u003ctd\u003e50 (90)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#000000\"\u003eL\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e-190 to 890\u003c\/td\u003e\n\u003ctd\u003e-310 to 1634\u003c\/td\u003e\n\u003ctd\u003e25 (45)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#e08c5b\"\u003eN\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e-200 to 1300\u003c\/td\u003e\n\u003ctd\u003e-328 to 2372\u003c\/td\u003e\n\u003ctd\u003e25 (45)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#c8df9a\"\u003eR\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e0 to 1760\u003c\/td\u003e\n\u003ctd\u003e32 to 3200\u003c\/td\u003e\n\u003ctd\u003e200 (360)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#c8df9a\"\u003eS\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e0 to 1760\u003c\/td\u003e\n\u003ctd\u003e32 to 3200\u003c\/td\u003e\n\u003ctd\u003e200 (360)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#78a4d1\"\u003eT\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e-200 to 400\u003c\/td\u003e\n\u003ctd\u003e-328 to 752\u003c\/td\u003e\n\u003ctd\u003e50 (90)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#939a9b\"\u003eU\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e-190 to 590\u003c\/td\u003e\n\u003ctd\u003e-310 to 1094\u003c\/td\u003e\n\u003ctd\u003e25 (45)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#ce003a\"\u003eD\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e0 to 2230\u003c\/td\u003e\n\u003ctd\u003e32 to 4046\u003c\/td\u003e\n\u003ctd\u003e25 (45)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#ce003a\"\u003eG\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e0 to 2160\u003c\/td\u003e\n\u003ctd\u003e32 to 3920\u003c\/td\u003e\n\u003ctd\u003e25 (45)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e\n\u003cfont color=\"#ce003a\"\u003eC\u003c\/font\u003e \u003c\/th\u003e\n\u003ctd\u003e15 to 2320\u003c\/td\u003e\n\u003ctd\u003e5 to 4208\u003c\/td\u003e\n\u003ctd\u003e25 (45)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e+0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e Millivolt Input \u003c\/th\u003e\n\u003ctd\u003e-145 to 145\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e2 mV\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±51 uV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e Mode \u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003eT\/C: Single or differential sensor\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"text-align: center;\"\u003eVoltage: Single or differential ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e Cold Junction \u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003eInternal Pt-100 sensor\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e C.J. Accuracy \u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e±0.5°C (±0.9°F)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003e Sampling Rate \u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003eT\/C: Single: 4, Differential: 2 (S\/sec)\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"text-align: center;\"\u003eVoltage: 4, Differential: 2 (S\/sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e\u003cfont size=\"1\"\u003e\u003cdiv align=\"left\"\u003e\u003ci\u003e\u003cb\u003eNote:\u003c\/b\u003e For maximum accuracy for T\/C input, all the above error components should be accumulated.\u003c\/i\u003e\u003c\/div\u003e\u003c\/font\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818404487463,"sku":"TXDIN101-Transmitter","price":1167.99,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818404520231,"sku":"TXDIN101-Transmitter","price":1167.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/txdin101_l_tig4viisxnutieza.jpg?v=1741345373"},{"product_id":"dr-i4-series-signal-conditioner","title":"DR-I4 Series Signal Conditioner","description":"\u003cp\u003eThe DR-I4 Signal Conditioner is a reliable front-end module designed to convert sensor outputs into processed signals ideal for monitoring systems. It accepts raw inputs—such as mV, mA, or RTD—and conditions them into stable standardized outputs. Users can fine-tune zero and span for calibration, while the compact unit fits neatly into control cabinets or instrumentation racks. Built for accuracy and stability, the DR-I4 strengthens signal integrity for further analysis or logging, ensuring consistent performance in industrial data acquisition systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eConverts raw sensor signal to standardized formats (e.g., mA)\u003c\/p\u003e\n\n\u003cp\u003eAdjustable zero\/span for precise calibration\u003c\/p\u003e\n\n\u003cp\u003eCompact build ideal for panel or cabinet installation\u003c\/p\u003e\n\n\u003cp\u003eEnhances signal reliability for monitoring systems\u003c\/p\u003e\n\n\u003cp\u003eSuitable for a wide range of sensor types and instruments\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818404651303,"sku":"DR-I4-Series","price":476.12,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818404684071,"sku":"DR-I4-Series","price":476.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dr-i4_450_orzcmuzqsewrq9hg.jpg?v=1741345393"},{"product_id":"din-rail-signal-conditioner-for-bipolar-process-inputs","title":"DIN Rail Signal Conditioner for Bipolar Process Inputs","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-DC4 bipolar isolated DIN rail signal conditioner provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. The DRSL-DC4 can be used for signal conversion of standard bipolar analog process signals into unipolar analog signals. The unit offers isolation between input, output and supply, provides surge suppression and protects control systems from transients and noise.\u003cbr\u003e\u003cbr\u003e The DRSL-DC4 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e ±10 mA, ±20 mA\u003cbr\u003e \u003cb\u003eFunctional Range, Current Input:\u003c\/b\u003e -23 to 23 mA\u003cbr\u003e \u003cb\u003eInput Voltage Drop:\u003c\/b\u003e \u0026lt;1V @ 23 mA\u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Ranges:\u003c\/b\u003e ±5V, ±10V\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e -11.5 to 11.5V\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e ≥1 MΩ\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA, 4 to 20 mA\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 23 mA\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 23 mA\/600 Ω max (per channel)\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.002% of span\/100 Ω\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ≤28 mA\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 10V, 2 to 10V, 0 to 5V, 1 to 5V\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 11.5V\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e \u0026gt;10 kΩ min\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage (via Power Rail or Connectors):\u003c\/b\u003e 16.8 to 31.2 Vdc\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 0.8 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.4 W typical\/0.65 W max\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input\/output\/supply\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eMTBF:\u003c\/b\u003e \u0026gt;241 years, according to IEC 61709 (SN29500)\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eCut-Off Frequency (3 dB):\u003c\/b\u003e \u0026gt;100 Hz or 10 Hz (selectable via DIP-switch)\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;7 ms or \u0026lt;44 ms\u003cbr\u003e \u003cb\u003eSpan:\u003c\/b\u003e Corresponds to presently selected DIP switch output range\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e \u0026lt;±0.05% of span\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt;±0.01% of span\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818404978983,"sku":"DRSL-DC4-Bipolar-Sig-Cond","price":501.3,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818405011751,"sku":"DRSL-DC4-Bipolar-Sig-Cond","price":501.3,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-dc4_l_nstwctk4rirvlvia.jpg?v=1741345416"},{"product_id":"din-rail-conditioners-convert-ma-or-v-inputs-to-ma-or-voltage","title":"DIN Rail Conditioners Convert mA or V Inputs to mA or Voltage","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e \u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003e \u003cul\u003e\n\u003cli\u003eAmplify , Convert, or Scale Process Signals\u003c\/li\u003e \u003cli\u003eIsolate Single-Ended (Common Ground) PLC Inputs\u003c\/li\u003e \u003cli\u003eInterface Process Signals with Panel Meters, PLCs, Recorders, Data Acquisition, DCS, and SCADA Systems\u003c\/li\u003e \u003c\/ul\u003e \u003cbr\u003e\u003cbr\u003e The DMD4380 accepts a dc voltage or current input and provides an optically isolated dc voltage or current output that is linear to the input. It provides filtering, amplifies, and converts the input signal to the selected dc voltage or current output that you select. The 3-way 1200V isolation eliminates ground loops, common mode voltages and greatly reduces noise pick-up. Standard features include a 15 Vdc loop power supply and a 20 Vdc loop supply for the output. The power supplies can also be wired to sink or source which allows the DMD4380 to be used with any combination of powered or unpowered mA inputs and powered or unpowered mA outputs including passive mA devices. Features such as red and green LEDs that vary in intensity to show input and output activity and an output test button help make set-up and troubleshooting fast and easy. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eInput Ranges:\u003c\/b\u003e Field selectable ranges via switch settings\u003cbr\u003e    \u003cb\u003eVoltage:\u003c\/b\u003e 0-10 mVdc to 0-50 Vdc\u003cbr\u003e    \u003cb\u003eBipolar Voltage:\u003c\/b\u003e ±50 mVdc to ±10 Vdc\u003cbr\u003e    \u003cb\u003eCurrent:\u003c\/b\u003e 0-200 uAdc to 0-50 mAdc\u003cbr\u003e \u003cb\u003eInput Impedance (Voltage):\u003c\/b\u003e\u003cbr\u003e    \u003cb\u003eVoltage:\u003c\/b\u003e 1 MΩ minimum\u003cbr\u003e    \u003cb\u003eCurrent:\u003c\/b\u003e 50Ω typical\u003cbr\u003e    \u003cb\u003eVoltage Burden:\u003c\/b\u003e 1 Vdc at 20 mA\u003cbr\u003e \u003cb\u003eInput Loop Power Supply:\u003c\/b\u003e 15 Vdc ±10%, regulated, 25 mAdc; max ripple, less than 10 mV RMS may be selectively wired for sinking or sourcing\u003cbr\u003e \u003cb\u003eOutput Ranges:\u003c\/b\u003e Switch Selectable, Field Rangeable\u003cbr\u003e    \u003cb\u003eVoltage (10 mA max):\u003c\/b\u003e 0-1 to 0-10 Vdc\u003cbr\u003e    \u003cb\u003eBipolar Voltage (10 mA max):\u003c\/b\u003e ±5 to ±10 Vdc\u003cbr\u003e    \u003cb\u003eCurrent:\u003c\/b\u003e 0-2 mA to 0-25 mA\u003cbr\u003e    \u003cb\u003eCompliance, Drive @ 20 mA:\u003c\/b\u003e 20V,1000 Ù drive\u003cbr\u003e    \u003cb\u003eOutput Offset:\u003c\/b\u003e ±100% of span in 15% increments\u003cbr\u003e \u003cb\u003eOutput Linearity:\u003c\/b\u003e Better than ±0.1% of span\u003cbr\u003e \u003cb\u003eOutput Zero and Span:\u003c\/b\u003e Multi-turn potentiometers to compensate for load and lead variations, ±15% of span adjustment range typical\u003cbr\u003e \u003cb\u003eOutput Loop Power Supply:\u003c\/b\u003e 20 Vdc nominal, regulated, 25 mAdc; max ripple, less than 10 mV RMS; may be selectively wired for sinking or sourcing \u003cbr\u003e \u003cb\u003eOutput Ripple:\u003c\/b\u003e \u0026lt;10 mV rms\u003cbr\u003e \u003cb\u003eFunction Test Button:\u003c\/b\u003e Sets output to test level when pressed; adjustable 0 to 100% of span via potentiometer. Factory default is approx. 50% of span\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e 70 ms typical\u003cbr\u003e \u003cb\u003eCommon Mode Rejection:\u003c\/b\u003e 120 db minimum\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e 1200 Vrms minimum, 3-way isolation, power to input, power to output and input to output\u003cbr\u003e \u003cb\u003eOperating Temperature Range:\u003c\/b\u003e -10 to 60°C (14 to 140°F)\u003cbr\u003e \u003cb\u003eThermal Stability:\u003c\/b\u003e Better than ±0.02% of span per °C\u003cbr\u003e \u003cb\u003eStd. Power:\u003c\/b\u003e 80 to 265 Vac, 50\/60 Hz or 85 to 300 Vdc, 2 W maximum\u003cbr\u003e \u003cb\u003eLow Voltage 'DC' Option:\u003c\/b\u003e 9 to 30 Vdc or 10 to 32 Vac\u003cbr\u003e \u003cb\u003eMounting:\u003c\/b\u003e Mounts to standard 35 mm DIN rail\u003cbr\u003e \u003cb\u003eEnvironmental Protection:\u003c\/b\u003e IP40\u003cbr\u003e \u003cb\u003eConnections:\u003c\/b\u003e Four 4-terminal removable connectors 14 AWG max wire size\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 22.5 W x 117 H x 122 mm D (0.89 x 4.62 x 4.81') height includes connectors\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 150 g (5.3 oz)\u003cbr\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818405994791,"sku":"DMD4380-Series-Sig-Cond","price":1053.89,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818406027559,"sku":"DMD4380-Series-Sig-Cond","price":1053.89,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dmd4380_l_9drhlfjqpehk361y.jpg?v=1741345437"},{"product_id":"din-rail-signal-conditioner-series-with-model-specific-input-type","title":"DIN Rail Signal Conditioner Series with Model Specific Input Type","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The CCT series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 0\/4 to 20 mA, or 0 to 10 Vdc. The CCT series features a modern housing design, that is easily mounted on standard DIN rails. Connections are safely and securely made, with input and output connections on the opposite sides of the module.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eInternal Design\u003c\/b\u003e\u003cbr\u003e The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. The units are supplied with 110 Vac power standard, Consult sales for 220 Vac, and 24 Vdc power.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eIsolation\u003c\/b\u003e\u003cbr\u003e The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOutputs\u003c\/b\u003e\u003cbr\u003e Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc.\u003cbr\u003e\u003cbr\u003e Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies)\u003cbr\u003e \u003cb\u003eOutput:\u003c\/b\u003e 4 to 20 mA and 0 to 10 Vdc standard; 0 to 20 mA via jumper select\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e ≤0.2% or ≤0.3,%, depending on the model\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e ≤250 ms\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e 2 kVeff\u003cbr\u003e \u003cb\u003eRipple:\u003c\/b\u003e ≤0.5%\u003cbr\u003e \u003cb\u003eBandpass: \u003c\/b\u003e1.5 Hz (-3 dB)\u003cbr\u003e \u003cb\u003eOperating Ambient:\u003c\/b\u003e -10 to 60°C (14 to 140°F)\u003cbr\u003e \u003cb\u003eStorage Ambient:\u003c\/b\u003e -30 to 80°C (-22 to 176°F)\u003cbr\u003e \u003cb\u003eTemperature Coefficient\u003c\/b\u003e: ≤0.015%\/°C\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 1.5 VA max\u003cbr\u003e \u003cb\u003eEnclosure:\u003c\/b\u003e Polycarbonate, RAL 7032; UL 94 V-1, IP40 protection\u003cbr\u003e \u003cb\u003eTerminal Housing:\u003c\/b\u003e Polycarbonate, UL 94-2, IP20 protection\u003cbr\u003e \u003cb\u003eMax Wire Size:\u003c\/b\u003e 4 mm² (14 AWG)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 75 H x 45 W x 110 mm D (2.95' x 1.77' x 4.33')\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 270 g (0.6 lb)\u003cbr\u003e \u003cb\u003eMounting:\u003c\/b\u003e DIN rail 46277 and EN 50022 (35 x 7.5 mm)\u003cbr\u003e\u003cbr\u003e \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818406388007,"sku":"CCT-Series-Sig-Cond","price":843.86,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818406420775,"sku":"CCT-Series-Sig-Cond","price":843.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/cct_l_xenwbbfnl8inrtam.jpg?v=1741345462"},{"product_id":"din-rail-load-cell-input-signal-conditioner","title":"DIN Rail Load Cell Input Signal Conditioner","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRF series DIN rail signal conditioners are designed to accept a broad range of input signals, such as AC and DC voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 4 to 20 mA, or 0 to 10 Vdc. The DRF series feature a modern housing design, that is easily mounted on standard 35 mm DIN rails. Connections are safely and securely made through pluggable screw terminal connectors, with input and output connections on the opposite sides of the module.\u003cbr\u003e\u003cbr\u003e The DRF-LC signal conditioner accepts a load cell input and provides an isolated 0 to 10 Vdc or 4 to 20 mA output. Models are available with three different power options, 24 Vdc, 120 Vac and 240 Vac.\u003cbr\u003e\u003cbr\u003e The DRF-LC are ideally suited for industrial applications. The DRF-LC feature galvanic isolation between input, output and power up to 3500 Veff (model specific). Module response time is 75 ms or less.\u003cbr\u003e\u003cbr\u003e The FAR-1 power supply is an ideal companion product for the DRF-LC. It provides a regulated 10Vdc output that may be used to power up to 4 load cells.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eRange Code Table\u003cbr\u003e\u003c\/strong\u003e \u003cdiv class=\"tableWrapPP\"\u003e\u003ctable width=\"250\" cellspacing=\"0\" cellpadding=\"2\" border=\"1\" bordercolor=\"#000000\"\u003e \u003ctbody\u003e\n\u003ctr bgcolor=\"7CD0E0\"\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eRange Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\"\u003e10MV\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0 to 10 mV\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\"\u003e20MV\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0 to 20 mV\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd align=\"center\"\u003e30MV\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0 to 30 mV\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e \u003cdiv class=\"tableWrapPP\"\u003e\u003ctable width=\"750\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\"\u003e \u003ctbody\u003e\n\u003ctr\u003e \u003ctd width=\"350\"\u003e \u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e \u003cb\u003eAccuracy: \u003c\/b\u003e\u0026lt;0.2% full scale\u003cbr\u003e \u003cb\u003eLinearity: \u003c\/b\u003e\u0026lt;\u0026lt;0.1% full scale\u003cbr\u003e \u003cb\u003eThermal Drift: \u003c\/b\u003e250 ppm\/°C typical (max \u0026lt;200ppm\/°C)\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e \u0026lt;75 mS (90% of signal)\u003cbr\u003e \u003cb\u003eBandwith:\u003c\/b\u003e 20 Hz (-3dB)\u003cbr\u003e \u003cb\u003ePretare:\u003c\/b\u003e 50%, 25% and 0% by jumpers\u003cbr\u003e Impedance: 5 M Ω\u003cbr\u003e \u003cb\u003eOver Range Protection:\u003c\/b\u003e 15 V max differential input\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003ePower:\u003c\/strong\u003e 24 Vdc ±10%, 230 Vac ±10% 50\/60 Hz, 115 Vac ±10% 50\/60 Hz\u003cbr\u003e \u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u0026lt;3.8 VA\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eOutput: \u003c\/strong\u003e4 to 20 mA and 0 to 10 Vdc\u003cbr\u003e \u003cstrong\u003eMaximum Voltage Output: \u003c\/strong\u003e11 Vdc approx.\u003cbr\u003e \u003cstrong\u003eMinimum Voltage Output:\u003c\/strong\u003e -1 Vdc approx.\u003cbr\u003e \u003cstrong\u003eMinimum Load Resistance (Voltage): \u003c\/strong\u003e\u003cu\u003e\u0026gt;\u003c\/u\u003e1 KΩ \u003cstrong\u003eMaximum Current Output:\u003c\/strong\u003e 22 mA approx.\u003cbr\u003e \u003cstrong\u003eMaximum Current Output:\u003c\/strong\u003e -1.5 mA approx.\u003cbr\u003e \u003cstrong\u003eMaximum Load Resistance (current):\u003c\/strong\u003e \u003cu\u003e\u0026gt;\u003c\/u\u003e400 Ω \u003c\/td\u003e \u003ctd width=\"20\"\u003e \u003c\/td\u003e \u003ctd valign=\"top\"\u003e\n\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eElectrical Connections: \u003c\/strong\u003ePlug-in screw terminals\u003cbr\u003e \u003cstrong\u003eProtection:\u003c\/strong\u003e IP-30\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eMECHANICAL DIMENSIONS\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cbr\u003e (DC Powered Models): 120 g (4.2 oz)\u003cbr\u003e (AC Powered Models): 200 g (7 oz)\u003cbr\u003e \u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cbr\u003e (DC Powered models):\u003cbr\u003e 110 H x 22.5 W x 93 mm D (4.3 x 0.9 x 3.7\")\u003cbr\u003e (AC Powered models):\u003cbr\u003e 110 H x 37 W x 93 mm D (4.3 x 1.46 x 3.7\")\u003cbr\u003e \u003cstrong\u003eOperating Temperature: \u003c\/strong\u003e0 to 60°C (32 to 140°F)\u003cbr\u003e \u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -20 to 70°C (-4 to 158°F) \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818406715687,"sku":"DRF-LC-Series-Sig-Cond","price":591.05,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818406748455,"sku":"DRF-LC-Series-Sig-Cond","price":591.05,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drf-lc_yorlndsvzjws8qp0.jpg?v=1741345484"},{"product_id":"din-rail-ac-current-and-voltage-transmitter","title":"DIN Rail AC Current and Voltage Transmitter","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e \u003cb\u003eApplication\u003c\/b\u003e\u003cbr\u003e • The 0 to 5 AAC RMS range makes it possible to accurately measure a typical current transformer.\u003cbr\u003e • The 0 to 300 Vac RMS range allows accurate supply voltage monitoring.\u003cbr\u003e • DRST-AC measures standard input ranges, and can be freely configured to customer-defined input range.\u003cbr\u003e • Converts narrow AC current\/voltage inputs to wide bipolar or unipolar outputs, e.g. 0 to 1 VAMS input = ±10 volt or 4 to 20 mA output with a minimum span of 0.5 AAC RMS or 0.5 Vac RMS.\u003cbr\u003e • Configurable input limits control the output value for increased safety.\u003cbr\u003e \u003cb\u003eTechnical Characteristic\u003c\/b\u003e\u003cbr\u003e • The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.\u003cbr\u003e • Possibility of output safety feedback by selecting S4 to 20 mA output.\u003cbr\u003e • The current output can drive up to 800 Ω, with an adjustable response time of 0.0 to 60.0 seconds.\u003cbr\u003e • Exceptional mA output load stability of \u0026lt;0.001% of span\/100 Ω\u003cbr\u003e. • Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.\u003cbr\u003e • Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.\u003cbr\u003e • Each unit is tested to a high 2.3 kVac, 3-port galvanic isolation level.\u003cbr\u003e • Excellent signal to noise ratio of \u0026gt; 60 dB.\u003cbr\u003e \u003cb\u003eMounting\/Installation\/Programming\u003c\/b\u003e\u003cbr\u003e • Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.\u003cbr\u003e • Configuration, monitoring, 2-point process calibration and more are accomplished using either the 4501 detachable display or the 4511 detachable digital communication enabler.\u003cbr\u003e • All programming can be password-protected.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEnvironmental Conditions\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -20 to 60°C\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e \u0026lt; 95% RH (non-cond.)\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation In:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage cat. II\u003cbr\u003e \u003cb\u003eMechanical Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions (HxWxD):\u003c\/b\u003e 109 x 23.5 x 104 mm\u003cbr\u003e \u003cb\u003eDimensions (HxWxD) w\/ 4501\/4511:\u003c\/b\u003e 109 x 23.5 x 116 \/ 131 mm\u003cbr\u003e \u003cb\u003eWeight Approx:\u003c\/b\u003e 250 g\u003cbr\u003e \u003cb\u003eWeight incl. 4501\/4511 (approx.):\u003c\/b\u003e 285 g \/ 350 g\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715\/35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 to 2.08 mm 2 AWG 26 to 14 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm\u003cbr\u003e \u003cb\u003eVibration:\u003c\/b\u003e IEC 60068-2-6\u003cbr\u003e \u003cb\u003e2 to 13.2 Hz:\u003c\/b\u003e ±1 mm\u003cbr\u003e \u003cb\u003e13.2 to 100 Hz:\u003c\/b\u003e ±0.7 g\u003cbr\u003e \u003cb\u003eCommon Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage, Universal:\u003c\/b\u003e 21.6 to 253 Vac, 50 to 60 Hz or 19.2 to 300 Vdc\u003cbr\u003e \u003cb\u003eMax. Required Power:\u003c\/b\u003e ≤ 1.8 W nom.\u003cbr\u003e \u003cb\u003eInternal Power Dissipation:\u003c\/b\u003e ≤ 2.5 W\u003cbr\u003e \u003cb\u003eIsolation Voltage\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTest Voltage:\u003c\/b\u003e 2.3 kVac \u003cb\u003eWorking Voltage:\u003c\/b\u003e 250 Vac (reinforced)\/500 Vac (basic)\u003cbr\u003e \u003cb\u003eResponse Time\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eResponse Time (0...90%, 100...10%):\u003c\/b\u003e \u0026lt; 0.75 s\u003cbr\u003e \u003cb\u003eProgramming:\u003c\/b\u003eCommunication enabler\/Programming front DRSL-DISPLAY\u003cbr\u003e \u003cb\u003eSignal Dynamics, Input:\u003c\/b\u003e 20 bit\u003cbr\u003e \u003cb\u003eSignal Dynamics, Output:\u003c\/b\u003e 18 bit \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt; 60 dB\u003cbr\u003e \u003cb\u003eOutput Referred Common Mode Rejection Ratio\"\u003c\/b\u003e 0.02 ppm\/VHz \u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e Better than 0.3% of selected range*\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt; ±0.5% of span*\u003cbr\u003e Extended EMC immunity: NAMUR NE21, A Criterion, Burst: \u0026lt; ±1% of span*\u003cbr\u003e \u003cb\u003eOf Span:\u003c\/b\u003e = of selected standard range\u003cbr\u003e \u003cb\u003eInput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 5 AAC\/40 to 400 Hz\u003cbr\u003e \u003cb\u003eMaximum Input Limit:\u003c\/b\u003e 6.00 AAC @ 40°C\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 0.5; 0 to 1; 0 to 2.5 and 0 to 5 AAC\u003cbr\u003e Custom Configurable Signal Range: 0 to 5 AAC\/40 to 400 Hz\u003cbr\u003e \u003cb\u003eMin. Measurement Range (Span):\u003c\/b\u003e 0.5 AAC\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e Nom. \u0026lt; 0.07 Ω\u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 300 Vac\/40 to 400 Hz\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e0 to 0.5, 0 to 1, 0 to 2.83, 0 to 5, 0 to 120, 0 to 230 and 0 to 300 Vac\u003cbr\u003e Custom Configurable Signal Range: 0 to 300 Vac\/40 to 400 Hz\u003cbr\u003e \u003cb\u003eMin. Measurement Range (Span):\u003c\/b\u003e 0.5 Vac\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003eNom. 3 MΩ || 100 pF\u003cbr\u003e \u003cb\u003eOutput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eActive Unipolar and Bipolar mA Ooutput\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Ranges:\u003c\/b\u003e 0 to 20, 4 to 20 and S4 to 20 mA\u003cbr\u003e \u003cb\u003eProgrammable Ranges:\u003c\/b\u003e ±10 and ±20 mA\u003cbr\u003e \u003cb\u003eProgrammable Ranges:\u003c\/b\u003e Direct or Inverted Action\u003cbr\u003e \u003cb\u003eLoad (@ Current Output):\u003c\/b\u003e ≤ 800 Ω\u003cbr\u003e \u003cb\u003eV-Curve Function, Active Signals, 100-0-100%:\u003c\/b\u003e 20-0 to 20 mA\u003cbr\u003e \u003cb\u003ePassive 2-Wire mA Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Ranges:\u003c\/b\u003e 0 to 20 and 4 to 20 mA\u003cbr\u003e \u003cb\u003eProgrammable Ranges:\u003c\/b\u003e Direct or Inverted action\u003cbr\u003e \u003cb\u003eV-Curve Function, 100-0 to 100%:\u003c\/b\u003e 20-0 to 20 mA\u003cbr\u003e \u003cb\u003eExternal Loop Supply:\u003c\/b\u003e 3.5 to 30 V\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 23 mA (unipolar)\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e -23 to +23 mA (bipolar)\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ≤ 28 mA (unipolar)\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ± 28 mA (bipolar)\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤ 0.001% of span \/ 100 Ω\u003cbr\u003e \u003cb\u003eResponse Time, Programmable:\u003c\/b\u003e 0.0 to 60.0 s\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0\/0.2 to 1; 0\/1 to 5 ; 0\/2 to 10; 1 to 0.2\/0; 5 to 1\/0; 10 to 2\/0 V\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e ±1, ±5 and ±10 V\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e Direct or Inverted Action\u003cbr\u003e \u003cb\u003eV-Curve Function, 100-0-100%:\u003c\/b\u003e1-0-1, 5-0-5 and 10-0-10 V\u003cbr\u003e \u003cb\u003eLoad (@ Voltage Output):\u003c\/b\u003e ≥ 500 kΩ \u003cb\u003eResponse Time, Programmable:\u003c\/b\u003e 0.0 to 60.0 s\u003cbr\u003e \u003cb\u003eObserved Authority Requirements\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEMC:\u003c\/b\u003e 2014\/30\/EU\u003cbr\u003e \u003cb\u003eLVD:\u003c\/b\u003e 2014\/35\/EU\u003cbr\u003e \u003cb\u003eRoHS:\u003c\/b\u003e 2011\/65\/EU\u003cbr\u003e \u003cb\u003eApprovals\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eUL:\u003c\/b\u003e UL 508 \/ C22.2 no. 14\u003cbr\u003e \u003cb\u003eNB:\u003c\/b\u003e For custom configurable signal ranges, general accuracy and EMC specifications are 0.3% of full scale \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818407567655,"sku":"DRST-AC-Srs-Sig-Cond","price":646.25,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818407600423,"sku":"DRST-AC-Srs-Sig-Cond","price":646.25,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drst-ac_l_kdlf38q5atgkjxnq.jpg?v=1741345506"},{"product_id":"din-rail-configurable-conditioners-with-model-specific-input-type","title":"DIN Rail Configurable Conditioners with Model Specific Input Type","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cp\u003e\u003cstrong\u003ePlease check out Newest Released DRST Family including Universal Programmable Signal Transmitter \u003ca class=\"blLink\" href=\"..\/p\/DRST-UN\"\u003e DRST-UN \u003c\/a\u003e Standard Model, \u003ca class=\"blLink\" href=\"..\/p\/DRST-UR\"\u003e DRST-UR \u003c\/a\u003e Relay Outputs Model, \u003ca class=\"blLink\" href=\"..\/p\/DRST-AC\"\u003e DRST-AC \u003c\/a\u003e AC Inputs Model, and \u003ca class=\"blLink\" href=\"..\/p\/DRST-FR\"\u003e DRST-FR \u003c\/a\u003e Frequency Inputs Model for more advanced features with better price.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n\nThe DRG Series signal conditioner modules accept a wide variety of input signals such as thermocouples, RTDs, strain gages, DC voltages\/currents, AC voltages\/currents, frequency and potentiometers and produce a proportional conditioned process output. The inputs and outputs are both field configurable and offer flexible wide ranging capability. The slim housing mounts on a DIN rail and is ideal for high density installation. All modules provide 1800 Vdc isolation between the input, output and power supply. One advantage of the DRG series is the field configurable input and output ranges. Each module can be set to a number of ranges by dip switch selection. Wide ranging precision zero and span potentiometers provide even further adjustment. The signal conditioners may be set for an almost limitless number of ranges. Range adjustment requires the use of a calibrator or reference source.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eDRG-SC-TC Thermocouple Signal Conditioner\u003c\/strong\u003e\u003cbr\u003e\nThe DRG-SC-TC is a DIN rail mount thermocouple input signal conditioner. It can be field configured for over 60 different thermocouple temperature ranges. The output is linear to temperature and can be set for either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA. Zero and span pots allow 50% adjustability of offset and span turn down within each of the ranges. For example the 500-1000°C range could be offset and turned down to provide a 4-20 mA signal representing 750-1000°C.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eThe DRG-SC-DC DC Input Signal Conditioner\u003c\/strong\u003e\u003cbr\u003e\nThe DRG-SC-DC is a DIN rail mount DC voltage and current input signal conditioning module. The input can be field configured for any one 12 voltage ranges from 10 mV to 100 V or 6 current ranges from 1 mA to 100 mA. The output is linear to the input and can be set to either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4- 20 mA for the DRG-SC-DC-U (unipolar outputs) and -5 V to +5 V or -10 V to +10 V for the DRG-SC-DC-B (bipolar outputs). Zero and span pots allow 50% adjustability of offset and span turn down within each of the ranges. For example the 0-2 mA input range could be turned down to 0-1 mA and provide a full scale output signal (e.g. 4-20 mA).\u003cbr\u003e\n\u003cstrong\u003eInput Ranges (UNIPOLAR AND BIPOLAR)\u003c\/strong\u003e\u003cbr\u003e\nVoltages: 20 mV, 50 mV, 100 mV, 200 mV 500 mV, 1 V, 2 V, 5 V, 10 V, 25 V, 50 V, 100 V\u003cbr\u003e\nCurrent: 2 mA, 5 mA, 10 mA, 20 mA, 50 mA, 100 mA\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eDRG-SC-BG Bridge\/Strain Gage Input Signal Conditioner\u003c\/strong\u003e\u003cbr\u003e\nThe DRG-SC-BG is a DIN rail mount bridge or strain gage input signal conditioning module. The field configurable input and output offers flexible, wide ranging capability for bridge or strain gage applications from 0.5 mV\/V to over 50 mv\/V. Wide ranging, precision zero and span pots allow 50% adjustability of offset and gain within each of the 11 switch selectable input ranges. The output can be set for either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA. This flexibility, combined with an adjustable (1 to 10 Vdc) bridge excitation source, provides the user a reliable, accurate instrument to isolate and condition virtually any bridge or strain gage input.\u003cbr\u003e\n\u003cstrong\u003eInput Ranges\u003c\/strong\u003e\u003cbr\u003e\n0-10 mV, 0-20 mV, 0-50 mV, 0-100 mV, 0-200 mV,\u003cbr\u003e\n±5 mV, ±10 mV, ±20 mV, ±50 mV, ±100 mV, ±200 mV\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eDRG-SC-RTD RTD Input Signal Conditioner\u003c\/strong\u003e\u003cbr\u003e\nThe DRG-SC-RTD is a DIN rail mount RTD input signal conditioning module. It accepts a wide variety of RTDs including 100, 500 and 1000 Ohm Platinum RTDs as well as 10, 25 and 100 Ohm copper. It works with RTDs with α = 0.00385Ω\/Ω\/°C or 0.00392Ω\/Ω\/°C The input can be field configured for any one of up to sixteen temperature ranges. The output is linear to temperature and can be set for either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA.\u003cbr\u003e\n\u003cstrong\u003eInput Ranges (°C):\u003c\/strong\u003e\u003cbr\u003e\nPT100, PT500 \u0026amp; PT1000: -200 to 600, -200 to 400,\u003cbr\u003e\n-100 to 400, -200 to 260, -200 to 0, -200 to -100,\u003cbr\u003e\n-100 to 260, -100 to 100, -50 to 50, -18 to 50,\u003cbr\u003e\n-18 to 100, -18 to 260, -18 to 300, -18 to 400,\u003cbr\u003e\n-18 to 500, -18 to 600\u003cbr\u003e\nCu10, Cu25 \u0026amp; Cu100: -200 to 260,-200 to 0,\u003cbr\u003e\n-200 to -100, -100 to 260, -100 to 100, -50 to 50,\u003cbr\u003e\n-18 to 50, -18 to 100, -18 to 260\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eDRG-SC-FR Frequency Input Signal Conditioner\u003c\/strong\u003e\u003cbr\u003e\nThe DRG-SC-FR is a DIN rail mount frequency input signal conditioning module. The field configurable input and output offers flexible, wide ranging capability for a variable frequency drives, magnetic pickups, turbine meters and other pulse or frequency output transducers. The output can be set for either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA. The DRG-SC-FR can be configured for virtually any frequency input to DC signal output within the ranges specified. Calibration utilizes technology where the user simply applies minimum and maximum input frequencies, touching a recessed button to configure the minimum and maximum output range.\u003cbr\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e 2 Hz to 10,000 Hz, 50 mVp to 150 Vrms\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eDRG-SC-PT Potentiometer Input Signal Conditioner\u003c\/strong\u003e\u003cbr\u003e\nThe DRG-SC-PT is a DIN rail mount potentiometer input signal conditioning module. The input provides a constant voltage and is designed to accept any three-wire potentiometer from 100 . to 100 K.. The field configurable output can be set for either 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA. Wide ranging, precision zero and span pots, used in conjunction with DIP switches, allow 80% adjustability of offset and gain to transmit a full scale output from any 20% portion of the potentiometer input.\u003cbr\u003e\n\u003cstrong\u003eInput Range\u003c\/strong\u003e: 100Ω to 100 KΩ\u003c\/p\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818408059175,"sku":"DRG-SC-Series-Sig-Cond","price":1044.54,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818408091943,"sku":"DRG-SC-Series-Sig-Cond","price":1044.54,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drg-sc_l_gx1xqn1a0pslmhlc.jpg?v=1741345528"},{"product_id":"din-rail-dc-current-signal-splitters-w-dual-output","title":"DIN Rail DC Current Signal Splitters w\/ Dual Output","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSP-I Series DC current signal splitters accept one 4 to 20 mA current input and provide two optically isolated 4 to 20 mA current outputs that are linearly related to the 4 to 20 mA current input. This provides an economical solution when one signal must be sent to two different devices. Typical applications include isolation, output splitting, output device separation and redundancy (i.e. to prevent failure of the entire loop if one device fails), or a combination of these. The input signal is filtered, amplified, split, and then passed through an opto-coupler to the output stages. Full 4-way isolation (input, output 1, output 2, power) make this module useful for ground loop elimination, common mode signal rejection,and noise pickup reduction.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Range:\u003c\/b\u003e 4 to 20 mA\u003cbr\u003e \u003cb\u003eInput Impedance:\u003c\/b\u003e 50 Ω typical\u003cbr\u003e \u003cb\u003eInput Loop Power Supply:\u003c\/b\u003e 15 Vdc ±10%, regulated, 25 mA; May be selectively wired for sinking or sourcing mA input\u003cbr\u003e \u003cb\u003eLoop Status LEDs:\u003c\/b\u003e Variable brightness LEDs indicate I\/O loop level and status; One for input, one for each output\u003cbr\u003e \u003cb\u003eOutput\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOutput Range:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003e(Output 1 and Output 2):\u003c\/b\u003e 4 to 20 mA; 20V compliance, 1000 Ω at 20 mA\u003cbr\u003e \u003cb\u003eOutput Linearity:\u003c\/b\u003e Better than ±0.1% of span\u003cbr\u003e \u003cb\u003eOutput Zero and Span:\u003c\/b\u003e Multi-turn zero and span potentiometers for each output channel to compensate for load and lead variations; ±15% of span adjustment range typical\u003cbr\u003e \u003cb\u003eOutput Loop Power Supplies:\u003c\/b\u003e One for each output channel; 20 Vdc nominal, regulated, 25 mA may be selectively wired for sinking or sourcing mA output\u003cbr\u003e \u003cb\u003eOutput Ripple and Noise:\u003c\/b\u003e Less than 10 mVRMS\u003cbr\u003e \u003cb\u003eOutput Functional Test:\u003c\/b\u003e Front buttons set each output to test level when pressed; Each test level potentiometer adjustable 0 to 100% of span\u003cbr\u003e \u003cb\u003eGeneral\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e 70 milliseconds typical\u003cbr\u003e \u003cb\u003eCommon Mode Rejection:\u003c\/b\u003e 120 dB minimum\u003cbr\u003e \u003cb\u003eIsolation (Full 4-Way Isolation):\u003c\/b\u003e Input 1, output 1, output 2, power; 1200 VRMS minimum\u003cbr\u003e \u003cb\u003eAmbient Temperature Range:\u003c\/b\u003e -10 to 60°C (14 to 140°F)\u003cbr\u003e \u003cb\u003eStability:\u003c\/b\u003e Better than ±0.04% of span per °C\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDRSP-I:\u003c\/b\u003e 60 to 265 Vac, 50\/60 Hz or 85 to 300 Vdc, 6 W maximum\u003cbr\u003e \u003cb\u003eDRSP-I-DC:\u003c\/b\u003e 9 to 30 Vdc or 10 to 32 Vac 50\/60 Hz, 6 W maximum\u003cbr\u003e \u003cb\u003eHousing:\u003c\/b\u003e IP40, mounts to standard 35 mm (1.37\") DIN rail\u003cbr\u003e \u003cb\u003eConnectors:\u003c\/b\u003e Eight 4-terminal removable connectors; 14 AWG maximum wire size\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 45 W x 117 H x 122 mm D (1.78 x 4.62 x 4.81\"); height includes connectors \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818408681767,"sku":"DRSP-I-Srs-DC-Splitter","price":1436.4,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818408714535,"sku":"DRSP-I-Srs-DC-Splitter","price":1436.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsp-i_l_k3b5cqizwtghgzoq.jpg?v=1741345554"},{"product_id":"din-rail-isolated-repeater-splitter-for-process-signals","title":"DIN Rail Isolated Repeater\/Splitter for Process Signals.","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-SP2 isolated signal conditioner\/splitter provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. Two process outputs are provided which mirror the single process input.\u003cbr\u003e\u003cbr\u003e The DRSL-SP2 can be used for signal conversion of standard process voltage or current signals into two individual analog signals. The unit offers 4-port isolation, provides surge suppression and protects control systems from transients and noise. The DRSL-SP2 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. When the input is configured for 2-wire transmitter mode, the DRSL-SP2 provides the current loop supply voltage. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 20.5 mA\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 23 mA\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eInput Voltage Drop:\u003c\/b\u003e \u0026lt;1.5V\u003cbr\u003e \u003cb\u003e2-Wire Transmitter Supply:\u003c\/b\u003e \u0026gt;17V\/20 mA\u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 10.25V\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 11.5V\/ 0 to 5.75V\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e ≥500 kΩ\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNo. of Outputs:\u003c\/b\u003e 2\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 20.5 mA (span)\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 23 mA\/300 Ω max\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/100 Ω\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ≤28 mA\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 10V\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 10, 2 to 10, 0 to 5 and 1 to 5V\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e \u0026gt;10 kΩ min\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage (via Power Rail or Connectors):\u003c\/b\u003e 16.8 to 31.2 Vdc\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 1.2 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.4 W typical\/0.65 W max\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input\/output 1\/output 2\/ supply\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;7 ms\u003cbr\u003e \u003cb\u003eSpan:\u003c\/b\u003e Corresponds to the presently selected DIP switch output range\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e \u0026lt;±0.05 % of span\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt;±0.01% of span\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm2\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818409173287,"sku":"DRSL-SP2-Rptr-Spltr","price":604.95,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818409206055,"sku":"DRSL-SP2-Rptr-Spltr","price":604.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-sp2_l_ywycl5l1p3sb7vse.jpg?v=1741345576"},{"product_id":"din-rail-temperature-voltage-current-signal-conditioners","title":"DIN Rail Temperature, Voltage\/Current Signal Conditioners","description":"\u003cp\u003eThese DIN rail-mounted signal conditioners are designed to convert temperature, voltage, and current signals to standardized outputs, facilitating integration with control systems and instrumentation. They offer high accuracy and reliability, ensuring consistent performance in industrial environments. The compact DIN rail design allows for easy installation and space-saving in control panels.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eConverts temperature, voltage, and current signals to standardized outputs\u003c\/p\u003e\n\n\u003cp\u003eHigh accuracy and reliability for consistent performance\u003c\/p\u003e\n\n\u003cp\u003eDIN rail-mounted design for easy installation\u003c\/p\u003e\n\n\u003cp\u003eCompact size for space-saving in control panels\u003c\/p\u003e\n\n\u003cp\u003eSuitable for integration with control systems and instrumentation\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818409861415,"sku":"DRC-8900-Series-Sig-Cond","price":718.74,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818409894183,"sku":"DRC-8900-Series-Sig-Cond","price":718.74,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drc-8900_l_ktr96k5elvacfboe.jpg?v=1741345599"},{"product_id":"din-rail-signal-conditioner-for-load-cells","title":"DIN RAIL Signal Conditioner for Load Cells","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\n\u003cp class=\"contentTitle\"\u003e \u003c\/p\u003e \u003cspan class=\"descCopyPP\"\u003e Brand New DRST-BG MV Signal Transmitter converts bipolar mV signals from transducers supplied directly by the device to standard current\/voltage signals.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eApplication\u003c\/b\u003e\u003cbr\u003e DRST-BG is suitable for load cell application as well as other applications such as tank filling and draining, weighing with a taring function, measurement of cable tensile force, level control, signal conversion\/amplification.\u003cbr\u003e \u003cb\u003eAdvanced Features\u003c\/b\u003e\u003cbr\u003e A multifunction user interface consisting of three push buttons and a 3-digit LED display for programming.\u003cbr\u003e \u003cb\u003eTechnical Characteristics\u003c\/b\u003e\u003cbr\u003e     • Front error LED.\u003cbr\u003e     • The analog input can be programmed for voltage in the range -40 to 100 m Vdc.\u003cbr\u003e     • The digital signal can be selected as either NPN or PNP. Taring can either be by way of the digital input or from the front interface.\u003cbr\u003e     • The analog output can be programmed to current in the range 0 to 20 mA or voltage in the range     • Short circuit protected transducer supply which can be programmed to 5 to 13 Vdc from the front.\u003cbr\u003e     • Sense input (with transducer supply used) for compensation for cable resistance to the transducer.\u003cbr\u003e     • Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e \u003cb\u003eEnvironmental Conditions\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -20 to 60°C\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e \u0026lt; 95% RH (non-cond.)\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP50\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMechanical Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions (HxWxD):\u003c\/b\u003e 80.5 x 35.5 x 84.5 mm (D is without pins)\u003cbr\u003e \u003cb\u003eWeight Approx:\u003c\/b\u003e 130 g\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCommon Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 19.2 to 28.8 Vdc\u003cbr\u003e \u003cb\u003eMax. Required Power:\u003c\/b\u003e 7.2 W\u003cbr\u003e \u003cb\u003eInternal Power Dissipation:\u003c\/b\u003e 2.2 W\u003cbr\u003e \u003cb\u003eResponse Time (Programmable):\u003c\/b\u003e 0.06 to 999 s\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e Min. 60 dB\u003cbr\u003e \u003cb\u003eUpdating Time:\u003c\/b\u003e 20 ms\u003cbr\u003e \u003cb\u003eSignal Dynamics, Input:\u003c\/b\u003e 17 bit\u003cbr\u003e \u003cb\u003eSignal Dynamics, Output:\u003c\/b\u003e 16 bit\u003cbr\u003e \u003cb\u003eEffect of Supply Voltage Change:\u003c\/b\u003e \u0026lt; ±0.002% of span\/%V\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt; ±0.01% of span\/°C\u003cbr\u003e \u003cb\u003eLinearity Error:\u003c\/b\u003e \u0026lt; 0.1% of span\u003cbr\u003e \u003cb\u003eAuxiliary Voltage:\u003c\/b\u003e Transducer\u003cbr\u003e \u003cb\u003eSupply:\u003c\/b\u003e 5 to 13 Vdc\u003cbr\u003e \u003cb\u003eLoad (Max.):\u003c\/b\u003e 230 mA\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt; ±0.5% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eInput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCommon Input Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMax. Offset:\u003c\/b\u003e 70% of selec. max. value\u003cbr\u003e \u003cb\u003eVoltage input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e -40 to 100 mV\u003cbr\u003e \u003cb\u003eMin. Measurement Range (Span):\u003c\/b\u003e 10 mV\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e \u0026gt; 10 MO\u003cbr\u003e \u003cb\u003eOverrange:\u003c\/b\u003e 0 to 999% of selected measurement range\u003cbr\u003e \u003cb\u003eNPN, Digital Input:\u003c\/b\u003e Pull up 24 Vdc \/ 6.9 mA\u003cbr\u003e \u003cb\u003ePNP, Digital Input:\u003c\/b\u003e Pull down 0 Vdc\/6.9 mA\u003cbr\u003e \u003cb\u003eTrig Level Low, NPN\/PNP:\u003c\/b\u003e \u0026lt; 6 Vdc\u003cbr\u003e \u003cb\u003eTrig Level High, NPN\/PNP:\u003c\/b\u003e \u0026gt; 10.5 Vdc\u003cbr\u003e \u003cb\u003ePulse Length:\u003c\/b\u003e \u0026gt; 30 ms\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOutput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 20 mA\u003cbr\u003e \u003cb\u003eMin. Signal Range:\u003c\/b\u003e 5 mA\u003cbr\u003e \u003cb\u003eLoad (@ Current Output):\u003c\/b\u003e = 600 Ω\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e= 0.01% of span\/100 Ω\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e \u0026lt; 23 mA\u003cbr\u003e \u003cb\u003eVoltage Output Through Internal\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eshunt:\u003c\/b\u003e See manual for details\u003cbr\u003e \u003cb\u003eOf Span:\u003c\/b\u003e = of the presently selected range\u003cbr\u003e\u003cbr\u003e \u003cb\u003eObserved Authority Requirements\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEMC\u003c\/b\u003e 2014\/30\/EU\u003cbr\u003e \u003cb\u003eEAC:\u003c\/b\u003e TR-CU 020\/2011 \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818411172135,"sku":"DRST-BG-Load-Cell-Cond","price":1195.5,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818411204903,"sku":"DRST-BG-Load-Cell-Cond","price":1195.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drst-bg_l_81n0ksoe8vgin4kf.jpg?v=1741345619"},{"product_id":"din-rail-ac-voltage-current-conditioners-with-self-power","title":"DIN Rail AC Voltage\/Current Conditioners with Self Power","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   The DRA-ACT-SI AND DRA- ACT-SV Series are self-powered ac current and ac voltage input DIN rail mount signal conditioners that use the measured input to produce an accurate and linear output current. These signal conditioners have excellent accuracy, linearity and stability which make them unique. The DRA-ACT-SI Series of ac current input models includes models for 0-1 Aac and 0-5 Aac inputs with a choice of either 0-1 mA or 0-20 mA output. The DRA-ACT-SV Series of ac voltage input models includes models for 0-150 Vac and 0-300 Vac inputs again with a choice of either 0-1 mA or 0-20 mA output. The output current from all of these self-powered models always starts at 0 mA since these units are powered from the measured signal. Therefore, when the ac current or voltage input is zero, the output is zero. For complete safety, an internal transformer isolates the signal conditioner input from the output thus enabling these units to withstand large momentary inputs. The input to output isolation provides high output signal-to-noise ratio which makes these signal conditioners highly immune to ground loop signals and RFI.  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818412646695,"sku":"DRA-ACT-S-Series-Sig-Cond","price":369.73,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818412679463,"sku":"DRA-ACT-S-Series-Sig-Cond","price":369.73,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dra-act-s_l_1xrpvfbscvzlvlih.jpg?v=1741345643"},{"product_id":"snap-in-front-panel-programmer-with-modbus-over-rs-485","title":"Snap In Front Panel Programmer with Modbus over RS-485","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cb\u003eApplication\u003c\/b\u003e \u003cp\u003eThe DRST-CM detachable display adds Modbus RTU RS-485 serial communications to DRST-AC, DRST-DC, DRST-UN, and DRST-UR units.  The unit converts a wide array of sensors and analog device signals like uni- and bipolar mA and voltage signals, potentiometer, Lin. R, RTD and TC, to a Modbus communication line signal. All individual unit operating parameters can easily and quickly be configured by using the Modbus communication or by using the front display menu.  The easily readable DRST-CM display can be used to read the process signal, simulate the output signal, indicate sensor errors and internal device errors.\u003c\/p\u003e\n\u003cbr\u003e \u003cb\u003eTechnical characteristics\u003c\/b\u003e \u003cp\u003eDRST-CM has full DRSL-DISPLAY functionality for unit programming, process signal monitoring and diagnostics handling.  Modbus RTU protocol is supported using a serial RS-485 communication wiring.  Multidrop half-duplex connection via shielded RJ45 connector.  High safe galvanic isolation of 2.5 kVAC between the serial wiring and the connected DRST-AC, DRST-DC, DRST-UN, and DRST-UR units. Modbus parameters such as address, baud rate, stop bit(s), and parity bit are configured from the DRST-CM display, which also stores parameters.\u003c\/p\u003e\n\u003cbr\u003e \u003cb\u003eMounting \/ installation \/ programming\u003c\/b\u003e \u003cp\u003eThe DRST-CM can be moved from one device to another. The individual DRST-AC, DRST-DC, DRST-UN, and DRST-UR unit configuration of the first device can be saved and downloaded to subsequent devices. Programmed parameters can be protected by a userdefined password.  When mounted on devices that are installed upside down, a menu item allows the display on the 4511 to be rotated 180 degrees and the up\/down buttons to switch function.\u003c\/p\u003e\n\u003cbr\u003e \u003cb\u003eEnvironmental Conditions\u003c\/b\u003e\u003cbr\u003e Operating temperature................................... -20°C to +60°C\u003cbr\u003e Storage temperature...................................... -20°C to +85°C\u003cbr\u003e Relative humidity............................................ \u0026lt; 95% RH (non-cond.)\u003cbr\u003e Protection degree........................................... IP20\u003cbr\u003e Installation in.................................................. Pollution degree 2 \u0026amp; meas. \/overvoltage cat. II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMechanical specifications\u003c\/b\u003e\u003cbr\u003e Dimensions (HxWxD)..................................... 73.2 x 23.3 x 26.5 mm\u003cbr\u003e Dimensions (HxWxD) w\/\u003cbr\u003eDRST-AC, DRST-DC, DRST-UN, DRST-UR \u003cbr\u003eunit................................................................ 109 x 23.5 x 131 mm\u003cbr\u003e Weight approx................................................ 30 g\u003cbr\u003e Connection..................................................... RJ45 - shielded\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCommon specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply\u003c\/b\u003e\u003cbr\u003e Max. required power...................................... ≤ 0.15 W\u003cbr\u003e\u003cbr\u003e \u003cb\u003eIsolation voltage\u003c\/b\u003e\u003cbr\u003e Isolation voltage, test\/working..................... 2.5 kVAC \/ 250 VAC reinforced isolation \u003cbr\u003e\u003cbr\u003e \u003cb\u003eResponse time\u003c\/b\u003e\u003cbr\u003e Response time............................................... \u0026lt; 20 ms\u003cbr\u003e Signal \/ noise ratio......................................... \u0026gt; 60 dB\u003cbr\u003e Update rate.................................................... \u0026gt; 50 Hz\u003cbr\u003e Extended EMC immunity: NAMUR\u003cbr\u003e NE21, A criterion, burst.................................. No loss of communication\u003cbr\u003e Signal type..................................................... RS-485 half duplex\u003cbr\u003e Serial protocol................................................ Modbus RTU\u003cbr\u003e Modbus mode................................................ RTU - slave\u003cbr\u003e Devices on an RS485 line.............................. Up to 32 (w\/o a repeater)\u003cbr\u003e Data rates, baud............................................ 2400, 4800, 9600, 19200,38400, 57600, 115200\u003cbr\u003e Automatic baudrate detection........................ Yes - can be configured ON or OFF\u003cbr\u003e Parity.............................................................. Even, Odd, None\u003cbr\u003e Stop bit(s)....................................................... 1 or 2\u003cbr\u003e Digital addressing.......................................... 1...247\u003cbr\u003e Response delay............................................. 0...1000 ms\u003cbr\u003e\u003cbr\u003e \u003cb\u003eObserved authority requirements\u003c\/b\u003e\u003cbr\u003e EMC............................................................... 2014\/30\/EU\u003cbr\u003e LVD................................................................ 2014\/35\/EU\u003cbr\u003e EAC................................................................ TR-CU 020\/2011\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818413859111,"sku":"DRST-CM-Programmer","price":407.15,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818413891879,"sku":"DRST-CM-Programmer","price":407.15,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drst-cm_l_l27dv8qpkij9vzuq.jpg?v=1741345663"},{"product_id":"din-rail-loop-powered-rtd-input-signal-conditioner","title":"DIN Rail Loop Powered RTD Input Signal Conditioner","description":"\u003cp\u003eThe DIN-Rail Loop-Powered RTD Input Signal Conditioner is designed for converting and conditioning RTD signals for industrial control systems. It provides reliable linearization and isolation of RTD inputs, ensuring accurate temperature readings in process automation applications. Powered directly from the loop, it eliminates the need for an external power source, reducing wiring complexity. Its compact DIN-rail design allows for easy integration into control panels, offering high stability and interference-free operation in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cp\u003eLoop-powered design eliminates the need for external power\u003c\/p\u003e\n\n\u003cp\u003eAccurate RTD signal linearization and conditioning\u003c\/p\u003e\n\n\u003cp\u003eCompact DIN-rail mount for easy installation\u003c\/p\u003e\n\n\u003cp\u003eProvides isolation to prevent signal interference\u003c\/p\u003e\n\n\u003cp\u003eSuitable for industrial process control and automation\u003c\/p\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818415235367,"sku":"DRA-RTT-2-Sig-Cond","price":339.24,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818415268135,"sku":"DRA-RTT-2-Sig-Cond","price":339.24,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dra-rtt-2_l_02g7puscpqxcd7xx.jpg?v=1741345686"},{"product_id":"din-rail-transmitter-with-rfid-communications","title":"DIN Rail Transmitter with RFID Communications","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The TXDIN401 and TXDIN402 DIN rail mount transmitters transform a temperature or process signal into a linearized 2-wire loop-powered 4 to 20 mA output. Model TXDIN401 is a temperature transmitter that accepts Pt100 or Ni100 RTD and Types J\/K\/T\/E\/R\/S\/B\/N thermocouples. Model TXDIN402 is a process input transmitter that accepts voltage, current or resistance input. The characteristics of these converters ensure high precision on the reading scale with 16-bit conversion. The 4 to 20 mA output can be scaled based on the desired input range.\u003cbr\u003e\u003cbr\u003e The programming procedure uses an RFID (NFC) mode with the dedicated TX400-RFID programmer that allows the user to make all calibrations and settings quickly and without the need to power and connect up the transmitter. Simply connect the TX400-RFID programmer to the USB port of your PC, start the RF Programmer configuration software and place the transmitter on top of the TX400-RFID programmer to establish communications. These transmitters are also provided with a data logging function for the input signal. Transmitters have a non-volatile memory (circular buffer) for data-logging with user-selectable sampling time. The user selects the sampling time (1 to 3600 seconds) and then each time the 4 to 20 mA loop powers the device, the input value is stored to non-volatile memory.\u003cbr\u003e\u003cbr\u003e An additional programming tool is the Omega Brand Google App - \u003ca class=\"blLink\" href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.omega.direct_link\"\u003e \"Direct Link\" \u003c\/a\u003e relying on RFID\/NFC connectivity and allowing straightforward programming without wirings by Android devices.\u003cbr\u003e\u003cbr\u003e Using the TX400-RFID programmer along with the RF Programmer configuration software (software is a free download from OMEGA) the user can:\u003cbr\u003e \u003cb\u003e•\u003c\/b\u003e Completely configure the transmitter including scaling the 4 to 20 mA output to desired input range\u003cbr\u003e \u003cb\u003e•\u003c\/b\u003e Implement field calibration to compensate for gain and offset errors\u003cbr\u003e \u003cb\u003e•\u003c\/b\u003e Download logged data to PC for visualization and printing\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRTD Input Types and Ranges (TXDIN401 Only)\u003c\/b\u003e\u003cbr\u003e \u003cb\u003ePt100 (a = 0.00385):\u003c\/b\u003e 2, 3, or 4-wire connection, -200 to 600°C (-328 to 1112°F)\u003cbr\u003e \u003cb\u003eNi100 (a = 0.00618):\u003c\/b\u003e 2, 3, or 4-wire connection, -60 to 180°C (-76 to 356°F)\u003cbr\u003e \u003cb\u003eThermocouple Input Types (TXDIN401 Only):\u003c\/b\u003e J\/K\/T\/E\/R\/S\/B\/N\/mV\u003cbr\u003e \u003cb\u003eProcess Input Types and Ranges (TXDIN402 Only):\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eVoltage:\u003c\/b\u003e 0 to 10 V\u003cbr\u003e \u003cb\u003eCurrent:\u003c\/b\u003e 0 to 20 mA (4 to 20 mA default)\u003cbr\u003e \u003cb\u003eResistance:\u003c\/b\u003e 0 to 4000 Ω\u003cbr\u003e \u003cb\u003eOutput Resolution:\u003c\/b\u003e 2 µA\u003cbr\u003e \u003cb\u003eOver-Range Output:\u003c\/b\u003e fs + 5°C\u003cbr\u003e \u003cb\u003eUnder-Range Output:\u003c\/b\u003e fs - 5°C\u003cbr\u003e \u003cb\u003eOutput Error (Failure):\u003c\/b\u003e Selectable between 21 mA or 3.8 mA\u003cbr\u003e \u003cb\u003eCurrent Output Protection:\u003c\/b\u003e 30 mA approx\u003cbr\u003e \u003cb\u003eRejection:\u003c\/b\u003e 50 to 60 Hz\u003cbr\u003e \u003cb\u003eMaximum Transmission Error:\u003c\/b\u003e 0.1% FS or 0.2°C whichever is greater\u003cbr\u003e \u003cb\u003eSampling Time:\u003c\/b\u003e 300 msec\u003cbr\u003e \u003cb\u003eResponse Time (10 to 90%):\u003c\/b\u003e 600 msec\u003cbr\u003e \u003cb\u003eNon-Volatile Memory (Circular Buffer) for Data Logging:\u003c\/b\u003e 2624 word\u003cbr\u003e \u003cb\u003eCable Resistance:\u003c\/b\u003e 20 Ω max\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt; 100 ppm\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 2-wire loop powered; operating range 6 to 32 Vdc\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Galvanic, 1 KVac input\/output\u003cbr\u003e \u003cb\u003eOperating Environment:\u003c\/b\u003e -40 to 85°C (-40 to 185°F), 30 to 90% RH (non condensing)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eMounting:\u003c\/b\u003e 3 mm DIN rail\u003cbr\u003e \u003cb\u003eMaterial:\u003c\/b\u003e Enclosure, polycarbonate; front panel, silicone\u003cbr\u003e \u003cb\u003eEnclosure Rating:\u003c\/b\u003e NEMA 1 (IP20) according to CE, EN 61000-6-4, EN 61000-6-2\u003cbr\u003e \u003cb\u003eProgramming:\u003c\/b\u003e Wireless with RFID technology (NFC)\u003cbr\u003e \u003cb\u003eSoftware:\u003c\/b\u003e Windows® XP\/7\/8 (32-bit and 64-bit), Windows 10 (64-bit)\u003cbr\u003e \u003cb\u003eConnection:\u003c\/b\u003e Screw terminals\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 30 g (1.05 oz) approx\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 90 H x 18 W x 64 mm D (3.54 x 0.71 x 2.52\") \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818416873767,"sku":"TXDIN400-Series-Tx","price":334.22,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818416906535,"sku":"TXDIN400-Series-Tx","price":334.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/txdin400_l_w0p1q4ay1v5fo7dl.jpg?v=1741345710"},{"product_id":"din-rail-field-configurable-alarm-limit-modules","title":"DIN Rail Field Configurable Alarm Limit Modules","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRG-AR Series modules are a family of DIN rail mount limit alarms with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint capability. Modules are available for a variety of input types including thermocouples, RTDs, DC and AC current and voltages.\u003cbr\u003e\u003cbr\u003e Each module can be set to a number of input ranges via an input selector switch. The alarm points and dead band are adjusted by potentiometers.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDiagnostic LEDs\u003c\/b\u003e\u003cbr\u003e All modules are equipped with 3 front panel LEDs. The first is a dual function LED labeled input. This green LED indicates line power and input signal status. Two red LEDs indicate the relay state for each setpoint. An illuminated red LED indicates the tripped condition.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOutput\u003c\/b\u003e\u003cbr\u003e The DRG-AR Series modules are equipped with two SPDT relays, rated at 120 Vac or 28 Vdc at 5 amperes. Each of these relays is independently controlled by the field configurable setpoint and deadband.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOperation\u003c\/b\u003e\u003cbr\u003e The field configurable limit alarm setpoints can be configured for HI or LO, failsafe or non-failsafe operation. Each of the setpoints has a respective HI or LO deadband. In a tripped condition, the setpoint is exceeded and the appropriate red LED will illuminate. The trip will reset only when the process falls below the HI deadband or rises above the low deadband. In failsafe operation, the relay is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non-fail-safe). In the fail-safe mode, a power failure results in an alarm state output.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDynamic DeadBand\u003c\/b\u003e\u003cbr\u003e LSI circuitry in the DRG-AR Series prevents false trips by repeatedly sampling the input. The input must remain beyond the setpoint for 100 milliseconds to qualify as a valid trip condition. Likewise, the input must fall outside the deadband and remain there for 100 milliseconds to return the alarm to an untripped condition. This, effectively, results in a dynamic deadband.\u003cbr\u003e\u003cbr\u003e \u003cimg border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/DRG-AR.png?v=1741345720\"\u003e\u003cbr\u003e\u003cbr\u003e \u003cb\u003e\u003cu\u003e\u003cfont color=\"#4781c3\"\u003eDRG-AR-AC AC Voltage or Current Input Limit Alarm\u003c\/font\u003e\u003c\/u\u003e\u003c\/b\u003e\u003cbr\u003e The DRG-AR-AC is a DIN rail mount, AC voltage or AC current input limit alarm with dual setpoints and two contact closure outputs. Input voltage spans from 100 mVac to 200 Vac and input current spans from 10 mAAC to 100 mAAC can be field configured. For current spans of 1 to 5 Amps a 0.1. (5 W) shunt resistor (Model# DRG-C006) is available.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Ranges\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eVoltage:\u003c\/b\u003e 100 mVAC, 200 mVac, 500 mVac, 1 Vac, 2 Vac, 5 Vac, 10 Vac, 20 Vac, 50 Vac, 100 Vac, 200 Vac\u003cbr\u003e \u003cb\u003eCurrent:\u003c\/b\u003e 10 mAAC, 20 mAAC, 50 mAAC, 100 mAAC\u003cbr\u003e\u003cbr\u003e \u003cb\u003e\u003cu\u003e\u003cfont color=\"#4781c3\"\u003eDRG-AR-RTD Input Limit Alarm\u003c\/font\u003e\u003c\/u\u003e\u003c\/b\u003e\u003cbr\u003e The DRG-AR-RTD is a DIN rail mount, RTD input limit alarm with dual setpoints and two contact closure outputs. The module features up to 8 temperature ranges for each RTD type.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eInput Ranges\u003c\/b\u003e\u003cbr\u003e \u003ctable border=\"1\" bordercolor=\"black\" cellpadding=\"2\" cellspacing=\"0\" width=\"660\"\u003e \u003ctr bgcolor=\"#7cd0e0\"\u003e\n\u003ctd\u003e \u003cfont color=\"white\"\u003e\u003cb\u003eRTD Type\u003c\/b\u003e\u003c\/font\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003cfont color=\"white\"\u003e\u003cb\u003eTemperature Ranges (°C)\u003c\/b\u003e\u003c\/font\u003e \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e Pt100, 500, 1000 \u003c\/td\u003e\n\u003ctd\u003e 0 to 50, -50 to 50, 0 to 100, -100 to 100, (a = 0.00385), 0 to 250, -200 to 250, 0 to 550, 0 to 850 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e Cu10 \u003c\/td\u003e\n\u003ctd\u003e 25 to 70, -30 to 70, 25 to 120, -70 to 120, 25 to 260, -200 to 260 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e Cu100 \u003c\/td\u003e\n\u003ctd\u003e 25 to 75, -25 to 75, 25 to 150, -100 to 150, 25 to 260, -200 to 260 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e Ni120 \u003c\/td\u003e\n\u003ctd\u003e -30 to 30, -80 to 30, -30 to 100, -30 to 200, -30 to 320 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e NiFe604 \u003c\/td\u003e\n\u003ctd\u003e -40 to 0, -40 to 50, -200 to 50, -200 to 100, -200 to 240 \u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e \u003cb\u003e\u003cu\u003e\u003cfont color=\"#4781c3\"\u003eDRG-AR-TC Thermocouple Input Limit Alarm\u003c\/font\u003e\u003c\/u\u003e\u003c\/b\u003e\u003cbr\u003e The DRG-AR-TC is a DIN rail mount, thermocouple input limit alarm with dual setpoints and two contact closure outputs. The module features up to six temperature ranges for each thermocouple type to ensure accuracy and maximize setpoint resolution. A bipolar switch is provided for temperature ranges below 0°C. The DRG-AR-TC is configurable as a single or dual setpoint alarm, with HI or LO trips, upscale or downscale burnout detection and failsafe or non-failsafe operation.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eInput Ranges\u003c\/b\u003e\u003cbr\u003e \u003ctable border=\"1\" bordercolor=\"black\" cellpadding=\"2\" cellspacing=\"0\" width=\"660\"\u003e \u003ctr bgcolor=\"#7cd0e0\"\u003e\n\u003ctd\u003e \u003cfont color=\"white\"\u003e\u003cb\u003eT\/C\u003c\/b\u003e\u003c\/font\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003cfont color=\"white\"\u003e\u003cb\u003eTemperature Ranges (°C)\u003c\/b\u003e\u003c\/font\u003e \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e B \u003c\/td\u003e\n\u003ctd\u003e 0 to1490, 0 to 1820 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e E \u003c\/td\u003e\n\u003ctd\u003e 0 to 150, 0 to 290, 0 to 660, 0 to 1000, -270 to 150, -270 to 290 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e J \u003c\/td\u003e\n\u003ctd\u003e 0 to 190, 0 to 350, 0 to 760, -210 to 190, -210 to 350 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e K \u003c\/td\u003e\n\u003ctd\u003e 0 to 250, 0 to 480, 0 to 1280, 0 to 1372, -270 to 250, -270 to 480 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e R \u003c\/td\u003e\n\u003ctd\u003e 0 to 970, 0 to 1690, 0 to 1760 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e S \u003c\/td\u003e\n\u003ctd\u003e 0 to 1050, 0 to 1750 \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e T \u003c\/td\u003e\n\u003ctd\u003e 0 to 210, 0 to 390, -270 to 210, -270 to 390 \u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e \u003cb\u003e\u003cu\u003e\u003cfont color=\"#4781c3\"\u003eDRG-AR-DC DC Voltage and Current Input Limit Alarm\u003c\/font\u003e\u003c\/u\u003e\u003c\/b\u003e\u003cbr\u003e The DRG-AR-DC is a DIN rail mount, DC voltage and DC current input limit alarm with dual setpoints and two contact closure outputs. Input voltage spans from 10 mV to 200 V and input current spans from 1 mA to 100 mA can be field configured. Bipolar inputs are also accepted. The module also features 24 Vdc voltage source (isolated from line power) for transducer excitation.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Ranges (Unipolar \u0026amp; Bipolar)\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eVoltage:\u003c\/b\u003e 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V,2 V, 5 V, 10 V, 20 V, 50 V, 100 V, 200 V\u003cbr\u003e \u003cb\u003eCurrent:\u003c\/b\u003e 1 mA, 2 mA, 5 mA, 10 mA, 20 mA, 50 mA, 100 mA\u003cbr\u003e\u003cbr\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818418905383,"sku":"DRG-AR-Series-Sig-Cond","price":974.13,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818418938151,"sku":"DRG-AR-Series-Sig-Cond","price":974.13,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drg-ar_l_wfou6l0ak6jgm1ih.jpg?v=1741345738"},{"product_id":"din-rail-isolated-repeater-splitter-for-current-signals","title":"DIN Rail Isolated Repeater\/Splitter for Current Signals","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-SP1 isolated repeater\/ splitter provides a competitive choice in terms of both price and technology for galvanic isolation of current signals to SCADA systems or PLC equipment. Two current outputs are provided which mirror the single current input.\u003cbr\u003e\u003cbr\u003e The DRSL-SP1 can be used for signal conversion of a standard process current signal into two individual analog signals. The unit offers 4-port isolation, provides surge suppression and protects control systems from transients and noise. The DRSL-SP1 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCURRENT INPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 20.5 mA\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 23 mA\u003cbr\u003e \u003cb\u003eInput Voltage Drop:\u003c\/b\u003e \u0026lt;1.5 Vdc \u003cbr\u003e\u003cbr\u003e \u003cb\u003eCURRENT OUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNumber of Outputs:\u003c\/b\u003e 2\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 20.5 mA (span)\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 23 mA\/300 Ω maximum\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/100 Ω (span = 0 to 20 mA)\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ≤28 mA\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage (via Power Rail or Connectors):\u003c\/b\u003e 16.8 to 31.2 Vdc\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 0.8 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.4 W typical\/0.65 W max\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input\/output 1\/ output 2\/supply\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt; 60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;7 ms\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e \u0026lt; ±0.05% of span\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt;±0.01% of span\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt; ±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity\u003cbr\u003e NAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm2\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818420543783,"sku":"DRSL-SP1-Rptr-Spltr","price":532.0,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818420576551,"sku":"DRSL-SP1-Rptr-Spltr","price":532.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-sp1_l_crdvj3kwjawg63hm.jpg?v=1741345760"},{"product_id":"din-rail-ac-powered-dc-input-signal-splitter","title":"DIN Rail AC Powered DC Input Signal Splitter","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e AC powered, DIN rail mount, DC input signal splitter, with 1800 Vdc isolation between input, output and power. The DRI-SP-AC Series provides two fully isolated DC output signals in proportion to one DC input. The field configurable input and output feature offers flexible, wide ranging capability for DC current and voltage signals.\u003cbr\u003e\u003cbr\u003e Using a pushbutton instead of potentiometers, improvements in calibration resolution and reliability are realized due to the elimination of the potentiometers’ mechanical variability. The thermal drift and mechanical variability of the potentiometers has been removed and replaced with a digitally stable circuit. Additionally, the inherent zero and span interactivity of analog amplifier circuitry is removed, providing 100% non-interactive adjustment.\u003cbr\u003e\u003cbr\u003e The DRI-SP-AC can be field configured for virtually any DC input to DC output within the limits specified. Calibration utilizes touch calibration technology where the user simply configures the input for the current or voltage range via switches, then follows the calibration procedure. The output is set by adjusting the input until the desired output is present and then pressing the CAL button to store the output level.\u003cbr\u003e\u003cbr\u003e The DRI-SP-AC has three diagnostic LEDs. The green (RUN) LED is used for diagnostics to indicate that power is on. It will flash quickly if the input signal is above the calibrated range or slowly if the input signal is below range. It is on continuously when the unit is functioning within the calibrated range.\u003cbr\u003e\u003cbr\u003e The DRI-SP-AC can be configured for input ranges from 10 mV to 100V or 1 mA to 100 mA, with \u0026gt;90% input offset or will adjust down to \u0026lt;10% of full scale input span (except on 20 mV\/2 mA range where maximum offset or gain adjustment is 50%).\u003cbr\u003e\u003cbr\u003e \u003cb\u003eThe factory default configuration for the DRI-SP-AC is:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Range:\u003c\/b\u003e 20 mA (current on)\u003cbr\u003e \u003cb\u003eInput Configuration:\u003c\/b\u003e Unipolar\u003cbr\u003e \u003cb\u003eCalibrated Input:\u003c\/b\u003e 4 to 20 mA\u003cbr\u003e \u003cb\u003eOperation:\u003c\/b\u003e Direct (reverse off)\u003cbr\u003e \u003cb\u003eCalibrated Output:\u003c\/b\u003e 4 to 20 mA\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e INPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eVoltage Input:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1V, 2V, 5V, 10V, 25V, 50V, 100V (dip-switch selectable)\u003cbr\u003e \u003cb\u003eImpedance:\u003c\/b\u003e ≥100 kΩ\u003cbr\u003e \u003cb\u003eOvervoltage:\u003c\/b\u003e 200V continuous\u003cbr\u003e \u003cb\u003eCurrent Input:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 2 mA, 5 mA, 10 mA, 20 mA, 50 mA, 100 mA (dip-switch selectable)\u003cbr\u003e \u003cb\u003eImpedance:\u003c\/b\u003e 20 Ω typical\u003cbr\u003e \u003cb\u003eOvercurrent:\u003c\/b\u003e 170 mA, protected by self resetting fuse\u003cbr\u003e \u003cb\u003eOvervoltage:\u003c\/b\u003e 60V\u003cbr\u003e \u003cb\u003ePushbutton Adjustment (Inputs \u0026gt;10 mV):\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEffective Zero Offset:\u003c\/b\u003e ≥90%\u003cbr\u003e \u003cb\u003eEffective Span Turn Down:\u003c\/b\u003e ≥90% except 20 mV\/2 mA range in which 50% is max zero offset and span turndown\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUTS (2 Channels)\u003cbr\u003e Voltage Output:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 0 to 5V, 0 to 10V (dip-switch selectable)\u003cbr\u003e \u003cb\u003eSource Impedance:\u003c\/b\u003e \u0026lt;10 Ω\u003cbr\u003e \u003cb\u003eDrive:\u003c\/b\u003e 10 mA max\u003cbr\u003e \u003cb\u003eCurrent Output:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 4 to 20 mA, 0 to 1 mA (dip-switch selectable)\u003cbr\u003e \u003cb\u003eSource Impedance:\u003c\/b\u003e \u0026gt;100 kΩ\u003cbr\u003e \u003cb\u003eCompliance:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003e0 to 1 mA:\u003c\/b\u003e 7.5V max (7.5 kΩ)\u003cbr\u003e \u003cb\u003e4 to 20 mA:\u003c\/b\u003e 10V max (500 Ω)\u003cbr\u003e \u003cb\u003eOutput Ripple:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003e\u0026lt;50% Offset or Span Adjust:\u003c\/b\u003e \u0026lt;0.1% of full scale span or 25 mV RMS, whichever is greater\u003cbr\u003e \u003cb\u003e\u0026gt;50% Offset or Span Adjust:\u003c\/b\u003e \u0026lt;0.2% of full scale span or 50 mV RMS, whichever is greater\u003cbr\u003e \u003cb\u003eOutput Accuracy:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003e\u0026gt;2 mA\/\u0026gt;20 mV Input Spans:\u003c\/b\u003e ±0.1% of full-scale input typical, ±0.2% maximum\u003cbr\u003e \u003cb\u003e\u0026lt;2 mA\/\u0026lt;20 mV Input Spans:\u003c\/b\u003e ±0.35% of full scale input typical, ± 0.5% maximum including linearity, repeatability and hysteresis @ 23°C\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e 200 msec, typical\u003cbr\u003e \u003cb\u003eStability:\u003c\/b\u003e ±0.025% of full scale\/°C, maximum for full scale and zero\u003cbr\u003e \u003cb\u003eCommon Mode Rejection:\u003c\/b\u003e 120 dB at DC, \u0026gt;90 dB at 60 Hz\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e ≥1800 Vdc or peak AC between input, output, power and channel-to-channel\u003cbr\u003e \u003cb\u003eESD Susceptibility:\u003c\/b\u003e Capable of meeting IEC 801-2 level 3(8 kV)\u003cbr\u003e \u003cb\u003eHumidity (Non-Condensing):\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating:\u003c\/b\u003e 15 to 95 %RH @ 45°C (113°F)\u003cbr\u003e \u003cb\u003eSoak:\u003c\/b\u003e 90% RH for 24 hours @ 60°C (140°F)\u003cbr\u003e \u003cb\u003eTemperature:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating:\u003c\/b\u003e 0 to 55°C (32 to 131°F)\u003cbr\u003e \u003cb\u003eStorage:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e 100 to 240 Vac, ±10%, 50 to 400 Hz; 2.5 W max\u003cbr\u003e \u003cb\u003eWire Terminals:\u003c\/b\u003e Socketed screw terminals for 12 to 22 AWG\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 227 g (0.5 lb) \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818427687207,"sku":"DRI-SP-AC-Signal-Splitter","price":1161.22,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818427719975,"sku":"DRI-SP-AC-Signal-Splitter","price":1161.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dri-sp-ac_l_afckkvzjfdl8jcks.jpg?v=1741345783"},{"product_id":"din-rail-signal-conditioner-series-with-process-input","title":"DIN Rail Signal Conditioner Series with Process Input","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-DC3 isolated DIN rail signal conditioner provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. The DRSL-DC3 can be used for signal conversion of standard process voltage or current signals. The unit offers isolation between input, output and supply, provides surge suppression and protects control systems from transients and noise.\u003cbr\u003e\u003cbr\u003e The DRSL-DC3 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 20.5 mA\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 23 mA\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eInput Voltage Drop:\u003c\/b\u003e \u0026lt; 1.5V \u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 10.25V\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 11.5V\/ 0 to 5.75V\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e ≥500 kΩ\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 20.5 mA (span)\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 23 mA\/600 Ω max\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/ 100 Ω\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ≤28 mA\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 10V\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 10, 2 to 10, 0 to 5 and 1 to 5V\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e \u0026gt;10 kΩ min\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage (via Power Rail or Connectors):\u003c\/b\u003e 16.8 to 31.2 Vdc\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 0.8 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.4 W typical\/ 0.65 W max\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input\/Output\/Supply\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eMTBF:\u003c\/b\u003e \u0026gt;249 years, according to IEC 61709 (SN29500)\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;7 ms\u003cbr\u003e \u003cb\u003eSpan:\u003c\/b\u003e Corresponds to the presently selected DIP switch output range\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e \u0026lt;±0.2% of span\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt;±0.015% of span\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5”)\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm2\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818429063463,"sku":"DRSL-DC3-Process-Sig-Cond","price":438.77,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818429096231,"sku":"DRSL-DC3-Process-Sig-Cond","price":438.77,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-dc3_l_hglv7dmckzaebhpf.jpg?v=1741345806"},{"product_id":"din-rail-isolated-repeater-splitter-for-bipolar-process-signals","title":"DIN Rail Isolated Repeater\/Splitter for Bipolar Process Signals","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-SP3 bipolar isolated signal conditioner\/splitter provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. Two process outputs are provided which mirror the single process input.\u003cbr\u003e\u003cbr\u003e The DRSL-SP3 can be used for signal conversion of standard bipolar analog process signals into two individual unipolar or bipolar analog signals. The unit offers 4-port isolation, provides surge suppression and protects control systems from transients and noise. The DRSL-SP3 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e ±10 mA, ±20 mA\u003cbr\u003e \u003cb\u003eFunctional Range,\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Input:\u003c\/b\u003e -23 to 23 mA\u003cbr\u003e \u003cb\u003eInput Voltage Drop:\u003c\/b\u003e \u0026lt;1V @ 23 mA\u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Ranges:\u003c\/b\u003e ±5V, ±10V\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e -11.5 to 11.5V\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e ≥1 MΩ\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNo. of Outputs:\u003c\/b\u003e 2\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA, 4 to 20 mA, ±10 mA, ±20 mA\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 23 mA\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 23 mA\/300 Ω max (per channel)\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.002% of span (presently selected range)\/100 Ω\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ≤28 mA\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 10V, 2 to 10V, 0 to 5V, 1 to 5V\u003cbr\u003e \u003cb\u003eFunctional Range:\u003c\/b\u003e 0 to 11.5V\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e \u0026gt;10 kΩ min\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage (via Power Rail or Connectors):\u003c\/b\u003e 16.8 to 31.2 Vdc\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 0.8 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.4 W typical\/0.65 W max\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input\/output 1\/ output 2\/supply\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eMTBF:\u003c\/b\u003e \u0026gt;187 years, according to IEC 61709 (SN29500)\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eCut-Off Frequency (3 dB):\u003c\/b\u003e \u0026gt;100 Hz or 10 Hz (selectable via DIP-switch)\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;7 ms or \u0026lt;44 ms\u003cbr\u003e \u003cb\u003eSpan:\u003c\/b\u003e Corresponds to the presently selected DIP switch output range\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e \u0026lt;±0.05% of span\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e \u0026lt;±0.01% of span\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/ AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818430538023,"sku":"DRSL-SP3-Rptr-Spltr-BP","price":658.85,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818430570791,"sku":"DRSL-SP3-Rptr-Spltr-BP","price":658.85,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-sp3_l_i9msfsuferukhraf.jpg?v=1741345831"},{"product_id":"dual-din-rail-temperature-transmitter-w-programmable-inputs","title":"Dual DIN Rail Temperature Transmitter w\/ Programmable Inputs","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e It provides 2 channels of configurable inputs, and supports multiple voltage, RTD, thermocouple inputs with auto reference junction compensation. If parallel connected to an external precise resistance, it accepts current signal input. Each channel has its own digital filtering and can adjust its filtering degree.\u003cul\u003e\n\u003cli\u003eIt generates two isolated current outputs, 4 to 20 or 0 to 20 mA. The range of retransmission output can be freely defined.\u003c\/li\u003e\n\u003cli\u003eThe model is DIN rail mounted. Its width is only 22.5 mm. The instrument can be easily configured by connecting to our E8 handset display.\u003c\/li\u003e\n\u003cli\u003eUniversal power supply of 100 to 240 Vac or 24 Vdc.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cb\u003eSPECIFICATIONS\u003c\/b\u003e \u003cbr\u003e\u003cb\u003eInput Type\u003c\/b\u003e \u003cbr\u003e\u003cb\u003eThermocouple:\u003c\/b\u003e K, J, T, E, R, S, B, N WRe5-WRe26 \u003cbr\u003e\u003cb\u003eRTD:\u003c\/b\u003e Pt100, Cu50 \u003cbr\u003e\u003cb\u003eLinear Voltage:\u003c\/b\u003e 0 to 20 mV, 0 to 60 mV, 0 to 100 mV, 0 to 1V, 0.2 to 1V \u003cbr\u003e\u003cb\u003eInstrument Input Range\u003c\/b\u003e K(-50 to 1300°C), S(-50 to 1700°C), R(-50 to 1700°C), T(-200 to 350°C), E(0 to 1000°C), J(0 to 1200°C), B(0 to 1800°C), N(-50 to 1300°C), WRe5%WRe26(0 to 2300°C), Pt100(-200 to 900°C) \u003cbr\u003e\u003cb\u003eLinear Input:\u003c\/b\u003e -9990 to 30,000 units defined by user \u003cbr\u003e\u003cb\u003eRetransmission Accuracy:\u003c\/b\u003e 0.3% FS ±1 digit (including input and output error) \u003cbr\u003e\u003cb\u003eOutput Specification:\u003c\/b\u003e Can be freely defined in the range of 0 to 22 mA with maximum output voltage ≥11V \u003cbr\u003e\u003cb\u003eTemperature Drift:\u003c\/b\u003e ≥0.015%FS\/°C (including the temperature drift of input and output) \u003cbr\u003e\u003cb\u003eElectromagnetic Compatibility (EMC):\u003c\/b\u003e ±4 KV\/5 KHz according to IEC61000-4-4 (EFT); 4 KV according to IEC61000-4-5 \u003cbr\u003e\u003cb\u003eIsolation Withstanding Voltage:\u003c\/b\u003e Voltage between power, signal input and output terminals ≥2300 Vdc; \u003cbr\u003e\u003cb\u003ePower Supply:\u003c\/b\u003e 100 to 240 Vac, -15%, +10% \/50 to 60 Hz; or 24VDC \u003cbr\u003e\u003cb\u003ePower Consumption:\u003c\/b\u003e ≥3W \u003cbr\u003e\u003cb\u003eOperating Ambient:\u003c\/b\u003e Temperature -10 to 60°C; humidity ≥90%RH \u003cbr\u003e\u003cfont size=\"1\"\u003eNote: B thermocouple obtains the above measurement accuracy only at the range of 400 to 1800°C. It's measurement from 60 to 400°C is less accurate.\u003c\/font\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818438172967,"sku":"TXDIN70-Series-Tx","price":409.63,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818438205735,"sku":"TXDIN70-Series-Tx","price":409.63,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/txdin70_l_p3oijf6imvn5tpok.jpg?v=1741345853"},{"product_id":"din-rail-bridge-input-conditioners-for-load-cell-or-strain-gage","title":"DIN Rail Bridge Input Conditioners for Load Cell or Strain Gage","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\n\u003cp class=\"contentTitle\"\u003eDescription\u003c\/p\u003e \u003cspan class=\"descCopyPP\"\u003e The DRC-4710 and DRC-4720 DIN rail mount signal conditioners are self-contained DC powered modules designed for bridge input (load cell, strain gage) or voltage input (not connected to a bridge, excitation supply not used). These signal conditioners contain a precision instrumentation amplifier, filtered output and a built-in 10V excitation supply capable of driving a 350 Ω bridge. \u003cbr\u003e\u003cbr\u003e The 0 to 30 mV input range makes the DRC-4710 and DRC-4720 compatible with most strain gage based load cell or pressure transducer outputs. Two models are available, one with 0 to 10 Vdc output (DRC-4710), and the other with 4 to 20 mA output (DRC-4720). Connections are made via easily accessible screw terminal blocks. Zero and Span adjustment potentiometers are located externally as well for easy access. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003cbr\u003e INPUT\u003cbr\u003e Input Range: \u003c\/b\u003e0 to 10 mV, 0 to 20 mV, 0 to 30 mV (dip switch selectable)\u003cbr\u003e \u003cb\u003ePower\u003c\/b\u003e: 18 to 26 Vdc (350 Ω Bridge)\u003cb\u003e\u003cbr\u003eLinearity: \u003c\/b\u003e±0.01%\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e 0.05%\/°C\u003cbr\u003e \u003cb\u003eInput Offset Voltage: \u003c\/b\u003e±70 µV\u003cbr\u003e \u003cb\u003eInput Offset Voltage Temperature Coefficient: \u003c\/b\u003e0.7 µV\/°C\u003cbr\u003e \u003cb\u003eCommon Mode Voltage: \u003c\/b\u003e0 to 5V\u003cbr\u003e \u003cb\u003eCommon Mode Rejection (DC):\u003c\/b\u003e 100 dB\u003cbr\u003e \u003cb\u003eInput Noise: \u003c\/b\u003e0.3 µV pp typ (0.1 to 10 Hz) \u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003cbr\u003e Output Range: DRC-4710: \u003c\/b\u003e0 to 10 Vdc\u003cbr\u003e \u003cb\u003eDRC-4720: \u003c\/b\u003e4 to 20 mA\u003cbr\u003e \u003cb\u003eLoad Current (DRC-4710):\u003c\/b\u003e 5 mA max\u003cbr\u003e \u003cb\u003eCompliance Voltage (DRC-4720): \u003c\/b\u003e5.5V max\u003cbr\u003e \u003cb\u003eLoop Resistance (DRC-4720): \u003c\/b\u003e250 Ω max\u003cbr\u003e \u003cb\u003eFrequency Response (2-Pole Filter): \u003c\/b\u003eDC to 10 Hz\u003cbr\u003e \u003cb\u003eTotal RMS Gain Temperature Coefficient: \u003c\/b\u003e0.007%\/°C \u003cbr\u003e\u003cbr\u003e \u003cb\u003eBRIDGE EXCITATION SUPPLY\u003cbr\u003e Fixed Output: \u003c\/b\u003e10V ±1.5%\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e 0.05%\/°C\u003cbr\u003e \u003cb\u003eLoad Current: \u003c\/b\u003e30 mA max \u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e Power: 18 to 26 Vdc\u003cbr\u003e \u003cb\u003ePower Consumption (One 350 Ω Bridge): \u003c\/b\u003e\u003cbr\u003eDRC-4710: 0.96 W (40 mA @ 24 Vdc)\u003cbr\u003e DRC-4720: 1.32 W (55 mA @ 24 Vdc)\u003cbr\u003e \u003cb\u003eOperating Ambient: \u003c\/b\u003e0 to 55°C (32 to 131°F)\u003cbr\u003e \u003cb\u003eStorage Temperature: \u003c\/b\u003e-40 to 80°C (-40 to 176°F)\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 96 H x 27 W x 42 mm D (3.78 x 1.06 x 1.65\")\u003cbr\u003e \u003cb\u003eWeight: \u003c\/b\u003e85 g (3 oz) \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818440958247,"sku":"DRC-4710-4720-Sig-Cond","price":680.28,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818440991015,"sku":"DRC-4710-4720-Sig-Cond","price":680.28,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drc-4710_4720_l_mmbkhjrj4kaxeduz.jpg?v=1741345875"},{"product_id":"din-rail-frequency-input-signal-conditioner-configurable","title":"DIN Rail Frequency Input Signal Conditioner | Configurable","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e \u003cb\u003eAdvanced Features\u003c\/b\u003e\u003cbr\u003e • The DRST-FR signal converter can be configured with OMSET software in a standard PC and the TXUN-KIT communications unit.\u003cbr\u003e \u003cb\u003eApplication\u003c\/b\u003e\u003cbr\u003e • The f\/I function performs frequency to current and voltage conversion.\u003cbr\u003e • The f\/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.\u003cbr\u003e • A scale factor may be entered in all functions. Using both digital inputs, pulse addition or subtraction are possible.\u003cbr\u003e • The frequency generator function is used as e.g. a time base or clock generator.\u003cbr\u003e • Input and supply polarity reversal protection. Current and voltage output signals galvanically separated from the supply and the inputs.\u003cbr\u003e • Programmable digital outputs including NPN, PNP or relay options.\u003cbr\u003e \u003cb\u003eTechnical Characteristics\u003c\/b\u003e\u003cbr\u003e • 5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.\u003cbr\u003e • Analog current output can be configured to any current within 0 to 20 mA range.\u003cbr\u003e • Voltage output range is selectable between 0 to 10 Vdc and 0 to 1 Vdc by use of internal jumpers.\u003cbr\u003e • Input range: Frequency: 0 to 20,000 Hz Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0\u003cbr\u003e • Output range: Current and voltage output: 0 to 20 mA \/ 0...10 V Relay outputs: 0 to 20 Hz NPN and PNP output as f\/f: 0 to 1000 Hz NPN and PNP output as generator: 0 to 20,000 Hz\u003cbr\u003e\u003cbr\u003e \u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEnvironmental Conditions\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -20 to 60°C\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e \u0026lt; 95% RH (non-cond.)\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eMechanical Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions (HxWxD):\u003c\/b\u003e 109 x 23.5 x 130 mm\u003cbr\u003e \u003cb\u003eWeight Approx:\u003c\/b\u003e 240 g\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN 46277\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 1 x 2.5 mm2 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm\u003cbr\u003e \u003cb\u003eCommon Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage, Universal:\u003c\/b\u003e21.6 to 253 Vac, 50 to 60 Hz or 19.2 to 300 Vdc\u003cbr\u003e \u003cb\u003eFuse:\u003c\/b\u003e 400 mA SB \/ 250 Vac\u003cbr\u003e \u003cb\u003eMax. Required Power:\u003c\/b\u003e 3.5 W\u003cbr\u003e \u003cb\u003eInternal Power Dissipation:\u003c\/b\u003e3 W\u003cbr\u003e \u003cb\u003eIsolation Voltage\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eIsolation Voltage, Test\/Working:\u003c\/b\u003e 3.75 kVac \/ 250 Vac\u003cbr\u003e \u003cb\u003ePower-Up Delay:\u003c\/b\u003e 0 to 999 s\u003cbr\u003e \u003cb\u003eWarm-Up Time:\u003c\/b\u003e1 min.\u003cbr\u003e \u003cb\u003eProgramming:\u003c\/b\u003e Loop Link\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e Min. 60 dB\u003cbr\u003e \u003cb\u003eResponse Time, Analog:\u003c\/b\u003e\u0026lt; 60 ms + period\u003cbr\u003e \u003cb\u003eResponse Time, Digital Output:\u003c\/b\u003e \u0026lt; 50 ms + period\u003cbr\u003e \u003cb\u003eSignal Dynamics, Output:\u003c\/b\u003e16 bit\u003cbr\u003e \u003cb\u003eEffect of Supply Voltage Change:\u003c\/b\u003e \u0026lt; 0.005% of span\/Vdc\u003cbr\u003e \u003cb\u003eAuxiliary Voltage: NAMUR Supply:\u003c\/b\u003e 8.3 Vdc ±0.5 Vdc \/ 8 mA\u003cbr\u003e \u003cb\u003eS0 Supply:\u003c\/b\u003e 17 Vdc\/20 mA\u003cbr\u003e \u003cb\u003eNPN\/PNP Supply:\u003c\/b\u003e 17 Vdc\/20 mA\u003cbr\u003e \u003cb\u003eSpecial Supply (Programmable):\u003c\/b\u003e 5 to 17 Vdc\/20 mA\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e\u0026lt; ±0.01% of span\/°C\u003cbr\u003e \u003cb\u003eLinearity Error:\u003c\/b\u003e \u0026lt; 0.1% of span\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt; ±0.5%\u003cbr\u003e \u003cb\u003eInput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCommon Input Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMax. Offset:\u003c\/b\u003e 90% of selected max. frequency\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 20 kHz\u003cbr\u003e \u003cb\u003eMin. Measurement Range:\u003c\/b\u003e 0.001 Hz\u003cbr\u003e \u003cb\u003eMax. Frequency, with Input Filter ON:\u003c\/b\u003e 50 Hz\u003cbr\u003e \u003cb\u003eMin. Period Time with Input Filter ON:\u003c\/b\u003e 20 ms\u003cbr\u003e \u003cb\u003eInput Types:\u003c\/b\u003e NAMUR acc. to DIN 19234\u003cbr\u003e \u003cb\u003eInput Types:\u003c\/b\u003eTacho\u003cbr\u003e \u003cb\u003eInput Types:\u003c\/b\u003eNPN\/PNP\u003cbr\u003e \u003cb\u003eInput Types:\u003c\/b\u003e2-phase encoder\u003cbr\u003e \u003cb\u003eInput Types:\u003c\/b\u003eTTL\u003cbr\u003e \u003cb\u003eInput Types:\u003c\/b\u003eS0 acc. to DIN 43864\u003cbr\u003e \u003cb\u003eOutput Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCommon Output Specifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eUpdating Time:\u003c\/b\u003e 20 ms\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 20 mA\u003cbr\u003e \u003cb\u003eMin. Signal Range:\u003c\/b\u003e 5 mA\u003cbr\u003e \u003cb\u003eLoad (@ Current Output):\u003c\/b\u003e ≤ 600 Ω\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤ 0.01% of span\/100 Ω\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e \u0026lt; 23 mA\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 10 Vdc\u003cbr\u003e \u003cb\u003eMin. Signal Range:\u003c\/b\u003e 250 mV\u003cbr\u003e \u003cb\u003eLoad (@ Voltage Output):\u003c\/b\u003e ≥ 500 kΩ\u003cbr\u003e \u003cb\u003eRelay Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMax. Switching Frequency:\u003c\/b\u003e 20 Hz\u003cbr\u003e \u003cb\u003eMax. Voltage:\u003c\/b\u003e 250 VRMS\u003cbr\u003e \u003cb\u003eMax. Current:\u003c\/b\u003e 2 AAC\u003cbr\u003e \u003cb\u003eMax. AC Power:\u003c\/b\u003e 100 VA\u003cbr\u003e \u003cb\u003eMax. Load at 24 Vdc:\u003c\/b\u003e1 A\u003cbr\u003e \u003cb\u003eOther Output Types:\u003c\/b\u003e Active outputs (NPN\/PNP)\u003cbr\u003e \u003cb\u003eOther Output Types:\u003c\/b\u003e f\/f Converter Output\u003cbr\u003e \u003cb\u003eOther Output Types:\u003c\/b\u003e Frequency generator\u003cbr\u003e \u003cb\u003eOf Span:\u003c\/b\u003e = of the presently selected range\u003cbr\u003e \u003cb\u003eObserved Authority Requirements\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eEMC:\u003c\/b\u003e 2014\/30\/EU\u003cbr\u003e \u003cb\u003eLVD:\u003c\/b\u003e 2014\/35\/EU\u003cbr\u003e \u003cb\u003eEAC:\u003c\/b\u003e TR-CU 020\/2011\u003cbr\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818441548071,"sku":"DRST-FR-Freq-Sig-Cond","price":1136.3,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818441580839,"sku":"DRST-FR-Freq-Sig-Cond","price":1136.3,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drst-fr_l_1z0vwet2top6fv4m.jpg?v=1741345896"},{"product_id":"din-rail-universal-input-signal-conditioner-w-slim-housing","title":"DIN Rail Universal Input Signal Conditioner w\/ Slim Housing","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-U isolated universal input \u003cb\u003eDIN rail signal conditioner\u003c\/b\u003e provides a competitive choice in terms of both price and technology for galvanic isolation of process signals to SCADA systems or PLC equipment.\u003cbr\u003e\u003cbr\u003e The DRSL-U accepts thermocouple, RTD, linear resistance, potentiometer, voltage or current input and converts these signals to linear voltage or current output. The unit offers isolation between input, output and supply, provides surge suppression and protects control systems from transients and noise.\u003cbr\u003e\u003cbr\u003e The DRSL-U also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. The DRSL-U is easily configured by using the DRSL-DISPLAY programming interface in conjunction with the DRSL-ADAPTOR configuration adaptor.\u003cbr\u003e\u003cbr\u003e The DRSL-DISPLAY has a 4 line LCD display with scrolling help text in 7 languages (English, French, German, Italian, Spanish, Danish and Swedish) which guides the user through all the configuration steps. The DRSL-U is designed with electronic hardware switches, consequently it is not necessary to open the device to set any internal DIP-switches.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eINPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRTD Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Type:\u003c\/b\u003e Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000, linear resistance, potentiometer\u003cbr\u003e \u003cb\u003eCable Resistance Per Wire:\u003c\/b\u003e 50 Ω max\u003cbr\u003e \u003cb\u003eSensor Current:\u003c\/b\u003e 0.2 mA nominal\u003cbr\u003e \u003cb\u003eEffect of Sensor Cable Resistance (3-Wire\/4-Wire RTD):\u003c\/b\u003e \u0026lt;0.002 Ω \/ Ω\u003cbr\u003e \u003cb\u003eSensor Error Detection:\u003c\/b\u003e Yes\u003cbr\u003e \u003cb\u003eShort Circuit Detection:\u003c\/b\u003e \u0026lt;15 Ω\u003cbr\u003e \u003cb\u003eLinear Resistance Input Range:\u003c\/b\u003e 0 to 10,000 Ω\u003cbr\u003e \u003cb\u003ePotentiometer Input Range:\u003c\/b\u003e 10 to 100 kΩ\u003cbr\u003e \u003cb\u003eThermocouple Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Types:\u003c\/b\u003e J, K, T, E, R, S, B, N, L, U, W3, W5, LR\u003cbr\u003e \u003cb\u003eCold Junction Compensation (CJC) Via Internally Mounted Sensor:\u003c\/b\u003e ±(2.0°C + 0.4°C * Δt) (Δt = internal temperature-ambient temperature)\u003cbr\u003e \u003cb\u003eSensor Error Detection:\u003c\/b\u003e Yes\u003cbr\u003e \u003cb\u003eSensor Error Current:\u003c\/b\u003e 2 µA nominal (when detecting)\u003cbr\u003e \u003cb\u003eCurrent Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 20 mA\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 20 mA and 4 to 20 mA\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e 20 Ω + PTC 50 Ω nominal\u003cbr\u003e \u003cb\u003e2-Wire Transmitter Supply:\u003c\/b\u003e \u0026gt;15 V\/20 mA\u003cbr\u003e \u003cb\u003eVoltage Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 12V\u003cbr\u003e \u003cb\u003eProgrammable Measurement Ranges:\u003c\/b\u003e 0 to 1V, 0.2 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V\u003cbr\u003e \u003cb\u003eInput Resistance:\u003c\/b\u003e 10 MΩ nominal \u003cbr\u003e\u003cbr\u003e \u003cb\u003eOUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to 20 mA (span)\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 20 mA, 4 to 20 mA, 20 to 0 mA and 20 to 4 mA\u003cbr\u003e \u003cb\u003eLoad:\u003c\/b\u003e 20 mA\/600 Ω\/15 Vdc max\u003cbr\u003e \u003cb\u003eLoad Stability:\u003c\/b\u003e ≤0.01% of span\/100 Ω (span=currently selected measurement range)\u003cbr\u003e \u003cb\u003eRange Limits (NAMUR NE43 Out of Range):\u003c\/b\u003e Below 3.8 mA or above 20.5 mA for 4 to 20 mA output; 0 mA or above 20.5 mA for 0 to 20 mA output\u003cbr\u003e \u003cb\u003eSensor Error Detection:\u003c\/b\u003e Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output\u003cbr\u003e \u003cb\u003eCurrent Limit:\u003c\/b\u003e ≤28 mA\u003cbr\u003e \u003cb\u003eVoltage Output\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSignal Range:\u003c\/b\u003e 0 to10 Vdc\u003cbr\u003e \u003cb\u003eProgrammable Signal Ranges:\u003c\/b\u003e 0 to 1V, 0.2 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V, 1 to 0.2V, 1 to 0V, 5 to 1V, 5 to 0V, 10 to 2V and 10 to 0V\u003cbr\u003e \u003cb\u003eLoad (Min):\u003c\/b\u003e \u0026gt;10 kΩ\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 16.8 to 31.2 Vdc via power rail or connectors\u003cbr\u003e \u003cb\u003ePower Consumption:\u003c\/b\u003e 1.2 W max\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 0.4 W typical, 0.65 W max\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input\/output\/power\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eStatus LED:\u003c\/b\u003e Green LED indicates operational status of the unit and input sensor\u003cbr\u003e \u003cb\u003eNormal Operation:\u003c\/b\u003e Flashes for 15 ms at 13 Hz rate\u003cbr\u003e \u003cb\u003eSensor Error:\u003c\/b\u003e Flashes for 15 ms at 1 Hz rate\u003cbr\u003e \u003cb\u003eHardware Failure:\u003c\/b\u003e LED off\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%) for Temperature Input:\u003c\/b\u003e ≤1 s \u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%) for mA\/V input:\u003c\/b\u003e ≤400 ms\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e Absolute accuracy or accuracy from table on PDF (whichever is greater)\u003cbr\u003e \u003cb\u003eAbsolute Accuracy:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eAll Input Types:\u003c\/b\u003e ≤±0.1% of span (selected input range)\u003cbr\u003e \u003cb\u003eTemperature Coefficient:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eAll Input Types:\u003c\/b\u003e ≤± 0.01% of span\/°C\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span\u003cbr\u003e \u003cb\u003eExtended EMC Immunity NAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span (span = selected input range)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818442268967,"sku":"DRSL-U-Univ-Input-Sig-Cnd","price":592.89,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818442301735,"sku":"DRSL-U-Univ-Input-Sig-Cnd","price":592.89,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-u_l_jkejqn3slabiwdz5.jpg?v=1741345921"},{"product_id":"din-rail-conditioners-with-model-specific-input-dig-out-option","title":"DIN Rail Conditioners with Model Specific Input | Dig. Out option","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cb\u003e\u003cspan style=\"color: blue;\"\u003e This product is no longer available.  Please see\u003ca href=\"https:\/\/www.omega.com\/en-us\/communication-and-connectivity\/signal-conditioners-and-transmitters\/signal-conditioners\/drst-un-series\/p\/DRST-UN\" class=\"blLink\"\u003e DRST-UN\u003c\/a\u003e with similar features at a lower price.\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e \u003cdiv id=\"description\" class=\"contentBlock fixedPadding\"\u003e\u003cspan class=\"descCopyPP\"\u003e\u003cbr\u003e\u003cbr\u003e The iD Series signal conditioners combine the accuracy of laboratory instrumentation with the performance required by demanding industrial applications. The iD Series signal conditioners are ideal for those applications in Data Acquisition, Test \u0026amp; Measurement, Process Control, and Industrial Automation where accuracy, performance, and reliability are critically important. The iD Series signal conditioners mount on a 35mm DIN rail, and operate on any voltage between 10-32 DC power. (A matching 24 Vdc 850 mA switching power supply is also available.) The devices feature three-way isolation of up to 1800 V between the signal inputs, outputs, and power supply. \u003cbr\u003e\u003cbr\u003e The iD series feature seven (7) models designed for each of the most widely measured signal inputs: Process (DC) Voltage and Current; Strain Gage; Thermocouples; RTD's; AC Voltage; AC Current; Frequency\/Pulse. The iD series devices are designed to work directly with a variety of sensors and transducers; no other components are necessary. For sensors such as RTD's, strain gages, and some process transducers, precise stable excitation is provided directly from the iD module. \u003cbr\u003e\u003cbr\u003e The iD series are available with two different types of signal outputs: Analog or Digital. The iDRN series provides a totally scalable analog output in DC voltage or current. The iDRX series provide a digital RS-485 output. Both iD Series signal conditioners are intelligent microprocessor based instruments that can be scaled and programmed by computer via serial communications, or over an Ethernet network. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eiDRN SERIES ANALOG OUTPUT\u003c\/b\u003e\u003cbr\u003e The iDRN series feature a 0-10 Vdc, or 0-20 mA (including 4-20 mA) analog output signal that is typically scaled to be directly proportional to the input signal. It is an ideal component in a system with PLCs or PC's with analog data acquisition boards.\u003cbr\u003e The iDRN series are an excellent choice for applications that demand an extra measure of accuracy and performance that is not possible with conventional \"analog\" signal conditioners or transmitters. Unlike conventional analog devices that are scaled by adjusting zero and span pots, the programmable, micro-processor based iDRN instruments are scaled precisely on a PC with free and simple Windows software. The iDRN modules connect directly to a PC's RS-232 Serial Communications port for programming and scaling. Once the module is configured, the parameters are saved in nonvolatile memory. The device can be disconnected from the PC, or the RS-232 output from the module can be used for continuous data acquisition in addition to the analog output.\u003cbr\u003e Alternatively, the iDRN signal conditioner can be connected to a PC's Ethernet port or an Ethernet network using the EIT-D module as a Serial\/Ethernet bridge. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eFREE SETUP and CONFIGURATION\u003c\/b\u003e\u003cbr\u003e If an iDRN signal conditioner is not going to be connected to a computer, it can be ordered preconfigured by the factory at no extra charge. The user can select the input types, ranges and output scale, and OMEGA will program the instruments to those specific requirements in our calibration lab prior to shipment. For custom factory setup and scaling of the iDRN model, please specify the -FS option. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eiDRX SERIES DIGITAL OUTPUT\u003c\/b\u003e\u003cbr\u003eThe iDRX Series Signal Conditioners provide highly accurate digital outputs. Each module provides an RS-485 Serial output that can be transmitted directly to computers and other devices with serial communications capability, or converted to Ethernet. On an RS-485 bus, up to 32 modules can be connected over a distance of 1200 m (4000 ft) on a single pair of wires. With optional RS-485 repeaters, up to 254 modules may be connected to a single RS-485 port. The iDRX Series digital conditioners may be connected to an RS-485 bus using either screw terminator or RJ-12 connector. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eASCII AND MODBUS\u003c\/b\u003e The user can select between an easy-to-use, straightforward ASCII protocol, or the popular MODBUS protocol found in many existing industrial installations. With the simple ASCII commands, writings programs using the iDRX does not require special drivers or libraries. In addition, many off-the-shelf software packages can be used with the iDRX devices without any programming. OMEGA also provides a number of useful programs and demos for the iDRX at no charge. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eOPC Server and ACTIVE X CONTROLS\u003c\/b\u003e\u003cbr\u003e OMEGA offers an optional OPC Server (OLE for Process Control) and ActiveX Controls for the iDRX Series. These programs make it easy to integrate the iDRX devices with information systems using Active Containers such as Microsoft Visual Basic and Microsoft Excel as well as with popular OLE and OPC compliant data acquisition, process control, and industrial automation software from OMEGA™, Iconics, Wonderware, Intellution, Rockwell Automation, and GE Cimplicity among others. \u003cbr\u003e\u003cbr\u003e \u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bordercolor=\"black\"\u003e\u003ctbody\u003e\n\u003ctr bgcolor=\"#d6b284\"\u003e\n\u003ctd\u003e\u003cb\u003eInput\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eThermocouple\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eRTD\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eac Voltage\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eac Current\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eProcess\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eStrain\/Bridge\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eFrequency Pulse\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr bgcolor=\"#d6b284\"\u003e\n\u003ctd\u003e\u003cb\u003eModel No.\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eiDRN-TC\u003cbr\u003eiDRX-TC\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eiDRN-RTD\u003cbr\u003eiDRX-RTD\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eiDRN-ACV\u003cbr\u003eiDRX-ACV\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eiDRN-ACC\u003cbr\u003eiDRX-ACC\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eiDRN-PR\u003cbr\u003eDRX-PR\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eiDRN-ST\u003cbr\u003eiDRX-ST\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eiDRN-FP\u003cbr\u003eiDRX-FP\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e \u003ctd\u003eThermocouple\u003cbr\u003etemperature\u003cbr\u003esensor\u003c\/td\u003e \u003ctd\u003eRTD Temperature\u003cbr\u003esensor\u003cbr\u003ePt100, 500, 1000Ohm\u003c\/td\u003e \u003ctd\u003eac Voltage\u003c\/td\u003e \u003ctd\u003eac Current\u003c\/td\u003e \u003ctd\u003edc Millivolt\u003cbr\u003eVolt\u003cbr\u003eand Current\u003c\/td\u003e \u003ctd\u003eMillivolt\u003c\/td\u003e \u003ctd\u003eNAMUR\u003cbr\u003eContact closure\u003cbr\u003elow level\u003cbr\u003eopen collector\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e \u003ctd\u003eJ, K, T, E,\u003cbr\u003eR, S, B, N, J DIN\u003cbr\u003ethermocouple full range\u003c\/td\u003e \u003ctd\u003ealpha = 385, 392\u003cbr\u003eFull range of RTD\u003cbr\u003e2, 3 or 4-wire\u003c\/td\u003e \u003ctd\u003eFull Scale Range:\u003cbr\u003e400 mV to 400 V\u003c\/td\u003e \u003ctd\u003eFull Scale Range:\u003cbr\u003e10 mA to\u003cbr\u003e5 A\u003c\/td\u003e \u003ctd\u003eFull Scale Range:\u003cbr\u003e400 mV to +\/-10 V\u003cbr\u003e0 to 20 mA\u003c\/td\u003e \u003ctd\u003e0 to 30 mV\u003cbr\u003e0 to 100 mV\u003cbr\u003e±100 mV\u003c\/td\u003e \u003ctd\u003eFull Scale Range\u003cbr\u003e20K - 200M pulses\u003cbr\u003e0-50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e \u003ctd\u003e±1°C\u003c\/td\u003e \u003ctd\u003e±0.5°C\u003c\/td\u003e \u003ctd\u003e0.20%\u003c\/td\u003e \u003ctd\u003e0.20%\u003c\/td\u003e \u003ctd\u003e0.1% FS\u003c\/td\u003e \u003ctd\u003e0.2% FS\u003c\/td\u003e \u003ctd\u003e0.1%FS\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e \u003ctd\u003e0.1°C\u003c\/td\u003e \u003ctd\u003e0.1°C\u003c\/td\u003e \u003ctd\u003e10 to 14 Bit\u003c\/td\u003e \u003ctd\u003e10 to 14 Bit\u003c\/td\u003e \u003ctd\u003e12 to 15 Bit\u003c\/td\u003e \u003ctd\u003e13 to 15 Bit\u003c\/td\u003e \u003ctd\u003e15 to 19 Bit\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e \u003ctd colspan=\"7\" align=\"center\"\u003eiDRX Series: 2-wire (half duplex) RS-485\/iDRN Series: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eExcitation\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003ctd\u003e14 Vdc @\u003cbr\u003e25 mA\u003c\/td\u003e \u003ctd\u003e10 V @\u003cbr\u003e30 mA\u003c\/td\u003e \u003ctd\u003e5, 8.2 and 12.5 Vdc\u003cbr\u003e@ 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818442531111,"sku":"IDRN-IDRX-Srs-Sig-Cond","price":689.75,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818442563879,"sku":"IDRN-IDRX-Srs-Sig-Cond","price":689.75,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drn-drx_lrdxrycdurbtwbk5.jpg?v=1741345943"},{"product_id":"din-rail-voltage-conversion-i-o-modules-ttl-to-plc-levels","title":"DIN Rail Voltage Conversion I\/O Modules | TTL to PLC Levels","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   DR-IO Series DIN rail mount input\/output modules are ideal for connecting real world discrete signals to a computer interface and other electronic equipment. Most computer interfaces can only sense or generate low level TTL (0\/5Vdc) signals. The DR-IO-OAC and DR-IO-ODC output modules can be used to sense high level ac and dc signals. The compact design of the DR-IO modules permit high density mounting on a standard DIN rail. The input modules are available with negative and positive logic versions. Negative logic modules produce a high logic signal when the input signal from the field goes low and a low logic signal when the field input goes high. With the positive logic modules, the logic signal follows the field signal that is, the logic signal is high when the field signal is high and low when the field signal is low.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFor complete product specifications see the Related Links section at the bottom of this page.\u003c\/b\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818443022631,"sku":"DR-IO-Sig-Cond-TTL-to-PLC","price":125.8,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818443055399,"sku":"DR-IO-Sig-Cond-TTL-to-PLC","price":125.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dr-io_v4nkn5w74vfmi3zh.jpg?v=1741345965"},{"product_id":"din-rail-strain-gage-load-cell-transmitter-w-bipolar-ma-v-output","title":"DIN Rail Strain Gage\/Load Cell Transmitter w\/ Bipolar mA\/V Output","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The TXDIN1600S is a “smart” powered bridge amplifier for use with strain gauges or load cell signals. The product has a built-in capability to scale the input signal to a process value while the output stage offers either voltage, bipolar voltage or active\/passive current re-transmission signals.\u003cbr\u003e\u003cbr\u003e The TXDIN1600S requires an AC\/DC power supply that will operate in the range (10 to 48) Vdc and 10 to 32 Vac making the device ideal for battery operation. An additional volt free contact input is available for tare setting using a remote switch. The high precision input stage of the device allows for a bridge excitation voltage of 5 Vdc to be used as opposed to the traditional 10 Vdc. This reduces the power requirement for the bridge supply and up to four bridges (cells) may be connected to the input.\u003cbr\u003e\u003cbr\u003e The device is provided with two front panel push buttons that can be configured to perform one of two functions or be disabled. Set as function 1, the buttons allow the user to push button configure the output range at high and low scale against a live input signal, set as function 2, the buttons allow the operator to trim the output at high and low scale. The device uses ratio metric measurement to obtain high stability.\u003cbr\u003e\u003cbr\u003e The product uses a USB port for configuration, together with a simple to use menu driven software configuration tool, allowing the user to take advantage of the product’s comprehensive specification. Additionally, the user may read live process data when connected to the PC, allowing for offset and span calibration.\u003cbr\u003e\u003cbr\u003e If configuration is not specified at the time of order, the product will be shipped with the default range 2 mV\/V input, 4 to 20 mA output.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eBridge Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eFull Range:\u003c\/b\u003e -7.6 to 7.6 mV\/V (-38 to 38) mV at 5V excitation\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e Four wire radiometric\u003cbr\u003e \u003cb\u003eDrift:\u003c\/b\u003e \u0026lt; ± 0.05%\u003cbr\u003e \u003cb\u003eLinearity:\u003c\/b\u003e ± 0.01%\u003cbr\u003e \u003cb\u003eUpdate:\u003c\/b\u003e Selectable, 10 or 80 SPS (samples per second)\u003cbr\u003e \u003cb\u003eBridge Excitation\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eVoltage:\u003c\/b\u003e 5 Volts DC ± 0.1 V @ 59 mA\u003cbr\u003e \u003cb\u003eBridge Impedance:\u003c\/b\u003e Total 85 to 10000 Ω (operates with four 350 Ω cell in parallel)\u003cbr\u003e \u003cb\u003eTare Input\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType\u003c\/b\u003e Remote volt free contact, up to 10 meter distance\u003cbr\u003e \u003cb\u003eOutput Current\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCurrent Source:\u003c\/b\u003e Range (0 to 21.5) mA, max load 750 Ω\u003cbr\u003e \u003cb\u003eCurrent Sink:\u003c\/b\u003e Range 0 to 21.5 mA, supply 10 to 30 Vdc, voltage effect 0.2 uA\/V\u003cbr\u003e \u003cb\u003eAccuracy:\u003c\/b\u003e (mA out\/2000) or 5 uA whichever is the greater, drift 1 uA\/°C\u003cbr\u003e \u003cb\u003eOutput Voltage\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 0 to 10.1 V or -10.1 to 10.1 V, accuracy ± 5 mV\u003cbr\u003e \u003cb\u003eCurrent Drive:\u003c\/b\u003e ± 2 mA, min load 5000 Ω @ 10 V\u003cbr\u003e \u003cb\u003ePush Button Configuration\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e Independent “Low” “High” front panel push buttons allow user to manuallyset low and high output points\u003cbr\u003e \u003cb\u003eSupply\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eRange:\u003c\/b\u003e 10 to 48 Vdc, 10 to 32 Vac protected by internal 500 mA resettable fuse\u003cbr\u003e \u003cb\u003ePower:\u003c\/b\u003e \u0026lt; 1 W full power\u003cbr\u003e \u003cb\u003eGeneral\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Supply to input to output 500 Vdc\u003cbr\u003e \u003cb\u003eIndication:\u003c\/b\u003e LED, green when output -0.1 to 100.1%, all else red\u003cbr\u003e \u003cb\u003eUser Interface\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e USB 2.0\u003cbr\u003e \u003cb\u003eBaud rate\u003c\/b\u003e: 19,200 baud\u003cbr\u003e \u003cb\u003eEquipment:\u003c\/b\u003e PC running Windows XP or later, USB cable.\u003cbr\u003e \u003cb\u003eUser Interface Functions\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCalibration Scaling:\u003c\/b\u003e (2 to 6) points signal against process\u003cbr\u003e \u003cb\u003eFilter:\u003c\/b\u003e (1 to 20) seconds to reach 70% of final value\u003cbr\u003e \u003cb\u003eTare:\u003c\/b\u003e Remote set tare offset with programmable user set point\u003cbr\u003e \u003cb\u003eActive Calibration:\u003c\/b\u003e Active calibration against live load cell\u003cbr\u003e \u003cb\u003eProcess Units:\u003c\/b\u003e 4 characters\u003cbr\u003e \u003cb\u003eTag Number:\u003c\/b\u003e 20 characters\u003cbr\u003e \u003cb\u003eProcess Output:\u003c\/b\u003e Process output range\u003cbr\u003e \u003cb\u003eSignal Output:\u003c\/b\u003e Select type, signal range\u003cbr\u003e \u003cb\u003eActive Scaling Output:\u003c\/b\u003e Set output process range against active sensor input\u003cbr\u003e \u003cb\u003eSensor Information:\u003c\/b\u003e Model, sensitivity and balance\u003cbr\u003e \u003cb\u003eEnvironment\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Ambient:\u003c\/b\u003e -30 to 70°C (-22 to 158ºF); 10 to 90%RH (non condensing)\u003cbr\u003e \u003cb\u003eStorage Ambient:\u003c\/b\u003e -30 to 70°C (-22 to 158ºF); 10 to 90%RH (non condensing)\u003cbr\u003e \u003cb\u003eConfiguration Ambient:\u003c\/b\u003e 10 to 30°C (50 to 86ºF)\u003cbr\u003e \u003cb\u003eInstallation Enclosure:\u003c\/b\u003e DIN rail enclosure offering Protection ≥ IP65\u003cbr\u003e \u003cb\u003eApprovals\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eCE:\u003c\/b\u003e BS EN 61326\u003cbr\u003e \u003cb\u003eMechanical\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eStyle\u003c\/b\u003e DIN 43880, color grey, material Polyimide 6.6\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e \u0026lt; 70 g\u003cbr\u003e \u003cb\u003eTerminals\u003c\/b\u003e 2.5 mm (0.10\") maximum \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818443252007,"sku":"TXDIN1600S-Transmitter","price":509.75,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818443284775,"sku":"TXDIN1600S-Transmitter","price":509.75,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/txdin1600s_l_rdg68qdcce5ufipf.jpg?v=1741345988"},{"product_id":"din-rail-universal-input-transmitter-with-push-button-user-trim","title":"DIN Rail Universal Input Transmitter with Push Button User Trim","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The TXDIN1600 Series is a new generation DIN rail mounted temperature transmitter. It has been designed to accept most common process and temperature sensor inputs and provide the user with a standard two wire 4 to 20 mA output signal. Isolation is provided between input and output and all temperature ranges are linear to temperature.\u003cbr\u003e\u003cbr\u003e Designed for ease of use, our latest USB interface is fitted for quick and easy configuration. Just connect a standard USB cable between the TXDIN1600 and your PC. Using our free configuration software, your PC will automatically upload the existing configuration data and guide you through any changes you wish to make. To further help save time, the TXDIN1600 does not need to be wired to a power supply during the configuration process, it is powered via the USB interface from your PC.\u003cbr\u003e\u003cbr\u003eThe TXDIN1600 is also provided with user push button trim, allowing trim adjustments at both 4 mA and 20 mA. The user trim function can be locked during configuration if not required. The range led indicates out of range input during normal operation, during user trim it is used to indicate the stage of trim.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eIsolation:\u003c\/b\u003e Input to output tested at 500 Vdc\u003cbr\u003e \u003cb\u003eAmbient:\u003c\/b\u003e Operating -20 to 70°C (-4 to 158°F) 10 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eStorage:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eApprovals:\u003c\/b\u003e CE tested to BS EN 61326\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 17.5 W x 56.4 L x 90 mm H (0.7 x 2.2 x 3.5\")\u003cbr\u003e \u003cb\u003eMaterial:\u003c\/b\u003e Polmide 6.6\u003cbr\u003e \u003cb\u003eSelf Extinguishing Terminals:\u003c\/b\u003e Screw terminal\u003cbr\u003e \u003cb\u003eCable:\u003c\/b\u003e 2.5 mm (0.1\") max\u003cbr\u003e \u003cb\u003eColor:\u003c\/b\u003e Gray Output\u003cbr\u003e\u003cbr\u003e \u003cb\u003eTXDIN1610\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e 2-wire current sink; signal range 4 to 20 mA; full range 3.8 to 24 mA\u003cbr\u003e \u003cb\u003eSupply:\u003c\/b\u003e 11 to 30 Vdc, 24V nominal giving max loop load of 600 R @ 24V\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e \u0026lt;500 ms to reach 95% of final value; start up time \u0026lt;3 s\u003cbr\u003e \u003cb\u003eCalibration Accuracy:\u003c\/b\u003e ±5 uA\u003cbr\u003e \u003cb\u003eLoop Effects:\u003c\/b\u003e Loop ripple 0.03% of FSR; supply sensitivity 0.05 uA\/°C; supply ripple rejection \u003cb\u003eProtection:\u003c\/b\u003e Reverse connection and over-voltage protection, max over voltage current 100 mA\u003cbr\u003e \u003cb\u003eUser Trim:\u003c\/b\u003e Raise and lower buttons, active for offset when output is between 3.8 to 6 mA, span between 18 to 22 mA, trim lock option\u003cbr\u003e\u003cbr\u003e \u003cb\u003eTXDIN1620\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e 3-wire voltage output with\u003cbr\u003e \u003cb\u003eprogrammable ranges:\u003c\/b\u003e 0 to 10, 0 to 5, 2 to 10, 1 to 5, and 0 to 1V\u003cbr\u003e \u003cb\u003eSupply:\u003c\/b\u003e 15 to 28 Vdc\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e \u0026lt;500 ms to reach 95% of final value; start up time \u0026lt;3 s\u003cbr\u003e \u003cb\u003eCalibration Accuracy:\u003c\/b\u003e ±5 mV\u003cbr\u003e \u003cb\u003eOutput Drive:\u003c\/b\u003e 2 mA driving 5 KΩ @ 10V\u003cbr\u003e \u003cb\u003eProtection:\u003c\/b\u003e Reverse connection and over-voltage protection, max over voltage current 100 mA\u003cbr\u003e \u003cb\u003eUser Trim:\u003c\/b\u003e Raise and lower buttons, active for offset when output is at offset and span, trim lock option\u003cbr\u003e\u003cbr\u003e \u003cb\u003eTXDIN1630\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eType:\u003c\/b\u003e Dual form C relay contacts\u003cbr\u003e \u003cb\u003eSupply:\u003c\/b\u003e 24 Vdc ±5% @ 40 mA max\u003cbr\u003e \u003cb\u003eResponse Time:\u003c\/b\u003e \u0026lt;500 ms to reach 95% of final value; start up time \u0026lt;3 s\u003cbr\u003e \u003cb\u003eContact Rating:\u003c\/b\u003e 250 Vac rms @ 1 A; 30 Vdc @ 1 A resistive load\u003cbr\u003e \u003cb\u003eTrip Type:\u003c\/b\u003e Individual trips A and B may be set at high or low level, full range setpoint plus adjustable\u003cbr\u003e \u003cb\u003eRanges:\u003c\/b\u003e Setpoint programmed on units, covering full range of input\u003cbr\u003e \u003cb\u003eHysteresis:\u003c\/b\u003e Set in units\u003cbr\u003e \u003cb\u003eProtection:\u003c\/b\u003e Reverse connection and over-voltage protection, max over voltage current 100 mA \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818443448615,"sku":"TXDIN1600-Series-Tx","price":910.75,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818443481383,"sku":"TXDIN1600-Series-Tx","price":910.75,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/txdin1600_series_l_h5i2jwxv5cv0ciug.jpg?v=1741346014"},{"product_id":"din-rail-ac-voltage-current-conditioners-w-4-wire-ac-power","title":"DIN Rail AC Voltage\/Current Conditioners w\/ 4-wire AC Power","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   The DRA-ACT-4I AND DRA-ACT-4V Series are isolated 4-wire ac current and ac voltage input DIN rail mount signal conditioners that convert the measured input into a proportional, linear and highly accurate 4-20 mA output current. The DRA-ACT-4I Series of ac current input models includes models for 0-1 Aac and 0-5 Aac inputs with a 4-20 mA output. The DRA-ACT-4V Series of ac voltage input models includes models for 0-150 Vac, 0-250 Vac and 0-400 Vac inputs again with a 4-20 mA output. Standard instrument power is 115 Vac, 50\/60 Hz. Units can also be configured for optional 230 Vac, 50\/60 Hz power. For complete safety, an internal transformer isolates the signal conditioner input from the output thus enabling these units to withstand large momentary inputs. Complete input to output isolation, high surge current capacity and high output signal-to-noise ratio make these signal conditioners highly immune to ground loop signals and RFI. Zero and span trimmers accessible from the front panel of these units facilitate fine tuning.  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818443841831,"sku":"DRA-ACT-4-Series-Sig-Cond","price":630.53,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818443874599,"sku":"DRA-ACT-4-Series-Sig-Cond","price":630.53,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/dra-act-4_l_3ocmlplbvarfbdzx.jpg?v=1741346036"},{"product_id":"din-rail-signal-conditioner-for-ac-lvdt-transducers","title":"DIN Rail Signal Conditioner for AC LVDT Transducers","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The LDX-D is a DC-powered conditioning module that can accept a wide range of analog inductive transducer types owing to its wide input gain. The signal polarity, span, and offset are adjustable. Output is selectable: ±10 Vdc voltage or ±20 mA current. The housing is a standard DIN rail enclosure that can clip directly to a 35 mm top-hat rail (TS35 EN50022). Transducers are connected via the screw terminals on the front of the LDX-D. Internal links and front-panel fine-adjustment potentiometers facilitate setup. By linking 2 LDX-D modules, users can perform some analog arithmetic functions, such as A + B, A– B, (A + B)\/2 and (A – B)\/2. \u003cbr\u003e \u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003ePower Requirement:\u003c\/b\u003e 10 to 30 Vdc\u003cbr\u003e \u003cb\u003eSupply Current:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eVoltage Range:\u003c\/b\u003e 140 mA @ 10 Vdc, 60 mA @ 30 Vdc\u003cbr\u003e \u003cb\u003eCurrent Range:\u003c\/b\u003e 160 mA @ 10 Vdc, 70 mA @ 30 Vdc\u003cbr\u003e \u003cb\u003eTransducer Excitation:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003ePrimary Voltage:\u003c\/b\u003e 3 Vrms nominal\u003cbr\u003e \u003cb\u003ePrimary Frequency (kHz):\u003c\/b\u003e 5-, 10- or 13-link selectable\u003cbr\u003e \u003cb\u003eSignal Input:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eInput Range:\u003c\/b\u003e 55 to 5000 mV\u003cbr\u003e \u003cb\u003eInput Load Resistance:\u003c\/b\u003e 100 kΩ\u003cbr\u003e \u003cb\u003eSignal Output:\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eVoltage Output:\u003c\/b\u003e Up to ±10 Vdc\u003cbr\u003e \u003cb\u003eCurrent Output:\u003c\/b\u003e Up to 20 mA into 150 Ω load\u003cbr\u003e \u003cb\u003eOutput Ripple:\u003c\/b\u003e \u0026lt;1 mVrms\u003cbr\u003e \u003cb\u003eOutput Offset:\u003c\/b\u003e Up to 100%\u003cbr\u003e \u003cb\u003eTemp Coefficient Gain:\u003c\/b\u003e \u0026lt;0.01% FSO\/°C\u003cbr\u003e \u003cb\u003eTemp Coefficient Offset:\u003c\/b\u003e \u0026lt;0.01% FSO\/°C\u003cbr\u003e \u003cb\u003eWarm-Up:\u003c\/b\u003e 15 minutes recommended\u003cbr\u003e \u003cb\u003eLinearity:\u003c\/b\u003e \u0026lt;0.1% FSO\u003cbr\u003e \u003cb\u003eBandwidth (-3 dB):\u003c\/b\u003e 500 Hz or 1 kHz, link selectable\u003cbr\u003e \u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temp:\u003c\/b\u003e 0 to 60°C (32 to 140°F)\u003cbr\u003e \u003cb\u003eStorage Temp:\u003c\/b\u003e -20 to 85°C (-4 to 185°F)\u003cbr\u003e \u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eTransducer:\u003c\/b\u003e Screw terminals\u003cbr\u003e \u003cb\u003ePower Supply:\u003c\/b\u003e Screw terminals\u003cbr\u003e \u003cb\u003eOutput Signal:\u003c\/b\u003e Screw terminals\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 120 g (4.2 oz)\u003cbr\u003e \u003cb\u003eCase Material:\u003c\/b\u003e Green polyamide \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818444398887,"sku":"LDX-D-AC-LVDT-Sig-Cond","price":1770.57,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818444431655,"sku":"LDX-D-AC-LVDT-Sig-Cond","price":1770.57,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/ldxd_l_ntbjqqzny5ytxhwl.jpg?v=1741346058"},{"product_id":"din-rail-conditioners-convert-voltage-or-bridge-input-to-rs-485","title":"DIN Rail Conditioners Convert Voltage or Bridge Input to RS-485","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e   The DIN-100 Sensor to Computer Modules are a family of data acquisition modules that convert analog input signals to serial data and transmit via RS-485 to a master unit which may be a computer or other processor-based equipment. The modules can measure temperature, bridge inputs, voltage, current, digital input or digital output signals. The modules provide direct connection to a wide variety of sensors and perform all signal conditioning, scaling, linearization and conversion to either linearized ASCII data values or Modbus RTU data values. Features such as address, baud rate, parity, echo, etc., are selectable using simple commands from your serial port.\u003cbr\u003e\u003cbr\u003e The selections are stored in nonvolatile EEPROM which maintains data even after power is removed.\u003cbr\u003e\u003cbr\u003e The key to the DIN-100 Series is that the modules are easy to use. You do not need engineering experience in complicated data acquisition hardware. With these modules, anyone familiar with a personal computer can construct a data acquisition system. This modular approach to data acquisition is extremely flexible, easy to use and cost effective. Data is acquired on a per channel basis so you only buy as many channels as you need. The modules can be mixed and matched to fit your application. They can be placed remote from the host and from each other. You can string up to 247 modules on a twisted pair of wires by using RS-485 with repeaters.\u003cbr\u003e\u003cbr\u003e All modules are supplied with screw terminal plug connectors. The connectors allow system expansion, reconfiguration or repair without disturbing field wiring. No charge utility software is available to make the DIN-100 modules easier to learn and use.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eTHEORY OF OPERATION\u003c\/b\u003e\u003cbr\u003e Each module is a complete singlechannel data acquisition system. Each unit contains analog signal conditioning circuits optimized for a specific input type. Sensor signals are converted to digital data with a microprocessor-controlled integrating A\/D converter. Offset and gain errors in the analog circuitry are continuously monitored and corrected using microprocessor techniques. The DIN-100 module converts the digital signal data and stores the resultant data in a memory buffer. The modules continuously convert data at the rate of 8 conversions per second and store the latest result in the buffer.\u003cbr\u003e\u003cbr\u003e Host processors may request data by sending a query to the module. The DIN-100 module will instantly respond by communicating the memory buffer data back to the host processor. Up to 247 modules may be linked to a single RS-485 port. Each module on a serial line is identified by a unique userprogrammable address. This addressing technique allows modules to be interrogated in any order.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDIGITAL INPUTS\/OUTPUTS\u003c\/b\u003e\u003cbr\u003e DIN-170 digital output modules contain open-collector transistor switches that may be controlled by the host processors. These switches may be used to control solid-state relays which in turn may control heaters, pumps and other power equipment. The digital inputs may be read by the host processor and used to sense the state of remote digital signals. They are ideal for sensing the state of limit or safety switches.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDIGITAL FILTER\u003c\/b\u003e\u003cbr\u003e The DIN-100 analog input modules include two unique programmable single pole digital filters. The filter is used to smooth analog data in noisy environments. Separate time constants may be specified for small and large signal changes. Typically a large time constant is specified for small signal changes to filter out noise and provide stable output readings. A smaller time constant may be chosen for large signal changes to provide fast response to such changes.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eUTILITY SOFTWARE\u003c\/b\u003e\u003cbr\u003e Complimentary Utility Software is included with each purchase order. The software is compatible with Windows XP, Vista, 7 and 8 operating systems and distributed on CD-ROM. The Utility Software simplifies configuration of all user-selectable options such as device address, baud rate and filtering constants. The latest version of the software is always downloadable from our web site.\u003cbr\u003e\u003cbr\u003e \u003cb\u003ePROCESS CONTROL SOFTWARE\u003c\/b\u003e\u003cbr\u003e Modbus RTU protocol is supported by virtually all commercial process control software programs available today.  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818444726567,"sku":"DIN-100-Series-Sig-Cond","price":512.73,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818444759335,"sku":"DIN-100-Series-Sig-Cond","price":512.73,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/din-100_wxbi3ocgcuxoyqzz.jpg?v=1741346082"},{"product_id":"din-strain-gauge-to-frequency-converter-for-micro-plcs","title":"DIN Strain Gauge to Frequency Converter for Micro PLCs","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cdiv class=\"contentBlock fixedPadding\" id=\"description\"\u003e \u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRP-8500 Series modules offer a low cost analog I\/O solution for micro PLCs. The series is ideal for discrete automation applications requiring one or two analog I\/O channels. All models in the series interface with the PLC high speed counter inputs or pulse outputs. Digital signal pulse-width is fixed at 50 µsec. They will accept a variety of analog inputs, such as thermocouple, RTD, strain gage, voltage, and current. Some DRP-8500 models can be connected to pulse outputs from a PLC, and will then provide an analog output. The DRP-8500 series modules have an isolated floating optocoupler transistor which provides DC isolation from the input, output and DC power. The output transistor is fully floating allowing either source or sink connection to the PLC. The DRP-8500 resolution is 12 bits. The DRP-8600 Series modules are designed to interface with the low-speed 24 Vdc logic inputs of a PLC for applications requiring additional analog inputs. The DRP-8600 modules output a square wave up 500 Hz with a 50-50 duty cycle, allowing the PLC to count the frequency producing better than 8- bit resolution, 1 part in 500. The DRP-8600 module has an isolated floating optocoupler transistor which provides DC isolation from the input, output and DC power. The output transistor is fully floating allowing either source or sink connection to the PLC. All modules are housed in a plastic case with a built-in U-foot for mounting on standard DIN rails. Connections are made to screw clamp terminals that accept wire sizes 22 AWG to 16 AWG. \u003cbr\u003e\u003cbr\u003e \u003cb\u003eCommon Specifications\u003c\/b\u003e (contact engineering for detailed specifications)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConnections\u003c\/b\u003e: Screw terminals, 22 to 16 AWG\u003cbr\u003e \u003cb\u003ePower\u003c\/b\u003e: 24 volts nominal\u003cbr\u003e \u003cb\u003eSize\u003c\/b\u003e: 42 mmH x 27 mmW x 96 mmL (1.65 x 1.06 x 3.78\")\u003cbr\u003e \u003cb\u003eWeight\u003c\/b\u003e: 85g (3 oz)\u003cbr\u003e\u003cbr\u003e \u003ctable border=\"1\" bordercolor=\"black\" cellpadding=\"3\" cellspacing=\"0\" width=\"660\"\u003e \u003ctr align=\"center\" bgcolor=\"#7CD0E0\"\u003e\n\u003ctd nowrap\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eModel Number\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eInput\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eOutput\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd bgcolor=\"#7CD0E0\" colspan=\"3\"\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eAnalog to Frequency (High Speed Counter Input)\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8505 \u003c\/td\u003e\n\u003ctd\u003e 4 mA to 20 mA \u003c\/td\u003e\n\u003ctd\u003e 1,000 to 5,000 Hz from floating\u003cbr\u003eoptocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8506 \u003c\/td\u003e\n\u003ctd\u003e 0 to 5Vdc \u003c\/td\u003e\n\u003ctd\u003e 0 to 5,000 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8507 \u003c\/td\u003e\n\u003ctd\u003e 0 to 10Vdc \u003c\/td\u003e\n\u003ctd\u003e 0 to 5,000 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd bgcolor=\"#7CD0E0\" colspan=\"3\"\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eFrequency to Analog (High Speed Counter Input)\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8508 \u003c\/td\u003e\n\u003ctd nowrap\u003e 1000 to 5000 Hz optocoupler diode\u003cbr\u003e(7 mA into 3.3 KΩ, 20µS pulse width min) \u003c\/td\u003e\n\u003ctd\u003e 4 to 20 mA \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8509 \u003c\/td\u003e\n\u003ctd\u003e 0 to 5000 Hz optocoupler diode\u003cbr\u003e(7 mA into 3.3 KΩ, 20µS pulse width min) \u003c\/td\u003e\n\u003ctd\u003e 0.1 to 5 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8510 \u003c\/td\u003e\n\u003ctd\u003e 0 to 2000 Hz optocoupler diode\u003cbr\u003e(7 mA into 3.3 KΩ, 20µS pulse width min) \u003c\/td\u003e\n\u003ctd\u003e 0.05 to 5 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8513 \u003c\/td\u003e\n\u003ctd\u003e 400 to 2000 Hz optocoupler diode\u003cbr\u003e(7 mA into 3.3 KΩ, 20µS pulse width min) \u003c\/td\u003e\n\u003ctd\u003e 20 mA \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8514 \u003c\/td\u003e\n\u003ctd\u003e 0 to 2000 Hz optocoupler diode\u003cbr\u003e(7 mA into 3.3 KΩ, 20µS pulse width min) \u003c\/td\u003e\n\u003ctd\u003e 10 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd bgcolor=\"#7CD0E0\" colspan=\"3\"\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eThermocouple to Frequency (High Speed Counter Input)\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8511 \u003c\/td\u003e\n\u003ctd\u003e Type J T\/C 0 to 500°C \u003c\/td\u003e\n\u003ctd\u003e 100 to 5100 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8512 \u003c\/td\u003e\n\u003ctd\u003e Type K T\/C 0 to 500° C \u003c\/td\u003e\n\u003ctd\u003e 100 to 5100 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd bgcolor=\"#7CD0E0\" colspan=\"3\"\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eRTD to Frequency (High Speed Counter Input)\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8540 \u003c\/td\u003e\n\u003ctd\u003e Platinum RTD -100 to +400°C\u003cbr\u003e100 ohm α = 0.00385\u003cbr\u003e2 or 3 Wire Connection \u003c\/td\u003e\n\u003ctd\u003e 100 to 5100 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd bgcolor=\"#7CD0E0\" colspan=\"3\"\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eStrain Gage to Frequency (High Speed Counter Input)\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8555 \u003c\/td\u003e\n\u003ctd\u003e 0 to 50 mV Differential Signal\u003cbr\u003efrom full bridge Strain Gage,\u003cbr\u003e10 V excitation provided \u003c\/td\u003e\n\u003ctd\u003e 0 to 5 KHz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd bgcolor=\"#7CD0E0\" colspan=\"3\"\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eAnalog to Frequency (Low Speed Pulse Input)\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8605 \u003c\/td\u003e\n\u003ctd\u003e 4-20 mA \u003c\/td\u003e\n\u003ctd\u003e 100-500 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8606 \u003c\/td\u003e\n\u003ctd\u003e 0-5 Vdc \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8607 \u003c\/td\u003e\n\u003ctd\u003e 0-10 Vdc \u003c\/td\u003e\n\u003ctd\u003e 0-500 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd bgcolor=\"#7CD0E0\" colspan=\"3\"\u003e\u003cb\u003e\u003cfont color=\"white\"\u003eType J T\/C to Frequency Converters(Low Speed Pulse Input)\u003c\/font\u003e\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8611 \u003c\/td\u003e\n\u003ctd\u003e Type J T\/C 0 to 1000°C \u003c\/td\u003e\n\u003ctd\u003e 10-1100 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr valign=\"top\"\u003e\n\u003ctd\u003e DRP-8612 \u003c\/td\u003e\n\u003ctd\u003e Type K T\/C 0 to 1250°C \u003c\/td\u003e\n\u003ctd\u003e 5 Hz to 630 Hz from floating optocoupler \u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/span\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818448462119,"sku":"DRP-8500-Srs-Sig-Cond","price":434.07,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818448494887,"sku":"DRP-8500-Srs-Sig-Cond","price":434.07,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drp-8500_l_vvkszrabqfjr2duf.jpg?v=1741346107"},{"product_id":"din-rail-output-loop-powered-isolators-w-1-or-2-channel-models","title":"DIN Rail Output Loop Powered Isolators w\/ 1 or 2 Channel Models","description":"\u003cdiv itemprop=\"description\" class=\"tab-details\"\u003e\n\t\u003cspan class=\"descCopyPP\" itemprop=\"description\"\u003e The DRSL-LPO Series DIN rail 2-wire transmitter isolators provide a competitive choice in terms of both price and technology for galvanic isolation of current signals to SCADA systems or PLC equipment. These units provide isolation and 1:1 conversion of standard current signals and are powered by the host (output) current signal loop. Input transmitter (Tx) power supply of 3.5 to 32.5V is provided.\u003cbr\u003e\u003cbr\u003e The DRSL-LPO series offers isolation between input and output, provides surge suppression and protects control systems from transients and noise. These units also eliminate ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. These isolators operates over a wide temperature range from -25 to 70°C (-13 to 158°F).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSPECIFICATIONS\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eNUMBER OF CHANNELS\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eDRSL-LPO-1:\u003c\/b\u003e 1\u003cbr\u003e     \u003cb\u003eDRSL-LPO-2:\u003c\/b\u003e 2\u003cbr\u003e \u003cb\u003eCURRENT INPUT\u003c\/b\u003e\u003cbr\u003e     \u003cb\u003eSignal Range (Input to Output):\u003c\/b\u003e 3.8 to 20.5 mA\u003cbr\u003e     \u003cb\u003eSignal Conversion:\u003c\/b\u003e 1:1\u003cbr\u003e     \u003cb\u003eFunctional Range:\u003c\/b\u003e 3.5 to 23 mA (NAMUR NE43 compliant)\u003cbr\u003e \u003cb\u003eAvailable 2-Wire Transmitter (Tx) Supply:\u003c\/b\u003e 3.5 to 32.5V\u003cbr\u003e \u003cb\u003eCURRENT OUTPUT\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOutput Loop Current Limitation:\u003c\/b\u003e 24 mA typical\u003cbr\u003e \u003cb\u003eOutput Overload:\u003c\/b\u003e 50 mA max\u003cbr\u003e\u003cbr\u003e \u003cb\u003eGENERAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eSupply Voltage:\u003c\/b\u003e 6 to 35 Vdc\u003cbr\u003e \u003cb\u003eInternal Consumption:\u003c\/b\u003e 50 mW per channel\u003cbr\u003e \u003cb\u003eVoltage Drop (Input to Output):\u003c\/b\u003e 2.5V typical\u003cbr\u003e \u003cb\u003eIsolation Voltage (Test):\u003c\/b\u003e 2.5 kVac\u003cbr\u003e \u003cb\u003eIsolation Voltage (Working):\u003c\/b\u003e 300 Vac\u003cbr\u003e \u003cb\u003eSignal\/Noise Ratio:\u003c\/b\u003e \u0026gt;60 dB\u003cbr\u003e \u003cb\u003eCut-Off Frequency (3 dB):\u003c\/b\u003e 100 Hz\u003cbr\u003e \u003cb\u003eResponse Time (0 to 90%, 100 to 10%):\u003c\/b\u003e \u0026lt;5 ms\u003cbr\u003e \u003cb\u003eAbsolute Accuracy (at 25°C):\u003c\/b\u003e ≤±8 µA\u003cbr\u003e \u003cb\u003eTemperature Coefficient (\u0026gt;25°C):\u003c\/b\u003e ≤±0.02 µA [(T-25°C) x Vsupply]\u003cbr\u003e \u003cb\u003eTemperature Coefficient (\u0026lt;25°C):\u003c\/b\u003e ≤±0.07 µA [(T-25°C) x Vsupply]\u003cbr\u003e \u003cb\u003eEMC Immunity Influence:\u003c\/b\u003e \u0026lt;±0.5% of span (4 to 20 mA)\u003cbr\u003e \u003cb\u003eExtended EMC Immunity NAMUR NE 21, A Criterion, Burst:\u003c\/b\u003e \u0026lt;±1% of span\u003cbr\u003e\u003cbr\u003e \u003cb\u003eENVIRONMENTAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eOperating Temperature:\u003c\/b\u003e -25 to 70°C (-13 to 158°F)\u003cbr\u003e \u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C (-40 to 185°F)\u003cbr\u003e \u003cb\u003eCalibration Temperature:\u003c\/b\u003e 20 to 28°C (68 to 82°F)\u003cbr\u003e \u003cb\u003eRelative Humidity:\u003c\/b\u003e 0 to 95% RH non-condensing\u003cbr\u003e \u003cb\u003eProtection Degree:\u003c\/b\u003e IP20\u003cbr\u003e \u003cb\u003eInstallation Area:\u003c\/b\u003e Pollution degree 2 and measurement\/overvoltage category II\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMECHANICAL\u003c\/b\u003e\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5\")\u003cbr\u003e \u003cb\u003eWeight:\u003c\/b\u003e 70 g (0.15 lb) approx\u003cbr\u003e \u003cb\u003eDIN Rail Type:\u003c\/b\u003e DIN EN 60715 - 35 mm\u003cbr\u003e \u003cb\u003eWire Size:\u003c\/b\u003e 0.13 x 2.5 mm²\/ AWG 26 to 12 stranded wire\u003cbr\u003e \u003cb\u003eScrew Terminal Torque:\u003c\/b\u003e 0.5 Nm \u003c\/span\u003e\n\u003c\/div\u003e","brand":"hkcalibrations","offers":[{"title":"No","offer_id":49818448855335,"sku":"DRSL-LPO-Srs-Loop-Pwr-Iso","price":350.51,"currency_code":"AUD","in_stock":true},{"title":"Yes (office will call you to confirm the cost)","offer_id":49818448888103,"sku":"DRSL-LPO-Srs-Loop-Pwr-Iso","price":350.51,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/files\/drsl-lpo_series_l_pyg1sixlcz583a72.jpg?v=1741346129"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4124\/4199\/collections\/DRST-UN_l_7d37f88f-07f3-4d87-a482-7ac7fbc3f774.jpg?v=1741243797","url":"https:\/\/hkcalibrations.com.au\/collections\/din-rail-signal-conditioners.oembed?page=4","provider":"hkcalibrations","version":"1.0","type":"link"}